IBM AT-FS202SC-FS2, AT-FS202SC-FS3, AT-FS202SC-FS1, AT-FS202, AT-FS201 User Manual

...
0 (0)
AT-FS201
AT-FS202
AT-FS202SC/FS1
AT-FS202SC/FS2
AT-FS202SC/FS3
AT-FS202SC/FS4
Fast Ethernet Series Switches
Installation Guide
PN 613-10761-00 Rev E
Copyright © 2004 Allied Telesyn International, Corp.
All rights reserved. No part of this publication may be reproduced without prior
Ethernet is a registered trademark of Xerox Corporation. All other product names,
company names, logos or other designations mentioned herein are trademarks or
registered trademarks of their respective owners.
iii
Electrical Safety and Emission
Compliance Statement
Standards: This product meets the following standards.
RFI Emission EN55022 Class A 1
Warning: In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate
measures.
2
Immunity EN55024 3
Warning: This product requires shielded cables to comply with emission
and immunity standards. If it is used with unshielded cables, the user may
be required to take measures to correct the interference problem at their own
expense.
4
Electrical Safety EN60950, UL1950, CSA 950 5
Laser EN60825 6
Warning Class 1 Laser product. 7
Warning Do not stare into the Laser beam. 8
At time of installation, the Fiber Optic Lasers comply with FDA Radiation
Performance Standard 21CFR Subchapter J, applicable at date of
manufacture.
This is a “Class 1 LED Product” (AT-FS201, AT-FS202 models) 9
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device pursuant to Part 15 of FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with this
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the
FCC, can void your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du
Règlement sur le matériel brouilleur du Canada.
Electrical Safety and Emission Compliance Statement
iv
Important: Appendix B contains translated safety statements for installing
this equipment. When you see the
, go to Appendix B for the translated
safety statement in your language.
Wichtig: Anhang B enthält übersetzte Sicherheitshinweise für die
Installation dieses Geräts. Wenn Sie
sehen, schlagen Sie in Anhang B
den übersetzten Sicherheitshinweis in Ihrer Sprache nach.
Vigtigt: Tillæg B indeholder oversatte sikkerhedsadvarsler, der vedrører
installation af dette udstyr. Når De ser symbolet
, skal De slå op i tillæg
B og finde de oversatte sikkerhedsadvarsler i Deres eget sprog.
Belangrijk: Appendix B bevat vertaalde veiligheidsopmerkingen voor het
installeren van deze apparatuur. Wanneer u de
ziet, raadpleeg
Appendix B voor vertaalde veiligheidsinstructies in uw taal.
Important: L'annexe B contient les instructions de sécurité relatives à
l'installation de cet équipement. Lorsque vous voyez le symbole
,
reportez-vous à l'annexe B pour consulter la traduction de ces instructions
dans votre langue.
Tärkeää: Liite B sisältää tämän laitteen asentamiseen liittyvät käännetyt
turvaohjeet. Kun näet
-symbolin, katso käännettyä turvaohjetta
liitteestä B.
Importante: l’Appendice B contiene avvisi di sicurezza tradotti per
l’installazione di questa apparecchiatura. Il simbolo
, indica di consultare
l’Appendice B per l’avviso di sicurezza nella propria lingua.
Viktig: Tillegg B inneholder oversatt sikkerhetsinformasjon for installering
av dette utstyret. Når du ser
, åpner du til Tillegg B for å finne den
oversatte sikkerhetsinformasjonen på ønsket språk.
Importante: O Anexo B contém advertências de segurança traduzidas para
instalar este equipamento. Quando vir o símbolo
, leia a advertência de
segurança traduzida no seu idioma no Anexo B.
Importante: El Apéndice B contiene mensajes de seguridad traducidos
para la instalación de este equipo. Cuando vea el símbolo
, vaya al
Apéndice B para ver el mensaje de seguridad traducido a su idioma.
Obs! Bilaga B innehåller översatta säkerhetsmeddelanden avseende
installationen av denna utrustning. När du ser
, skall du gå till Bilaga B
för att läsa det översatta säkerhetsmeddelandet på ditt språk.
v

Table of Contents

Electrical Safety and Emission Compliance Statement ......................iii
Welcome to Allied Telesyn .........................................................................vii
Where to Find Web-based Guides ..................................................................vii
Document Conventions ...................................................................................vii
Contacting Allied Telesyn ..............................................................................viii
Online Support ........................................................................................viii
Email and Telephone Support ................................................................viii
For Sales or Corporate Information .......................................................viii
Chapter 1
Description ...................................................................................................... 1
Key Features ...................................................................................................... 4
Status LEDs ....................................................................................................... 4
Twisted-Pair Port .............................................................................................. 5
Port Speed ................................................................................................... 5
Duplex Mode ...............................................................................................5
Auto MDI/MDI-X ........................................................................................ 6
Fiber Optic Port ................................................................................................. 6
Port Speed ................................................................................................... 6
Duplex Mode ...............................................................................................6
Switch Performance ...........................................................................................7
DIP Switches ..............................................................................................7
MAC Address Table .................................................................................... 7
Store and Forward ...................................................................................... 8
External AC/DC Power Adapter ................................................................ 8
Network Topologies ...........................................................................................8
Chapter 2
Installing the Switch ................................................................................... 11
Verifying Package Contents ............................................................................11
Planning the Installation ................................................................................12
Selecting a Site .........................................................................................14
Installing the Switch .......................................................................................15
Warranty Registration ....................................................................................17
Table of Contents
vi
Chapter 3
Troubleshooting ...........................................................................................19
Appendix A
Technical Specifications ............................................................................21
Physical ............................................................................................................21
Temperature ....................................................................................................21
Electrical Rating ..............................................................................................21
Agency Certifications .......................................................................................22
Fiber Optic Port Specifications .......................................................................22
Pinout Assignments .........................................................................................24
Appendix B
Translated Safety and Emission Information .......................................27
vii
This guide contains instructions on how to install the AT-FS20x and
AT-FS202SC/FSx Series switches.

Where to Find Web-based Guides

The Allied Telesyn web site at www.alliedtelesyn.com offers you an easy
way to access the most recent documentation, software, and technical
information for all of our products. For product guides, select “Support &
Services” from our web site.

Document Conventions

This guide uses the following conventions:
Note
Notes provides additional information.
Caution
Cautions indicate that performing or omitting a specific action may
result in equipment damage or loss of data.
Warning
Warnings indicates that performing or omitting a specific action may
result in bodily injury.

Welcome to Allied Telesyn

Welcome to Allied Telesyn
viii

Contacting Allied Telesyn

This section provides Allied Telesyn contact information for technical support
as well as sales or corporate information.

Online Support

You can request technical support online by accessing the Allied Telesyn
Knowledge Base from the following web site: www.alliedtelesyn.com/kb.
You can use the Knowledge Base to submit questions to our technical support
staff and review answers to previously asked questions.

Email and Telephone Support

For Technical Support via email or telephone, refer to the Support & Services
section of the Allied Telesyn web site: www.alliedtelesyn.com.

For Sales or Corporate Information

You can contact Allied Telesyn for sales or corporate information at our web
site: www.alliedtelesyn.com. To find the contact information for your country,
select Contact Us then Worldwide Contacts.
1

Chapter 1

Description

The AT-FS20x and AT-FS202SC/FSx Series Switches include the following
models:
The AT-FS20x Series switches are designed to extend the distance of your
network by converting Fast Ethernet data between twisted-pair cabling and
either multimode or single-mode fiber optic cabling. These dual-port switches
can also be used to improve the performance of your network by dividing it
into smaller, more manageable segments.
Each switch features a 100Base-FX fiber optic port and a 10Base-T/
100Base-TX twisted-pair port. The fiber optic port has either a SC or ST
connector and a maximum operating distance of 2 kilometers (1.2 miles) to
100 kilometers (62 miles), depending on the model. The twisted-pair port has
an RJ-45 connector with a maximum operating distance of 100 meters (328
feet).
The fiber optic port operates at 100 Mbps, while the twisted-pair port operates
at 10 Mbps or 100 Mbps. Both ports feature half- and full-duplex operation.
All of the AT-FS20x Series switches can be installed on a desktop or in an
AT-MCR12 chassis. These switches are easy to install and do not require
software configuration or management. This guide provides installation
instructions for installing the AT-FS20x Series Switches on a desktop. To
install the switches in an AT-MCR12 chassis, see AT-MCR12 Chassis
Installation Guide (PN 613-10725-00).
AT-FS201 AT-FS202SC/FS2
AT-FS202 AT-FS202SC/FS3
AT-FS202SC/FS1 AT-FS202SC/FS4
Description
2
Figure 1 illustrates the front panel of an AT-FS20x Series switch.
Figure 1 AT-FS20x Series Front Panel (AT-FS202 Model)
Figure 2 illustrates a front panel of an AT-FS202SC/FSx Series switch.
Figure 2 AT-FS202SC/FSx Series Front Panel (AT-FS202SC/FS4 Model)
The back panel of the AT-FS20x and AT-FS202SC/FSx Series switches
features a power adapter connector and DIP switches for manually
configuring the ports.
Figure 3 illustrates the back panel.
Figure 3 Back Panel of the AT-FS20x and AT-FS202SC/FSx Series Switches
10Base-T/
100Base-TX
AT-FS202 FAST ETHERNET SWITCH IEEE 802.3/ 802.3U
LNK/
ACT
FD/
COL
PWR
AUTO
NEG
100M
LNK/
ACT
FD/ COL
PORT 2
100Base-FX
TX RX
PORT 1
CLASS 1
LASER PRODUCT
AT-FS202SC/FS4 FAST ETHERNET SWITCH IEEE 802.3/ 802.3U
LNK/
ACT
FD/
COL
PWR
AUTO
NEG
100M
LNK/
ACT
FD/ COL
PORT 2
100Base-FX
TX RX
PORT 1
10Base-T/
100Base-TX
CLASS 1
LASER PRODUCT
DO NOT STARE
INTO BEAM
SINGLE MODE
12 V DC
21 34
1222
PORT
10
100
HALF
FULL
OFF
ON
DUPLEX
MODE
AUTO
NEG
SPEED
(Mbps)
DIP Switches
DC Receptacle
AT-FS20x Series Installation Guide
3
Table 1 lists the maximum operating distances for the switches.
Table 1 Maximum Operating Distances
Model
100Base-FX 10/100Base-TX
Connector
Maximum
Operating
Distance
1
1. Maximum distance for 100 Mbps optical datalinks is dependent on the following factors: type of optical
fiber, duplex mode of both end-nodes, and maximum optical loss budget for each of the optical fiber at
the operating optical wavelength.
Connector
Maximum
Operating
Distance
2
2. Maximum distance can only be obtained when the UTP/STP cabling is installed and verified to TIA/EIA
568A Commercial Building Telecommunications Cabling Standard.
AT-FS201 ST 2 km (1.2 mi) RJ-45 100 m (328 ft)
AT-FS202 SC 2 km (1.2 mi) RJ-45 100 m (328 ft)
AT-
FS202SC/
FS1
SC 15 km (9.3 mi) RJ-45 100 m (328 ft)
AT-
FS202SC/
FS2
SC 40 km (24.8
mi)
RJ-45 100 m (328 ft)
AT-
FS202SC/
FS3
SC 75 km (46.5
mi)
RJ-45 100 m (328 ft)
AT-
FS202SC/
FS4
SC 100 km (62 mi) RJ-45 100 m (328 ft)
Description
4

Key Features

The AT-FS20x switches have the following features:
LEDs for unit and port status
Auto MDI/MDI-X
DIP switches for configuring the ports
Half- or full-duplex operation on both ports
RJ-45 twisted-pair connector
SC or ST fiber optic connector
Data packet forwarding and filtering at full wire speed (10 Mbps to
100 Mbps, 100 Mbps to 100 Mbps, and 10 Mbps to 10 Mbps)
Store and forward switching mode
Automatic address learning and aging
IEEE 802.3u compliant Auto-Negotiation
External AC/DC power adapters (North America, Continental Europe,
or United Kingdom)
For use on a desktop or in an AT-MCR12 chassis

Status LEDs

Table 2 defines the LEDs for the switches.
Table 2 Status LEDs
LED Color Description
PWR Green Power is applied to the switch.
LNK/ACT Green
Blinking
A valid link has been established on the port.
Data is being received or transmitted on the port.
AT-FS20x Series Installation Guide
5

Twisted-Pair Port

The AT-FS20x and AT-FS202SC/FSx Series switches have one 10Base-T/
100Base-TX twisted-pair port. The twisted-pair port features an RJ-45
connector.

Port Speed

The twisted-pair port is compliant with the 10Base-T and 10Base-TX
standards and is capable of either 10 Mbps or 100 Mbps operation. You can set
the port speed manually or, since the port is IEEE 802.3u Auto-Negotiation
compliant, you can allow the switch to set the port speed automatically. With
Auto-Negotiation, the speed of the port is set automatically by the switch after
it determines the speed of the end-node connected to the port. Auto-
Negotiation ensures that the port on the switch and the end-node are
operating at the same speed and that they are communicating at the highest
possible common speed of the devices.

Duplex Mode

Duplex mode refers to the way an end-node sends and receives data on the
network. An end-node can operate in either half- or full-duplex mode,
depending on its capabilities. An end-node that is operating in half-duplex
mode can either send data or receive data, but it cannot do both at the same
time. An end-node that is operating in full-duplex mode can send and receive
data simultaneously. The best network performance is achieved when an end-
node can operate at full-duplex, since the end-node is able to send and receive
data simultaneously.
100M Green
OFF
The twisted-pair port is operating at 100 Mbps.
The twisted-pair port is operating at 10 Mbps.
FD/COL Green
OFF
Blinking
The switch is operating in full-duplex mode.
The switch is operating in half-duplex mode.
A collision has been detected on the port.
AUTO
NEG
Green
OFF
Auto-Negotiation on the twisted-pair port is enabled.
Auto-Negotiation on the twisted-pair port is disabled.
LED Color Description
Description
6
The twisted-pair port on the switch can operated in either half- or full-duplex
mode. You can set the duplex mode manually or allow the switch to set it
automatically through Auto-Negotiation. With Auto-Negotiation, if the end-
node is capable of full-duplex mode, the twisted-pair port is set automatically
to full-duplex mode. If the end-node is capable of half-duplex mode, the port is
set automatically to half-duplex mode.

Auto MDI/MDI-X

An RJ-45 twisted-pair port on a 10 Mbps or 100 Mbps Ethernet network
device can have one of two possible wiring configurations: MDI or MDI-X. The
RJ-45 port on a PC, router, or bridge is typically wired as MDI, while the
twisted-pair port on a switch or hub is usually MDI-X.
To connect two 10 Mbps or 100 Mbps network devices together that have
dissimilar port wiring configurations, such as MDI to MDI-X, use a straight-
through twisted-pair cable. To connect two network devices that have the
same wiring configuration, such as MDI to MDI, use a crossover cable.
The AT-FS20x switches feature automatic MDI/MDI-X. The RJ-45 port
automatically determines the configuration of the port on the device to which
it is connected and then configures itself appropriately. For example, if a port
on a switch is connected to a port on a bridge, which is typically wired as MDI,
the port on the switch automatically configures itself as MDI-X. This feature
allows you to use either crossover cables or straight-through cables when
connecting a device to the twisted-pair port.

Fiber Optic Port

The AT-FS20x switches have one 100Base-FX fiber optic port. The fiber optic
port features either an SC or ST connector.

Port Speed

The fiber optic port is compliant with the 100Base-FX standard and has a
fixed operating speed of 100 Mbps. The end-node connected to the fiber optic
port on the switch must also be able to operate at 100 Mbps.

Duplex Mode

The fiber optic port on the switch can operate in half- or full-duplex mode. You
must set the duplex mode manually using the DIP switches on the back of the
unit.