Hyundai HX300, HX300L, HX200L-2000, HX400, HX200L User Manual

5 (1)

Hyundai Robot

HX300060301MME2

Manipulator Maintenance Manual

- HX200L , HX200L-2000, - HX300 , HX300L,

- HX400

The information presented in the manual is the property of HHI. Any copy or even partial is not allowed without prior written authorization from HHI.

It may not be provided to the third party, nor used for any other purposes.

HHI reserves the right to modify without prior notification.

Printed in Korea - Oct. 2005. 1st Edition

Copyright 2005 by Hyundai Heavy Industries Co., Ltd.

Contents

1. Safety

1-1

1. Safety............................................................................................

1.1. Introduction............................................................................................

1-2

1.2. Relevant Safety Regulations .................................................................

1-4

1.3. Safety Training.......................................................................................

1-4

1.4. Safety Related Nameplate.....................................................................

1-5

1.4.1. Safety Marking....................................................................................

1-5

1.4.2. Safety Nameplate ...............................................................................

1-6

1.5. Definition of Safety Functions ................................................................

1-7

1.6. Installation .............................................................................................

1-8

1.6.1. Safety Fence.......................................................................................

1-8

1.6.2. Placement of Robot & Peripheral Equipment....................................

1-10

1.6.3. Installing the Robot...........................................................................

1-12

1.6.4. Space for Robot Installation..............................................................

1-14

1.7. Safety Operation for Robot Handling...................................................

1-15

1.7.1. Safety Precautions for Robot Handling.............................................

1-15

1.7.2. Safety Precautions for Operating Test..............................................

1-18

1.7.3. Safety Precautions for Automatic Operation.....................................

1-19

1.8. Safety Precautions for Access to Safety Fence...................................

1-20

1.9. Safety Precautions for Maintenance and Repair..................................

1-21

1.9.1. Safety Precautions for Hi4a Controller Maintenance and Repair......

1-21

1.9.2. Safety Precautions for Robot System & Manipulator Maintenanace.1-22

1.9.3. Necessary Actions after Maintenance and Repair............................

1-23

1.10. Safety Functions................................................................................

1-24

1.10.1. Operating a Safety Circuit...............................................................

1-24

1.10.2. Emergency stop..............................................................................

1-26

1.10.3. Operating Speed.............................................................................

1-29

1.10.4. Connecting the Safety Devices.......................................................

1-29

1.10.5. Restricting the working Envelope....................................................

1-30

1.10.6. Monitoring Function ........................................................................

1-30

1.11. Safety Related to End Effectors.........................................................

1-31

1.11.1. Gripper............................................................................................

1-31

1.11.2. Tool / Workpiece..............................................................................

1-32

1.11.3. Pneumatic and Hydraulic Systems .................................................

1-32

1.12. Liabilities............................................................................................

1-33

2. Specifications

2-1

2. Specifications ..............................................................................

2.1. Robot Machinery Part............................................................................

2-2

2.2. Location of Robot Identification Plate ....................................................

2-3

2.3. Basic Specifications...............................................................................

2-4

2.4. Robot Dimension and Working Envelope ..............................................

2-6

i

Contents

2.5. Axis Identification.................................................................................

2-11

2.6. Details of Wrist Axis Attachment Surface ............................................

2-12

2.7. Details of Upper 1st ARM Attachment Surface.....................................

2-13

2.8. Application Wiring and Inspection Wiring Diagram ..............................

2-14

2.8.1. Details of Customer Application Connectors.....................................

2-15

2.9. Restricting the Working Envelope........................................................

2-16

2.9.1. Axis 1(Axis S)....................................................................................

2-16

3. Instructions

3-1

3. Instructions..................................................................................

3.1. Robot Component Name.......................................................................

3-2

3.2. Location of Safety Nameplate................................................................

3-3

3.3. How to operate ......................................................................................

3-4

3.3.1. Using Crane........................................................................................

3-4

3.3.2. Using Forklift Truck .............................................................................

3-6

3.4. How to Install .........................................................................................

3-7

3.4.1. Operating Conditions..........................................................................

3-7

3.4.2. Installating the Robot Manipulator ......................................................

3-8

3.4.3. Dimension of Installation Surface .......................................................

3-9

3.4.4. Accuracy of Installation Surface........................................................

3-10

3.5. Allowable Load of Wrist Axis................................................................

3-11

3.6. Recommended Standy Posture...........................................................

3-16

4. Inspection

4-1

4. Inspection ....................................................................................

4.1. Inspection Item and Period ....................................................................

4-2

4.2. Inspection Item and Period ....................................................................

4-3

4.3. Inspection of Main External Bolts...........................................................

4-5

4.4. Inspection of Wrist Backlash..................................................................

4-7

4.5. Inspection Internal Wiring ......................................................................

4-8

4.5.1. The Conditions of Safety Inspection ...................................................

4-8

4.5.2. Inspection Part....................................................................................

4-9

5. Maintenance

5-1

5. Maintenance.................................................................................

5.1. Grease Replenishment/Replacement....................................................

5-2

5.1.1. S-Axis Reduction Gear .......................................................................

5-3

5.1.2. H-Axis Reduction Gear.......................................................................

5-4

5.1.3. V-Axis Reduction Gear .......................................................................

5-6

5.1.4. R2-Axis Reduction Gear.....................................................................

5-8

5.1.5. B-Axis Reduction Gear .......................................................................

5-9

5.1.6. R1-Axis Reduction Gear...................................................................

5-11

5.1.7. Bearing Joint Parts ...........................................................................

5-13

ii

5.1.8. A1 Frame - Gear Box........................................................................

5-14

5.1.9. Wrist - Gear Box ...............................................................................

5-15

5.2. Battery Replacement ...........................................................................

5-16

5.2.1. Instructions for Battery Storage.........................................................

5-18

5.3. Internal Wiring......................................................................................

5-19

5.3.1. Wiring Connection Diagram..............................................................

5-20

6. Troubleshooting

6-1

6. Trobleshooting.............................................................................

6.1. Troubleshooting Procedure ...................................................................

6-2

6.2. Trouble Symptoms and Possible Causes..............................................

6-3

6.3. Diagnostics and Resolutions for Major Parts Failure .............................

6-4

6.3.1. Fulcrum Bearings................................................................................

6-4

6.3.2. Reduction Gear...................................................................................

6-5

6.3.3. Brakes ................................................................................................

6-7

6.3.4. Motor ..................................................................................................

6-8

6.3.5. Encoder ..............................................................................................

6-9

6.4. Motor Replacement .............................................................................

6-10

6.4.1. Necessary Tools and Parts ...............................................................

6-12

6.4.2. How to Replace Motor ......................................................................

6-13

6.5. Encoder Zero Setting...........................................................................

6-15

6.5.1. Zero Setting ......................................................................................

6-16

6.5.2. Encoder Reset..................................................................................

6-17

6.5.3. Confirming the Reset........................................................................

6-19

6.5.4. Encoder Calibration(Data input) and Selection.................................

6-20

7. Recommended Spare Parts

7-1

7. Recommended Spare Parts ........................................................

8. Internal Wiring Diagram

8-1

8. Internal Wiring Diagram ..............................................................

8.1. Manipulator Configuration......................................................................

8-2

8.2. Wiring Diagram......................................................................................

8-3

9. Decommissioning

9-1

9. Decommissioning........................................................................

iii

Contents

List of Figures

List of Figures

Fig 1.1 Recommended Size for Fence and Gate Hole (Square Gate).........

1-8

Fig 1.2 Recommended Size for Fence and Gate Hole (Slot Gate)..............

1-8

Fig 1.3 Placement of Peripheral Equipment and Operator ........................

1-10

Fig 1.4 Space for robot installation.............................................................

1-14

Fig 1.5 Robot’s Safety Circuit ....................................................................

1-24

Fig 1.6 Emergency Stop ............................................................................

1-27

Fig 1.7 Emergency Stop Connection of External System ..........................

1-28

FIg 2.1 Robot Machinery Part......................................................................

2-2

Fig 2.2 The location of identification plate....................................................

2-3

Fig 2.3 Robot Dimension and Working Envelope : [HX300] ........................

2-6

Fig 2.4 Robot Dimension and Working Envelope : [HX400] ........................

2-7

Fig 2.5 Robot Dimension and Working Envelope : [HX200L].......................

2-8

Fig 2.6 Robot Dimension and Working Envelope : [HX200L-2000] .............

2-9

Fig 2.7 Robot Dimension and Working Envelope : [HX300L].....................

2-10

Fig 2.8 Robot Dimension and Axis [HX300/400/200L/200L-2000/300L].....

2-11

Fig 2.9 Details of Wrist Axis Attachment Surface : [HX300/400/300L] .......

2-12

Fig 2.10 Details of Wrist Axis Attachment Surface : [HX200L] ...................

2-12

FIg 2.11 Details of Upper 1st ARM Attachment Surface.............................

2-13

Fig 2.12 Application Wiring and Inspection Wiring Diagram ......................

2-14

Fig 2.13 Details of Application Connector (Encoder) .................................

2-15

Fig 2.14 Details of Application Connector (Power).....................................

2-15

Fig 3.1 Identification of Robot Components.................................................

3-2

Fig 3.2 Location of Safety Nameplate..........................................................

3-3

Fig 3.3 How to Transport: Using crane [HX300/400]....................................

3-4

Fig 3.4 How to Transport: Using crane [HX200L/300L]................................

3-5

Fig 3.5 How to Transport : Using Forklift Truck

 

[HX300/400/200L/200L-2000/300L] ..............................................

3-6

Fig 3.6 Dimension of Robot Installation.....................................................

3-9

Fig 3.7 Accuracy of Installation surface .....................................................

3-10

Fig 3.8 Wrist Axis Torque Mapping:[HX300/300L]......................................

3-14

Fig 3.9 Wrist Axis Torque Mapping : [HX400].............................................

3-14

Fig 3.10 Wrist Axis Torque Mapping : [HX200L].........................................

3-15

Fig 3.11 Recommended Standby Posture .................................................

3-16

Fig 4.1 Inspection Part for Main Bolts [HX300/400/300L] ............................

4-6

Fig 4.2 Abnormal Backlash Inspecting Directions........................................

4-7

Fig 4.3 Cable Inspection Parts : [HX300/400/200L/200L-2000/300L]..........

4-9

Fig 5.1 Explains of internal wiring ..............................................................

5-20

Fig 5.2 Wiring connection diagram : [HX300/400/200L/200L-2000/300L].. 5-21

 

Fig 6.1 How to prevent dropping of ARM Axis H & V ..................................

6-11

 

 

 

 

 

 

iv

 

 

 

 

Fig 6.2 Encoder Reset Connector..............................................................

6-18

Fig 8.1 Manipulator Configuration................................................................

8-2

Fig 8.2 Motor and Brake wiring connection No.1 .........................................

8-3

Fig 8.3

Motor and Brake wiring connection No.2 .........................................

8-4

Fig 8.4

Encoder wiring Connection No.1 .....................................................

8-5

Fig 8.5

Encoder Wiring Connection No.2.....................................................

8-6

Fig 8.6

Encoder Wiring Connection No.3.....................................................

8-7

Fig 8.7 Application Wiring Connection No.1.................................................

8-8

Fig 8.8 Application Wiring Connection No.2.................................................

8-9

List of Tables

 

List of Tables

 

Table 1-1 Safety marking.............................................................................

1-5

Table 1-2 State of robot stop......................................................................

1-17

Table 2-1 Basic Specifications for Models....................................................

2-4

Table 2-2 Axis Motion..................................................................................

2-11

Table 3-1 Components name.......................................................................

3-2

Table 3-2 Allowable load weight..................................................................

3-11

Table 3-3 Allowable Load Torque................................................................

3-11

Table 3-4 Allowable Moment of Inertia.......................................................

3-12

Table 4-1 Inspection Schedule.....................................................................

4-2

Table 4-2 Inspection Items and Periods.......................................................

4-3

Table 4-3 Inspection part for main bolts .......................................................

4-5

Table 6-1 Trouble phenomenon and cause..................................................

6-3

Table 6-2 Motor Weight..............................................................................

6-10

Table 6-3 Necessary Tools.........................................................................

6-12

Table 6-4 Necessary parts .........................................................................

6-12

Table 6-5 Reset connectors corresponding to axes...................................

6-17

Table 6-6 Data range after resetting ..........................................................

6-20

Table 7-1 Spare Parts List ........................................................................

7-2

Table 7-2 Spare Parts List ........................................................................

7-4

Table 7-3 Spare Parts List ......................................................................

7-5

Table 7-4 Spare Parts List ......................................................................

7-6

Table 7-5 Spare Parts List ......................................................................

7-7

Table 9-1 Materials of each part...................................................................

9-2

v

1. Safety

1. Safety

1

Safety

1-1

 

 

 

 

 

 

 

1. Safety

HX200/HX200L-2000/HX300/HX300L/HX400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1. Introduction

The main purpose of this chapter is to describe the safety precautions for users and operators who repair and manipulate the industrial robot.

This manual describes safety precautions for robot manipulator and controller, in comply with the requirement of ANSI/RIA R15.06-1999, Standard for Safety, Industrial Robots, and qualified with safety regulations. The technical description and installation method of robot system is presented in detail at the specifications regarding installation of robot manipulator and controller.

Every operator, who installs, replaces, adjusts, manipulates, maintains, and repairs, must read thoroughly and fully understand the manipulation and maintenance manual, in particular, the special attention must be paid to the WARNING symbol, the most important marking related to the safety.

Installation, replacement, adjustment, manipulation, maintenance, and repair of robot system must be performed by the personnel who was duly trained for these purposes, following the indicated operating procedure.

This company is planning and carrying out the relevant training such as maintenance, repair, and manipulation for the above operations, so robot users make sure that robot operators should get the relevant training. And make sure that the robot handling work should be carried out only by the operators who completed this training course.

The Users of HR and HX industrial robots have a responsibility under the safety relavant regulations valid in the country where the robot is installed, and a responsibility to properly design, install, and operate the safety devices to protect workers.

The dangerous zone of robot system, that is the working range in which the robot, tool, and peripheral equipment are operated, must be safeguarded to prevent workers or objects from entering the zone. If a person or object should nevertheless enters the dangerous zone, make sure that the robot system is immediately shut down by emergency stop system. The operators of robot system have a responsibility to take all necessary steps to make correct installation, examination and operation of the relevant safety devices.

This manual is provided for the utilization of HR and HX Series Manipulator models and Hi4a controller.

Valid application and invalid environment of HR and HX Series robots are as follows.

Application

1-2

1. Safety

It is applied to the 6-axis industrial robot used by installing on the surface of wall or plane (axes addable). It is also appropriate for controlling operation in the dotted section or consecutive section.

Major application is

Spot welding

Handling

Assembly

Application such as Sealing

MIG/MAG welding

Palletizing

Grinding

For the other use than the above emergency application, make a contact with our company to consult on the robot use and possible applications.

Invalid environment

Our robot must not be used in a highly explosive environment and the areas contaminated by oil, flammable materials or chemical materials. (Prohibited to be installed and manipulated.)

1-3

HX200/HX200L-2000/HX300/HX300L/HX400

1.2. Relevant Safety Regulations

The robot is designed as per ISO10218.Jan. 1992 , safety standards for industrial robots, and furthermore in comply with ANSI/RIA 15.06-1999 regulations.

1.3. Safety Training

All the personnel who intend to teach, operate or inspect the robot must be trained in an approved robotic operation and safety training course before start-up. The safety training course includes the following details:

Purpose and functions of safety devices

Safety procedure to handle the robot

Performance of robot or the robot system and possible hazards

Tasks associated with any specific robot applications

Safety concepts, etc.

1-4

1. Safety

1.4.Safety Related Nameplate

1.4.1.Safety Marking

For the purpose of effective safety instructions, the following safety symbols are used in this manual.

Table 1-1 Safety marking

 

Symbols

 

 

 

Descrptions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicate a potentially hazardous situation which, if not

 

Warning

 

 

avoided,

could result in

death or serious injury to

 

 

 

personnel and damage to equipment. The special

 

 

 

 

 

 

 

 

attention must be paid to the operation and handling.

 

 

 

 

 

 

 

 

 

 

 

 

Mandatory

 

 

Indicate

the

compulsory

measures

that should

be

 

 

 

performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prohibited

 

 

Indicate

the

prohibited actions and/or

operations

that

 

 

 

should not be performed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-5

HX200/HX200L-2000/HX300/HX300L/HX400

1.4.2. Safety Nameplate

Identification plates, warning label and safety symbols are attached to the robot and to the inside and outside of control panel. The designation labels and cable Mark for wire harness between the robot and control panel, and the cables inside/outside of control panel are provided.

All of these plates, labels, symbols and marks constitute safety-relevant parts of the robot and the control panel. They must remain attached to the robot manipulator and control panel at their clearly visible positions all the time for the safety and their full performance.

The painted markings on the floor and signs indicating dangerous zones must be clearly distinguished in form, color, and style from other markings on the machine near the robot system or inside the plant facilities where the robot system is installed.

It is forbidden to remove, cover, or paint over by way of spoiling the clearly visible identification plates, warning labels, safety symbols, designation labels and cable marks.

1-6

1. Safety

1.5. Definition of Safety Functions

Emergency Stop Function - IEC 204-1,10,7

There is one emergency stop button on the controller and teaching pendant respectively. If necessary, additional emergency buttons should be able to connected to the robot's safety chain circuit. The emergency stop function, which overrides all other robot controls, stops all moving parts by disconnecting power supply, and removes drive power to prevent the use of other dangerous functions controlled by the robot.

Safety Stop Function - ISO 10218(EN 775),6.4.3

When a safety stop circuit is provided, each robot must be delivered with the necessary connections for the safeguards and interlocks associated with this circuit. The robot should have a number of electrical input signals which can be used to connect external safety devices, such as safety gates, safety pads, and safety lamps. These signals allow the robot's safety functions to be activated by all equipment, including peripheral equipment and the robot itself.

Speed Limiation Function - ISO 10218(EN 775),3.2.17

In a manual mode, the speed of robot is strictly limited to 250 mm per second as maximum.

The speed limitation applies not only to the TCT(Tool Coordinate Time), but to all parts of manual mode robot. The speed of equipment mounted on the robot should be possibly monitored.

Restricting working Envelope - ANSI/RIA R15.06-1999

The working envelope of robot axes should be restricted using software limits. Axis 1,2, and 3 can also be restricted by means of mechanical stopper.

Operation Mode Selection - ANSI/RIA R15.06-1999

The robot must be operated either manually or automatically. In a manual mode, the robot must be operated only by using the teach pendant..

1-7

Hyundai HX300, HX300L, HX200L-2000, HX400, HX200L User Manual

HX200/HX200L-2000/HX300/HX300L/HX400

1.6. Installation

1.6.1. Safety Fence

Install safety fence against the possible collision between the robot and workers, so that no worker may approach the robot .When operators or other personnel enter the robot's working envelope by accident, it may cause an accident. Install the safety fence to stop the robot when one, who intends to replace for TIP DRESSING or TIP replacement, or to inspect welding equipment, opens the fence gate and approaches the equipment during operation.

0.3m (12") Max

1.5m (60") Min

 

 

4.9cm(1.875") Max

4.9cm(1.875") Max

Fig 1.1 Recommended Size for Fence and Gate Hole (Square Gate)

0.3m (12") Max

1.5m (60") Min

 

4.9cm(1.875") Max

Fig 1.2 Recommended Size for Fence and Gate Hole (Slot Gate)

Install the safety fence to cover the robot’s working envelope and to secure enough space for teaching and maintenance working. The safety fence should also be firmly installed so that it is hardly accessible and removable.

1-8

1. Safety

The safety fence should be a fixed type in principle, using harmless materials that do not have any broken surface or projecting part.

Install the safety fence with an entrance gate, and register the safety plug at the gate so that it does not open unless pulling the plug out. Interlock the robot to be MOTORS OFF when the safety plug is pulled out., or wire the robot to be MOTORS OFF when the safety fence is open. (Refer to “11. Connecting the Other Signals”, Hi4a Controller Manual)

When intending to operate the robot with the safety plug pulled out, wire the robot as a low-speed play mode. (Refer to “11. Connecting the Other Signals”, Hi4a Controller Manual)

For immediate emergency stop, install emergency stop button wihin operator’s easily accessible distance.

If the safety fence is not installed, install other devices substituting for the safety plug in the whole place within the robot’s working envelope, such as photoelectric switch and mat switch. These devices may stop the robot automatically when a person enters the working envelope.

The robot’s working envelope(dangerous zone) should be distinguished from other zones by painting its floor.

1-9

HX200/HX200L-2000/HX300/HX300L/HX400

1.6.2. Placement of Robot & Peripheral Equipment

(1)Make sure that the power supply is off before operating, when connecting the primary power of controller or peripheral equipment. There is a possible danger of electric shock because the high voltage such as 220V and 440V is used as its primary power.

(2)Post a sign [No enter during operation] up the safety fence gate, and inform the operators of its purport.

110

cm(44 " ) M in

 

 

 

 

in

 

 

 

 

M

 

 

 

)

 

 

 

"

 

 

 

 

4

 

 

 

4

 

 

(

 

 

 

m

 

 

 

 

c

 

 

 

 

0

 

 

 

1

 

 

 

1

 

 

 

 

110 cm(44") Min

Operator

Controller

Interlocked Barrier Guard

Restricted

space

Maximum

Safeguarded

space

space

Fig 1.3 Placement of Peripheral Equipment and Operator

(3)Arrange such devices as controller, interlock panel, and other manipulation panels to be handled outside of the safety fence.

(4)When installing operation stand, install the emergency stop button on the stand. Make sure that the stand stops in an emergency wherever the robot is handled.

1-10

1. Safety

(5)Make sure that the robot manipulator and the wiring and piping of controller, interlock panel, and timer should not be placed in the way of operator's

working range so that they would not be directly stepped on by FORK and LIFT. There is a possible danger of accident if the workers are affected by electricity or the wiring is down.

(6)Place the controller, interlock panel, and handling stand within the sight of robotic performance. It may cause a serious accident to operate the robot while the operator is working, or the robot is malfunctioning in an invisible sight.

(7)Restrict the robot's working envelope by using soft limits and mechanical stopper if the necessary working envelope is narrower than the holding workable envelope. It is possible to stop the robot in advance when it moves beyond its normal working envelope due to an abnormal condition. (Refer to the Robot Manipulator Maintenance Manual .)

(8)Welding spatters directly on the operator or around him may cause burning or fire. Install such devices as a glare shield or a cover in the full sight of robot's working envelope.

(9)Make sure that the device indicating the robot's running condition whether automatic or manual mode must be noticeable even in the far distance. In the case of automatic start-up, warning with a buzzer or warning lamp is also valid.

(10)Make sure that there is no projecting part in the robot's peripheral equipment. Cover it, if necessary. It usually may cause an accident if the operator comes in touch with it. And it may lead a serious accident if the operator is astonished at the sudden movement of robot, and conducts it.

(11)Don't make the system designed to allow the workers to carry the Work in and out using their hands through the safety fence. It could be a cause of accident associated with compressing or amputating.

1-11

HX200/HX200L-2000/HX300/HX300L/HX400

1.6.3. Installing the Robot

Install the robot as per the planning and layout which has been previously reviewed and studied for its optimized performance and functionality. In case of poor conditions for robot installation, the serious problems can take place, including error of relative position between robot and workpiece during operation, bad performance quality of robot caused by vibration, shortening lifetime, and cause of serious accidents. Thus, pay attention to the following precautions when installing the robot.

General Safety Precautions

(1)Design and install the robot system properly in compliance with laws, regulations, and safety requirements valid in the country where the robot system is installed.

(2)All the workers for the robot system must have the complete knowledge on the information specified in the application and supplementary manual, and proficiently operate and handle the industrial robot.

(3)Installation workers of robot must follow the safety instructions and apply them to the installation when they face any safety problems.

(4)System provider must ensure that all the circuits utilizing safety functions perfectly perform in a safe way.

(5)Install main power supply to be disconnected from outside of the robot’s working envelope.

(6)System provider must ensure that all the circuits utilizing emergency stop function perfectly perform in a safe way.

(7)For the immediate emergency stop, install emergency stop button within the accessible distance for the operator.

Technical Safety Precautions

(1)Eliminate any interference with peripheral equipment considering the dimension and working envelope.

(2)Avoid such places for installing which is directly exposed to the sun, extremely humid, contaminated by oil or chemicals, and containing a large amount of metal powder and explosive gas.

1-12

1. Safety

(3)Install at the ambient temperature ranged 0~45 .

(4)Secure sufficient space for the easier disassembly and maintenance.

(5)Install safety fence with a gate, and prohibit any person from entering the robot's working envelope.

(6)Remove any obstacles out of the robot’s working envelope.

(7)Take a special measure, considering thermodynamics of controller, if the robot is installed near the heating elements or places exposed directly to the sun.

(8)Take a special measure if the robot is installed in a place of abundant dust such as metal powder in the air.

(9)Install the robot not to transmit welding electric current. (In other word, insulate SPOT GUN with/from the robot’s wrist.)

(10)Grounding is very critical in preventing electric shock and malfunction caused by noise, and thus install as following instructions.

Install an exclusive grounding terminal using class 3 or higher. (For the input voltage of 400V of higher, use special class 3 or higher.)

Connect grounding line into the grounding bus-bar inside of the control panel.

In case of direct grounding on the floor by anchoring, two-point grounding both by robot manipulator and by controller can produce a “ground loop” and contrariwise cause abnormal operation. In this case, connect the grounding line to the base of robot manipulator and disconnect the second grounding point to the controller. If the robot vibrates even after stopping, double-check the grounding status because the possible main causes could be an incomplete grounding or “ground loop” .

In the use of internal transgun(GUN), there is a possible danger of dropping because the primary power cable is directly connected to the spot gun. In this case, directly connect the grounding line to the base of robot manipulator in order to prevent any electric shock and protect the control panel, but do not connect it to the controller.

1-13

HX200/HX200L-2000/HX300/HX300L/HX400

1.6.4. Space for Robot Installation

Install robot after securing sufficient space for maintaining the robot manipulator, Hi4a controller, and other peripheral equipment. Install the robot manipulator and controller, securing space for installation as per the guideline as described in the figure below. Install Hi4a controller outside of the safety fence in order to monitor the robot manipulator and to operate in a safe way.

Door

Minimum 110cm

Hi4a Controller

SafetyFence

Minimum110 cm

Working Envelope

Working Envelope with Tool and

Workpiece installed

Fig 1.4 Space for robot installation

When installing, be sure to make it easier to perform the maintenance when opening the Hi4a Controller door. Secure the available space. The controller power in the above Figure could change depending on the kind of controller.

1-14

1. Safety

1.7. Safety Operation for Robot Handling

Follow the safety instructions to prevent any accidents. Don't modify nor ignore safety devices or circuits at any time, and be careful of electric shock.

All the normal operations in an automatic mode must be performed outside of the safety fence. Check the robot's working envelope if anyone is inside before operating.

1.7.1. Safety Precautions for Robot Handling

(1) Do not handle the robot other than such personnel as operators handling the robot and other possible operators and supervisors who were designated as whom duly trained in an approved robotic training course and become familiar enough with the proper operation of the safety and robotic functions.

(2)Be sure to wear helmets, goggles, and safety shoes.

(3)Perform the work in pairs. One person must be ready to press the emergency stop button in an emergency while the other must perform his work quickly but carefully within the robot’s working envelope. Always check the escape route before working.

(4)Make sure that there is no one in the working envelope when the power source is on.

(5)Operations such as teaching must be performed outside of the robot's working envelope. However, if the operation is performed within the working envelope after stopping the robot, enter the envelope with safety plug or key switch for converting to automatic mode. Make sure that other operators do not change it into automatic mode by accident. Also, pay close attention to the specific direction of robotic movement in case of abnormal operation and malfunction.

(6)Supervisors should follow the instructions below.

Be located at a place where you could take an entire view of robot, and commit yourself to monitoring.

Press the emergency stop button immediately when abnormality is found.

Anyone is forbidden to be near the operating area other than those who are engaged in the operation.

(7)In a manual mode, the speed of teaching is limited to 250mm/sec

(8)In teaching, post a sign [Under Teaching].

1-15

HX200/HX200L-2000/HX300/HX300L/HX400

(9)Operators must pull the safety plug out, and enter the safety fence with the plug.

(10)Do not use any devices causing noise in and around the teaching area.

(11)Handle the teaching pendant button, while checking the teaching point with your naked eyes, and do not handle it just relying on your sense.

(12)Do not work with your back against the robot, and always pay attention to the robot's movement.

(13)In teaching, check and examine carefully under your feet. In particular, in high teaching for more than 2M, secure a safe zone on which you may step before teaching.

(14)Instructions for any abnormal operations.

Press immediately the emergency stop button when any abnormal operations are found.

Be sure to check if the relevant equipment is stopped when checking the abnormality in an emergency stop.

In case that the robot stops automatically due to power failure, investigate possible causes and take actions after confirming that the robot completely stops.

In case of malfunction of emergency stop devices, immediately disconnect the main power and investigate possible causes to take necessary actions.

Investigation of the failure must be conducted only by a designated person. For the re-operation after emergency stop, operators must clarify the cause of failure and take necessary actions, and then operate the robot again following the proper procedure.

(15)Write out the operating rules proper to working details and installing location regarding the operation and handling method for the robot, and the necessary actions for robot's any failure. In addition, it is recommended to operate the robot in accordance with the operating rules.

(16)Instructions when the robot stops

Make sure not to approach the robot even when it seems to be stopped. Most accidents occur from a sudden movement of robot which seemed to be stopped when one approaches it. The conditions that the robot stops is as follows.

1-16

1. Safety

Table 1-2 State of robot stop

No.

State of Robot

Drive Power

Access

 

 

 

 

1

Pause

ON

X

(Minor failure, Pause switch)

 

 

 

 

 

 

 

2

Emergency stop

OFF

O

(Major failure, Emergency stop switch, Safety gate)

 

 

 

 

 

 

 

3

Input signal standby of peripheral equipment

ON

X

(START INTERLOCK)

 

 

 

 

 

 

 

4

Playback Completion

ON

X

 

 

 

 

5

Standby

ON

X

 

 

 

 

Even in the accessible state of robot, be watchful against any possible sudden movement of robot. Make sure to avoid approaching the robot without precautions for emergency under all circumstances.

Though the access during a pause is shown in the table as × , allow the access to robot with the same precautions as teaching work if the entrance is open to take actions for minor failures(i.e. malfunction caused by failure in arc, nozzle contact and weldment detection).

(17)Clean up any split oil, tools, and impurities in the safety fence after completing robotic operation. Accidents such as conduction may occur in the working envelope contaminated by oil, or scattered tools on its floor. Make a habit of organizing and cleaning things up.

1-17

HX200/HX200L-2000/HX300/HX300L/HX400

1.7.2. Safety Precautions for Operating Test

In case of operating test, errors in design or teaching and inferiority in manufacturing are possibly seen in the entire system such as teaching program, jig, and sequence. Thus, be more careful and safe in case of operating test. Accidents may occur by these combined causes.

(1)Before handling, check the stop buttons and signal functions to stop the robot such as emergency stop button or stop button. And then, check the abnormality - detective movements. Above all, it is the most critical to check all the stop signals. It would be the most important to stop the robot when any possible accidents are predicted.

(2)In case of operating test, start the robot at low speed(approximately 20%~30%) in the variable speed function, and repeat it more than one cycle to check the movements. If any errors are found, immediately correct them. After then, increase in speed (50% → 75% → 100%) gradually, and repeat more than one cycle respectively to check the movements. Operating at high speed from the very beginning may cause a serious accident.

(3)In case of operating test, it is hard to predict what problems would happen. Do not enter the safety fence during operating test. Unexpected accidents are likely to occur because of its low reliability.

1-18

1. Safety

1.7.3. Safety Precautions for Automatic Operation

(1)While posting a sign [Do Not Enter During Operation] up the safety fence gate, ask the operators not to enter during operation. If the robot stops, you may enter the safety fence under your full understanding of the situation.

(2)Be sure to check if any operators are inside of the safety fence when starting the automatic operation. Operating without checking the presence of operators may cause a personal injury.

(3)Before starting the automatic operation, check and confirm that the program number, step number, mode, and starting selection are in the possible state for automatic operation. If starting with the other programs or steps selected, the robot could move in an unpredicted way, and lead to an accident.

(4)Before starting the automatic operation, check if the robot is properly located to get started. Check whether the program number or step number is identical with the location of robot. Even if it's all identical, accidents are still possible to occur due to an abnormal movement when the robot is differently located..

(5)Be prepared to immediately press the emergency stop button when starting the automatic operation. Immediately press the emergency stop button in case of robot's unexpected movements or emergency.

(6)Be sure to detect any abnormalities by checking the route, condition, or sound of robot movement. Sometimes the robot may be abnormally operated including a sudden break down. However, it will show(give) a certain indication before the break down. Understand the robot's normal condition well in order to catch the symptom in advance.

(7)When any abnormality is detected from the robot, immediately stop and take proper actions on it. Using the robot before any proper actions taken may cause an interruption of produce as well as serious failure leading to a very serious personal injury.

(8)When checking the robot’s movement after the proper actions taken for the abnormality, do not operate the robot with operators inside of the safety fence. Unexpected accidents are possibly to occur because its low reliability may cause another abnormality.

1-19

HX200/HX200L-2000/HX300/HX300L/HX400

1.8. Safety Precautions for Access to Safety Fence

Robots are very powerful and heavy even at its low speed. When entering the safety fence, one must observe the relevant safety regulations of its pertinent country.

The operators always must be aware of the unexpected movements of robot. Robots are able to move fast shortly after being stopped. The operators should know that the robot is able to move in a different route, without any notice, by means of external signals. Thus, when trying to stop the robot during teaching or operating test, one should be able to stop the robot with a teaching pendant or control panel.

When entering the working envelope through the safety gate, take the teaching pendant with you so that other people may not operate the robot. Make sure to post up the control panel a sign indicating the state of robot handling.

Read carefully and be aware of the follows when entering the working envelope.

(1)Do not enter the working envelope other than teaching person.

(2)Be sure to set the ‘handling setting’ on teaching pendant to TEACHING LOCK.

(3)Operation set-up mode of controller must be a manual mode in the control panel.

(4)Always wear the approved working suite.(Do not wear a loose clothes as you please)

(5)Do not wear gloves when handling Hi4a contoller.

(6)Do not leave innerwear such as underwear, shirts, or necktie out of the working suite.

(7)Do not wear personal accessories such as big earrings, rings, or necklaces.

(8)Make sure to wear safety shoes, helmet, and goggles and if necessary, wear other self-protective outfit such as safety gloves.

(9)Make sure that the emergency stop circuit is working correctly and in its proper function, turns MOTORS OFF when pressing the emergency stop button in the control panel and teaching pendant before handling the robot.

(10)Make your posture face-to-face with the robot manipulator when performing your work.

(11)Follow the predetermined working procedure.

(12)Be prepared for emergency exit or safe place considering that the robot may unexpectedly rush at you.

1-20

1. Safety

1.9.Safety Precautions for Maintenance and Repair

1.9.1.Safety Precautions for Hi4a Controller Maintenance and Repair

(1)Maintenance and repair of the robot must be performed by the personnel who was duly trained in the special maintenance training course and has a good knowledge of maintenance.

(2)Perform your work following the maintenance procedures for controller.

(3)Perform your maintenance and repair in a safe way by securing emergency exit or safe place.

(4)Before the daily maintenance, repair, or changing parts, be sure to power down. In addition, post a warning sign [Do Not Input Power] up the primary power so that other operators may not input power by accident..

(5)When changing parts, be sure to use the specified ones.

(6)Be sure to power down when opening the Hi4a controller door.

(7)Before performing, wait for three minutes after power down.

(8)Do not touch the heat sink and regeneration resistor of servo amp because they generate an intense heat.

(9)After completing maintenance, Be sure to close the door completely after checking if tools or other things are still remained in the Hi4a controller.

1-21

HX200/HX200L-2000/HX300/HX300L/HX400

1.9.2. Safety Precautions for Robot System & Manipulator Maintenanace

(1)Refer to the safety precautions for Hi4a controller maintenance and repair.

(2)Perform your maintenance and repair for the robot system and manipulator, following the indicated procedures.

(3)Be sure to disconnect the primary power of controller. Post the warning sign [Do not input power] up the primary power to prevent other workers from connecting the power.

(4)Make sure that the Arm is fixed and immovable before maintenance and repair since dropping or moving of the robot's Arm may cause a danger during maintenance and repair. (Refer to the Robot manipulator maintenance manual .)

1-22

Loading...