Hunter Fan 47110A User Manual

0 (0)

M

Model 47110A

®

2

 

 

Congratulations!

Your new Hunter thermostat will provide years of reliable service. By saving energy, your thermostat will pay for itself during its first season of use. Thank you for buying a Hunter product!

Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Hunter Technical Support at 1-866-268-1936 from 8am to 5pm Central Time.

Before starting, remove the mylar label from the LCD display.

IMPORTANT INFORMATION

1. This thermostat is designed to work on the following systems:

Gas - Standing Pilot

Electric Furnace

Gas - Electronic Ignition

Electric Air Conditioning

Gas - Fired Boilers

 

Gas - Milivolt Systems

This thermostat will NOT control single-stage or

Oil - Fired Boilers

multi-stage heat pumps or 110/220 V baseboard

Oil - Fired Furnace

electric heating systems.

2. Temperature Range

This thermostat can be programmed between 7˚C and 35˚C (45˚F and 95˚F). It will display room temperatures from 0˚C and 37˚C (30˚F to 99˚F). “HI” will be displayed if the temperature is higher than 37˚C (99˚F), and “LO” will be displayed if the temperature is lower than 0˚C (30˚F).

This thermostat will automatically cut-off in Heat mode if the temperature rises above 35˚C (95˚F), and automatically cut-off in Cool mode if the temperature drops below 4˚C (40˚F).

3. Compressor Protection

This thermostat provides a 3.5 minute delay after shutting off the cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. It does not prevent a rapid compressor restart due to short power outages.

4. Battery Warning

Two fresh AA alkaline batteries should provide well over one year of service. However, when the batteries become drained, the Low Battery Indicator will flash on the display. When this message occurs, install new alkaline batteries. You have approximately 1 minute to change the batteries and keep thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for flashing Low Battery Indicator on the LCD display.

CAUTION: When only the battery icon flashes on the display, the thermostat is shut down, and your system will no longer operate. In this condition, there is no temperature control of your dwelling.

NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving.

FEATURES

Front Door: Covers keys when not used for neat

Day / Time Key: Used for entering the Clock

appearance. Open by lifting from the bottom

 

setting mode. Use with the Up and Down keys

 

 

 

 

to set the time and day.

LCD Display: Shows

 

 

 

 

 

Time, Day, Temperature,

 

 

 

 

Up and Down Keys: Keys for

Program Number, and

 

 

 

 

 

 

 

 

changing the Temperature

other feature information

 

 

 

 

 

 

 

 

setting. Also used for increasing

as required.

 

 

 

 

 

 

 

 

and decreasing selections in the

Low Battery Indicator:

 

 

 

 

Time, Program, and Span

 

 

 

 

functions.

Flashes when batteries

 

 

 

 

 

need to be replaced.

 

 

 

 

Program Key: Used for entering

 

 

 

 

 

System Switch:

 

 

 

 

and modifying Programs. Use

 

 

AM

 

with the Up and Down keys to

Selector switch for

 

M

 

set times and temperatures.

Heat, Cool, and Off

 

 

TEMP

 

Press when in Clock setting

 

 

 

 

mode to select between 12 and

 

 

 

4

 

 

Fan Switch: Fan

 

 

 

 

24 hour clock modes.

switch for Automatic

system

 

program

 

or Continuous fan

off

heat

 

Filter Key: Resets filter change

cool

day/time

 

operation.

 

 

 

fan

reset

filter

counter to zero.

 

 

 

 

 

 

auto

 

 

Battery Compartment:

 

 

hold

 

 

on

 

Hold / Return Key: Used for

Front access allows

 

 

 

/return

 

 

 

setting a permanent (vacation)

easy insertion of two

 

 

 

 

 

 

 

 

hold, and for returning to the

AA 1.5V batteries.

 

 

 

 

 

 

 

 

normal display from Day & Time

 

 

 

 

 

 

 

 

 

 

setting, Programming, or Span

Reset: Press with a paper clip to reset the

Battery Release Lever: Push

setting modes.

 

thermostat and return to power-up settings.

to pop batteries loose.

 

ENERGY STAR® PARTNER

As an ENERGY STAR® Partner, Hunter Fan Co. has determined that this programmable thermostat meets the ENERGY STAR® guidelines for energy efficiency.

INSTALLATION

What You Need

This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials.

Slotted Screwdriver(s)

Small Philips screwdriver

Hammer

Electric drill and 3/16” bit

Two 1.5 V (AA) size alkaline batteries

Remove Old Thermostat

CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. Wires must be labeled prior to removal.

IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace.

Remove existing thermostat cover and thermostat. See Figure 1. Some thermostats will have screws or other locking devices that must first be removed. Once the wall mounting plate is exposed, look for wires.

If wires are not visible, they may be connected to the back of the wallplate. Again, look for screws, tabs, etc. Some models have doors that open to expose wires and mounting screws. See Figure 1.

Typical Home Thermostats

Wall Mounting Plate

Thermostat

Cover

Wall Mounting Plate

Thermostat

Cover

Figure 1

Wire Labeling

Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in Table A below.

The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If you follow the labeling procedures correctly, you do not have to be concerned about how many wires there are.

There is often no terminal marking on the existing thermostat of

two wire, heat only systems. Just connect either of the wires to

W

G Y

the RH terminal, then connect the other wire to the W terminal to

RH

complete the circuit.

 

RC

IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELF-ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A BELOW. (For example, attach the label marked W to the wire that goes to the W or H terminal on your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard.

(Continued)

Hunter Fan 47110A User Manual

®

3

 

 

Wire Labeling (Continued)

After labeling wires, disconnect them from the existing thermostat terminals.

Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall.

If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading.

If the code letter on your

then mark the wire

and connect to thermostat

existing thermostat is

with label shown

terminal shown

RH, R, VR or4 24 Volt

RC, VC

24 Volt Cool

G or F

Fan

Y, C or M

Air Conditioning Compressor

W or H

Heating

RH

RC

G

Y

W

Table A

RH

x

RC

x

G

x

Y

x

W

x

NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to nonbattery powered thermostats.

Mount Wallplate and Thermostat

Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2.

Figure 2

W

 

Y

Rc

Rh

 

G

Figure 3

Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the Hunter wallplate.

Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall.

Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3.

NOTE: 5-wire Systems

If your thermostat has one wire marked R or RH (2, 3, or 4-wire system), then leave the jumper wire between the RH and RC terminals on the wallplate. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.

Connect Wires and Mount Thermostat to Wallplate

Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat.

Refer to the Wiring Diagrams below to be sure your system is wired correctly.

Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat.

Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate.

Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO.

Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE:

Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.)

Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment.

Switch on the main power at the panel or furnace.

Figure 4

Figure 5

Loading...
+ 4 hidden pages