IMPORTANT

Only qualified service technicians should install, service, or maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/ manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the equipment in accordance with this manual may adversely affect safety, performance, component life, and warranty coverage.

Hoshizaki provides this manual primarily to assist qualified service technicians in the installation, maintenance, and service of the icemaker.

Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, write, or send an e-mail message to the Hoshizaki Technical Support Department for assistance.

HOSHIZAKI AMERICA, INC.

618 Highway 74 South

Peachtree City, GA 30269

Attn: Hoshizaki Technical Support Department

Phone: 1-800-233-1940 Technical Support (770) 487-2331

Fax: 1-800-843-1056 (770) 487-3360

E-mail: techsupport@hoshizaki.com

Web Site: www.hoshizaki.com

NOTE: To expedite assistance, all correspondence/communication MUST include the following information:

Model Number

Serial Number

Complete and detailed explanation of the problem.

2

IMPORTANT

 

This manual should be read carefully before the icemaker is installed and

 

operated. Only qualified service technicians should install, service, and

 

maintain the icemaker. Read the warnings contained in this booklet carefully as

 

they give important information regarding safety. Please retain this booklet for

 

any further reference that may be necessary.

 

CONTENTS

 

Important Safety Information..................................................................................................

4

I. Specifications......................................................................................................................

5

A. Construction...................................................................................................................

5

B. Electrical Data................................................................................................................

6

C. Dimensions/Connections...............................................................................................

7

1. AM-50BAE.................................................................................................................

7

2. AM-50BAE-DS..........................................................................................................

8

3. AM-50BAE-AD..........................................................................................................

9

4. AM-50BAE-ADDS...................................................................................................

10

II. Installation and Operating Instructions..............................................................................

11

A. Checks Before Installation............................................................................................

11

B. Location........................................................................................................................

11

1. General.....................................................................................................................

11

2. Built-In Installation Site............................................................................................

12

C. Door.............................................................................................................................

13

1. AM-50BAE, AM-50BAE-AD.....................................................................................

13

a) Hinge Reversal...................................................................................................

13

2. AM-50BAE-DS, AM-50BAE-ADDS..........................................................................

15

a) Overlay Panel Fabrication and Attachment.........................................................

15

D. Setup...........................................................................................................................

23

E. Electrical Connection...................................................................................................

23

F. Water Supply and Drain Connections...........................................................................

24

G. Final Checklist ............................................................................................................

25

H. Startup.........................................................................................................................

26

III. Cleaning and Maintenance..............................................................................................

27

A. Cleaning and Sanitizing Instructions............................................................................

27

1. Cleaning Solution....................................................................................................

27

2. Cleaning Procedure.................................................................................................

27

3. Sanitizing Solution..................................................................................................

29

4. Sanitizing Procedure...............................................................................................

29

B. Maintenance................................................................................................................

32

C. Preparing the Icemaker for Long Storage....................................................................

33

3

Important Safety Information

Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.

WARNING

Indicates a hazardous situation which could result in death or

 

serious injury.

CAUTION

Indicates a situation which could result in damage to the unit.

IMPORTANT

Indicates important information about the use and care of the

 

unit.

WARNING

This icemaker should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and therefore dangerous. The manufacturer cannot be held responsible for injury or damage resulting from improper, incorrect, and unreasonable use.

To reduce the risk of death, electric shock, serious injury, or fire, follow basic precautions including the following:

This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuse, or damage to existing wiring. This could lead to heat generation or fire.

THIS UNIT MUST BE GROUNDED: This unit is equipped with a 3 prong grounding plug to reduce the risk of potential shock hazards. It must be plugged into a properly grounded, independent wall outlet. If the outlet is a 2-prong outlet, it is your personal responsibility to have a qualified electrician replace it with a properly grounded, independent 3-prong wall outlet. Do not remove the ground prong from the power cord and do not use an adapter plug.

Do not use an extension cord.

Make sure the control switch is in the "OFF" position before plugging in or unplugging the unit to reduce the risk of electric shock.

Do not use a unit with a damaged power cord.The power cord should not be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could result in electric shock or fire. To unplug the unit, be sure to pull the plug, not the cord, and do not jerk the cord.

To reduce the risk of electric shock, do not touch the plug or control switch with damp hands.

This unit should be disassembled or repaired only by qualified service personnel to reduce the risk of electric shock, injury, or fire.

Do not make any alterations to the unit.Alterations could result in electric shock, injury, fire, or damage to the unit.

4

I. Specifications

A. Construction

Top Panel

Ice Making

Mechanism

Bin Control

Thermostat

Bulb

Scoop Holder

Slope

Magnet

Catch

Front Panel

Control Switch

Door

Power Cord

Louver

5

B. Electrical Data

HOSHIZAKI ICE MAKER

MODEL NUMBER

AM-50BAE

SERIAL NUMBER

115-120/60/1

AC SUPPLY VOLTAGE

AMPERES

3.4 AMPS

DESIGN PRESSURE

HI-240PSI LO-120PSI

REFRIGERANT

134a 4.2 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED

APPROVED FOR OUTDOOR USE

Hoshizaki America, Inc.

Peachtree City, GA

www.hoshizaki.com

For certification marks, see the nameplate in the storage bin.

Note: Only the "MODEL NUMBER" is replaced for AM-50BAE-DS, AM-50BAE-AD, and

AM-50BAE-ADDS.

The nameplate provides electrical and refrigerant data. The nameplate is located in the storage bin.

We reserve the right to make changes in specifications and design without prior notice.

6

Hoshizaki AM-50BAE-DS, AM-50BAE-ADDS, AM-50BAE-AD User Manual

C.Dimensions/Connections

1.AM-50BAE

Units: mm [in.]

7

2. AM-50BAE-DS

Units: mm [in.]

8

3. AM-50BAE-AD

Units: mm [in.]

9

4. AM-50BAE-ADDS

Units: mm [in.]

10

II. Installation and Operating Instructions

WARNING

1.This icemaker must be installed in accordance with applicable national, state, and local codes and regulations.

2.CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are securely in place after installation. Make sure that none have fallen into the storage bin.

A.Checks Before Installation

Visually inspect the exterior of the shipping container and immediately report any damage to the carrier. Upon opening the container, any concealed damage should also be immediately reported to the carrier.

Remove the shipping carton, tape, and packing material. If any are left in the icemaker, it will not work properly.

Remove the package containing the accessories.

Remove the protective plastic film from the panels. If the icemaker is exposed to the sun or to heat, remove the film after the icemaker cools.

See the nameplate on the left side panel, and check that your voltage supplied corresponds with the voltage specified on the nameplate.

B.Location

1. General

This icemaker is approved for indoor or outdoor use.

CAUTION

1.Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 95°F

(7°C to 35°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.

2.This icemaker will not work at sub-freezing temperatures. To prevent damage to the water supply line, drain the icemaker if the air temperature is going to go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."

For best operating results:

The icemaker should not be located next to ovens, grills, or other high heat producing equipment.

The location should provide a firm foundation for the icemaker.

This icemaker requires no side or top clearance. But allow enough space at rear for water supply and drain connections and at least 15" (38 cm) clearance at front.