SECTION 2. INSTALLATION

2-1. INTRODUCTION

2-2. UNPACKING INSTRUCTIONS

This section provides the installation and unpacking instructions for the Henny Penny PFG-691.

Installation of this unit should be performed only by a qualified service technician.

Do not puncture the fryer with any objects such as

drills or screws as electrical shock or component damage could result.

Any shipping damage should be noted in the presence of the delivery agent and signed prior to his or her departure.

1.Cut and remove the plastic bands from the main box.

2.Remove the box lid and lift the main box off the fryer.

3.Remove four corner packing supports.

4.Cut the stretch film from around the carrier/rack box and remove it from the top of the fryer lid.

5.Cut and remove the metal bands holding the fryer to the pallet.

All counterweights must be loaded before unlatching the lid, or personal injury could result.

6.Remove the fryer from the pallet.

Take care when moving the fryer to prevent personal injury. The fryer weighs approximately 935 lbs. (424 kg).

1104

2-1

Model 691

2-2. UNPACKING

7. Remove the counterweights, which are strapped to the

INSTRUCTIONS

pallet under the fryer, from the pallet.

(Continued)

 

Do not drop. The counterweights weigh approximately 18 lbs. (8.1 kg) each. Handle with care, or personal injury could result.

8.Remove rear service cover.

9.Load the 7 weights into the counterweight assembly.

10.Replace rear service cover.

To avoid personal injury and assure safe operation of unit, rear service cover must be in place.

11.Cut warning tags from the lid assembly. The lid may now be unlatched.

12.Remove the accessories from inside the filter drain pan.

The fittings for installing the gas line are in a separate box, along with the accessories, in the filter drain pan.

13.Prepare the deadweight valve for operation

The metal shipping support is placed within the deadweight assembly housing to protect the deadweight orifice and deadweight during shipment. This support must be removed prior to installation and start-up.

a.Unscrew the deadweight cap.

b.Remove the deadweight.

c.Remove and discard the shipping support.

d.Clean the deadweight orifice with a dry cloth.

e.Carefully place deadweight over deadweight orifice. Replace deadweight cap, finger tight.

14.Remove the protective paper from the fryer cabinet. Clean exterior surface with a damp cloth.

2-2