Heath Zenith SL-5597 User Manual

0 (0)

Dual BriteMotion Sensor Light Control for Canadian Tire

Model SL-5597

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Dual Brite™ Timer.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Lamp

6 Screws

Holders

(3 sizes included)

Gasket

Cover

Plate Sensor

Light Control

 

 

2 Wire

 

 

Connectors

Mounting Bolt

Mounting Strap

 

 

 

 

Plastic Hanger

2 Lamps

Rubber Plug

 

 

(installed)

 

 

Requirements

The Light Control requires 120-volts AC.

If you want to use the Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

© 2003 DESA Specialty Products™

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

Auto

1, 5, 20 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put ON-TIME switch ON-TIME DUAL BRITE™

on the sensor bottom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to TEST and the Dual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off 3 6 Dusk to

TEST 1 5 20

Brite™ switch OFF.

 

 

 

 

 

 

 

Dawn

 

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

 

 

ON-TIME

or 20 minute position.

TEST 1 5 20

MANUAL MODE

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ONTIME switch in the 1, 5, or 20 position.

1 Second OFF

then...

... back on.

 

Mode Switching Summary

 

 

 

 

 

 

 

 

TEST

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 20 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

Dual Brite™ TIMER

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). If motion is sensed, the light turns on full bright for the ON-TIME (1,5, or 20 minutes) then returns to dim mode.

598-1038-03

Heath Zenith SL-5597 User Manual

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

CAUTION: To Avoid Fire Or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).

Use only T4 100W (max.), G8 tungsten halogen bipin 120 VAC lamps.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp

screw joint.

Controls

Clamp Screw

Rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION.

NOTE: When re-lamping, turn power off and let the fixture cool.

To remove lamp shade, loosen set screw 2 full turns with a small flat-head screwdriver. Turn shade counterclockwise and remove.

To remove bulb, pull straight out of fixture.

To replace bulb, push bulb pins into lamp socket. Check that the bulb is seated properly.

To reinstall lamp shade, place shade on fixture and align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install mounting strap to junction box using screws appropriate for your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route all fixture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors.

Black to Black White to White

Mounting

Strap

Rubber Plug

Mounting Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

MOUNT THE LIGHT CONTROL.

Place the Mounting Bolt through the front of the junction box cover. Push the small gasket hole over the Mounting Screw.

Make sure the wire connectors and wires are inside the junction box. Align the Mounting Screw with the center hole in the Mounting Strap. Secure the fixture to the Mounting Strap.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

Lamp Shade

Set Screw

Lock Nuts

Keep lamps at least 2" (51 mm) from the sensor and 2" (51 mm) from combustibles.

Adjust the lamp holders by loosening the lock nuts, but do not rotate the lamp holders more than 180° from the factory setting.

Adjust lamp shades by loosening the set screws several turns, turn shades counterclockwise and remove. Reinstall the shades in the desired position and tighten set screws.

2

598-1038-03

Clamp Screw
Ball
Joint
Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on or when switching modes wait 1 1/2 minutes.

Turn the RANGE control to the mid position, Dual Brite™ to OFF and the ON-TIME control to the TEST position.

MAX

 

 

 

 

B

O

ON - TIME

DUAL BRITE

 

 

O

 

 

 

T

S

 

 

MIN

 

 

 

 

TEST 1 5 2 0

OFF 3 6

DUSK TO

RANGE

 

 

MINUTES

HOUR

DAWN

Bottom of Sensor

Avoid aiming the sensor at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

240°

8 ft.

(2.4 m)

70 ft.

100 ft.

(21 m)

(30.5 m)

 

Boosted

Maximum

Maximum

Range

Coverage Angle

The control is most sensitive to motion across it.

 

 

 

 

 

 

 

 

 

Motion

 

 

 

 

Motion

 

 

 

 

 

 

 

 

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.

Keep the sensor at least 2" (51 mm) away from the lamps.

Adjust the RANGE as needed. Too much range may increase false triggering. Range Boost increases coverage up to 100 feet.

Secure the sensor head's aim

by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after

motion is detected (1, 5, or 20 minutes).

Set the DUAL BRITE™ switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Range . . . . . . . . . . . . . .

Sensing Angle . . . . . . . .

Electrical Load . . . . . . . .

Power Requirements. . .

Operating Modes . . . . . .

Time Delay . . . . . . . . . .

Dual Brite™ Timer . . . . .

Replacement lamp . . . .

Up to 70 ft. (21 m); 100 ft.(30.5 m) with Range Boost. [varies with surrounding temperature]

Up to 240°

Up to 200 Watts Maximum Incandescent (Up to 100 Watts Maximum each lamp holder.)

120 VAC, 60 Hz

TEST, AUTO and MANUAL MODE

1 , 5, 20 minutes

3, 6 hours, Dusk-to-Dawn T4 100W, G8 halogen bi-pin 120 VAC

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

598-1038-03

3

TROUBLESHOOTING GUIDE

If you experience a problem, follow this guide.

SYMPTOM

POSSIBLE CAUSE

 

 

 

Lights will

1.

Light switch is turned off.

not come

2.

Light is loose or burned out.

on.

3.

Fuse is blown or circuit breaker is turned

 

 

off.

 

4.

Daylight turnoff is in effect (recheck

 

 

after dark).

 

5.

Incorrect circuit wiring, if this is a new

 

 

installation.

 

6.

Re-aim the sensor to cover desired area.

 

 

 

Lights come

1.

Light Control may be installed in a

on in

 

relatively dark location.

daylight.

2.

Light Control is in Test. (Set control

 

 

switch to an ON-TIME position).

Lights come

1.

Light Control may be sensing small

on for no

 

animals or automobile traffic (re-aim

apparent

 

sensor).

reason.

2.

Range is set too high. (Reduce Range

 

 

setting).

 

3.

Dual Brite™ Timer is on.

 

 

 

Lights turn

1.

Sensor is in a relatively dark location.

off too late

 

(Relocate sensor, or use 3 hr or 6 hr

in Dusk-to-

 

setting).

Dawn

 

 

setting.

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

Lights stay

1.

A lamp is positioned too close to the

on continu-

 

sensor or pointed at nearby objects

ously.

 

that cause heat to trigger the sensor.

 

 

(Reposition the lamp away from the

 

 

sensor or nearby objects).

 

2.

Light Control is pointed toward a heat

 

 

source like an air vent, dryer vent, or

 

 

brightly-paintedheat-reflectivesurface.

 

 

(Reposition sensor. Reduce Range).

 

3.

Light Control is in Manual Mode.

 

 

(Switch to Auto).

 

 

 

Lights flash

1.

Heat or light from the lamps may be

on and off.

 

turning the Light Control on and off.

 

 

(Reposition the lamps away from the

 

 

sensor).

 

2.

Heat being reflected from other ob-

 

 

jects may be affecting the sensor.

 

 

(Reposition sensor).

 

3.

Light Control is in the Test mode and

 

 

warming up. (Flashing is normal un-

 

 

der these conditions. Turn Boost off).

 

 

 

Lights flash

1.

Sensor is detecting its own lights.

once, then

 

(Reposition lamps to keep area be-

stay off in

 

low the sensor relatively dark).

Manual Mode.

 

 

See your Canadian Tire retailer for warranty information.