Heath Zenith SL-5525 User Manual

0 (0)

Motion Sensing

Halogen Fixture

Model SL-5525

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Plastic Hanger

6 Screws

Gasket

(3 sizes included)

 

1 Halogen

 

Lamp

 

Sensor

 

3 Wire

 

Connectors

 

Mounting Strap Light Control

Mounting Bolt

 

Light Shield

Rubber Plug

 

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

© 2004 DESA Specialty Products™

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

Auto

1, 5, 10 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom ON-TIME of the sensor in the TEST position.

10 5 1 TEST

AUTO

ON-TIME

Put the ON-TIME switch in the 1, 5,

or 10 minute position.

10 5 1 TEST

MANUAL MODE

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

 

 

 

 

 

 

 

... back on.

 

 

 

 

 

 

 

 

Mode Switch Summary

 

 

 

 

 

 

 

TEST

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

1, 5, or 10 minutes

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second

 

 

 

 

 

 

 

then back on*

 

 

 

 

 

 

 

MANUAL MODE

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

595-5295-11

Heath Zenith SL-5525 User Manual

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.

CAUTION: To Avoid Fire Or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 1" (2.5 cm) from combustible materials. Do not aim at objects closer than 3 ft. (1 m).

Use only T3, 250W (max.) tungsten halogen 120 VAC lamps.

Note the position of the various parts of the fixture for the type of installation for your application and adjust the lamp head and sensor as shown below.

Wall Mount

Eave Mount

Lens Retainer

Light Shield, with opening at this side

Lens Retainer

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backingfromtheLightShieldandstickonasshownbelow.

For eave mount only:

Swing the sensor head towards the clamp screw

joint.

Controls

 

 

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Light Shield

Opening

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

BULB INSTALLATION.

When relamping, turn power off and let the fixture cool.

Remove glass cover and remove the old bulb by pushing the bulb towards the socket indicated on the metal reflector.

To insert the new bulb, follow the instructions printed on the metal reflector.

Check that the bulb is seated properly.

Reinstall the glass cover.

WIRE THE LIGHT CONTROL.

Turn the power to the lighting circuit off at the fuse or circuit breaker box.

Remove the existing light fixture.

Install mounting strap to junction box using screws appropriate for your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Thread all fixture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors.

Mounting Strap

 

Black to Black

White to White

 

Rubber

 

Plug

Mounting

Bolt

Gasket

Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

2

595-5295-11

Aim Sensor Higher for Long Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

180°

8 ft.

(2.4 m)

70 ft.

(21 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Motion

Motion

Loosen the clamp screw in

Clamp

the sensor ball joint and gen-

Screw

tly rotate the sensor.

 

Walk through the coverage

Ball

area noting where you are

Joint

when the lights turn on (also,

 

theLEDwillflashseveraltimes

 

when motion is detected).

 

Move the sensor head up,

 

down, or sideways to change

Aim Sensor

the coverage area. Keep the

Down for Short

sensor at least 1" (2.5 cm)

Coverage

away from the lamp.

 

Adjust the RANGE as needed.RANGEsettoohigh mayincreasefalsetriggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . . Up to 180°

Electrical Load . . . . . . . Up to 250 Watts Maximum Incandescent.

Power Requirements. . 120 VAC, 60 Hz

Operating Modes . . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . . 1, 5, 10 minutes Replacement lamp . . . T3, 250W (or less) halogen

120 VAC

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

 

Sensor

Least Sensitive

Most Sensitive

595-5295-11

3

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2.

Bulb is loose or burned out.

 

3.

Fuse is blown or circuit breaker is

 

 

turned off.

 

4.

Daylight turn-off is in effect (recheck

 

 

after dark).

 

5.

Incorrect circuit wiring, if this is a

 

 

new installation.

 

6.

Re-aim the sensor to cover desired

 

 

area.

 

 

 

Light comes on

1.

Light control may be installed in a

in daylight.

 

relatively dark location.

 

2.

Light control is in test. (Set control

 

 

switch to an ON-TIME position.)

 

 

 

Light comes on

1.

Light control may be sensing small

for no apparent

 

animals or automobile traffic (re-

reason.

 

aim sensor).

 

2.

Sensitivity is set too high. (Reduce

 

 

sensitivity.)

 

 

 

Lights flash

1.

Sensor is detecting its own light.

once, then stay

 

(Reposition lamp to keep area be-

off in Manual

 

low the sensor relatively dark.)

Mode.

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

Light stays on

1. The lamp is positioned too close to

continuously.

 

the sensor or pointed at nearby ob-

 

 

jects that cause heat to trigger the

 

 

sensor. (Reposition the lamp away

 

 

from the sensor or nearby objects.)

 

2.

Sensor is pointed toward a heat

 

 

source like an air vent, dryer vent, or

 

 

brightly-painted heat-reflective sur-

 

 

face. (Reposition sensor.)

 

3.

Control is in Manual Mode. (Set to

 

 

Auto.)

 

 

 

Light flashes

1.

Heat or light from the lamp may be

on and off.

 

turning the Light Control on and off.

 

 

(Reposition the lamp away from the

 

 

sensor.)

 

2.

Heat being reflected from other ob-

 

 

jects may be affecting the sensor.

 

 

(Reposition sensor.)

 

3.

Light Control is in the Test mode and

 

 

warming up. (Flashing is normal un-

 

 

der these conditions).

 

4.

If eave installation, Light Shield not

 

 

installed properly. (Install Light Shield

 

 

according to instructions.)

 

 

 

TECHNICAL SERVICE

Please call 1-800-858-8501 for assistance before returning product to store.

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™

ATTN: Technical Service Specialty Products P.O. Box 90004, Bowling Green, KY 42102-9004

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

TEN YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WAR-

RANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY

PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for warranty claims.

4

595-5295-11

Loading...
+ 8 hidden pages