Heath Zenith SL-5408-WH, SL-5408 User Manual

0 (0)

Motion Sensor Light

Control

As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. This product is ENERGY STAR® com- pliant when used with 120 Watt bulbs.

Model SL-5408

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

This package includes:

Lamp Holders

Cover

Plate 4 Mounting

Screws (2 sizes)

Sensor

Gasket

Light Control

2 Wire

Connectors

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

Auto

1, 5, 10 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom

ON-TIME

 

 

 

 

 

 

 

 

 

 

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5, or

 

ON-TIME

10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

 

 

 

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ONTIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

Requirements

The Light Control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.

© 2004 DESA Specialty Products™

Mode Switching Summary

 

TEST

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1, 5, or 10 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

595-5292-18

Heath Zenith SL-5408-WH, SL-5408 User Manual

INSTALLATION

WIRE THE LIGHT CONTROL.

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground.

Drill the holes needed to mount the backplate to the junction box.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Route the Light Control's wires through the large gasket hole.

Connect the junction box wires to the Light Control wires. Twist together and secure with a wire connector.

 

 

Black to

 

White to

 

Black

 

White

 

 

Gasket

2345678901234567890123

2345678901234567890123

Eave Mount

Wall Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Rotate the sensor head towards the clamp screw joint.

Control Switch

Joint Clamp

Then rotate the sensor head clockwise 180° so the controls face down.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and the junction box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone.

Avoid water damage and electrical shock - keep lamp holders below horizontal.

Keep lamps at least 1" (25 mm)

from the sensor.

Lock nuts

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

2

595-5292-18

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

ON-TIME

SENS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

 

MIN MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

110°

8 ft.

(2.4 m)

60 ft.

(18.3 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Motion

Motion

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the SENSITIVITY as needed. Too much sensitivity may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor Down for Short Coverage

Aim Sensor Higher for Long Coverage

Set the amount of TIME you

want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with surrounding temperature].

Sensing Angle . . . . . . Up to 110°

Electrical Load . . . . . . Up to 300 Watt Maximum Incandescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes Range . . . . . . . . . . . . Adjustable

DESA Specialty Products™ reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

595-5292-18

3

TROUBLESHOOTING GUIDE

SYMPTOM

 

POSSIBLE CAUSE

 

 

 

 

 

Lights will not come

1. Light switch is turned off.

on.

 

2. Flood light

is

loose or

 

 

 

burned out.

 

 

 

 

3.

Fuse is blown or circuit breaker is

 

 

 

turned off.

 

 

 

 

4.

Daylight turn-off is in effect (re-

 

 

 

check after dark).

 

 

 

5.

Incorrect circuit wiring, if this is a

 

 

 

new installation.

 

 

 

6.

Re-aim the sensor to cover de-

 

 

 

sired area.

 

 

Lights come

on

1. Light Control may be installed in

in daylight.

 

 

a relatively dark location.

 

 

2.

Light Control is in Test.

 

 

 

(Set control switch to an

 

 

 

ON-TIME position).

 

 

 

 

 

Lights come on for

1. Light Control

may

be sensing

no apparent

rea-

 

small animals or automobile traf-

son.

 

 

fic (re-aim sensor).

 

 

 

2.

Sensitivity is set too high. (Re-

 

 

 

duce sensitivity.)

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

Lights stay on

1. A flood lamp is positioned too close to

continuously.

the sensor or pointed at nearby ob-

 

jects that cause heat to trigger the

 

sensor. (Reposition the lamp away

 

from the sensor or nearby objects).

 

2. Light Control is pointed toward a heat

 

source like an air vent, dryer vent, or

 

brightly-painted heat-reflective sur-

 

face. (Reposition sensor).

 

3. Light Control is in Manual Mode.

 

(Switch to Auto.)

Lights flash on

1. Heat or light from the lamps may be

and off.

turning the Light Control on and off.

 

(Reposition the lamps away from the

 

sensor).

 

2. Heat being reflected from other ob-

 

jects may be affecting the sensor.

 

(Reposition sensor).

 

3. Light Control is in the Test mode and

 

warming up. (Flashing is normal un-

 

der these conditions).

 

4. Light may be leaking through the

 

floodlampreflectors.(Replacethelamps

 

with new high quality PAR 38 lamps).

 

 

TECHNICAL SERVICE

Please call 1-800-858-8501 for assistance before returning product to store.

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to: DESA Specialty Products™

ATTN: Technical Service Specialty Products P.O. Box 90004, Bowling Green, KY 42102-9004

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

TWO YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Proof of purchase is required for warranty claims.

4

595-5292-18

Loading...