Heath Zenith SH-5511 User Manual

0 (0)
Heath Zenith SH-5511 User Manual

Compact 150 Watt Motion

Sensing Halogen

Model SH-5511

Requirements

The light control requires 120-volts AC. Do not connect through a dimmer or other electronic switch.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

This package includes:

 

 

6 Mounting

 

 

Screws (3 sizes)

Cover

 

 

Plate

 

 

Sensor

 

3 Wire

Gasket

Connectors

 

Light Control

OPERATION

Mode:

On-Time:

Works: Day

Night

Test

5 Sec

x

x

Normal

1, 5, 10 min.

 

x

Manual

Until Dawn*

 

x

 

 

 

 

 

* resets to Auto Mode at dawn.

 

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the

ON-TIME

bottom of the sensor in the TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

ON-TIME

or 10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

Mounting Bolt

Mounting Strap

Rubber Plug

Plastic Hanger

Halogen

 

 

Bulb

MANUAL MODE

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

© 2008 HeathCo LLC

598-1159-06

Mode Switching Summary

TEST Move ON-TIME Switch

to 1, 5, or 10 minutes

 

AUTO

 

 

 

 

Flip light switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off for one second

 

 

 

 

 

 

 

 

then back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

INSTALLATION

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

CAUTION: The sensor must be mounted below the lamp housing for wall installations.

Eave Mount

Wall Mount

CAUTION to avoid fire or burn hazards:

Allow fixture to cool before touching. The bulb and fixture operate at high temperatures.

Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Rotate the sensor head towards the clamp screw joint.

Control Switch

Joint Clamp

Then rotate the sensor head clockwise 180° so the controls face down.

598-1159-06

Bulb Installation and Relamping

When relamping, turn power off and let the fixture cool.

Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb, push the bulb into the right socket so the bulb fits completely into the left socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

Mount the Light Control

Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

Wire the Light Control

RIGHT

WRONG

 

The halogen light must be

WARNING: Turn power off at circuit breaker

mounted horizontally (+/- 4°).

or fuse.

Remove the existing light fixture.

Strip about 5/8" insulation from the existing junction box wiring.

Route the light control’s wires through the large hole in the gasket.

Twistthejunctionboxwiresandfixturewirestogether as shown. Secure with wire connectors.

Mounting

White to White

 

Black to Black

 

Strap

Rubber

 

 

 

 

Plug

Mounting

Bolt

Gasket

Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.

598-1159-06

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the medium position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

Motion

Motion

 

Sensor

Least Sensitive

Most Sensitive

SENS

ON - TIME

MIN MAX

10 5 1 TEST

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the coverage area.Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the SENSITIVITY as needed. Too much sensitivity may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor Down for Short Coverage

Aim Sensor Higher for Long Coverage

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

8 ft.

(2.4 m)

60 ft.

(18.3 m)

 

 

 

110°

 

WARNING: Risk of fire. Do not aim the bulbs

 

 

 

 

 

at a combustible surface within 3 ft. (1 m).

 

 

 

Maximum Range

Maximum

 

Coverage Angle

598-1159-06

SPECIFICATIONS

Range. . . . . . . Up to 60 ft. (18.3 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 110°

Electrical Load. . . . Up to 150Watts Maximum tungsten

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range. . . . . . . Adjustable

Replacement lamp. . T 150W (or less) halogen 120 VAC

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2. Halogen lamp is loose or burned

 

 

out.

 

3.

Fuse is blown or circuit breaker is

 

 

turned off.

 

4.

Daylight turn-off is in effect (Recheck

 

 

after dark).

 

5.

Incorrect circuit wiring, if this is a new

 

 

installation.

 

6.

Not aimed correctly (Re-aim the

 

 

sensor to cover desired area).

 

 

Light comes on

1. Light control may be installed in a

in daylight.

 

relatively dark location.

 

2.

Light control is in TEST (Select 1, 5

 

 

or 10 minutes for AUTO time).

 

 

Light comes on

1. Light control may be sensing small

for no apparent

 

animals or automobile traffic (re-aim

reason.

 

sensor).

 

2.

Sensitivity is set too high (Reduce

 

 

sensitivity).

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

Light stays on

1. The halogen lamp is positioned too

continuously.

 

close to the light control's sensor or

 

 

pointed at nearby objects that cause

 

 

heat to trigger the sensor (Reposition

 

 

the lamp away from the sensor or

 

 

nearby objects).

 

2.

Lightcontrol'ssensorispointedtoward

 

 

a heat source like an air vent, dryer

 

 

vent,orbrightly-paintedheat-reflective

 

 

surface (Reposition sensor).

 

3.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

 

 

Light flashes

1.

Heat or light from the halogen lamp

on and off.

 

may be turning the light control on

 

 

and off (Reposition the lamp away

 

 

from the sensor).

 

2.

Heat being reflected from other

 

 

objects may be affecting the light

 

 

control (Re-aim sensor).

 

3.

Light control is in the TEST mode

 

 

and warming up (Flashing is normal

 

 

under these conditions).

 

 

 

598-1159-06

Technical Service

Please call 1-800-858-8501 (English speaking only) for assistance before returning product to store.

If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

HeathCo LLC

P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

TWO YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of two years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PUR-

POSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HeathCo LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT

LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.

598-1159-06