Heath Zenith SH-5411 User Manual

0 (0)

Motion Sensor

Light Control

Model SH-5411

Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

LED indicates motion was sensed (day or night).

This package includes:

Lamp Holders

2 Wire

Connectors

Cover

Sensor

Plate

 

Light Control

Gasket

4 Screws

(2 sizes included)

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.

OPERATION

Mode:

On-Time:

Works: Day

Night

 

 

 

 

Test

5 Sec

x

x

 

 

 

 

Normal

1, 5, 10 min.

 

x

 

 

 

 

Manual

Until Dawn*

 

x

 

 

 

 

 

* resets to Auto Mode at dawn.

 

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the

ON-TIME

bottom of the sensor in the TEST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position.

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

ON-TIME

or 10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

 

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

© 2008 HeathCo LLC

598-1157-05

Heath Zenith SH-5411 User Manual

Mode Switching Summary

TEST Move ON-TIME Switch

to 1, 5, or 10 minutes

 

AUTO

 

 

 

 

Flip light switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off for one second

 

 

 

 

 

 

 

 

then back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

INSTALLATION

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground. NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

Drill the holes needed to mount the backplate to the junction box.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Eave Mount

Wall Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

598-1157-05

Wire the Light Control

Mount the Light Control

WARNING:Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Route the light control’s wires through the large gasket hole.

Connect the junction box wires to the light control wires. Twist together and secure with a wire connector.

White to White

Gasket

Align the light control cover plate and the junction box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone.

Avoid water damage and electrical shock - keep lamp holders below horizontal.

Keep lamps at least 1" (25 mm)

from the sensor.

Lock nuts

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.When screwing in the floodlamps, do not overtighten.

Black to Black

598-1157-05

 

Clamp Screw
Ball
Joint
Aim Sensor Down for Short Coverage
Aim Sensor Higher for Long Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

NOTE:MeetstheENERGYSTAR® guidelineswhenused with 120 W Max bulbs.

Turn the RANGE control to the mid position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

ON-TIME

 

RANGE

ON-TIME

RANGE

 

10 5 1 TEST

MIN MAX

MIN MAX

10 5 1 TEST

 

MINUTES

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

180°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

Motion

Motion

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range. . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 180°

Electrical Load. . . . Up to 240 Watt Maximum Tungsten [Up to 120 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range. . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

598-1157-05

TROUBLESHOOTING GUIDE

SYMPTOM

 

POSSIBLE CAUSE

 

 

 

 

 

Lights will not come

1. Light switch is turned off.

on.

 

 

2. Flood light

is

loose or

 

 

 

 

burned out.

 

 

 

 

 

3.

Fuse is blown or circuit breaker

 

 

 

 

is turned off.

 

 

 

 

 

4.

Daylight turn-off is in effect (re-

 

 

 

 

check after dark).

 

 

 

 

5.

Incorrect circuit wiring, if this is a

 

 

 

 

new installation.

 

 

 

 

6.

Re-aim the sensor to cover de-

 

 

 

 

sired area.

 

 

Lights

come

on

1. Light control may be installed in

in daylight.

 

 

a relatively dark location.

 

 

 

2.

Light control is in Test.

 

 

 

 

(Set control switch to an

 

 

 

 

ON-TIME position).

 

Lights

come

on

1. Light control

may

be sensing

for no

apparent

 

small animals or automobile traf-

reason.

 

 

 

fic (re-aim sensor).

 

 

 

 

2.

Range is set too high .

 

 

 

 

(Reduce Range).

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

 

Lights stay on

1. A flood lamp is positioned too close to

continuously.

the sensor or pointed at nearby objects

 

that cause heat to trigger the sensor.

 

(Reposition the lamp away from the

 

sensor or nearby objects).

 

2. Light control is pointed toward a heat

 

source like an air vent, dryer vent, or

 

brightly-painted heat-reflective sur-

 

face. (Reposition sensor).

 

3. LightcontrolisinManualMode.(Switch

 

to Auto.)

Lights flash on

1. Heat or light from the lamps may be

and off.

turning the light control on and off.

 

(Reposition the lamps away from the

 

sensor).

 

2. Heat being reflected from other objects

 

may be affecting the sensor. (Reposi-

 

tion sensor).

 

3. Light control is in the Test mode and

 

warming up.(Flashing is normal under

 

these conditions).

 

4. Light may be leaking through the flood-

 

lampreflectors.(Replacethelampswith

 

new high quality PAR 38 lamps).

 

 

Technical Service

Please call 1-800-858-8501 (English speaking only) for assistance before returning product to store.

If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

HeathCo LLC

P.O. Box 90045, Bowling Green, KY 42102-9045 ATTN: Technical Service

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

TEN YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY,

REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PUR-

POSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HeathCo LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT

LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.