Motion Sensor
Light Control
Model SH-5105
Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 minutes and when used with 120 W Max bulbs.
Features
•DualZone™ Technology.
•Turns on lighting when motion is detected.
•Automatically turns lighting off.
•DualBrite® Timer.
•Photocell keeps the lighting off during daylight hours.
•LED indicates motion was sensed (day or night).
This package includes:
Bulb |
|
|
|
Holders |
|
Rubber Plug |
|
|
|
Plastic Hanger |
|
Cover |
|
|
|
Plate |
|
Sensor |
|
|
|
||
Light Control |
2 Wire |
||
Connectors |
|||
|
|
||
Mounting Bolt |
Mounting Strap |
||
|
|
Gasket |
|
|
|
6 Screws |
|
2 Shells |
|
(3 sizes included) |
Requirements
•The light control requires 120-volts AC.
•If you want to use Manual Mode, the control must be wired through a switch.
•Some codes require installation by a qualified electrician.
•This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
OPERATION
Mode: |
On-Time |
Works: Day |
Night |
Test |
5 Seconds |
x |
x |
Auto |
1, 5, or 20 Min |
|
x |
Manual |
To Dawn* |
|
x |
Accent |
3, 6 Hr, to Dawn |
|
x |
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.
TEST
Put ON-TIME switch |
ON-TIME |
DualBrite® |
||||||||
on the sensor bottom |
|
|
|
|
|
|
|
|
|
|
to TEST and the Dual- |
|
|
|
|
|
|
|
|
|
|
TEST 1 5 20 |
Off 3 6 Dusk to |
|||||||||
Brite® switch OFF. |
|
|
|
|
|
|
|
|
Dawn |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
AUTO
Put the ON-TIME switch in the 1, 5, |
ON-TIME |
|||||
|
|
|
|
|
|
|
or 20 minute position. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TEST 1 5 20 |
|||||
MANUAL MODE |
|
|
|
|
|
|
Manual mode only works at night because daylight returns the sensor to AUTO.
Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 20 position.
1 Second OFF
then...
... back on.
© 2008 HeathCo LLC |
598-1152-03 |
Mode Switching Summary
|
TEST |
|
|
|
|
Move ON-TIME Switch to |
||
|
||||||||
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
1, 5, or 20 minutes |
|
|
|
|
|
|
|
||
|
AUTO |
|
|
|
|
|
Flip light switch off |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
for one second then |
|
|
|
|
|
|
|
|
back on* |
MANUAL MODE |
|
|
|
|||||
|
|
|
|
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.
*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.
DualBrite® Timer
Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual.If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wall Mount |
Eave Mount |
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.
For eave mount only:
Swing the sensor head towards the clamp screw joint.
Controls
Clamp Screw
Then rotate the sensor head clockwise 180° so the controls face down.
Controls
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
598-1152-03
Wire the Light Control
WARNING: Turn power off at circuit breaker or fuse.
Remove the existing light fixture.
Install the mounting strap as shown using two screws that fit your junction box.
The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Route the light control’s wires through the large gasket holes.
Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.
Mounting |
|
|
|
Black to |
|
White to |
|
Strap |
Black |
|
White |
|
|
|
|
Rubber
Plug
Mounting
Bolt
Gasket
Junction box ground wire to green ground screw on fixture.
Mount the Light Control
Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.
Align the three slots in the decorative shell with the bulb holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.
Shell Slot
Push the rubber plug firmly into place.
If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.
To avoid water damage and electrical shock, keep bulb holders 30° below horizontal.
|
Keep bulbs at least |
|
1" (25 mm) from the |
Lock Nut |
sensor.Do not allow |
|
the bulbs to block |
Lens |
the lens. |
Adjust the bulb holders by loosening the lock nuts but do not rotate the bulb holders more than 180° from the factory setting.When screwing in the floodlamps, do not overtighten.
598-1152-03
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
NOTE: Meets the ENERGY STAR® guidelines when DualBrite® function is off and ON-TIME is 1 or 5 minutes and when used with 120 W Max bulbs.
Turn the RANGE control to the medium position (halfway between MIN and MAX), DualBrite® to OFF, and the ON-TIME control to the TEST position.
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.
|
|
|
|
|
|
|
|
Motion |
|
|
|
Motion |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DualZone™ |
Sensor |
DualZone™ |
|
|
|
Least Sensitive |
|
Most Sensitive |
|
|
P Z |
O |
||
|
|
E |
|
||
|
|
|
|
™ |
|
MAX |
|
ON-TIME |
DUAL BRITE™ |
||
|
O |
||||
|
B |
|
|
|
|
|
O |
|
|
|
|
|
S |
|
|
|
|
|
T |
|
|
|
|
MIN |
TEST 1 5 20 |
OFF 3 6 DUSK TO |
|||
RANGE |
|||||
|
MINUTES |
|
HOUR DAWN |
Bottom of Sensor
Avoid aiming the sensor at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.
|
|
240° |
15 ft. |
DualZone™ |
|
(4.6 m) |
||
DualZone™ |
70 ft. 100 ft. |
|
(21 m) (30.5 m) |
|
|
|
Boosted |
|
|
|
Maximum |
Maximum Range |
Coverage Angle |
Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (25 mm) away from the bulbs.
Adjust the RANGE as needed. RANGE set too high may increase false triggering.
Secure the sensor head by tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 20 minutes).
Set the DualBrite® switch to the amount of time after dusk you want the lights on at low level (Off, 3, 6 Hrs., Dusk-to-Dawn).
WARNING - Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).
NOTE: DualZone™ is a new zone of detection which was added as an option to select Heath®/Zenith motion sensing products. This feature adds a zone of detection under the motion sensor. DualZone™ requires no additional adjustment and operates in conjuction with the forward-looking sensor.
598-1152-03
SPECIFICATIONS
Range. . . . . . |
. Up to 70 ft. (21 m); 100 ft. |
|
(30.5m)withRangeBoost.[varies |
|
with surrounding temperature] |
Vertical Range. . . |
. Up to 15 ft. (4.6 m) |
Sensing Angle. . . |
. Up to 240° horizontal. Up to 80° |
|
Vertical |
Electrical Load. . . |
. Up to 300 Watt Maximum In- |
|
candescent [Up to 150 Watt |
|
maximum each bulb holder.] |
Power Requirements. 120 VAC, 60 Hz |
|
Operating Modes. . . TEST, AUTO and MANUAL |
|
|
MODE |
Time Delay . . . . |
. 1, 5, 20 minutes |
DualBrite® Timer. . |
. 3, 6 hours, Dusk-to-Dawn |
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM |
POSSIBLE CAUSE |
SOLUTION |
||
|
|
|
|
|
Lights will not come |
1. |
Light switch is turned off. |
1. |
Turn light switch on. |
on. |
2. |
Flood lamp is loose or burned out. |
2. |
Check flood lamp and replace if burned out. |
|
3. |
Fuse is blown or circuit breaker is turned off. |
3. |
Replace fuse or turn circuit breaker on. |
|
4. |
Daylight turn-off is in effect. |
4. |
Recheck after dark. |
|
5. |
Incorrect circuit wiring, if this is a new installation. |
5. |
Verify wiring is correct. |
|
6. |
Light control aimed in wrong direction. |
6. |
Re-aim light control to cover desired area. |
|
|
|
|
|
Lights come on in day- |
1. |
Light control may be installed in a relatively dark |
1. |
The fixture is operating normally under these condi- |
light. |
|
location. |
|
tions. |
|
2. |
Light control is in TEST. |
2. |
Set control switch to 1, 5, or 10 minutes. |
|
|
|
|
|
Lights come on for no |
1. |
Light control may be sensing small animals or auto- |
1. |
Re-aim light control. |
apparent reason. |
|
mobile traffic. |
|
|
|
2. |
Range is set too high. |
2. |
Reduce range. |
|
3. |
DualBrite® timer is on. |
3. |
The fixture is operating normally under these condi- |
|
|
|
|
tions. |
|
|
|
||
Lights turn off too late in |
Light control may be installed in a relatively dark loca- |
Relocate light control, or use 3 hr. or 6 hr. setting. |
||
Dusk-to-Dawn setting. |
tion. |
|
|
|
|
|
|
|
|
Lights stay on continu- |
1. |
A flood lamp is positioned too close to the light control |
1. |
Reposition the flood lamp away from the light control |
ously. |
|
or pointed at nearby objects that cause heat to trigger |
|
or nearby objects. |
|
|
the light control. |
|
|
|
2. |
The light control may be picking up a heat source |
2. |
Reduce range. |
|
|
like an air vent, dryer vent, or brightly painted, heat- |
|
|
|
|
reflective surface. |
|
|
|
3. |
Light control is in manual mode. |
3. |
Switch light control to AUTO. |
|
|
|
|
|
Lights flash on and off. |
1. |
Heat or light from the flood lamps may be turning the |
1. |
Reposition the flood lamp away from the light con- |
|
|
light control on and off. |
|
trol. |
|
2. |
Heat being reflected from other objects may be turn- |
2. |
Reposition light control. |
|
|
ing the light control on and off. |
|
|
|
3. |
Light control is in the TEST mode and warming up. |
3. |
Flashing is normal under these conditions. |
|
4. |
Light may be leaking through the flood lamp reflec- |
4. |
Replace the flood lamps with new high quality PAR |
|
|
tors. |
|
38 lamps. (Make sure the metal lamp protectors are |
|
|
|
|
installed). |
|
|
|
||
Lights flash once, then |
Light control is detecting its own lights. |
Reposition flood lamps to keep area below the light |
||
stay off in manual |
|
|
control relatively dark. |
|
mode. |
|
|
|
|
|
|
|
|
|
598-1152-03
Technical Service
Please call 1-800-858-8501 (English speaking only) for assistance before returning product to store.
If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport.com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
HeathCo LLC
P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.
No Service Parts Available for this Product
TEN YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.
For a period of ten years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.
This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF HeathCo LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.
598-1152-03