Heat & Glo LifeStyle LUX60 User Manual

Size:
2.21 Mb
Download

Owner’s Manual

Installation and Operation

Model(s):

LUX60

CAUTION

DO NOT DISCARD THIS MANUAL

• Important operating and

Read, understand and follow

Leave this manual with

maintenance instructions

these instructions for safe

party responsible for

included.

installation and operation.

use and operation.

DO DISCARDNOT

WARNING

If the information in these instructions is not followed exactly, a fire may result causing property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas:

-Do not try to light any appliance.

-Do not touch any electrical switch. Do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.

See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation and cool down.

Hot glass will cause burns.

• Do not touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as appliance.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other combustibles away.

This appliance requires installation of a decorative front with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trainedprofessionals, or technicians supervised by an NFI certified professional.

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

1

NATURAL GAS

Read this manual before installing or operating this appliance.

Please retain this owner’s manual for future reference.

A. Congratulations

Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces. The Heat & Glo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas fireplace will give you years of durable use and trouble-freeenjoyment. Welcome to the Heat & Glo family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your fireplace.

Model Name: ___________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on fireplace: _____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.

Type of Gas

Gas and Electric

Information

Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215th Street West, Lakeville, MN 55044

Not for use with solid fuel.

(Ne doit pas entre utilise avec un combustible solide).

Type of Gas(Sorte De Gaz): This appliance mustbe installed in accordance with local codes, if any;if not, follow ANSI Z223.1in the USAor CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglements locaux ou, en l’absence de tels reglements, selon les codes d’installation CAN/CGA-B149.)

ANSI Z21XX-XXXX· CSA2.XX-MXX· UL307B

Minimum Permissible Gas Supply for Purposes of Input Adjustment.

 

 

 

Approved Minimum(De Gaz) Acceptable

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Pressure (Pression)

 

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Manifold Pressure(Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Minimum Manifold Pressure(Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes

MADE IN USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN CANADA

 

Model:

XXXXXXXX

 

ALTITUDE:

0-0000FT.

0000-0000FT.

 

(Modele):

 

MAX. INPUT BTUH:

00,000

00,000

 

 

 

 

 

 

 

MIN. INPUT BTUH:

00,000

00,000

 

Serial

XXXXXXXX

 

ORIFICE SIZE:

#XXXXX

#XXXXX

 

 

 

(Serie):

 

Model Number

Serial Number

2

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoidedwill result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoidedcould result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A.

Congratulations

2

B.

Limited Lifetime Warranty

5

 

1 Listing and Code Approvals

 

 

A.

Appliance Certification

7

 

B.

Ceramic Glass Specifications

7

 

C.

BTU Specifications

7

 

D.

High Altitude Installations

7

 

E.

Noncombustible Materials Specification

7

 

F.

Combustible Materials Specification

7

 

G.

Electrical Codes

7

 

H.

Requirements for the Commonwealth

 

 

 

of Massachusetts

8

User Guide

2 Operating Instructions

A.

Gas Fireplace Safety

9

B.

Your Fireplace

9

C.

Clear Space

10

D.

Decorative Doors and Fronts

10

E.

Fixed Glass Assembly

10

F.

Operation of the LUX60

10

G.

Remote Operation

10

H.

Before Lighting Fireplace

11

I.IntelliFire Ignition System (IPI) Lighting

 

Instructions

12

J.

After Fireplace is Lit

13

K.

Frequently Asked Questions

13

3 Maintenance and Service

 

A.

Maintenance Tasks-Homeowner

14

B.

Maintenance Tasks-QualifiedService Technician

16

Installer Guide

4 Getting Started

 

A.

Typical Appliance System

20

B.

Design and Installation Considerations

21

C. Tools and Supplies Needed

21

D. Inspect Appliance and Components

21

5 Framing and Clearances

 

A.

Select Appliance Location

22

B.

Assemble Steel Stud Kit

22

C.

Construct the Appliance Chase

23

D.

Clearances

23

6

Termination Locations

 

 

A. Vent Termination Minimum Clearances

25

7

Vent Information and Diagrams

 

 

A.

Approved Pipe

27

 

B.

Vent Table Key

27

C.

Use of Elbows

27

D.

Measuring Standards

27

E.

Vent Diagrams

28

8 Vent Clearances and Framing

A.

Pipe Clearances to Combustibles

31

B.

Wall Penetration Framing

31

C.

Install the Ceiling Firestop

32

D.

Install Attic Insulation Shield

33

9 Appliance Preparation

A. Secure and Level the Appliance

34

10 Install Vent Pipe

A.

Assemble Vent Sections

35

B.

Assemble Slip Sections

36

C.

Secure the Vent Sections

36

D.

Disassemble Vent Sections

37

E.

Install Metal Roof Flashing

37

F.

Assemble and Install Storm Collar

38

G.

Install Vertical Termination Cap

39

H.

Heat Shield Requirements for Horizontal

 

 

Termination

39

I.

Install Horizontal Termination Cap

40

11 Shrouds

A.

HHT Shrouds

41

B.

Field Constructed Shrouds

41

12 Gas Information

A.

Gas Pressure

43

B.

Gas Connection

43

C.

High Altitude Installations

43

D.

Install Flame Solenoid

44

E.

Setting Flame Height/Manifold Pressure

44

13 Electrical Information

A.

Wiring Requirements

45

B.

Electrical Service and Repair

45

C. Junction Box Installation

46

14 Wall Finishing

A.

Standard 1/2 in. (13 mm) Sheetrock

47

B.

Additional Decorative Finishing up to 1 in.

 

 

(25 mm) Thick

48

C. Additional Decorative Finishing over 1 in.

 

 

(25 mm) Thick

48

15 Appliance Setup

A.

Remove Glass Assembly

49

B.

Clean the Appliance

49

C.

Air Shutter Access & Adjustment

49

D.

Install Glass Rock

51

16 Troubleshooting

A. IntelliFire (IPI) Ignition System

52

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

3

17 Reference Materials

 

A.

Appliance Dimension Diagram

54

 

B.

Vent Components Diagrams

55

C.

Service Parts

59

 

D.

Optional Components

64

 

E.

Contact Information

65

= Contains updated information.

4

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

B. Limited Lifetime Warranty

Hearth & Home Technologies Inc.

LIMITED LIFETIME WARRANTY

Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.

WARRANTY COVERAGE:

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.

WARRANTY PERIOD:

Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for parts and labor for covered components is produced in the following table.

The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

 

Warranty Period

 

HHT Manufactured Appliances and Venting

 

 

 

 

Parts

Labor

Gas

Wood

Pellet

EPA

Coal

Electric

Venting

Components Covered

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All parts and material except as

 

 

1 Year

X

X

X

X

X

X

 

X

covered by Conditions,

 

 

 

Exclusions, and Limitations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

listed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

 

 

 

Igniters, electronic components,

 

 

2 years

 

 

 

 

 

and glass

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

X

X

 

 

 

Factory-installedblowers

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

Molded refractory panels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 years

 

 

X

 

 

 

 

 

Firepots and burnpots

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 years

1 year

 

 

X

X

 

 

 

 

Castings and baffles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 years

3 years

 

X

X

X

 

 

 

 

Manifold tubes,

 

 

 

 

 

 

 

HHT chimney and termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

1 year

X

 

 

 

 

 

 

 

Burners, logs and refractory

 

 

years

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limited

3 years

X

X

X

X

X

 

 

 

Firebox and heat exchanger

 

 

Lifetime

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 Days

X

X

X

X

X

X

 

X

All replacement parts

 

 

 

beyond warranty period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See conditions, exclusions, and limitations on next page.

4021-645C12-29-10

 

 

 

 

 

 

 

 

Page 1 of 2

 

 

 

 

 

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

 

5

B. Limited Lifetime Warranty(continued)

WARRANTY CONDITIONS:

7KLV ZDUUDQW\ RQO\ FRYHUV ++7 DSSOLDQFHV WKDW DUH SXUFKDVHG WKURXJK DQ ++7 DXWKRUL]HG GHDOHU RU GLVWULEXWRU $ OLVW RI ++7 DXWKRUL]HG GHDOHUV LV DYDLODEOH RQ WKH ++7 EUDQGHG ZHEVLWHV

7KLV ZDUUDQW\ LV RQO\ YDOLG ZKLOH WKH ++7 DSSOLDQFH UHPDLQV DW WKH VLWH RI RULJLQDO LQVWDOODWLRQ

&RQWDFW \RXU LQVWDOOLQJ GHDOHU IRU ZDUUDQW\ VHUYLFH ,I WKH LQVWDOOLQJ GHDOHU LV XQDEOH WR SURYLGH QHFHVVDU\ SDUWV FRQWDFW WKH QHDUHVW ++7 DXWKRUL]HG GHDOHU RU VXSSOLHU $GGLWLRQDO VHUYLFH IHHV PD\ DSSO\ LI \RX DUH VHHNLQJ ZDUUDQW\ VHUYLFH IURP D GHDOHU RWKHU WKDQ WKH GHDOHU IURP ZKRP \RX RULJLQDOO\ SXUFKDVHG WKH SURGXFW

&KHFN ZLWK \RXU GHDOHU LQ DGYDQFH IRU DQ\ FRVWV WR \RX ZKHQ DUUDQJLQJ D ZDUUDQW\ FDOO 7UDYHO DQG VKLSSLQJ FKDUJHV IRU SDUWV DUH QRW FRYHUHG E\ WKLV ZDUUDQW\

WARRANTY EXCLUSIONS:

7KLV ZDUUDQW\ GRHV QRW FRYHU WKH IROORZLQJ

&KDQJHV LQ VXUIDFH ILQLVKHV DV D UHVXOW RI QRUPDO XVH $V D KHDWLQJ DSSOLDQFH VRPH FKDQJHV LQ FRORU RI LQWHULRU DQG H[WHULRU VXUIDFH ILQLVKHV PD\ RFFXU 7KLV LV QRW D IODZ DQG LV QRW FRYHUHG XQGHU ZDUUDQW\

'DPDJH WR SULQWHG SODWHG RU HQDPHOHG VXUIDFHV FDXVHG E\ ILQJHUSULQWV DFFLGHQWV PLVXVH VFUDWFKHV PHOWHG LWHPV RU RWKHU H[WHUQDO VRXUFHV DQG UHVLGXHV OHIW RQ WKH SODWHG VXUIDFHV IURP WKH XVH RI DEUDVLYH FOHDQHUV RU SROLVKHV

5HSDLU RU UHSODFHPHQW RI SDUWV WKDW DUH VXEMHFW WR QRUPDO ZHDU DQG WHDU GXULQJ WKH ZDUUDQW\ SHULRG 7KHVH SDUWV LQFOXGH SDLQW ZRRG SHOOHW DQG FRDO JDVNHWV ILUHEULFNV JUDWHV IODPH JXLGHV OLJKW EXOEV EDWWHULHV DQG WKH GLVFRORUDWLRQ RI JODVV

0LQRU H[SDQVLRQ FRQWUDFWLRQ RU PRYHPHQW RI FHUWDLQ SDUWV FDXVLQJ QRLVH 7KHVH FRQGLWLRQV DUH QRUPDO DQG FRPSODLQWV UHODWHG WR WKLV QRLVH DUH QRW FRYHUHG E\ WKLV ZDUUDQW\

'DPDJHV UHVXOWLQJ IURP IDLOXUH WR LQVWDOO RSHUDWH RU PDLQWDLQ WKH DSSOLDQFH LQ DFFRUGDQFH ZLWK WKH LQVWDOODWLRQ

 

LQVWUXFWLRQV RSHUDWLQJ LQVWUXFWLRQV DQG OLVWLQJ DJHQW LGHQWLILFDWLRQ ODEHO IXUQLVKHG ZLWK WKH DSSOLDQFH IDLOXUH WR

 

LQVWDOO WKH DSSOLDQFH LQ DFFRUGDQFH ZLWK ORFDO EXLOGLQJ FRGHV VKLSSLQJ RU LPSURSHU KDQGOLQJ LPSURSHU RSHUD-

 

WLRQ DEXVH PLVXVH FRQWLQXHG RSHUDWLRQ ZLWK GDPDJHG FRUURGHG RU IDLOHG FRPSRQHQWV DFFLGHQW RU LPSURSHUO\

 

LQFRUUHFWO\ SHUIRUPHG UHSDLUV HQYLURQPHQWDO FRQGLWLRQV LQDGHTXDWH YHQWLODWLRQ QHJDWLYH SUHVVXUH RU GUDIWLQJ

 

FDXVHG E\ WLJKWO\ VHDOHG FRQVWUXFWLRQV LQVXIILFLHQW PDNH XS DLU VXSSO\ RU KDQGOLQJ GHYLFHV VXFK DV H[KDXVW IDQV RU

 

IRUFHG DLU IXUQDFHV RU RWKHU VXFK FDXVHV XVH RI IXHOV RWKHU WKDQ WKRVH VSHFLILHG LQ WKH RSHUDWLQJ LQVWUXFWLRQV

 

LQVWDOODWLRQ RU XVH RI FRPSRQHQWV QRW VXSSOLHG ZLWK WKH DSSOLDQFH RU DQ\ RWKHU FRPSRQHQWV QRW H[SUHVVO\ DXWKRUL]HG

 

DQG DSSURYHG E\ ++7 PRGLILFDWLRQ RI WKH DSSOLDQFH QRW H[SUHVVO\ DXWKRUL]HG DQG DSSURYHG E\ ++7 LQ ZULWLQJ

 

DQG RU LQWHUUXSWLRQV RU IOXFWXDWLRQV RI HOHFWULFDO SRZHU VXSSO\ WR WKH DSSOLDQFH

 

1RQ ++7 YHQWLQJ FRPSRQHQWV KHDUWK FRPSRQHQWV RU RWKHU DFFHVVRULHV XVHG LQ FRQMXQFWLRQ ZLWK WKH DSSOLDQFH

 

$Q\ SDUW RI D SUH H[LVWLQJ ILUHSODFH V\VWHP LQ ZKLFK DQ LQVHUW RU D GHFRUDWLYH JDV DSSOLDQFH LV LQVWDOOHG

++7¶V REOLJDWLRQ XQGHU WKLV ZDUUDQW\ GRHV QRW H[WHQG WR WKH DSSOLDQFH¶V FDSDELOLW\ WR KHDW WKH GHVLUHG VSDFH ,QIRUPDWLRQ LV SURYLGHG WR DVVLVW WKH FRQVXPHU DQG WKH GHDOHU LQ VHOHFWLQJ WKH SURSHU DSSOLDQFH IRU WKH DSSOLFDWLRQ &RQVLGHUDWLRQ PXVW EH JLYHQ WR DSSOLDQFH ORFDWLRQ DQG FRQILJXUDWLRQ HQYLURQPHQWDO FRQGLWLRQV LQVXODWLRQ DQG DLU WLJKWQHVV RI

WKH VWUXFWXUH

This warranty is void if:

7KH DSSOLDQFH KDV EHHQ RYHU ILUHG RU RSHUDWHG LQ DWPRVSKHUHV FRQWDPLQDWHG E\ FKORULQH IOXRULQH RU RWKHU GDPDJLQJ FKHPLFDOV 2YHU ILULQJ FDQ EH LGHQWLILHG E\ EXW QRW OLPLWHG WR ZDUSHG SODWHV RU WXEHV UXVW FRORUHG FDVW LURQ EXEEOLQJ FUDFNLQJ DQG GLVFRORUDWLRQ RI VWHHO RU HQDPHO ILQLVKHV

7KH DSSOLDQFH LV VXEMHFWHG WR SURORQJHG SHULRGV RI GDPSQHVV RU FRQGHQVDWLRQ

7KHUH LV DQ\ GDPDJH WR WKH DSSOLDQFH RU RWKHU FRPSRQHQWV GXH WR ZDWHU RU ZHDWKHU GDPDJH ZKLFK LV WKH UHVXOW RI EXW QRW OLPLWHG WR LPSURSHU FKLPQH\ RU YHQWLQJ LQVWDOODWLRQ

LIMITATIONS OF LIABILITY:

7KH RZQHU¶V H[FOXVLYH UHPHG\ DQG ++7¶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

4021-645C12-29-10

Page 2 of 2

6

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

1 Listing and Code Approvals

A. Appliance Certification

MODELS: LUX60

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Fireplace Heater

STANDARD: ANSIZ21.88b-2008• CSA2.33b-2008

NOTICE: This installation must conform with local codes or, in the absence of local codes, with theNational Fuel Gas Code, ANSI Z223.1/NFPA 54, or theNatural Gas and Propane Installation Code, CSA B149.1.

A manufactured home (USA only) or mobile home OEM installation must conform with the (U.S.) Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 or, when such a standard is not applicable, the

Standard for Fire Safety Criteria for Manufactured Home Installation Sites and Communities, ANSI/NFPA 501A, in the United States, or the Mobile Homes Standard, CAN/CSA Z240 MH Seriesin Canada.

This appliance complies with the installation requirements for HUD.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Ceramic Glass Specifications

This appliance is equipped with 5 mm ceramic glass. Replace glass with 5 mm ceramic glass. Please contact your dealer for replacement glass.

C. BTU Specifications

LUX60 - IPI

NG

Max / Min Input Rate

60,000 / 40,000

Orifice Size - Outside (3)

#44 / .086

Orifice Size - Center (1)

#53 / .059

 

 

LP

 

Max / Min Input Rate

50,000 / 37,000

 

 

Orifice Size - Outside (3)

#56 / .046

Orifice Size - Center (1)

#72 / .025

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Noncombustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763shall be considered noncombustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, withNational Electric Code ANSI/NFPA 70-latest edition or theCanadian Electric

Code CSA C22.1.

A 110-120VAC circuit for this product must be protected withground-faultcircuit-interrupterprotection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

7

Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H. Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-upis installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property

owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-upmay be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half(1/2) in. in size,

“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identi-

fies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Commonwealth of Massachusetts requirements.

8

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

User Guide

2 Operating Instructions

A. Gas Fireplace Safety

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation and cool down.

Hot glass will cause burns.

• Do not touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in

same room as appliance.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other combustibles away.

If you expect that small children or vulnerable adults may come into contact with this fireplace, the following precautions are recommended:

Install a physical barrier such as:

-A decorative firescreen.

-Adjustable safety gate.

Install a switch lock or a wall/remote control with child protection lockout feature.

Keep remote controls out of reach of children.

Never leave children alone near a hot fireplace, whether operating or cooling down.

Teach children to NEVER touch the fireplace.

Consider not using the fireplace when children will be present.

Contact your dealer for more information, or visit: www. hpba.org/safety-information.

To prevent unintended operation when not using your fireplace for an extended period of time (summer months, vacations, trips, etc):

This appliance requires the installation of a decorative front with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

WARNING! Choking Hazard! Keep glass rock out of reach of children.

Turn off external gas cock.

B. Your Fireplace

WARNING! DO NOT operate fireplace before reading and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury.

Noncombustible

Zone

 

“L” Pieces-Facing

Fixed Glass Assembly

Section 3.A.

 

Section 2.F.

 

 

Hearth

 

 

(not required)

 

 

Clear Space

 

 

Section 2.D.

 

 

Remote

 

Figure 2.1 General Parts

Control

 

 

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11

9

C. Clear Space

WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2.

Avoid placing candles and other heat-sensitiveobjects on mantel or hearth. Heat may damage these objects.

 

Clear Space

 

3 ft (0.91 m)

 

in front of

 

appliance

Figure 2.2

Clear Space

D. Decorative Doors and Fronts

WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fireplace to overheat.

This appliance requires the installation of the SSF-LUX60-BK with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

For more information refer to the instructions supplied with your decorative door or front.

E. Fixed Glass Assembly

See Section 15.A.

F. Operation of the LUX60

This appliance is operated solely by remote control. Refer to Sect 2.G. Remote Operation.

G. Remote Operation

FCC Requirements

WARNING! Changes or modifications to this unit not expressly approved by the party responsible for

compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses , and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Contact the dealer or an experienced radio TV technician for help.

Canadian Equipment Requirements

This digital apparatus does not exceed the (Class A/ Class B) limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques (de la class A/de la class B) prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada.

This device complies with RSS-210of Industry and Science Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

10

Heat & Glo • LUX60 • 4062-116• Rev. G • 4/11