Heat & Glo LifeStyle LCOR-HV-IPI, ST-HV-IPI, PIER-HV-IPI, RCOR-HV-IPI User Manual

0 (0)

Owner’s Manual

Installation and Operation

Models:

Pier-HV-IPI

ST-HV-IPI

LCOR-HV-IPI

RCOR-HV-IPI

READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.

WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-What to do if you smell gas

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Printed in U.S.A. Copyright 2006

Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.

1.This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

In the Commonwealth of Massachusetts:

• installation must be performed by a licensed plumber or gas fitter;

See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com.

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

1

Safety and Warning Information

!before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

!Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has been

!under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

!THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by a

!qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

Always KEEP the appliance clear and free from

!combustible materials, gasoline, and other flammable vapors and liquids.

!NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.

Due to the high temperature, the appliance should

!be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition.

Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.READ and UNDERSTAND all instructions carefully

These units MUST use one of the vent systems

!described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.

This gas fireplace and vent assembly MUST be

!vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are

PROHIBITED.

INSPECT the external vent cap on a regular basis to

!make sure that no debris is interfering with the air flow.

!The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass

!door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

!The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

!DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is

!recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season.

!Any safety screen or guard removed for servicing must be replaced before operating this appliance.

!DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

2

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

Table of Contents

Í

Safety and Warning Information

.................................................. 2

Service Parts List .........................................................................

4

Approvals and Codes ................................................................

13

Í

Appliance Certification .................................................................................

13

Installation Codes ........................................................................................

13

High Altitude Installations .............................................................................

13

Requirements for the Commonwealth of Massachusetts ..............................

14

Getting Started ............................................................................

15

Introducing the Heat & Glo Gas Fireplaces ..................................................

15

Pre-install Preparation .................................................................................

15

Installing the Fireplace ...............................................................

19

Step 1. Locating the Fireplace ....................................................................

19

Step 2. Framing the Fireplace .....................................................................

20

Step 3. Installing the Vent System ..............................................................

23

A. Vent System Approvals .........................................................

23

B. Installing Vent Components ...................................................

30

Î C. Vent Termination ....................................................................

32

Step 4. Positioning, Leveling, and Securing the Fireplace ...........................

35

Step 5. The Gas Control System ................................................................

35

Step 6. The Gas Supply Line ......................................................................

36

Step 7. Gas Pressure Requirements ...........................................................

36

ÎStep 8. Wiring the Fireplace........................................................................

37

Step 9. Finishing .........................................................................................

40

Step 10. Installing Trim, Logs & Ember Material ..........................................

41

Installing the Trim ..........................................................................

41

Positioning the Logs ......................................................................

41

Shutter Settings ............................................................................

41

Glass Specifications ......................................................................

41

Preparing Electric Ember Bed and Lava Rock ...............................

41

Placing the Ember Material ...........................................................

43

Ember Light Bulb Replacement .....................................................

43

Step 11. Before Lighting the Fireplace ........................................................

44

Step 12. Lighting the Fireplace ...................................................................

44

After the Installation .....................................................................................

44

Maintaining and Servicing Your Fireplace ................................

45

Î= Contains updated information.

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

3

Service Parts

Pier-HV-IPI

 

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-03

 

Ending Manufacturing Date: ______

 

 

3

 

 

 

 

1

 

 

4

5

 

 

 

 

2

 

6 Log Assembly

 

 

 

 

 

 

Grate

 

 

 

Bar

4

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

Service Parts List (NG, LP)

PIER-HV-IPI

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

 

 

 

 

AVAILABLE

 

 

 

 

TO SHIP IN 24

 

 

 

 

HOURS

ITEM

DESCRIPTION

SERIAL #

PART NUMBER

Î

 

Burner Orifice NG (#33DMS)

 

582-833

Y

 

 

 

 

 

 

Burner Orifice LP (#50DMS)

 

582-850

Y

 

 

 

 

 

1

End Glass Assembly

 

GLA-MS

Y

 

 

 

 

 

2

Glass Door Assembly

 

GLA-6TROC

Y

 

 

 

 

 

3

Burner Assembly

 

2005-006

Y

 

 

 

 

 

4

Log Grate

 

2005-012

 

5

Side Refractory

 

SRV2005-730

 

6

Log Set Assembly

 

LOGS-MSR

Y

7

Log 1

 

SRV2005-701

 

8

Log 2

 

SRV2005-700

 

 

 

 

 

 

9

Log 3

 

SRV2005-702

 

10

Log 4

 

SRV2005-703

 

 

 

 

 

 

11

Log 5

 

SRV2005-704

 

 

 

 

 

 

12

Log 6

 

SRV2005-705

 

 

 

 

 

 

13

Log 7

 

SRV703-703

 

 

Lava Rock Bag

 

2005-790

 

 

 

 

 

 

 

Flue Restrictor

 

385-128

 

 

 

 

 

 

 

Teco-Sil, 5 lb. bag

 

700-790

 

 

 

 

 

 

 

Ember Mesh Assembly

 

2006-008

Y

 

Junction Box

 

4021-013

Y

 

 

 

 

 

 

Non-Combustible Board (side)

 

2006-136

 

 

 

 

 

 

 

Non-Combustible Board (end)

 

2006-137

 

 

3V Adaptor Plug

 

593-593A

Y

 

 

 

 

 

 

Battery Pack

 

593-594A

Y

 

 

 

 

 

 

Fiberglass Rope

 

060-455

 

 

 

 

 

 

 

Glass Latch Support Assembly

 

386-122A

Y

 

 

 

 

 

 

Mineral Wool

 

050-721

 

 

Conversion Kit NG

 

NGK-MS

Y

 

Conversion Kit LP

 

LPK-MS

Y

 

ACCESSORIES

 

 

 

 

Fan Kit

 

GFK-160A

 

 

Remote Control Kit

 

RC-SMART-HNG

 

 

Remote Control Kit

 

SMART-STAT-HNG

 

 

Remote Control - Multi-functional

 

RCT-MLT-HNG

 

 

Wall Switch, Multi-functional

 

WSK-MLT

 

 

Plug Adapator Kit (for WSK-MLT)

 

PLUG-ADP

 

 

Louvers with Mesh

 

MS-LOUVERS

 

 

Louvers with Mesh - End Panel

 

MS-LOUVERS-EP

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

5

Service Parts

ST-HV-IPI

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-03

 

Ending Manufacturing Date: ______

 

 

4

 

2

 

 

1

3

5

Log Assembly

 

 

 

Grate

 

 

Bar

6

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

AVAILABLE TO
SHIP IN 24
HOURS

Service Parts List (NG, LP)

ST-HV-IPI

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

ITEM

 

DESCRIPTION

SERIAL #

PART NUMBER

Î

 

 

Burner Orifice NG (#32DMS)

 

582-832

Y

 

 

 

 

 

 

 

 

Burner Orifice LP (#50DMS)

 

582-850

Y

 

 

 

 

 

 

1

 

Glass Door Assembly

 

GLA-6TROC

Y

 

 

 

 

 

 

2

 

Burner Assembly

 

2005-006

Y

 

 

 

 

 

 

3

 

Log Grate

 

2005-012

 

 

 

 

 

 

 

4

 

Side Refractory

 

SRV2005-730

 

 

 

 

 

 

 

5

 

Log Set Assembly

 

LOGS-MSR

Y

 

 

 

 

 

 

6

 

Log 1

 

SRV2005-701

 

 

 

 

 

 

 

7

 

Log 2

 

SRV2005-700

 

 

 

 

 

 

 

8

 

Log 3

 

SRV2005-702

 

 

 

 

 

 

 

9

 

Log 4

 

SRV2005-703

 

 

 

 

 

 

 

10

 

Log 5

 

SRV2005-704

 

 

 

 

 

 

 

11

 

Log 6

 

SRV2005-705

 

 

 

 

 

 

 

12

 

Log 7

 

SRV703-703

 

 

 

 

 

 

 

 

 

Lava Rock Bag

 

2005-790

 

 

 

 

 

 

 

 

 

Flue Restrictor

 

385-128

 

 

 

 

 

 

 

 

 

Teco-Sil, 5 lb. bag

 

700-790

 

 

 

 

 

 

 

 

 

Hood, black

 

SRV60-143-BK

 

 

 

 

 

 

 

 

 

Ember Mesh Assembly

 

2005-008

Y

 

 

 

 

 

 

 

 

Non-Combustible Board

 

2005-172

 

 

 

 

 

 

 

 

 

Junction Box

 

4021-013

Y

 

 

 

 

 

 

 

 

Fiberglass Rope

 

060-455

 

 

 

 

 

 

 

 

 

Glass Latch Support Assembly

 

386-122A

Y

 

 

 

 

 

 

 

 

Mineral Wool

 

050-721

 

 

 

 

 

 

 

 

 

3V Adaptor Plug

 

593-593A

Y

 

 

 

 

 

 

 

 

Battery Pack

 

593-594A

Y

 

 

 

 

 

 

 

 

Conversion Kit NG

 

NGK-MS

Y

 

 

Conversion Kit LP

 

LPK-MS

Y

 

ACCESSORIES

 

 

 

 

 

Fan Kit

 

GFK-160A

 

 

 

Remote Control Kit

 

RC-SMART-HNG

 

 

 

Remote Control Kit

 

SMART-STAT-HNG

 

 

 

Remote Control - Multi-functional

 

RCT-MLT-HNG

 

 

 

Wall Switch, Multi-functional

 

WSK-MLT

 

 

 

Plug Adapator Kit (for WSK-MLT)

 

PLUG-ADP

 

 

 

Louvers with Mesh

 

MS-LOUVERS

 

 

 

Louvers with Mesh - End Panel

 

MS-LOUVERS-EP

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

7

Service Parts

LCOR-HV-IPI

 

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-03

 

Ending Manufacturing Date: ______

1

6

2

3

15

4

5

 

7 Log Assembly

15

Part number list on following page.

8

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

Service Parts List (NG, LP)

LCOR-HV-IPI

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

 

 

 

 

 

AVAILABLE TO

 

 

 

 

 

SHIP IN 24

 

 

 

 

 

HOURS

ITEM

 

COMMON PARTS

SERIAL #

PART NUMBER

Î

 

 

 

 

 

 

 

 

Burner Orifice NG (#32DMS)

 

582-832

Y

 

 

 

 

 

 

 

 

Burner Orifice LP (#50DMS)

 

582-850

Y

 

 

 

 

 

 

1

 

End Glass Assembly

 

GLA-MS

Y

 

 

 

 

 

 

2

 

Glass Door Assembly

 

GLA-6TROC

Y

 

 

 

 

 

 

3

 

Burner Assembly

 

2005-006

Y

 

 

 

 

 

 

4

 

Log Grate

 

2005-012

 

 

 

 

 

 

 

5

 

Side Refractory

 

SRV2005-730

 

 

 

 

 

 

 

6

 

Refractory, Back

 

SRV2005-731

 

7

 

Log Set Assembly

 

LOGS-MSR

Y

 

 

 

 

 

 

8

 

Log 1

 

SRV2005-701

 

 

 

 

 

 

 

9

 

Log 2

 

SRV2005-700

 

 

 

 

 

 

 

10

 

Log 3

 

SRV2005-702

 

 

 

 

 

 

 

11

 

Log 4

 

SRV2005-703

 

 

 

 

 

 

 

12

 

Log 5

 

SRV2005-704

 

 

 

 

 

 

 

13

 

Log 6

 

SRV2005-705

 

 

 

 

 

 

 

14

 

Log 7

 

SRV703-703

 

 

 

 

 

 

 

 

 

Lava Rock Bag

 

2005-790

 

 

 

 

 

 

 

 

 

Flue Restrictor

 

385-128

 

 

 

 

 

 

 

 

 

Teco-Sil, 5 lb. bag

 

700-790

 

 

 

 

 

 

 

 

 

Ember Mesh Assembly

 

2006-008

 

 

 

 

 

 

 

 

 

Non-Combustible Board (side)

 

2006-136

 

 

 

 

 

 

 

 

 

Non-Combustible Board (end)

 

2008-114

 

 

 

 

 

 

 

 

 

Junction Box

 

4021-013

 

 

 

 

 

 

 

 

 

Fiberglass Rope

 

060-455

 

 

 

 

 

 

 

 

 

Glass Latch Support Assembly

 

386-122A

Y

 

 

 

 

 

 

 

 

Mineral Wool

 

050-721

 

 

 

 

 

 

 

 

 

3V Adaptor Plug

 

593-593A

Y

 

 

 

 

 

 

 

 

Battery Pack

 

593-594A

Y

 

 

 

 

 

 

 

 

Conversion Kit NG

 

NGK-MS

Y

 

 

Conversion Kit LP

 

LPK-MS

Y

 

ACCESSORIES

 

 

 

 

 

Fan Kit

 

GFK-160A

 

 

 

Remote Control Kit

 

RC-SMART-HNG

 

 

 

Remote Control Kit

 

SMART-STAT-HNG

 

 

 

Remote Control - Multi-functional

 

RCT-MLT-HNG

 

 

 

Wall Switch, Multi-functional

 

WSK-MLT

 

 

 

Plug Adapator Kit (for WSK-MLT)

 

PLUG-ADP

 

 

 

Louvers with Mesh

 

MS-LOUVERS

 

 

 

Louvers with Mesh - End Panel

 

MS-LOUVERS-EP

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

9

Heat & Glo LifeStyle LCOR-HV-IPI, ST-HV-IPI, PIER-HV-IPI, RCOR-HV-IPI User Manual

Service Parts

RCOR-HV-IPI

 

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-03

 

Ending Manufacturing Date: ______

6

5

15

1

4 3

2

7 Log Assembly

 

Part number list on following page.

Grate

Bar

 

 

10

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

Service Parts List (NG, LP)

RCOR-HV-IPI

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

 

 

 

 

 

AVAILABLE

 

 

 

 

 

TO SHIP IN 24

 

 

 

 

 

HOURS

ITEM

 

COMMON PARTS

SERIAL #

PART NUMBER

Î

 

 

 

 

 

 

 

 

Burner Orifice NG (#32DMS)

 

582-832

Y

 

 

 

 

 

 

 

 

Burner Orifice LP (#50DMS)

 

582-850

Y

 

 

 

 

 

 

1

 

End Glass Assembly

 

GLA-MS

Y

 

 

 

 

 

 

2

 

Glass Door Assembly

 

GLA-6TROC

Y

 

 

 

 

 

 

3

 

Burner Assembly

 

2005-006

Y

 

 

 

 

 

 

4

 

Log Grate

 

2005-012

 

 

 

 

 

 

 

5

 

Side Refractory

 

SRV2005-730

 

 

 

 

 

 

 

6

 

Refractory, Back

 

SRV2005-731

 

 

 

 

 

 

 

7

 

Log Set Assembly

 

LOGS-MSR

Y

 

 

 

 

 

 

8

 

Log 1

 

SRV2005-701

 

 

 

 

 

 

 

9

 

Log 2

 

SRV2005-700

 

 

 

 

 

 

 

10

 

Log 3

 

SRV2005-702

 

 

 

 

 

 

 

11

 

Log 4

 

SRV2005-703

 

 

 

 

 

 

 

12

 

Log 5

 

SRV2005-704

 

 

 

 

 

 

 

13

 

Log 6

 

SRV2005-705

 

 

 

 

 

 

 

14

 

Log 7

 

SRV703-703

 

 

 

 

 

 

 

 

 

Lava Rock Bag

 

2005-790

 

 

 

 

 

 

 

 

 

Flue Restrictor

 

385-128

 

 

 

 

 

 

 

 

 

Teco-Sil, 5 lb. bag

 

700-790

 

 

 

 

 

 

 

 

 

Ember Mesh Assembly

 

2006-008

Y

 

 

 

 

 

 

 

 

Non-Combustible Board (side)

 

2006-136

 

 

 

 

 

 

 

 

 

Non-Combustible Board (end)

 

2008-114

 

 

 

 

 

 

 

 

 

Junction Box

 

4021-013

Y

 

 

 

 

 

 

 

 

3V Adaptor Plug

 

593-593A

Y

 

 

 

 

 

 

 

 

Battery Pack

 

593-594A

Y

 

 

 

 

 

 

 

 

Fiberglass Rope

 

060-455

 

 

 

 

 

 

 

 

 

Glass Latch Support Assembly

 

386-122A

Y

 

 

 

 

 

 

 

 

Mineral Wool

 

050-721

 

 

 

 

 

 

 

 

 

Conversion Kit NG

 

NGK-MS

Y

 

 

Conversion Kit LP

 

LPK-MS

Y

 

ACCESSORIES

 

 

 

 

 

Fan Kit

 

GFK-160A

 

 

 

Remote Control Kit

 

RC-SMART-HNG

 

 

 

Remote Control Kit

 

SMART-STAT-HNG

 

 

 

Remote Control - Multi-functional

 

RCT-MLT-HNG

 

 

 

Wall Switch, Multi-functional

 

WSK-MLT

 

 

 

Plug Adapator Kit (for WSK-MLT)

 

PLUG-ADP

 

 

 

Louvers with Mesh

 

MS-LOUVERS

 

 

 

Louvers with Mesh - End Panel

 

MS-LOUVERS-EP

 

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

11

Service Parts

PIER-HV-IPI, ST-HV-IPI L&RCOR-HV-IPI

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-03

 

Ending Manufacturing Date: ______

13

14

9

8

7

10

11

12

 

1

 

 

6

 

 

 

 

 

 

 

 

 

2

3

4

5

 

 

 

 

 

 

 

 

AVAILABLE TO

 

 

 

 

 

 

SHIP IN 24

 

 

 

 

 

 

HOURS

ITEM

DESCRIPTION

 

SERIAL #

PART NUMBER

 

1

ON/OFF Rocker Switch

 

 

 

060-511

Y

2

ON/OFF Wire Assembly

 

 

 

060-521A

Y

3

Valve NG

 

 

 

750-500

Y

3

Valve LP

 

 

 

750-501

Y

4

Flexible Gas Connector

 

 

 

2005-009

Y

5

Module

 

 

 

593-592

Y

6

Wire Assembly

 

 

 

593-590A

Y

7

Ember Box Assembly

 

 

 

2005-114

Y

8

Pilot Assembly NG

 

 

 

385-510A

Y

8

Pilot Assembly LP

 

 

 

385-511A

Y

9

Pilot Bracket

 

 

 

2005-118

 

10

Gasket Orifice

 

 

 

2005-166

 

11

Valve Bracket

 

 

 

2005-120

 

12

Flex Ball Valve Assembly

 

 

 

302-320A

Y

13

Pilot Assembly Support

 

 

 

385-120

 

14

Ground Strap

 

 

 

385-512

 

 

Regulator, NG

 

 

 

NGK-DXV

Y

 

Regulator, LP

 

 

 

LPK-DXV

Y

 

Pilot Tube

 

 

 

446-301

Y

 

Orifice Spud NG

 

 

 

446-505

Y

 

Orifice Spud LP

 

 

 

446-517

Y

NOTE: Replacement bulbs to be supplied by homeowner. Recommended replacements: Sylvania Mini Candelabra 75 watts.

12

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

1Approvals and Codes

Appliance Certification

The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.

Certification

MODELS: PIER-HV-IPI, ST-HV-IPI, LCOR-HV-IPI, RCOR-HV-IPI

LABORATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace Heater STANDARD: ANSI Z21.88•CGA2.22•UL307B

Installation Codes

The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSAC22.1 Canadian Electric Code (in Canada).

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2,000 feet in the U. S. A. and in Canada.

When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4,500 feet (in Canada), check with local authorities.

Heat & Glo Quality Systems registered by SGS ICS

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

13

NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.

G.Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be ProductApproved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Commonwealth of Massachusetts requirements.

14

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. K • 11/06

Loading...