Heat & Glo LifeStyle 6000TV-OAK, 6000TV-OAK-IPI User Manual

0 (0)

Owner’s Manual

Installation and Operation

Model:

6000TV-OAK 6000TV-OAK-IPI

Underwriters

Laboratories Listed

READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.

WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-What to do if you smell gas

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.

1.This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

In the Commonwealth of Massachusetts:

installation must be performed by a licensed plumber or gas fitter;

a CO detector shall be installed in the room where the appliance is installed.

Printed in U.S.A. Copyright 2005

Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

Please contact your Heat & Glo dealer with any questions or concerns. For the number of your nearest Heat & Glo dealer, please call 1-888-427-3973.

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

1

SAFETY AND WARNING INFORMATION

READ and UNDERSTAND all instructions carefully

!before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

!Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has been

!under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

!THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by a

!qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

Always KEEP the appliance clear and free from

!combustible materials, gasoline, and other flammable vapors and liquids.

!NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.

Due to the high temperature, the appliance should

!be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.

These units MUST use one of the vent systems

!described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.

This gas fireplace and vent assembly MUST be

!vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are

PROHIBITED.

INSPECT the external vent cap on a regular basis to

!make sure that no debris is interfering with the air flow.

!The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass

!door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

!The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

!DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is

!recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season.

!Any safety screen or guard removed for servicing must be replaced before operating this appliance.

!DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

2

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

TABLE OF CONTENTS

 

Safety and Warning Information. ...............................................

2

Î Service Parts Lists. ....................................................................

4

Section 1: Approvals and Codes. ..............................................

8

Appliance Certification...................................................................

8

Installation Codes ..........................................................................

8

High Altitude Installations ...............................................................

8

Section 2: Getting Started .........................................................

9

Introducing the Heat & Glo Gas Fireplaces ...................................

9

Pre-installation Preparation ...........................................................

9

Section 3: Installing the Fireplace. ..........................................

11

Constructing the Fireplace Chase ...............................................

11

Step 1

Locating the Fireplace ..................................................

11

Step 2

Framing the Fireplace..................................................

12

Step 3

Negative Pressure Make-up Air ...................................

12

Step 4

Installing the Vent System............................................

13

 

A. Vent System Approvals ...........................................

13

 

B. System Components .............................................

13

 

C. Bedroom Installation in Canada .............................

14

 

D. Vent Termination ....................................................

14

Step 5

Positioning, Leveling, and

 

 

Securing the Fireplace.................................................

14

Step 6

The Gas Control Systems ...........................................

14

Step 7

The Gas Supply Line ...................................................

15

Step 8

Gas Pressure Requirements ......................................

15

ÎStep 9

Wiring the Fireplace ....................................................

16

Step 10

Finishing ......................................................................

18

Step 11

Installing Trim, Logs, and Ember Material....................

18

 

Installing the Trim .........................................................

18

 

Positioning the Logs ....................................................

18

 

Shutter Settings ...........................................................

18

 

Placing the Ember Material ..........................................

18

 

Glass Specifications .....................................................

19

Step 12

Before Lighting the Fireplace .......................................

19

Step 13

Lighting the Fireplace ..................................................

19

After the Installation .....................................................................

19

Section 4: Maintaining and Servicing Your Fireplace. ........

20

 

Î= Contains updated information.

 

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

3

Heat & Glo LifeStyle 6000TV-OAK, 6000TV-OAK-IPI User Manual

Service Parts

6000TV-OAK, 6000TV-OAK-IPI

 

 

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 4-01

 

Ending Manufacturing Date: ______

3 2

4

12

5

1 13

6 Log Set Assembly

9

7

 

8

10

11

Part number list on following page.

4

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

Service Parts List

6000TV-OAK, 6000TV-OAK-IPI

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts.

ITEM

COMMON PARTS

 

SERIAL #

PART NUMBER

 

 

 

 

 

1

Burner NG, LP

 

 

SRV383-338A

 

 

 

 

 

2

Glass Door Assembly

 

 

GLA-6TROC

 

 

 

 

 

3

Surround

PRE

002324021

385-130

POST 002324021

2026-108

 

 

4

Hood

 

 

SRV60-143-BK

 

 

 

 

 

5

Log Grate

 

 

383-360A

 

 

 

 

 

6

Oak Log Set Assembly

 

 

LOGS-6OAK

 

 

 

 

 

7

Log 1

 

 

SRV385-720

 

 

 

 

 

8

Log 2

 

 

SRV385-724

 

 

 

 

 

9

Log 3

 

 

SRV385-721

 

 

 

 

 

10

Log 4

 

 

SRV385-723

 

 

 

 

 

11

Log 5

 

 

SRV385-722

 

 

 

 

 

12

Combustion Board

 

 

385-401

 

 

 

 

 

 

Touch Up Paint

 

 

TUP-GBK-12

 

 

 

 

 

 

Glass Latch Assembly

 

 

386-122A

 

 

 

 

 

 

Mineral Wool Embers

 

 

050-721

 

 

 

 

 

 

Vermiculite Embers

 

 

MYSTIC-EMBERS

 

 

 

 

 

 

High Temp Limit Switch

 

 

066-531

 

 

 

 

 

 

Pilot Orifice NG

 

 

446-505

 

 

 

 

 

 

Pilot Orifice LP

 

 

446-517

 

 

 

 

 

 

STANDING PILOT IGNITION ONLY

 

 

 

13

Junction Box

PRE

002324021

100-250A

POST 002324021

4021-013

 

 

 

Thermocouple

 

 

446-511

 

 

 

 

 

 

Thermopile

 

 

060-512

 

 

 

 

 

 

Conversion Kit NG

 

 

NGK-6TVOC

 

 

 

 

 

 

Conversion Kit LP

 

 

LPK-6TVOC

 

 

 

 

 

 

INTERMITTENT PILOT IGNITION (IPI) ONLY

 

 

 

13

Junction Box

PRE

002324021

383-250A

POST 002324021

4021-013

 

 

 

Conversion Kit LP

 

 

LPK-6TVOC-IPI

 

 

 

 

 

 

ACCESSORIES

 

 

 

 

Trim Door Mesh

 

 

MESH-6000

 

 

 

 

 

 

Fan Kit

 

 

GFK-160A

 

 

 

 

 

 

Wall Switch Kit, Off-white

 

 

WSK-21

 

 

 

 

 

 

Wall Switch Kit, White

 

 

WSK-21-W

 

 

 

 

 

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

5

 

Service Parts

6000TV-OAK-IPI

 

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 4-01

 

 

Ending Manufacturing Date: ______

Intermittent Pilot Ignition

11

 

Valve Assembly

8

9

 

7

1

3

4

6

2 10

5

ITEM

 

DESCRIPTION

 

SERIAL #

PART NO.

1

Flex Ball Valve Assembly

 

 

 

302-320A

2

ON/OFF Rocker Switch

 

 

 

060-521A

 

 

 

 

 

 

3

Valve NG

 

 

 

750-500

 

 

 

 

 

 

3

Valve LP

 

 

 

750-501

 

 

 

 

 

 

4

Flexible Gas Connector

 

PRE

002324021

477-301A

 

POST 002324021

383-302A

 

 

 

5

Module

 

 

 

593-592

6

Wire Assembly

 

 

 

593-590A

7

Burner Orifice NG (#40C)

 

 

 

582-840

Burner Orifice LP (#53C)

 

 

 

582-853

 

 

 

 

8

Pilot Assembly NG

 

PRE

002324021

385-510A

 

POST 002324021

4021-025

 

 

 

8

Pilot Assembly LP

 

PRE

002324021

385-511A

 

POST 002324021

4021-026

 

 

 

9

Pilot Bracket

 

 

 

385-164

 

 

 

 

 

 

10

Valve Bracket

 

PRE

002324021

550-169

 

POST 002324021

2025-101

 

 

 

11

Ground Strap

 

 

 

2025-512

 

3V Adaptor Plug

 

 

 

593-593A

 

Battery Pack

 

 

 

593-594A

 

72" & 80" Wire Assembly

 

 

 

522-504A

6

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI • 384-900 Rev. N • 11/05

Loading...
+ 14 hidden pages