Heat & Glo LifeStyle 6000GLX-IPI-S--R User Manual

Size:
4.12 Mb
Download

Owner’s Manual

Installation and Operation

Models: 6000GLX-IPI-S6000GLX-IPI-R6000GLX-IPILP-S6000GLX-IPILP-R

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual with

and maintenance

these instructions for safe

party responsible for use

instructions included.

installation and operation.

and operation.

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-DO NOT try to light any appliance.

-DO NOT touch any electrical switch.DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard,

Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH, in Canada.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.

See Table of Contents for location of additional Commonwealth of Massachusetts requirements.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional.

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

1

Read this manual before installing or operating this appliance.

Please retain this owner’s manual for future reference.

A. Congratulations

Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces. The Heat & Glo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas fireplace will give you years of durable use and trouble-freeenjoyment. Welcome to the Heat & Glo family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your fireplace.

Model Name: ___________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on fireplace: _____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.

Type of Gas

Gas and Electric

Information

This product may be covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevets suivants): (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents pending (ou autres brevets americains et etrangers en attente).

Heat & Glo, a brand of Hearth & Home Technologies, Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

Not for use with solid fuel.

(Ne doit pas entre utilise avec un combustible solide).

Type of Gas (Sorte De Gaz): This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1

in the USA or CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglementsNATURAL GAS locaux ou, en l’absence de tels reglements, selon les codes d’installationCAN/CGA-B149.)

ANSI Z21XX-XXXX· CSA2.XX-MXX· UL307B

Minimum Permissible Gas Supply for Purposes of Input Adjustment.

 

Approved Minimum (De Gaz) Acceptable

0.0 in w.c.

(Po. Col. d’eau)

 

Maximum Pressure (Pression)

 

0.0 in w.c.

(Po. Col. d’eau)

 

Maximum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

Minimum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes

MADE IN USA

 

 

IN CANADA

 

Model:

XXXXXXXX

ALTITUDE:

0-0000FT.

0000-0000FT.

(Modele):

MAX. INPUT BTUH:

00,000

00,000

 

 

 

 

 

MIN. INPUT BTUH:

00,000

00,000

 

Serial

XXXXXXXX

ORIFICE SIZE:

#XXXXX

#XXXXX

 

 

(Serie):

Model Number

Serial Number

2

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoidedwill result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoidedcould result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

B. Limited Lifetime Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . 5

1 Listing and Code Approvals

A. Appliance Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 B. Glass Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 C. BTU Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 7 E. Non-CombustibleMaterials Specification. . . . . . . . . . . . . . 7 F. Combustible Materials Specification . . . . . . . . . . . . . . . . . 7 G. Electrical Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 H. Requirements for the Commonwealth of Massachusetts. . 8

User Guide

2 Operating Instructions

A. Gas Fireplace Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 B. Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 C. Fan Kit (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 D. Clear Space . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 E. Decorative Doors and Fronts . . . . . . . . . . . . . . . . . . . . . . 10 F. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 G. Remote Controls, Wall Controls and Wall Switches. . . . . 10 H. Before Lighting Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . 10 I. Lighting Instructions (IPI) . . . . . . . . . . . . . . . . . . . . . . . . . 11 J. After Fireplace is Lit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 K. Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . 12

3 Maintenance and Service

A. Maintenance Tasks-Homeowner . . . . . . . . . . . . . . . . . . .13

B. Maintenance Tasks-QualifiedService Technician . . . . . . 14

Installer Guide

4 Getting Started

A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16

B. Design and Installation Considerations . . . . . . . . . . . . . . 17

C. Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . 17

D. Inspect Appliance and Components. . . . . . . . . . . . . . . . . 17

5 Framing and Clearances

A. Selecting Appliance Location . . . . . . . . . . . . . . . . . . . . . . 18

B. Constructing the Appliance Chase . . . . . . . . . . . . . . . . . . 19

C. Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

D. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 20

6 Termination Locations

A. Vent Termination Minimum Clearances . . . . . . . . . . . . . . 21

7 Vent Information and Diagrams

A. Approved Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

B. Vent Table Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

C. Use of Elbows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

D. Measuring Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

E. Vent Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

8 Vent Clearances and Framing

A. Pipe Clearances to Combustibles . . . . . . . . . . . . . . . . . . 33 B. Wall Penetration Framing. . . . . . . . . . . . . . . . . . . . . . . . . 33 C. Install the Ceiling Firestop . . . . . . . . . . . . . . . . . . . . . . . . 34 D. Install Attic Insulation Shield. . . . . . . . . . . . . . . . . . . . . . . 35 E. Installing the Optional Heat-Zone-GasKit . . . . . . . . . . . . 35

9 Appliance Preparation

A. Choosing the Top or Rear Vent . . . . . . . . . . . . . . . . . . . . 36 B. Rear Vent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 C. Installing the Non-combustibleBoard. . . . . . . . . . . . . . . . 37 D. Securing and Leveling the Appliance . . . . . . . . . . . . . . . . 37

10 Installing Vent Pipe (DVP and SLP Pipe)

A. Assemble Vent Sections (DVP Pipe Only) . . . . . . . . . . . . 38 B. Assemble Vent Sections (SLP Pipe Only) . . . . . . . . . . . . 39 C. Assemble Slip Sections . . . . . . . . . . . . . . . . . . . . . . . . . . 39 D. Secure the Vent Sections. . . . . . . . . . . . . . . . . . . . . . . . . 40 E. Disassemble Vent Sections . . . . . . . . . . . . . . . . . . . . . . . 40 F. Install Decorative Ceiling Components (SLP only). . . . . . 41 G. Install Metal Roof Flashing. . . . . . . . . . . . . . . . . . . . . . . . 42 H. Assemble and Install Storm Collar . . . . . . . . . . . . . . . . . . 42 I. Install RF4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 J. Install Vertical Termination Cap . . . . . . . . . . . . . . . . . . . . 44 K. Install Decorative Wall Components (SLP only). . . . . . . . 44 L. Heat Shield Requirements for Horizontal Termination . . . 44 M. Install Horizontal Termination Cap (DVP and SLP Pipe) . 45

11 Gas Information

A. Fuel Conversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

B. Gas Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

C. Gas Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

D. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . 46

12 Electrical Information

A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 B. Intellifire Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 47 C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 47 D. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 48 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 49 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 49

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

3

13 Finishing

A. Mantel and Wall Projections. . . . . . . . . . . . . . . . . . . . . . . 50

B. Facing Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

C. Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

14 Appliance Setup

A. Remove Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . 52 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 52 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 E. Install the Refractory . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 F. Ember Placement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 54 H. Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 I. Install the Mesh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 J. Install Trim and/or Surround. . . . . . . . . . . . . . . . . . . . . . . 57 K. Air Shutter Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57

15 Troubleshooting

A. Intellifire Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . 58

16 Reference Materials

A. Appliance Dimension Diagram. . . . . . . . . . . . . . . . . . . . . 60

B. Vent Components Diagrams . . . . . . . . . . . . . . . . . . . . . . 61

C. Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68

D. Contact Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72

= Contains updated information.

4

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

B. Limited Lifetime Warranty

Hearth & Home Technologies LIMITED WARRANTY

Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.

Warranty Period

 

HHT Manufactured Appliances and Venting

 

 

 

 

 

 

 

 

 

 

 

Components Covered

Parts

Labor

Gas

Wood

Pellet

EPA

Electric

 

Venting

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

All Parts and Material Except as

1 Year

X

X

X

X

X

 

X

covered by Conditions, Exclusion,

 

 

 

 

 

 

 

 

 

and Limitations listed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

 

 

 

Igniters, Electronic Components,

 

 

 

 

 

 

 

and Glass

2 years

 

 

 

 

 

 

 

X

X

X

X

 

 

 

Blowers

 

 

 

 

 

 

 

 

X

 

 

 

 

 

Molded Refractory Panels

 

 

 

 

 

 

 

 

 

3 years

 

 

X

 

 

 

 

Firepots

 

 

 

 

 

 

 

 

 

 

5 years

3 years

 

 

X

X

 

 

 

Castings & Baffles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Firebox, HHT Chimney,

7 years

3 years

 

X

X

X

 

 

 

Termination & Heat

 

 

 

 

 

 

 

 

 

Exchanger

 

 

 

 

 

 

 

 

 

 

10 years

1 year

X

 

 

 

 

 

 

Burners, Logs & Refractory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limited

1 year

X

 

 

 

 

 

 

Firebox & Heat Exchanger

Lifetime

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

90 Days

X

X

X

X

X

 

X

All Replacement Parts

 

 

 

 

 

 

 

 

See Conditions, Exclusions, and limitations.

9-01-08

 

 

 

 

 

 

 

 

 

 

CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY

This warranty applies to the original owner and is transferable up to two years from date of purchase to the new homeowner, provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance remains in its original place of installation.

The maximum amount recoverable under this warranty is limited to the purchase price of the product.

In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.

Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty.

Page 1 of 2

4021-645A09-01-08

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

5

B. Limited Lifetime Warranty (continued)

This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered by this warranty.

Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to this noise are not covered by this warranty.

HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identification label furnished with the appliance; (2) installation which does not comply with local building codes; (3) shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure or handling devices such as exhaust fans or forced air furnaces or other such causes; (5) use of fuels other than those specified in the operating instructions; (6) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT; and/or (7) modification of the appliance not expressly authorized and approved by HHT in writing.

This warranty does not apply to non-HHTventing components, hearth components or other accessories used in conjunction with the installation of this product.

This warranty is void if the appliance has been over-firedor operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or there is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.

HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship during the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the defective component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.

Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY SPECIFIED ABOVE.

This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all warranties currently in existence.

If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier.

Page 2 of 2

4021-645A09-01-08

6

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

1 Listing and Code Approvals

A. Appliance Certification

MODELS: 6000GLX-IPI-R,6000GLX-IPI-S,6000GLX-IPILP-R,6000GLX-IPILP-S

LABORATORY: Underwriters Laboratories, Inc. (UL)TYPE: Direct Vent Gas Appliance HeaterSTANDARD: ANSIZ21.88-2000•CSA2.33-M98•UL307B

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSIZ223.1-latestedition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemental room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Glass Specifications

This appliance is equipped with 5 mm ceramic glass. Replace glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass.

C. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

Size

U.S. (0-2000FT) or Canada(2000-4500FT)

BTUH

BTUH

(DMS)

 

 

 

 

 

6000GLX-IPI-R(NG)

US

40,000

18,700

39

53 (2)

 

 

 

6000GLX-IPI-S(NG)

CANADA

36,000

16,830

40

 

54 (2)

 

 

 

 

6000GLX-IPILP-R

US

36,000

16,500

54

68 (2)

 

 

 

6000GLX-IPILP-S

CANADA

32,400

14,850

55

 

69 (2)

 

 

 

 

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-CombustibleMaterials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, withNational Electric Code ANSI/NFPA 70-latest edition or theCanadian Electric Code CSA

C22.1.

A 110-120VAC circuit for this product must be protected withground-faultcircuit-interrupterprotection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

7

Note: The following requirements reference various Massachusetts and national codes not contained in this document.

H.Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-upis installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-upmay be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half(1/2) in. in size,“GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Commonwealth of Massachusetts requirements.

8

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

2 Operating InstructionsUser Guide

A. Gas Fireplace Safety

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

If you expect that small children or vulnerable adults may come into contact with this fireplace, the following precautions are recommended:

Install a physical barrier such as:

-A decorative firescreen.

-Adjustable safety gate.

Install a switch lock or a wall/remote control with child protection lockout feature.

Keep remote controls out of reach of children.

Never leave children alone near a hot fireplace, whether operating or cooling down.

Teach children to NEVER touch the fireplace.

Consider not using the fireplace when children will be present.

Contact your dealer for more information, or visit: www. hpba.org/staysafe.

To prevent unintended operation when not using your fireplace for an extended period of time (summer months, vacations, trips, etc):

Remove batteries from remote controls.

Turn off wall controls.

Unplug 3 volt adapter plug and remove batteries on IPI models.

B. Your Fireplace

WARNING! DO NOT operate fireplace before reading and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury.

DECORATIVE DOORS

(NOT SHOWN)

SECTION 2.E.

FIXED GLASS ASSEMBLY

(NOT SHOWN)

SECTION 14.H.

MANTEL

FAN KIT

SECTION 2.C

HEARTH

CLEAR SPACE

SECTION 2.D.

Figure 2.1 General Operating Parts

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08

9

C. Fan Kit (optional)

If desired, a fan kit may be added. Contact your dealer to order the correct fan kit.

D. Clear Space

WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2.

Avoid placing candles and other heat-sensitiveobjects on mantel or hearth. Heat may damage these objects.

 

3

FT.

CLEAR

 

 

 

 

IN

 

 

 

FRONT OFSPACE

 

 

 

FIREPLACE

Figure 2.2

Clear Space

 

E. Decorative Doors and Fronts

WARNING! Risk of Fire! Install ONLY doors or fronts approved by Hearth & Home Technologies. Unapproved doors or fronts may cause fireplace to overheat.

This fireplace has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the fireplace with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

For more information refer to the instructions supplied with your decorative door or front.

F. Fixed Glass Assembly

See Section 14.H.

G.Remote Controls, Wall Controls and Wall Switches

Follow the instructions supplied with the control installed to operate your fireplace:

For safety:

Install a switch lock or a wall/remote control with child protection lockout feature.

Keep remote controls out of reach of children.

See your dealer if you have questions.

H. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified service technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire or Asphyxiation! DO NOT operate fireplace with fixed glass assembly removed.

10

Heat & Glo • 6000GLX-IPI-S/-R,6000GLX-IPILP-S/-R2101-900Rev. Q • 11/08