Heat & Glo LifeStyle 550TRSI-AUF User Manual

Size:
12.94 Mb
Download

Owner’s Manual

Installation and Operation

Models: 550TRSI-AUF550TRSILP-AUF

SAI Global

Ref No GSCS20163 SANS 1539:2008

AS4553:2008

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual

and maintenance

these instructions for safe

party responsible for

instructions included.

installation and operation.

and operation.

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury, or death.

DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE.

DO NOT SPRAYAEROSOLS IN THE VICIN-

ITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

What to do if you smell gas

-DO NOT try to light any appliance.

-DO NOT touch any electrical switch.DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fi re department.

Installation and service must be performed by a qualifi ed installer, service agency, or the gas supplier.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fi replace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other fl ammable materials.

DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.

Keep clothing, furniture, draperies and other fl ammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fi xed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

This is a room sealed appliance and no other ventilation is required than what is provided.

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

1

PLEASE READ THIS MANUAL BEFORE INSTALLING

AND USING THIS APPLIANCE.

MODELS:550TRSI-AUF,550TRSILP-AUF

ARE SAI GLOBAL APPROVED FOR

NATURALGAS, PROPANE OR BUTANE AS A BALANCED FLUE HEATER.

Refer to the appliance data plates for gas consumptions and pressures.

Installation of this appliance should only be carried out by an authorized person in accordance with the manufacturer’s instructions. Appliance is to be installed in full compliance with the National Gas

Installation Standard AS5601, the manufacturer’s instructions, and any local authorities’ requirements for gas, electrical and building regulations.

This appliance and its components are tested and safe when installed in accordance with this Installation Manual. Report to your dealer any parts damaged in shipment, specifically check glass condition.

The gas logs and flue system components are in separate packages. Read all instructions before starting installation and follow these instructions carefully during

installation to ensure maximum benefit and safety. Failure to follow them will void your warranty and may present a fire hazard.

The Heat & Glo, a brand of Hearth & Home Technologies Inc. warranty will be voided by, and Heat & Glo, a brand of Hearth &

Home Technologies Inc. disclaims any responsibility for the following actions:

Installation of any damaged heater or flue system component

Modification of the heater or balanced flue system installation other than as instructed by Heat & Glo, a brand of Hearth & Home Technologies Inc.

Improper positioning of the gas logs or the glass door

Installation and/or use of any component part not manufactured or approved by Heat & Glo, brand of Hearth & Home

Technologies Inc., not withstanding any independent testing laboratory or other party approval of such component part or accessory.

It is the responsibility of the professionals involved with the service and installation of the appliance to test the operation of the appliance before leaving the installation site.

IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty. Save this manual for future reference.

Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215th Street West, Lakeville, MN 55044

Copyright 2012 • Printed in U.S.A.

2

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

 

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference.

A. Congratulations

Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces. The Heat & Glo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas fireplace will give you years of durable use and trouble-freeenjoyment. Welcome to the Heat & Glo family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your fireplace.

Model Name:____________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on fireplace:______________________

Dealership purchased from:_ _______________________________ Dealer Phone:_ __________________________

Notes:_ _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.

Type of Gas

SAI Global Certification Nº:

SAMPLE

DMS (mm)

Model Number

Serial Number

xxxx-xxx

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

3

B. SANS Compliance

FOR YOUR SAFETY

This appliance is designed to operate on LPG

IF YOU SMELL GAS:

Turn off as supply at bottle

Extinguish all naked fl ames

Do not operate any electrical appliances

Ventilate the area

Check for leaks as detailed in this manual

If odor persist, contact your dealer or gas supplier immediately.

BURN-BACK(FIRE IN BURNER TUBE OR CHAMBER)

In the event of a burn-back,where the fl ame burns back to the jet, immediately turn off the gas supply at the control valve on the panel.

After ensuring the fl ame is extinguished, wait for 1 minute and re-lightthe appliance in the normal manner. Should the appliance again burn back, close the control valve and call a service technician. Do not use the appliance again until the service technician has declared that it is safe to do so.

GAS-PRESSUREREGULATOR

This appliance requires an operating pressure of 2.8 kPa at the appliance. A suitable LPG regulator that complies with the requirements of SAN 1237 must be installed.

IMPORTANT INFORMATION FOR THE USER

This appliance may only be installed by a registered LP Gas Installer.

All registered installers are issued with a card carrying their registration number. Ask to be shown the card before allowing the installation work to commence and make a note of the Installer QCC number. Upon completion of the installation, the installer is required to explain the operational details of the appliance together with the safety instructions. You will be asked to sign acceptance of the installation and be provided with a completion certifi cate. You should only sign for acceptance of the installation when the installation is completed to your satisfaction.

Note that your invoice is required in the event that you wish to make a guarantee claim.

Novida Testing Service

Liquefi ed Petroleum

Safe Appliance

Gas Safety Association

Verifi cation

of Southern Africa

 

SANS 1539:2008

IMPORTANT INFORMATION FOR THE INSTALLER

This appliance may only be installed by a registered LP Gas Installer with the Liquefi ed Petroleum Gas Association of Southern Africa. The appliance must be installed in accordance with the requirements of SANS 10087-1and any fi re department regulations and/or local bylaws applicable to the area.

If in doubt, check with the relevant authority before undertaking the installation.

Upon completion of the installation you are required to fully explain and demonstrate to the user the operational details and safety practices applicable to the appliance and the installation.

4

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

 

Safety Alert Key:

DANGER! Indicates a hazardous situation which, if not avoidedwill result in death or serious injury.

WARNING! Indicates a hazardous situation which, if not avoidedcould result in death or serious injury.

CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE: Used to address practices not related to personal injury.

Table of Contents

A. Congratulations. . . . . . . . . . . . . . . .

.

3

D. Mantel and Wall Projections. . . . . . . . . . . .

23

B. SANS Compliance . . . . . . . . . . . . . . .

.

4

6 Termination Locations

 

C. Limited Lifetime Warranty. . . . . . . . . . . . .

 

. 7

 

1 Listing and Code Approvals

 

 

A. Vent Termination Minimum Clearances. . . . . . .

. 24

 

 

7 Vent Information and Diagrams

 

A. Appliance Certification. . . . . . . . . . . . . .

 

10

 

B. Gas Pressure Requirements. . . . . . . . . . .

. 10

A. Approved Pipe. . . . . . . . . . . . . . . . .

26

C. High Altitude Installations. . . . . . . . . . . . .

 

10

B. Vent Table Key. . . . . . . . . . . . . . . . .

26

D. Non-CombustibleMaterials Specification. . . . . . . . . . . .

. 10

C. Use of Elbows . . . . . . . . . . . . . . . . .

26

E. Combustible Materials Specification . . . . . . . .

. 10

D. Measuring Standards. . . . . . . . . . . . . .

. 26

F. Electrical Codes. . . . . . . . . . . . . . . .

. 10

E. Vent Diagrams. . . . . . . . . . . . . . . . .

26

User Guide

2 Operating Instructions

A.

Gas Fireplace Safety. . . . . . . . . . . . . .

. 11

B.

Your Fireplace . . . . . . . . . . . . . . . . .

11

C.

Fan Kit. . . . . . . . . . . . . . . . . . . .

12

D.

Clear Space. . . . . . . . . . . . . . . . . .

12

E.

Decorative Doors and Fronts. . . . . . . . . . .

. 12

F.

Fixed Glass Assembly. . . . . . . . . . . . . .

12

G. Remote Controls, Wall Controls and Wall Switches. . . 12

H. Before Lighting Fireplace. . . . . . . . . . . . .

12

I.

Lighting Instructions (IPI). . . . . . . . . . . . .

13

J.

Control Module Operation. . . . . . . . . . . .

. 14

K.

After Fireplace is Lit. . . . . . . . . . . . . . .

15

L.

Frequently Asked Questions . . . . . . . . . . .

. 15

3 Maintenance and Service

A. Maintenance Tasks-Homeowner. . . . . . . . . .16

B. Maintenance Tasks-QualifiedService Technician . . . . 17

Installer Guide

4 Getting Started

A.Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 18

B.Design and Installation Considerations. . . . . . . . 19

C.

Tools and Supplies Needed. . . . . . . . . . . .

19

D.

Inspect Appliance and Components. . . . . . . . .

19

5 Framing and Clearances

A.

Selecting Appliance Location. . . . . . .

.

.

.

.

. 20

B.

Constructing the Appliance Chase. . . . .

.

.

.

.

. 21

C.

Clearances. . . . . . . . . . . . . .

.

.

.

.

. 21

8 Vent Clearances and Framing

A.

Pipe Clearances to Combustibles. . . . . . . . .

. 38

B.

Wall Penetration Framing. . . . . . . . . . . . .

38

C.

Install the Ceiling Firestop. . . . . . . . . . . .

. 39

D.

Install Attic Insulation Shield. . . . . . . . . . . .

40

E.

Installing the Optional Heat-Zone®-240VKit . . . . .

. 40

9 Appliance Preparation

A.

Top Vent. . . . . . . . . . . . . . . . .

.

.

. 41

B.

Rear Vent. . . . . . . . . . . . . . . . .

.

.

42

C.

Installing the Non-combustibleBoard. . . . . . . . . . .

. .

. . . 43

D.

Securing and Leveling the Appliance. . . . . .

.

.

. 43

E.Covers Removal For Servicing. . . . . . . . . . . . . . . . . . . . . 44

F.Components Removal For Service . . . . . . . . . 44

G.

Parts Replacement. . . . . . . . . . . . . . .

44

H.

Adjustments And Replacement Parts. . . . . . . .

. 44

I.

Install Trim and/or Surround. . . . . . . . . . . .

44

J.

Air Shutter Setting. . . . . . . . . . . . . . .

. 44

10 Installing Vent Pipe (DVP and SLP Pipe)

A.Assemble Vent Sections (DVP Pipe Only). . . . . . . 45

B.Assemble Vent Sections (SLP Pipe Only). . . . . . . 46

C.

Assemble Slip Sections. . . . . . . . . . . . .

. 46

D.

Secure the Vent Sections. . . . . . . . . . . . .

47

E.

Disassemble Vent Sections. . . . . . . . . . . .

47

F.

Install Support Brackets. . . . . . . . . . . . .

. 48

G. Install Firestops. . . . . . . . . . . . . . . .

. 48

H. Flue Termination. . . . . . . . . . . . . . . .

. 49

I.

Heat Shield Requirements for Horizontal Termination. . 50

J.

Install Metal Roof Flashing. . . . . . . . . . . .

. 50

K.

Assemble and Install Storm Collar. . . . . . . . .

. 51

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

5

L. Install Vertical Termination Cap. . . . . . . . . . . 51

11 Gas Information

A.

Gas Pressure Requirements. . . . . . .

.

.

.

.

. 52

B.

Gas Connection. . . . . . . . . . . .

.

.

.

.

. 52

12 Electrical Information

A. Wiring Requirements. . . . . . . . . . . . . . . 54

B.IntelliFire Plus™ Ignition System Wiring . . . . . . . 54

C.Optional Accessories Requirements . . . . . . . . . 54

D.

Blower . . . . . . . . . . . . . . . . . . . .

55

E.

Control Module Operation. . . . . . . . . . . .

. 55

13 Finishing

A.

Mantel and Wall Projections. . . . . . . . . . . .

63

B.

Facing Material. . . . . . . . . . . . . . . . .

63

14 Appliance Setup

A. Remove Fixed Glass Assembly. . . . . . . . . .

. 64

B. Remove the Shipping Materials. . . . . . . . . .

. 64

C. Clean the Appliance. . . . . . . . . . . . . . .

64

D.Accessories. . . . . . . . . . . . . . . . . . 64

E.Log Placement Instructions. . . . . . . . . . . . 65

15 Troubleshooting

A. IntelliFire Plus™ Ignition System. . . . . . . . . . 68

16 Reference Materials

A. Appliance Dimension Diagram. . . . . . . . . . .

70

B. Maintenance Tasks . . . . . . . . . . . . . . .

71

C. Vent Components Diagrams . . . . . . . . . . .

. 72

D. Service Parts. . . . . . . . . . . . . . . . .

. 77

E. Contact Information. . . . . . . . . . . . . . .

80

= Contains updated information.

6

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

 

C. Limited Lifetime Warranty

AUSTRALIAN WARRANTY INFORMATION

Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below.

Hearth & Home Technologies Inc (HHT)

7571 215th Street West, Lakeville, MN 55044

0011-1-651-345-1777

www.heatnglo.com

HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorised dealer.

HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture.

After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period, HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its obligations under this manufacturer’s warranty by replacing the product itself or refunding the verified purchase price of the product itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty is subject to conditions, exclusions and limitations as described below.

Warranty coverage begins on the date of original purchase. In the case of new home construction, coverage under this manufacturer’s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent, authorised HHT dealer/ distributor, whichever occurs earlier. The warranty period for this manufacturer’s warranty shall commence no later than 24 months following the date of product shipment from HHT, regardless of the installation or occupancy date. The manufacturer’s warranty period for parts and labour for covered components is produced in the following table.

The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet and coal appliances. These time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.

Warranty Period

 

Heat & Glo Manufactured Appliances and Venting

 

 

 

 

 

 

 

 

 

 

 

 

 

Components Covered

Parts

Labor

Gas

Wood

Pellet

EPA

Coal

Electric

Venting

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Year

X

X

X

X

X

X

X

 

All Parts and Material Except

 

as covered by Conditions,

 

 

 

 

 

 

 

 

 

Exclusion, and Limitations listed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

X

X

 

 

 

Igniters, Electronic

 

 

 

 

 

 

 

Components, and Glass

2 years

 

 

 

 

 

 

 

 

X

X

X

X

X

 

 

 

Factory-installedblowers

 

 

 

 

 

 

 

 

X

 

 

 

 

 

 

Molded refractory panels

 

 

 

 

 

 

 

 

 

 

3 years

 

 

X

 

 

 

 

 

Firepots and burnpots

 

 

 

 

 

 

 

 

 

 

 

2000-645(1-12)

 

 

 

 

 

 

 

 

Page 1 of 3

 

 

 

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

7

Warranty Period

 

Heat & Glo Manufactured Appliances and Venting

 

 

 

 

 

 

 

 

 

 

 

Components Covered

Parts

Labor

Gas

Wood

Pellet

EPA

Coal

Electric

Venting

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 years

1 years

 

 

X

X

 

 

 

Castings & baffles

 

 

 

 

 

 

 

 

 

 

7 years

3 years

 

X

X

X

 

 

 

Manifold tubs HEAT & GLO

 

 

 

 

chimney and termination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 years

1 year

X

 

 

 

 

 

 

Burners, logs and refractory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limited

3 year

X

X

X

X

X

 

 

Firebox and heat exchanger

Lifetime

 

 

 

 

 

 

 

 

 

 

 

 

90 Days

X

X

X

X

X

X

X

All Replacement Parts

beyond warranty period

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OTHER RIGHTS

The HHT manufacturer’s warranty is in addition to other rights and remedies that you may have under Australian law.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality

and the failure does not amount to a major failure.

WARRANTY CONDITIONS AND EXCLUSIONS:

The HHT manufacturer’s warranty only covers HHT appliances that are purchased through an HHT authorised dealer or distributor. A list of HHT authorised dealers is available on the HHT branded websites.

This warranty is only valid while the HHT appliance remains at the site of original installation.

WARRANTY EXCLUSIONS:

This HHT manufacturer’s warranty does not cover the following:

Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under warranty.

Damage to printed, plated, or enamelled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.

Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, light bulbs, batteries and the discoloration of glass.

Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to this noise are not covered by this warranty.

Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-upair supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the appliance.

2000-645(1-12)Page 2 of 3

8

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

 

Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance.

Any part of a pre-existingfireplace system in which an insert or a decorative gas appliance is installed.

Removal, installation, reinstallation, set up or any other costs associated with a claim including travel and shipping charges for parts

HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness of the structure.

This warranty is void if:

The appliance has been over-firedor operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals.Over-firingcan be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, cracking and discoloration of steel or enamel finishes.

The appliance is subjected to prolonged periods of dampness or condensation.

There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.

HOW TO CLAIM

To make a claim against this warranty, contact your local distributor during regular business hours. See addresses below for a dealer nearest you. (Vic) Pty Ltd ACN 005 872 159 (Jetmaster).

Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product.

Check with Jetmaster in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this manufacturers’ warranty.

HHT and Jetmaster will assess your claim. HHT or Jetmaster may need to inspect the product as part of the assessment of your claim. If the product requires inspection, HHT or Jetmaster will discuss with you the best way for this to occur.

To make a claim under this manufacturer’s warranty, you must be able to prove when you purchased the product. The easiest way to do this is through your original proof of purchase, for example your invoice or receipt. However, if you do not have your original proof of purchase HHT or Jetmaster may accept other evidence of the date of purchase.

Melbourne

Perth

Sydney

Jetmaster

Fireplace Corner

Jetmaster

444 Swan Street

277 Lord Street

10 Martin Avenue

Richmond 3121

East Perth 6000

Arncliff 2205

(03) 9429-5573

(08) 9228-2600

(02) 9597-7222

2000-645(1-12)

Page 3 of 3

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12

9

1 Listing and Code Approvals

A. Appliance Certification

MODELS: 550TRSI-AUF,550TRSILP-AUF

LABORATORY: SAI Global

TYPE: Gas Space Heating Appliance

STANDARD: AS4553-2008

The Heat & Glo gas appliances discussed in this Installer’s Guide have been tested to certification standards and listed by the applicable laboratories.

This appliance must be installed in accordance with the rules in force.

NOX Class 5 for G20, NOX Class 5 for G31

C. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 ft. (610 m) elevation:

Reduce input rate 4% for each 1000 ft. (305 m) above 2000 ft. (610 m).

D. Non-CombustibleMaterials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763shall be considered non-combustible materials.

B. Gas Pressure Requirements

WARNING! Risk of Explosion! An in-line regulator

MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve.

Pressurerequirementsfor550TRSI-AUFand550TRSILP-AUF fireplaces are shown in table below.

Two taps are provided on the right hand side of the gas control for a test gauge connection to measure the inlet and outlet pressures.

The fireplace and its individual shut-offvalve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures in excess of 60 mbar or 6 kPa.

If the fireplace must be isolated from the gas supply piping system by closing an individual shut-offvalve, it must be of thehandle-lesstype.

E. Combustible Materials Specification

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

F. Electrical Codes

All electrical safety testing has been done following the EN 60335-2-102standard. Local codes apply.

 

Natural Gas

Propane

Inlet Gas Pressure

1.13

- 3.40 kPa

2.75 - 3.40 kPa

Outlet (Manifold) Gas Pressure

.80

- .95kPa

2.36 - 2.61 kPa

Maximum Gas Consumption

28 MJ/h

26 MJ/h

Burner Injector

DMS 40 (2.49 mm)

.057 DMS (1.45 mm)

Pilot Injector

 

.0121

0.0181

An in-lineregulator MUST be installed if the gas pressure exceeds3.40 kPa. Failure to install a regulator could damage valve.

10

Heat & Glo • 550TRSI-AUF,550TRSILP-AUF2079-980Rev. N • 5/12