SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-10LQA13
HSU-15LQA13
HSU-10LQAB13
HSU-15LQAB13 HSU-09LQA03/R2(DB)
HSU-12LQA03/R2(DB) HSU-09LQA13/R2(DB)-WT HSU-09LQA13/R2(DB)-BK HSU-12LQA13/R2(DB)-WT
HSU-12LQA13/R2(DB)-BK HSU-12LEK03/R2(DB)
HSU-18LEK03/R2(DB) HSM24HEK03/R2(DB)
AS12GS1ERA
AS18GS1ERA
AS12GB2LAA HSU-10VEK03 HSU-13VEK03 HSU-18VEK03 HSU-24VEK03 AS05GA1LAA AS09GA1LAA AS12GB1LAA
AS18GD1LAA HSU-19CXAR3N HSU-19CXBW3N
HSU-09CK3W3N HSU-09LEK03-Y3 HSU-09CK6G2N HSU-12LEK03-Y3 HSU-09CK6B2N HSU-18LEK03-Y3 HSU-12CK3W3N HSU-24LEK03-Y2 HSU-12CKCS3N HSU-09LEK03/R2(DB) HSU-12CK6G2N HSU-24LEK03/R2(DB) HSU-12CK6B2N HSU-10LIN13 HSU-12CKAG3N HSU-09LTS14 HSU-12CKAB3N HSU-12LTS14 HSU-18CK3W3N HSU-18LTS14 HSU-18CK6B2N HSU-24LTS14 HSU-18CK6G2N HSU-07LEK03 HSU-18CKBS3N
HSU-15CKBS5N
HSU-18CKBS5N
HSU-18CKAB3N
HSU-18CKAG3N
HSU-15CKAG5N
HSU-18CKCS3N
HSU-24CK6B2N
HSU-13CXAS5N
HSU-13CXAS3N
HSU-13CXAR3N
HSU-13CXBW3N
HSU-19CXBW5N
HSU-24CXAS3N
HSU-19CXAS5N
HSU-19CXAS3N
Contents
PARTS AND FUNCTIONS |
|
|
|
|
2 |
|||||
|
|
|
|
|||||||
OPERATION |
|
|
|
|
3 |
|||||
|
|
|
|
|||||||
MAINTENANCE |
|
|
|
6 |
||||||
|
|
|
||||||||
CAUTIONS |
|
|
|
7 |
||||||
|
|
|
||||||||
TROUBLE SHOOTING |
|
|
8 |
|||||||
|
|
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
0010564364
Parts and Functions
|
|
Indoor Unit |
|
Remote controller |
||
|
|
|
||||
|
|
|
|
|
|
|
Inlet |
|
|
|
|
Air Purifying |
||
|
|
|
|
|
Filter |
Anion |
|
Inlet |
|
|
|
|
generator |
||
|
|
|
|
(inside) |
|||
grille |
|
|
|
|
|||
|
|
|
|
Vertical blade |
|||
|
|
|
|
|
|||
|
|
|
|
|
(adjust left and |
||
Nano-Aquo |
|
|
|
|
right air flow) |
||
Generator |
Outlet |
Horizontal flap |
|
||||
inside |
(adjust up and down air flow |
||||||
|
|
||||||
|
|
Don't adjust it manually) |
|||||
Display board |
|
||||||
|
|
|
|
|
|||
Aureole |
|
|
|
TEMP display |
|||
Display mode the aureole display different |
|
||||||
colour when setting different function |
|
|
|||||
COOL: blue |
|
FAN: yellow |
|
|
|||
AUTO: white DRY: cyan |
Nano-Aquo : green |
||||||
|
|
Inlet |
Air Purifying Filter (inside) |
||||
Inlet grille |
|
|
|
|
|
|
|
Outlet |
|
|
|
|
|
|
|
Horizontal flap |
|
Vertical blade |
|
Emergency |
|||
|
|
Switch |
|||||
(adjust up and down air flow |
(adjust left and |
Display board |
|
||||
Don't adjust it manually) |
right air flow) |
|
|||||
Display board |
1 |
2 |
3 |
4 |
5 |
1Signal receiver hole
2ON/OFF display
3Ambient temp.display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed.
4TIMER ON\OFF display TIMER ON-OFF display
SLEEP display
Note to the power failure resume: press the sleep button ten times in five seconds
and enter function after hearing four sounds.And press the sleep button ten times within five
seconds and leave this function after hearing two sounds.
5 COOL\HEAT\Dry\AUTO display
|
1 |
Inlet |
4 Air Purifying Filter (inside) |
|||
2 Inlet grille |
|
|
|
8 |
||
|
|
|
Emergency |
|||
|
|
|
|
|
||
|
|
|
|
|
Switch |
|
3 |
Outlet |
|
|
|
9 |
|
5 |
Anion generator |
6 Vertical blade |
12 |
10 |
||
11 |
||||||
|
(inside) |
(adjust left and |
|
|||
7 |
Horizontal flap |
|
13 |
|||
|
right air flow) |
|
||||
(adjust up and down air flow |
|
|
|
Don't adjust it manually)
9 Power indicator (Lights up when unit starts.)
10 Timer mode indicator
(Lights up whenTimer operation is selected.)
11 Operation mode indicator
(lights up when the compressor is on.)
12 Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived.)
13 Ambient temp display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference.
Actual inlet grille may vary from the one shown in the manual according to the product purchased
2
1 |
|
|
6 |
6. TIMER OFF display |
2 |
|
|
|
TIMER ON display |
|
|
7 |
7. TEMP display |
|
|
|
|
||
3 |
|
|
|
8. Additional functions display |
4 |
|
|
|
Supplemented |
|
|
|
electrical |
|
|
|
|
Operation mode QUIET SLEEP heating HEALTH TURBO |
|
5 |
|
|
8 |
Remote controller |
|
|
9. TURBO/QUIET button |
||
9 |
|
|
|
|
10 |
TURBO/QUIET |
|
18 |
10. FAN button |
|
|
19 |
11. COOL button |
|
11 |
|
|
12. SWING LEFT/RIGHT button |
|
|
|
20 |
||
|
|
|
13. FAN SPEED button |
|
12 |
|
|
|
|
SWING |
|
21 |
14. HEALTH display |
|
|
|
|||
13 |
|
|
15. SLEEP display |
|
|
|
|
||
14 |
|
|
22 |
16. LOCK button |
HEALTH |
SLEEP |
|
17. LIGHT button |
|
15 |
ON |
OFF |
23 |
Control the lightening and extinguishing |
|
TIME |
TIME |
|
|
16 |
|
|
24 |
of the indoor LED display board. |
|
|
|
18. POWER/SOFT display |
|
17 |
|
|
25 |
|
|
|
19. DRY button |
||
|
|
|
||
|
|
|
|
20. TEMP display |
|
|
|
|
21.SWING UP/DOWNbutton |
1. Mode display |
|
22. TIMER OFF/ON displa |
||
Operation mode |
AUTO COOL DRY |
FAN |
23.HEALTH AIR FLOW button |
|
Remote controller |
|
|
|
24.CANCEL/CONFIRM button |
|
|
|
|
|
2. Signal sending display |
Function: Setting and cancel to the |
|||
3. SWING |
display |
|
timer and other additional functions. |
|
4. FAN SPEED display |
25. RESET button |
|||
|
|
|
Display |
When the remote controller appears |
|
|
|
circulated |
abnormal, use a sharp pointed |
LO MED |
|
HI |
AUTO |
article to press this button to reset |
5. LOCK display |
|
the remote. |
Healthy function is not available for some units.
Outdoor Unit
|
|
OUTLET |
|
|
INLET |
|
|
CONNECTING PIPING |
|
4 |
AND ELECTRICAL WIRING |
|
4 DRAIN HOSE |
|
|
|
|
Loading of the battery |
||
1 |
Remove the battery cover; |
|
2 |
Load the batteries as illustrated. |
|
|
2 R-03 batteries, resetting key |
|
3 |
(cylinder); |
|
Be sure that the loading |
4 is in line with the" + "/"-"; Note: Load the battery,then put on the cover again.
The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or changeover
type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Full display or unclear display during operation indicates the batteries have been used up. Please change batteries.
If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Operation
Base Operation
Remote controller |
1 |
|
TURBO/QUIET |
2
3
SWING
4
3
2
HEALTH
TIME TIME
ON OFF
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2.Select operation mode
COOL button:Cooling mode FAN button: Faning mode DRY button: Dehumidify mode
3.Select temp.setting
Press |
/ |
button |
|
Every time the button is pressed, temp.setting |
|
|
increase 1oC,if kept depressed, it will increase |
|
|
rapidly |
|
|
Every time the button is pressed, temp.setting |
|
|
decrease 1oC,if kept depressed, it will |
|
|
decrease |
rapidly |
Select a desired temperature.
4.Fan speed selection
Press FAN button. For each press, fan speed changes as follows:
Remote controller:
Display circulated
LOW MED |
HI |
AUTO |
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Operation |
Remote |
Note |
|
Mode |
Controller |
||
|
|||
|
|
Under the mode of auto operation, air conditioner will |
|
AUTO |
|
automatically select Cool or Heat operation according to |
|
|
room temperature. When FAN is set to AUTO the air |
||
|
|
conditioner automatically adjusts the fan speed according |
|
|
|
to room temperature. |
|
COOL |
|
according to room temperature. |
|
DRY |
|
In DRY mode , when room temperature becomes lower |
|
|
than temp.setting+2o C, unit will run intermittently at LOW |
||
|
|
speed regardless of FAN setting. |
|
|
|
In FAN operation mode , the unit will not operate in COOL or |
|
FAN |
|
HEAT mode but only in FAN mode, AUTO is not available in |
|
|
FAN mode. And temp. setting is disabled. In FAN mode, |
||
|
|
sleep operation is not available. |
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective |
||||
or lost, and with function of emergency running, air conditoner |
||||
can run automatically for a while. |
|
|||
When the emergency operation switch is pressed, the " Pi " |
||||
sound is heard once, which means the start of this operation. |
||||
When power switch is turning on for the first time and |
||||
emergency operation starts, the unit will run automatically in |
||||
the following modes: |
|
|
Pi |
|
Room |
Designated |
Timer |
Fan |
Operation |
temperature |
temperature |
mode |
speed |
mode |
Above 23oC |
26oC |
No |
AUTO |
COOL |
It is impossible to change the settings of temp. and fan speed,It is also not possible to operate in timer or dry mode.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room temperature is below 16oC, do not use it in the
normal operation. |
Pi Pi |
|
Continue to press the test operation
switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor unit will run in high speed.
Air Flow Direction Adjustment
1.Status display of air flow
Vertical flap
Pos.1 |
(Auto swing) |
Initial state
Pos.2 No initial state disaplayed on remote controller, the vertical flap will be fixed on the current position
2.Left and right air flow adjustment
For each press of button, remote controller displays as follows :
remote controller:
Pos.1 |
Pos.2 |
Pos.3 |
Pos.4 |
Pos.5 |
Pos.6 |
|
|
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur adjusted to left or at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY mode , otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote controller controller will automatically memorize the previous set swing position.
3