Haier AD182AMBEA, AD242AMBEA, AD42NAMBEA User Manual

0 (0)

DUCT TYPE AIR CONDITIONER

Operation & Instruction

Manual

AD182AMBEA

AD242AMBEA

AD242AMERA

AD28NAMBEA

AD36NAMBEA

AD42NAMBEA

No. 0010572489

G

Please read this operation manual before using the air conditioner.

Please keep this manual carefully and safely.

Table of Contents

Cautions

2

Safety Precautions

3-5

Parts and Functions

6

Malfunction

7-8

Care and Maintenance

9

For Preparation of Heating("Hot Keep")

10

Is The Unit Installed Correctly

11

Installation Manual For Indoor Unit

12-18

 

 

1

Cautions

Disposal of the old air conditioner

Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment.

It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.

Disposal of the packaging of your new air conditioner

All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.

All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.

Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very

important observations relating to the assembly, operation and maintenance of the air conditioner.

The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction.

Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.

Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.

Installation shall be done by professional people, don't install unit by yourself.

For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.

Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet.

All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner.

Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in serious eye injuries.

Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver.

Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.

2

Haier AD182AMBEA, AD242AMBEA, AD42NAMBEA User Manual

Safety Precautions

Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system.

Safety precautions described here are classified to "WARNING" and " CAUTION". Precautions which are shown in the column of " WANING" means that an improper handing could lead to a grave result like a death, serious injury, etc. However, even if precautions are shown in the column of "CAUTION", a very serious problem could occur depending on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure the safety.

Symbols which appear frequently in the text have following meanings.

Strictly prohibited.

 

Observe instructions faithfully.

 

Provide a positive grounding.

 

 

 

 

 

When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make sure to hand over this manual to the new operator.

CAUTIONS FOR INSTALLATION

The system should be applied to places as office, restaurant, residence and the like.

Application to inferior environment such as an engineering shop, could cause equipment malfunction and serious injury or death.

WARNING

The system should be installed by your dealer or a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

When you need some optional devices such as a humidifier, electric heater, etc., be sure to use the products which are recommended by us. These devices should be attached by a professional installer.

Installation by yourself is not encouraged because it could cause such problems as water leakage, electrical shock or fire accident by some improper handing.

CAUTION

Do not install nearby the place where may

Depending on the place of installation, a

Drain pipe should be arranged to provide a

have leakage of flammable gas.

circuit breaker may be necessary.

positive draining.

 

ON

 

 

OFF

 

If the gas leakes and gathers around, it may cause the

Unless the circuit breaker is installed, it could

If the pipe is arranged improperly, furniture or the

fire.

cause elecrical shocks.

likes may be damaged by leaked water.

Where strong winds may prevail, the

Install on the place where can endure

Make sure the system is grounded.

system should be fixed securely to prevent

the weight of air conditioner.

 

a collapse.

 

 

Bodily injury could result by a collapse.

Bodily injury could result by a careless installation.

Grounding cable should never be connected to a gas

 

 

pipe, city water pipe, lightning conductor rod or

 

 

grounding cable of telephone. If the grounding cable

CAUTIONS FOR OPERATION

 

is not set properly, it could cause electric shocks.

 

 

 

WARNING

 

You should refrain from exposing your body

Do not poke the air inlet or outlet with a

When any abnormal condition (scorching smell or oth-

directly to cool wind for a long time.

bar, etc.

ers) is found, stop the operation immediately and turn

 

 

off the power switch. Then consult your dealer.

It could affect your physical condition or cause some

Since the internal fan is operating with a high

If you continue the operation without removing the

health problems.

speed, it could cause an injury.

cause, it could result in a trouble, electric shock or fire.

 

CAUTION

 

The system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision deices or work of art.

Do not handle switches with a wet hand.

Combustion apparatus should not be placed allowing a direct exposure to wind of air conditioner.

It could cause deterioration of food or other problems.

It could cause electric shocks.

Incomplete combustion could occur on the apparatus.

3

Safety Precautions

CAUTION

Do not wash the air conditioner with water.

It could cause electric shocks.

Do not install the system where the air outlet reaches directly the flora and fauna.

It will not be good for their health.

Make sure to use a fuse of proper electric rating.

Use of steel or copper wire in place of a fuse is strictly prohibited because it could result in a trouble or fire accident.

Neither stand on the air conditioner nor place something on it.

It is strictly prohibited to place a container of combustible gas or liquid near the air conditioner or to spray it directly with the gas or liquid.

Do not operate the system while the air outlet grill is removed.

There are risks of falling or injury by collapsed object.

It could cause a fire accident.

There is a risk of injury.

Do not use the power switch to turn on or off the system.

ON

Do not touch the air outlet section while the swing louver is operating.

Do not use such equipment as a water heater, etc. around the indoor unit or the wire controller.

OFF

It could cause a fire or water leakage.

There is a risk of injury.

If the system is operated at the vicinity of such equipment which generates steam, condensed water may drip during cooling operation or it could cause a fault current or short-circuit.

When operating the system simultaneously with a combustion

Check occasionally the support structure of the unit for any damage

apparatus, indoor air must be ventilated frequently.

after a use of long period of time.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insufficient ventilation could cause an oxygen deficiency accident.

If the structure is not repaired immediately, the unit could topple down to cause

 

a personal injury.

 

 

When cleaning the system, stop the operation and turn off the

Do not put water containers on the unit such as a flower vase, etc.

power switch.

 

Cleaning should never be done while the internal fans are running with high speed.

If the structure is not repaired immediately, the unit could topple down to cause apersonal injury.

CAUTIONS FOR TRANSFER OR REPAIR

WARNING

Modification of the system is strictly prohibited. When the system needs a repair, consult your dealer.

When the air conditioner is relocated, contact your dealer or a professional installer.

Improper practice of repair could cause water leakage, electric shock or fire.

Improper practice of installation could cause water leakage, electric shock or fire.

4

Safety Precautions

The machine is adaptive in following situation

1. Applicable ambient temperature range:

 

 

 

Rated

Maximum

Minimum

 

Indoor

DB C

27

32

18

Cooling

WB C

19

23

14

 

outdoor

DB C

35

43

10

 

 

WB C

24

26

6

 

 

Heating

Indoor

DB C

20

27

15

WB C

15

--

--

 

 

outdoor

DB C

7

24

-7

 

WB C

6

18

--

 

 

2.If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.

3.If the fuse on PC board is broken please change it with the type of T 3.15A /250VAC.

4.The wiring method should be in line with the local wiring standard.

5.The power cable and connecting cable should be self-provided. The power cable should be: H07RN-F 5G 2.5mm2 (AD42NAMBEA AD36NAMBEA AD28NAMBEA(380-400V, 3N~, 50Hz)) ;

H05RN-F 3G 4.0mm2 (AD28NAMBEA AD242AMBE AD242AMERA(1PH,220-230V~, 50Hz))

H05RN-F 3G 2.5mm2 (AD182AMBEA AD142AMBE (1PH,220-230V~,50Hz). The connecting cable should be H05RN-F 4G 0.75mm2

All the cables shall have got the European authentication certificate. During installation, when the connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.

6.The power cable and connect cable should be self-provided.

7.The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less 3mm.

8.The indoor unit installation height is at least 2.5m.

9.A leakage breaker must be installed.

5