Graco Inc 240-363, 8119A, 308-8452, 240-350, 308-845 User Manual

...
0 (0)
Graco Inc 240-363, 8119A, 308-8452, 240-350, 308-845 User Manual

INSTRUCTIONS–PARTS LIST

 

308–845

This manual contains important

 

Rev. C

 

 

warnings and information.

First choice when

READ AND KEEP FOR REFERENCE.

quality counts.

t

 

 

INSTRUCTIONS

 

 

ACETAL HUSKYt 307, WALL-MOUNT PUMP, DRUM SUCTION

PROt/ Delta Sprayt Packages

Metal fluid fittings and hose couplings are stainless steel.

100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure

100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure

Packages with Fluid Pressure Regulators

Model No. 240–349

with hoses and Delta Spray air spray gun

Model No. 240–350

with hoses and Delta Spray HVLP gun

Model No. 240–351 no hoses or gun

Model No. 240–352

with hoses and PRO 3500sc electrostatic gun

Model No. 240–353

with hoses and PRO 4500sc electrostatic gun

Packages with Surge Tanks

Model No. 240–361

with hoses and Delta Spray air spray gun

Model No. 240–362

with hoses and Delta Spray HVLP gun

Model No. 240–363 no hoses or gun

8119A

This gun and hose for PRO 3500sc Electrostatic package

This gun and hose for Delta Spray Air Spray package or Delta Spray HVLP package

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441

Graco Inc. is registered to I.S. EN ISO 9001

Instruction Manual – Parts List Changes

This page contains a summary of changes or additions that do not appear in the contents of the manual.

308845 1A

Notes

308845 1B

Table of Contents

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Parts List and Parts Drawing

240–349 to 240–353 . . . . . . . . . . . . . . . . . . 10

240–361 and 240–363 . . . . . . . . . . . . . . . . 12

Fluid Filter Kit 240–440 . . . . . . . . . . . . . . . . . . . 14

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Wall Mounting Hole Layout . . . . . . . . . . . . . . . . 15

Graco Standard Warranty . . . . . . . . . . . . . . . . . 16

Graco Phone Number . . . . . . . . . . . . . . . . . . . . . 16

Symbols

Warning Symbol

WARNINGARNING

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions.

WARNING

PRESSURIZED FLUID HAZARD

Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury.

DDo not stop or deflect fluid leaks with your hand, glove, or rag.

DFollow the Pressure Relief Procedure on page 6 before cleaning, checking, or servicing the equipment.

DTighten all fluid connections before each use.

DCheck the hoses, tubes, and couplings daily. Replace parts immediately if worn, damaged, or loose. Permanently coupled hoses cannot be repaired.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury.

DGround the equipment, personnel in or close to the spray area, the object being sprayed, and all other electrically conductive objects in the spray area. See Grounding on page 5.

DIf there is any static sparking while using the equipment, stop spraying immediately. Identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable vapors from the solvent or the fluid being sprayed.

DDo not smoke in the spray area.

DExtinguish all open flames or pilot lights in the spray area.

DDo not turn on or off any light switch in the spray area.

DElectrically disconnect all equipment in the spray area.

DKeep the spray area free of debris, including solvent, rags, and gasoline.

DDo not operate a gasoline engine in the spray area.

2308-845

WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result INSTRUCTIONS in a serious injury.

DThis equipment is for professional use only.

DRead all the instruction manuals, tags, and labels before operating the equipment.

DUse the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor.

DDo not alter or modify this equipment. Use only genuine Graco parts and accessories.

DCheck the equipment daily. Repair or replace worn or damaged parts immediately.

DDo not exceed the maximum working pressure of the lowest rated system component. This package has a 100 psi (0.7 MPa, 7 bar) maximum working pressure.

DUse fluids that are compatible with the equipment wetted parts. See the Technical Data section of all the equipment manuals. Read the fluid manufacturer’s warnings.

DRoute the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 180_F (82_C) or below –40_F (–40_C).

DDo not use the hoses to pull equipment.

DDo not move pressurized equipment.

DWear hearing protection when operating this equipment.

DComply with all applicable local, state, and national fire, electrical, and other safety regulations.

TOXIC FLUID HAZARD

Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on the skin, swallowed, or inhaled.

DKnow the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.

DStore hazardous fluid in an approved container. Dispose of the hazardous fluid according to all local, state, and national guidelines.

DWear appropriate protective clothing, gloves, eyewear, and respirator.

DIf the pump diaphragm fails, hazardous fluid may be exhausted along with the air.

308-845 3

Setup

CAUTION

This equipment is compatible with most water-based materials. See the wetted parts in the Technical Data section and your fluid and solvent manufacturer’s compatibility information.

Do not use acid catalyzed materials; they are incompatible with the acetal used in this pump.

WARNING

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or

swallowed.

DRead TOXIC FLUID HAZARD on page 3.

DUse fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals.

Read the fluid and solvent manufacturer’s warnings.

General Information

DAlways use Genuine Graco Parts and Accessories, available from your Graco distributor. See the Product Data Sheet for this package, Form No. 305–898. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.

DReference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 10 and 12.

Preparing the Operator

Anybody who operates this system should be trained in the safe, efficient operation of all system components. At a minimum, all operators should thoroughly read the safety, setup, and operation sections of this manual.

Preparing the Site

DUse a compressor capable of delivering 40 cfm (1.12 m3) and a minimum of 80 psi (552 kPa, 5.4 bar) for efficient operation.

DClear obstacles and debris that could cause an unsafe operating environment.

DRun a 1/2 in. I.D. air line from your compressed air supply to the pump location. Be sure the air is dry and filtered.

DWhen the bleed-type master air valve (K) is closed and the pump air regulator is opened, it relieves all air pressure to the system components.

DVentilate the spray booth.

WARNING

To prevent hazardous concentrations of toxic and/or flammable vapors, spray only in a properly ventilated spray booth. Never operate the spray gun unless ventilation fans are operating.

Check and follow all of the national, state, and local codes regarding air exhaust velocity requirements.

4308-845

Loading...