Graco Inc 12004X User Manual
Size:
1.15 Mb
Download

Instructions-PartsList

Pistol Grip Flow Gun

309739D

For dispensing ambient temperature sealants and adhesives.

Important Safety Instructions

Read all warnings and instructions in this manual. Save these instructions.

See page 2 for part numbers and maxumum working pressure.

Model 12004X

Models 12004 and 12005

Model 12006

Models

Models

Pistol Grip, Base Seal

Part Number

Model

Description

 

 

 

2500 psi (17.2 MPa, 172 bar) maximum working pressure

 

 

 

C27020

12004

Standard base seal

 

 

 

C27031

12004X

Two stage, easy pull

 

 

 

C27067

12005

Balanced piston

 

 

 

Contents

Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Grounding and Electrical Requirements . . . . . . . . 4

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Pressure Relief Procedure . . . . . . . . . . . . . . . . . 5

Trigger Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Models 12004, 12004X . . . . . . . . . . . . . . . . . . . . 8

Model 12005 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Model 12006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Models 12004 & 12004X . . . . . . . . . . . . . . . . . . 12

Model 12005 . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Model 12006 . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 16

Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . 16

Pistol Grip, Tip Seal

Part Number

Model

Description

 

 

 

2000 psi (13.79 MPa, 137.9 bar) maximum working pressure

C27078

12006

Pistol Grip, Tip Seal

 

 

 

2

309739

Warnings

Warnings

Warning

ELECTRICSHOCKHAZARD

Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing equipment.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

Connect only to grounded power source.

SKININJECTIONHAZARD

High pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not point gun at anyone or at any part of the body.

Do not put your hand over the spray tip.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Engage trigger lock when not spraying.

Follow Pressure Relief Procedure on page5 if the nozzle clogs and before cleaning, checking or servicing equipment.

TOXICFLUIDHAZARD

Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Read MSDS’s to know the specific hazards of the fluids you are using.

Store hazardous fluid in approved containers and dispose of it according to applicable guidelines.

EQUIPMENTMISUSEHAZARD

Equipment misuse can cause death or serious injury.

Do not exceed maximum working pressure or temperature rating of lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturers warnings.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not alter or modify equipment.

For professional use only.

Use equipment only for its intended purpose. Call your Graco distributor for information.

Route hoses away from traffic areas, sharp edges, moving parts and hot surfaces.

Do not use hoses to pull equipment.

309739

3

Grounding and Electrical Requirements

Grounding and Electrical Requirements

The following are minimum requirements for a basic dispensing system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment.

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of spray gun firmly to side of a grounded metal pail. Then trigger spray gun.

1.Pump: connect a ground wire and clamp to a true earth ground as shown in pump manual.

2.Applicator: ground through motor cable assembly.

3.Fluid and air hoses: only use electrically conductive material and air hoses.

4.Dispense gun: ground through connection of hose or cable.

5.Air compressor: follow manufacturer’s recommendations.

6.Object being sprayed: refer to local code.

7.Fluid supply container: refer to local code.

8.Solvent pails used for flushing: refer to local code.

ti3795a

4

309739