GE Profile7.5 Cu. Ft. Colossal Capacity Gas Dryer

Dimensions and Installation Information (in inches)

Gas Dryer Rating

120V 60Hz, 6A

Exhaust Options: 3-way via rear, right, and bottom.

Circuit Requirements: An individual, properly grounded branch circuit, protected by a 30-amp circuit breaker or a time-delay fuse, is required.

LP Conversion Kit: WE25M46

Note: Dryer wall outlet must be located within 36” of service cord entry and accessible when dryer is mounted in position.

Installation Information: For complete information, see

 

installation instructions packed with your dryer.

32.34”

 

27”

SENSOR DRY

S

 

D

 

 

 

TIME DRY

W

U

 

 

Harmony

 

 

D

 

A

F

P

 

T

D

 

32.34

S

D

L

D

T

39-3/4”

39-3/4”

 

4-1/8”

3”

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Specification Revised 11/08

 

 

 

270197

GE DPVH880GJMG, DPVH880GJWW, DPVH880GJMV, DPVH880GJ User Manual

DPVH880GJ

GE Profile7.5 Cu. Ft. Colossal Capacity Gas Dryer

Special Installation Requirements:

Stacked Installation:

• Brackets for stacking dryer over washer are available at an additional cost.

Custom built-in white installation template:

• Order Pub. No. 14-A025.

Alcove or Closet Installation:

If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.

The dryer MUST be exhausted to the outside.

Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 0" either side, 3" front and rear

Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".

Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of open area equally distributed. If this closet contains both a washer and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

The dryer MUST be exhausted to the outdoors.

The installation must conform with the local codes, or in the absence of

local codes, with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearance other than Alcove or Closet Installations:

• Minimum clearances to combustible surfaces 0" both sides, 3" rear.

For more information on venting kits and accessories, please call 1-800-GE-CARES.

For answers to your Monogram,® GE Profileor GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Stacked Dimensions (in inches)

Harmony

79"

Storage Pedestal Dimensions (in inches)

SPSD157JMG - Champagne SPSD157JMV - Vermillion Red SPSD157JWW - White

This optional 15" pedestal raises the door opening and height of the washer or dryer. Feet on 15" pedestal allow it to adjust to 15-

3/8" height.

27

29-1/2

15

Specification Revised 11/08