GarrettCom H80P, H80B User Manual

4 (1)

Corporate Headquarters:

Garrett Communications

213 Hammond Avenue

Fremont, CA 94539

Phone: 510.438.9071

Fax: 510.438.9072

Email: support@garrettcom.com

Magnum

Personal Hubs

Models H80B and H80P

Installation and User Guide

Magnum H80B and H80P Personal Hubs User Guide (07/95)

Magnum

Personal Hub

Models H80B and H80P

Installation and User Guide

Part #: 84-00037 (07/95)

Trademarks

UL is a registered trademark of Underwriters Laboratories Ethernet is a trademark of Xerox Corporation

Velcro is a trademark of Velcro U.S.A.

Personal Hub and Magnum are trademarks of Garrett Communications, Inc.

Important: Magnum Personal Hubs contain no user serviceable parts. Attempted service by unauthorized personnel shall render any and all warranties null and void. If problems are experienced with a Magnum Personal Hub, consult Section 5, Troubleshooting, of this User Guide.

Contacting Garrett Communications

Please use the mailing address, phone and fax numbers and email address listed below:

Garrett Communications

213 Hammond Avenue

Fremont, CA 94539

Phone: 510.438.9071

Fax: 510.438.9072 Email: support@garrettcom.com

1995 Garrett Communications, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Garrett Communications, Inc.

Printed in the United States of America.

ii

Magnum H80B and H80P Personal Hubs User Guide (07/95)

TABLE OF CONTENTS

Page

1.0 SPECIFICATIONS ...........................................................

1

1.1. Technical Specifications ....................................................

1

1.2

Ordering Information ..........................................................

3

2.0 INTRODUCTION.............................................................

4

2.1

Inspecting the Package and Product....................................

4

2.2

Product Description ............................................................

5

 

2.2.1 Magnum H80B Product Description .......................

6

 

2.2.2 Magnum H80P Product Description .......................

8

2.3

Features and Benefits ........................................................

10

2.4

Applications ......................................................................

11

3.0 INSTALLATION..................................................................

14

3.1

Magnum H80B Installation...............................................

14

3.2

Magnum H80P Installation ...............................................

15

3.3

Table-Top or Shelf Mounting ..........................................

15

3.4

Wall (or Vertical Surface) Mounting ................................

16

3.5

Ethernet Media Connections .............................................

17

 

3.5.1 Twisted Pair Segment Connections .......................

17

 

3.5.2 AUI Connections (Model H80P only)...................

18

 

3.5.3 ThinNet 10BASE2 (BNC) Connections................

19

3.6

Switchable Up-Link Feature .............................................

20

3.7

Cascading Personal Hubs with the Up-Link Port..............

21

4.0 OPERATION ..................................................................

22

4.1

Functional Operation, Use of LED Indicators...................

22

5.0 TROUBLESHOOTING ..................................................

24

5.1

Before Calling for Assistance............................................

24

5.2

When Calling for Assistance.............................................

25

5.3

Return Material Authorization (RMA) Procedure.............

25

5.4

Shipping and Packaging Information ................................

26

APPENDIX A: WARRANTY INFORMATION ..........................

27

Federal Communications Commission

Radio Frequency Interference Statement

This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

iii

GarrettCom H80P, H80B User Manual

MAGNUM

ETHERNET CONNECTIVITY PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

Overview

Garrett Communications offers the Magnum line of Ethernet LAN physical layer connectivity products with industry-standard functionality. Magnum products are available worldwide through OEMs, integrators, representatives, and international distributors.

Stackable Hubs, SNMP Optional

24-Port 10BASE-T Hub

12-Port 10BASE-T Hubs

Local Bridge with SNMP

Local Bridge, full-featured, self-learning

The "X-line" of configurable MiXed Media products Stackable Concentrators, SNMP optional, 13 ports Mini-Concentrators, 7 ports

Workgroup Bridges, all media types

Two-Port Repeaters, internal power supply, all media types Two-Port Repeaters, external power supply, all media types Repeater Port Modules (RPMs), 6 types for all Ethernet media

Bridge Port Modules (BPMs), 4 types for segment isolation

Workgroup Hubs ( the "ten" series)

8-port + AUI or Port Module option

16-port + AUI and Port Module slot

24-port + AUI and Port Module slot

Personal Hubs

9-port and 5-port Personal Hubs, with manual up-link switch 8-port and 4-port + AUI Personal Hubs, w/ man. up-link sw. 8-port + BNC Personal Hub, w/ manual up-link switch Stackable 8-port +AUI and BNC or Fiber, w/ up-link switch

Media Converters

Two RJ-45 Models, with BNC or Fiber

 

Fan-Outs

 

4 and 8 Port Deluxe, 2 and 4 Port Standard Models

 

Transceivers

 

Coax and Mini-Transceivers, All Types

July '95

Magnum H80B and H80P Personal Hubs User Guide (07/95)

1.0SPECIFICATIONS

1.1.Technical Specifications

Performance:

Data Rate: 10 Mbps

Partitioning: Enforced after 32 consecutive collisions. Reconnect: Occurs after 512 bits error-free transmission.

Maximum Ethernet Segment Lengths:

10BASE-T (Unshielded twisted pair) -

100 m (328 ft)

10BASE-T (Shielded twisted pair) -

150 m (492 ft)

AUI Drop Cable

 

-

50 m (164 ft)

10BASE2 ThinNet (BNC)

-

185 m (607 ft)

Network Standards:

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5. (Magnum Personal Hubs are physical layer standard Ethernet products, and operate in networks independently of all software.)

Operating Environment:

Ambient Temperature:32ºF to 122ºF (0ºC to 50ºC) Storage Temperature:-20ºC to 60ºC

Ambient Relative Humidity:10% to 95% (non-condensing)

Power Supply (External) (H80B, optional for H80P):

Power Input: 95 - 125 vac at 60 Hz for "-d" Models, 200 - 250 vac at 50 Hz for "-i" Models, which have IEC power cable connector in the external power unit.

Power Consumption: 10 watts max

Connectors:

H80B: 8 front-mounted shielded RJ-45 (1 with up-link switch), 1 rear BNC with internal termination switch.

H80P: 8 front-mounted shielded RJ-45, 1 rear DTE (male AUI)

(Shielded 10BASE-T connectors accept either unshielded or shielded wiring lugs for standard twisted pair media wiring.)

The regular RJ-45 ports support the standard for hubs-to-users twisted pair wiring: pin 1= receive+, 2 = receive-, 3 = transmit+, 6 = transmit-, other pins not used. The RJ-45 port with the MDI-X switch is normally the same, but when switched it supports the standard for up-links using twisted pair wiring, i.e., the transmit and the receive pairs are exchanged: pin 1 = transmit+, 2 = transmit-, 3 = receive+, 6 = receive- , other pins not used.

1

Magnum H80B and H80P Personal Hubs User Guide (07/95)

Switches:

Up-Link: MDI-X (Media Dependent Interface - Crossover) manual slide switch, converts RJ-45 port #8 from a regular (=) user segment port to a crossover (X) up-link port for on-off connection to a backbone or another cascaded hub.

Internal Termination (H80B only): Allows BNC conneciton without use of "T" connector. Right position -- internal termination, no "T" required. Left position -- external termination via "T" connector required.

Packaging:

Enclosure: Rugged, high strength steel enclosure. Suitable for vertical or horizontal mounting

(supplied with metal mounting clips, screws, and a Velcro strip)

Recessed LEDs to avoid damage.

Dimensions:

H80B, H80P: 4.4in x 5.0in x 0.75in

(11.2cm x 12.7cm x 1.9cm )

Weight:

 

H80B and H80P:

1.0 lbs (455 gr);

Power Supply:

1.0 lbs (455 gr)

Cooling method:

 

Convection

 

Agency Approvals:

115v 60 Hz Power Supply is UL Listed, CSA certified. 230v 50 Hz Power Supply is same, also GS approved. Emissions: Meets FCC Part 15 Class A

Warranty:

 

Three years (see also Appendix A)

Made in USA

2

Magnum H80B and H80P Personal Hubs User Guide (07/95)

1.2Ordering Information

Magnum Personal Hubs

MODEL

DESCRIPTION

Magnum H80B-d

Personal Hub with eight standard

 

RJ-45 ports, one with up-link switch,

 

plus one BNC port with internal

 

termination switch, external 115 vac

 

60 Hz power supply.

Magnum H80A-i

Same as H80B-d, but with external

 

230 vac 50 Hz power supply.

Magnum H80P

AUI powered Personal Hub with

 

eight standard RJ-45 ports, one with

 

up-link switch, plus one rear DTE

 

(maleAUI) port.

Magnum Personal Hubs Spare Parts

MODEL

DESCRIPTION

H80-d-ps

External 115 vac 60 Hz power supply.

H80-i-ps

External 230 vac 50 Hz power supply.

Garrett Communications reserves the right to change specifications,

performancecharacteristics and/or model offerings without notice.

3

Magnum H80B and H80P Personal Hubs User Guide (07/95)

2.0INTRODUCTION

This section describes the Magnum H80B and H80P Personal Hubs, including appearance, features and possible applications.

2.1Inspecting the Package and Product

Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.

This package should contain:

1

Magnum H80B or H80P Personal Hub

1External Power Supply, either 115v 60 Hz or 230v 50 Hz (H80B only)

1Velcro® Tape section, approximately 3 inches in length

1

User Guide

1

Product Registration Card

Remove the Magnum Personal Hub from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. To validate the product warranty please complete and return the enclosed Product Registration Card to Garrett Communications as soon as possible.

In the event there are items missing or damaged, contact your supplier. If you need to return the unit, try to use the original shipping container. Refer to Section 5, Troubleshooting, for specific return procedures.

4

Magnum H80B and H80P Personal Hubs User Guide (07/95)

2.2Product Description

The Magnum H80B and H80P Personal Hubs are nine-port workplace hubs in a very compact package. They are simple to install and use in an office or lab environment, requiring no special rack cabinets or wiring closet apparatus. Personal Hubs are standard physical layer Ethernet products and operate independently of all software.

Personal Hubs fit easily into the workplace environment. They are versatile enough to be table-top or shelf-mounted. Alternatively, a Velcro strip is included in the package so that the unit may easily be installed on a wall surface, or on the back or side of a desk or cabinet. All of the wiring connectors are in the same plane so that wiring space is neat and minimal. The external power supply unit (optional for the H80P) conveniently plugs into an AC wall receptacle or power strip.

The H80B and H80P Personal Hubs' RJ-45 ports support connection of up eight workstations or other network devices over full length 10BASE-T cable segments. Personal Hubs operate in compliance with the IEEE 802.3 specification for repeater functionality to perform signal amplification, re-timing of data packets, and regeneration of preamble bits for each packet received.

5

Magnum H80B and H80P Personal Hubs User Guide (07/95)

Consistent with IEEE 802.3 specifications, Personal Hubs will detect collisions, extend collision fragments, and automatically partition and re-connect individual ports in order to keep problems on one segment from causing downtime elsewhere on the network.

Personal Hubs include LINK and RX LEDs, located on top of the unit above each RJ-45 port, and one LED for DC power located at the rear near the external power supply connection. For observing operational information from the LEDs, it is easy to associate the status LEDs for each of the ports with the appropriate port plug.

2.2.1Magnum H80B Product Description

Magnum H80B Personal Hubs provide a simple and inexpensive solution for networking a personal multi-system office using 10BASE-T twisted pair cabling. They are perfect for sites that have ThinNet installed and need to wire additional office space for twisted pair.

Magnum H80Bs are also well suited for small- to-medium- size office or lab environments (up to eight persons) that need an independent Ethernet network. They operate as self-sufficient units

6

Loading...