Frigidaire PL42WC51EC User Manual

Size:
776.74 Kb
Download

Models PL30WC51EC PL36WC51EC PL42WC51EC

ENGLISH.....................................

2

FRANÇAIS................................

10

READ AND SAVE THESE INSTRUCTIONS

! INTENDED FOR DOMESTIC COOKING ONLY !

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-ratedconstruction codes and standards.

4.Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

6.Ducted fans must always be vented to the outdoors.

7.Do not use this unit with any separate solid-statespeed control device.

8.To reduce the risk of fire, use only metal ductwork.

9.This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

C.Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

D.Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.SMOTHER FLAMES with a close-fittinglid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

2.NEVER PICK UP A FLAMING PAN - You may be burned.

3.DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will result.

4.Use an extinguisher ONLY if:

A.You know you have a Class ABC extinguisher and you already know how to operate it.

B.The fire is small and contained in the area where it started.

C.The fire department is being called.

D.You can fight the fire with your back to an exit.

*Based on “Kitchen Fire Safety Tips” published by NFPA.

! CAUTION

1.To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

2.Take care when using cleaning agents or detergents.

3.Avoid using food products that produce flames under the Range Hood.

4.For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

5.To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

6.Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the hood serviced.

7.For best capture of cooking impurities, the bottom of the hood should be a minimum of 24" and a maximum of 30" above the cooking surface. See “Install Mounting Bracket” section for mounting restrictions.

8.Two installers are recommended because of the large size and weight of this hood.

9.Please read specification label on product for further information and requirements.

- 2 -

OPERATION

Controls

The hood is operated using the (4) push-buttonslocated ateye-level,on the front edge of the hood.

The light switch turns the halogen lamps on and off.

The blower on-low / off switch turns the blower on to its lowest running speed. The blower must be turned on using this switch. Turn the blower off by pressing this switch a second time.

The blower medium speed switch changes the blower speed to medium. This switch works only if the blower is already running at low or high speed.

The blower high speed switch changes the blower speed to high. This switch works only if the blower is already running at low or medium speed.

The pilot lamp lights up whenever the blower is on.

LIGHT

 

BLOWER

 

MEDIUM

 

 

PILOT

SWITCH

 

SPEED

 

 

LAMP

 

 

BLOWER

 

BLOWER

 

 

ON-LOW /

 

 

 

 

HIGH

 

 

 

OFF

 

 

 

 

 

SPEED

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIG. 1

HALOGEN BULBS

This range hood requires two halogen bulbs (Type GU10, MR16 shielded, 120V, 50W).

ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY BEFORE CARRYING OUT ANY OPERATIONS ON THE APPLIANCE.

1.Loosen the ring nut by turning it counterclockwise.

2.Loosen the bulb by turning it counterclockwise; pull the bulb downwards to remove. CAUTION: BULB MAY BE HOT!

3.Replace with Type GU10, MR16 shielded, 120V, 50W halogen bulb.

BULB

RING NUT

FIG. 2

MAINTENANCE

Proper maintenance of the Range Hood will assure proper performance of the unit.

Grease Filters

The grease filters should be cleaned frequently. Use a warm detergent solution. Grease filters are dishwasher safe.

See “INSTALL FILTERS” section for removal and installation instructions.

Non-DuctedRecirculation Filters

The non-ductedrecirculation filters should be changed every 6 months.

See “INSTALL FILTERS” section for removal and installation instructions.

Hood Cleaning

Stainless steel is one of the easiest materials to keep clean. Occasional care will help preserve its fine appearance. Cleaning tips:

Hot water with soap or detergent is all that is usually needed.

Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to avoid water marks.

For discolorations or deposits that persist, use a non-scratchinghousehold cleanser or stainless steel polishing powder with a little water and a soft cloth.

For stubborn cases, use a plastic scouring pad or soft bristle brush together with cleanser and water. Rub lightly in direction of polishing lines or "grain" of the stainless finish. Avoid using too much pressure which may mar the surface.

DO NOT allow deposits to remain for long periods of time.

DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.

DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.

Painted surfaces should be cleaned with warm water and mild detergent only.

- 3 -

PREPARE THE HOOD

Unpack hood and check contents. You should receive:

1 - Hood

1 - Decorative Flue Assembly

1 - Parts Bag containing:

1 - Mounting Bracket

1 - Discharge Collar

1 - Flue Mounting Bracket

8 - Mounting Screws (4,8 x 38mm Pan Head)

4 - Mounting Screws (3,9 x 9,5mm Pan Head)

2 - Mounting Screws (3.9 x 6mm Flat Head)

8 - Drywall Anchors

1 - Installation Instructions

MOUNTING

DISCHARGE

BRACKET

COLLAR

4 MOUNTING

SCREWS (3.9 x 9.5mm Pan Head)

2 MOUNTING BRACKET

SCREWS

(3.9 x 6mm Flat Head)

 

FLUE MOUNTING

8 MOUNTING SCREWS

8 DRYWALL

DECORATIVE

BRACKET

(4.8 x 38mm Pan Head)

ANCHORS

FLUE

 

 

 

 

 

 

 

 

FIG. 3

 

 

 

 

 

- 4 -

INSTALL THE DUCTWORK

(DUCTED HOODS ONLY)

! CAUTION: To reduce the risk of fire, use only metal ductwork.

1.Decide where the ductwork will run between the hood and the outside.

2.A straight, short duct run will allow the hood to perform most efficiently.

3.Long duct runs, elbows, and transitions will reduce the performance of the hood. Use as few of them as possible. Larger ducting may be required for best performance with longer duct runs.

4.Install a roof or wall cap. Connect round metal ductwork to cap and work back towards hood location. Use duct tape to seal the joints between ductwork sections.

ROOF CAP

 

 

6”

 

ROUNDDUCT

DECORATIVE

 

WALL

FLUE

 

CAP

HOOD

 

ROUND

 

 

 

 

ELBOW

24” TO 30” ABOVE

 

6”

COOKING SURFACE (see

ADAPTER

“INSTALL MOUNTING

BRACKETS” section for

 

 

mounting restrictions

 

 

 

 

 

 

 

FIG. 4

INSTALL ELECTRICAL

(DUCTED AND NON-DUCTEDHOODS)

WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring.

1.Plan where the hood will be located above the cook top. Refer to the “INSTALL MOUNTING BRACKET” section for hood mounting height options.

2.Install a standard 2” x 4” wall outlet box and 3-blade125 volt, 15 Amp grounded receptacle.

3.Mount the 18” to 22” below the bottom of the hood.

4.Locate the receptacle within the boundary shown and off center of the ductwork (to allow for power cord plug and flue clearance).

INSTALL MOUNTING BRACKET

(DUCTED AND NON-DUCTEDHOODS)

1.Construct wood wall framing that isflush with interior surface of wall studs. Make sure:

a)the framing is centered over installation location.

b)the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown.

2.After wall surface is finished, secure mounting bracket to framing using dimensions shown.

CEILING HEIGHT

 

 

HOOD DISTANCE ABOVE 36” HIGH COOK TOP (see note a)

 

 

24”

 

25”

 

26”

 

27”

 

28”

 

29”

 

30”

 

 

 

 

 

 

 

 

 

MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8-FOOT

37-7/8”

 

38-7/8”

 

39-7/8”

 

 

 

 

 

 

 

9-FOOT

 

 

 

 

 

 

 

 

41-7/8”

 

42-7/8”

 

43-7/8”

10FOOT (see note b)

 

 

 

 

39-7/8”

40-7/8”

 

41-7/8”

 

42-7/8”

 

43-7/8”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note a - Minimum hood distance above cook top must not be less than 24”.

A maximum 30” above cook top is highly recommended for best capture of cooking impurities.

Distances over 30” are at the installers discretion; and if ceiling height and flue length permit.

Note b - a 10-foothigh celing requires use of an optional flue extension, available from your local dealer.

- 5 -

6-1/2”

3-1/4”

18” to 22”

FIG. 5

FRAMING BEHIND WOOD CROSS

SUPPORT

DRYWALL

WOOD

CROSS

SUPPORT

FIG. 6

INSTALL FLUE MOUNTING BRACKET

(DUCTED AND NON-DUCTEDHOODS)

1.Assemble the flue mounting bracket, adjusting outside width as shown. See Figure 7.

2.Carefully center the mounting bracket directly over the range hood location.

3.Secure the bracket assembly to the ceiling using (2) 4.8x38mm mounting screws and drywall anchors (Fig. 8). Make sure the bracket is pushed into the corner, tight against the wall and centered over the hood.

FLUE MOUNTING BRACKET

DRYWALLANCHORS

3.9 x 6 mm FLAT HEAD BRACKETSCREWS

7-3/4”

 

 

4.8x38mm

(196.8 mm)

 

 

 

 

MOUNTING SCREWS

 

 

 

 

 

 

 

 

 

 

FIG. 7

 

FIG. 8

PREPARE THE HOOD

Note: On stainless steel hoods, carefully remove the plastic protective film from all exterior surfaces of the hood and decorative flues, prior to final installation.

(DUCTED HOODS ONLY)

Install the discharge collar into the duct connector of the range hood. Fig. 9.

DISCHARGE

COLLAR

DUCT

CONNECTOR

FIG. 9

- 6 -

PREPARE THE HOOD

(NON - DUCTED HOODS ONLY)

Note: The following materials must be purchased separately for non-ductedrecirculation installations.

Non - Ducted Recirculation Kit, Model DFKTWC51EC.

5” diameter metal duct.

1.Discard discharge collar and damper supplied with the hood. Install the 5” to 6” adapter supplied with the Non-DuctedRecirculation Kit. Fig. 10.

2.Secure the plenum to the flue mounting bracket with (2) 3.9x6mm flat head screws (the screws are supplied with the Non-DuctedRecirculation Kit “DFKTWC51EC”). Fig. 11.

5”-6”

 

FLUE MOUNTING

 

BRACKET

ADAPTER

3.9x6mm

 

 

FLAT HEAD

 

 

SCREWS

 

PLENUM

FIG.10

 

FIG.11

INSTALL THE HOOD

(DUCTED AND NON-DUCTEDHOODS)

Note: at least two people will be required to mount the hood.

1.Raise the hood into its mounting position.

2.Align the rectangular opening on the back of the hood with the wall-mountingbracket. Gently lower the hood until it securely engages the bracket. Fig. 12.

3.Level the hood with 2 mounting screws (3.9x9.5mm) and secure with (4) mounting screws. Use drywall anchors provided if wall studs or framing are not available. Fig. 12.

4.On ducted hoods, attach 6” round metal duct between the hood’s blower collar and duct that leads to the outside location.

5.On non-ducted hoods, attach 5” round metal expandable duct between the5”-6”adapter on the hood and the connector on the plenum.

6.Tape all duct joints to make them secure and air tight.

7.Plug the power cord into the electric wall receptacle. Tuck excess cord behind the flue.

MOUNTING SCREWS

 

(4.8x38mm)

WALL FRAMING

 

MOUNTING SCREWS (3.9x9.5mm)

MOUNTING SCREWS

(4.8x38mm) MOUNTING BRACKET

RECTANGULAR

CUTOUT

FIG.12

- 7 -

INSTALL THE HOOD, cont’d

8.Carefully place the decorative flue on the hood. Fig. 13.

- On ducted installation in rooms with8-foot ceilings, the air vents are concealed. Install the flue with the air vents

down.

-On non-ducted installations in rooms with8-foot ceilings, the air vents are exposed. Install the flue with the air vents up.

-On ducted and non-ducted installations in rooms with9-foot ceilings, the vents are exposed. Install the flue with air

vents up.

ROOMS WITH 10-FOOTCEILINGS (DUCTED HOODS ONLY)

Rooms with 10-footceilings require flue extension model FXWC51EC available from your local dealer.

9.Discard the upper flue supplied with the product. Replace it with the flue extension.

10.Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 14.

12.Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 14.

UPPER FLUE

UPPER FLUE

 

VENTS EXPOSED

3.9x9.5mm

VENTS

 

 

CONCEALED

MOUNTING SCREWS

UPPER

 

 

FLUE

 

 

LOWER

LOWER

 

 

 

 

FLUE

FLUE

FIG. 13

 

FIG.14

INSTALL FILTERS

(DUCTED AND NON-DUCTEDHOODS)

1.To remove the GREASE filter, push in on the metal latch tab and tilt filter downward to remove.

2.To install the GREASE filter, align rear filter tabs with slots in the hood. Depress the metal latch tab, push filter into position and release. Make sure filter is securely engaged after installation.

NOTE: Prior to use, remove protective film from the filter frame.

(NON-DUCTEDHOODS ONLY)

1.To remove the NON-DUCTEDRECIRCULATION filters, rotate them.

2.To install the NON-DUCTEDRECIRCULATION filters, position the filter over the blower; rotate to lock filters in place (Fig. 16).

3.Install GREASE filters after Non-ductedRecirculation filters are installed.

GREASE FILTERS

FIG.15

NON-DUCTEDRECIRCULATION FILTERS

FIG.16

- 8 -

SERVICE PARTS - LISTE PIECES DE RECHANGE

MODELS PL30WC51EC - PL36WC51EC - PL42WC51EC

KEY No.

DESCRIPTION (ENGLISH )

 

N.

DESCRIPTION (FRANCAIS)

 

 

 

 

 

9

Grease Filter

 

9

Filtre à graisse

14

Motor Capacitor

 

14

Condensateur

16

Connection Box Support

 

16

Support boîte cable alimentation

16

Electrical Box Support

 

16

Support boîte installation electrique

26

Lamp Bulb

 

26

Ampoule

45

Blower

 

45

Convoyer

48

Motor

 

48

Moteur

49

Blower Wheel

 

49

Turbine

53

Rubber Washer

 

53

Pare chocs

60

Feeder Cable

 

60

Cable alimentation

67

Cable

 

67

Cable

86

Discharge Collar

 

86

Bride de raccordement

113

Logo

 

113

Plaquette logo

118

Decorative Flue Bottom

 

118

Conduit décoratif inférieur

119

Decorative Flue Top

 

119

Conduit décoratif supérieur

120

Flue Mounting Bracket

 

120

Etrier de support

145

Feeder Cable Connection Box

 

145

Boîte cable alimentation

146

Feeder Cable Connection Box Cover

 

146

Couvercle boîte cable alimentation

147

Junction Clamp

 

147

Borne

151

Electrical Box Wires Stop

 

151

Serre cable

152

Feeder Cable Clamp

 

152

Serre cable

165

Electrical Box Capacitor

 

165

Boîte installation electrique

195

Bracket

 

195

Support

223

Switch Button

 

223

Bouton

228

Controls Board

 

228

Circuite commandes

229

Warning lamp

 

229

Voyant lumineux

230

Switch board box cover

 

230

Couvercle commandes

234

Switch board box

 

234

Boîte commandes

240

Switch Actuator

 

240

Sous-bouton

250

Ring Nut

 

250

Bague

407

Blower Support Bracket

 

407

Etrier support convoyer

477

Closing

 

477

Fermeture

998

Hardware Package

 

998

Accessoires de fixation

ALA

Halogen Support Assembly

 

ALA

Ensemble support lampe halogène

 

 

 

 

 

- 18 -

SERVICE PARTS - LISTE PIECES DE RECHANGE

MODELS PL30WC51EC - PL36WC51EC - PL42WC51EC

- 19 -