Frigidaire 318201533 User Manual

Size:
676.82 Kb
Download
40-15/16”
(104 cm)
C

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.

READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing easier. The first step of your installation should be to measure your current cutout dimensions and compare them to the cutout dimensions chart below for your model. You may find little or no cabinet work is necessary.

Canada

United States

Do not remove spacers (if equipped) on the side walls and/or on the back of the builtin oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire.

NOTES:

1.Base must be capable of supporting 225 pounds (102 kg).

2.Allow at least 21" (53.3 cm) clearance in front of oven for door depth when it is open.

3.Dimension G (cutout depth) is critical to the proper installation

of the built-inoven. If the

 

oven decorative trim does not

 

butt against the cabinet verify

 

dimension G to assure it is the

B

required depth.

 

 

 

 

Hole for

 

 

I

Cable

1” (2.5 cm)

 

(right or

 

 

Min.

 

 

left side

 

 

 

depending

 

 

 

on model)

 

F

 

G

 

 

 

H

 

 

 

 

 

 

 

11½”

 

 

 

3” (7.6 cm)

 

 

Door Open

 

(29.2 cm)

 

 

 

Max.

 

 

 

Spacer

 

1¼”

 

 

 

 

(see note 2)

 

 

 

Electrical

* Suggested distance from floor

D

 

 

(3.2 cm)

 

2" (5 cm) Wide Wood

Min.

 

Junction Box

 

 

 

is 11½" (29.2 cm).

 

 

A

 

(right or left side)

 

 

Spacer if Needed

 

Minimum required distance is

 

 

 

 

 

 

Figure 1

 

 

 

 

 

4 ½" (11.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT DIMENSIONS

 

 

 

 

MODEL

 

A

B

C

 

 

 

D

27" (68.6cm) Wall Oven

27 (68.6)

42¾ (108.6)

245/8 (62.5)

 

 

24½ (62.2)

30" (76.2cm) Wall Oven

30 (76.2)

42¾ (108.6)

28¼ (71.8)

 

 

24½ (62.2)

 

CUTOUT DIMENSIONS AND CABINET WIDTH

 

 

 

 

 

 

F

 

H

 

 

 

 

MODEL

Min.

Max.

G. Min.

Min.

Max.

 

 

I

27" (68.6cm) Wall Oven

247/8 (63.2)

25¼ (64.1)

23½ (59.7)

411/8 (104.5)

41¼ (104.8)

271/8 (68.9) Min

30" (76.2cm) Wall Oven

28½ (72.4)

29 (73.7)

23½ (59.7)

411/8 (104.5)

41¼ (104.8)

301/8 (76.5) Min

All dimensions are stated in inches and (cm).

Printed in United States

P/N 318201533 (0904) Rev. A

English – pages 1-6

 

Español – páginas 7-12

1

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1.Read all instructions contained in these installation instructions before installing the combination oven.

2.Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven.

3.Observe all governing codes and ordinances.

4.Be sure to leave these instructions with the consumer.

5.Oven door may be removed to facilitate installation.

6.THIS COMBINATION OVEN IS NOT APPROVED FOR STACKABLE OR SIDE-BY-SIDEINSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for future reference. Do not discard oven removal tools found in the literature bag.

IMPORTANT SAFETY

INSTRUCTIONS

Be sure your combination oven is installed and grounded properly by a qualified installer or service technician.

This wall oven must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.70latest edition in United Sates, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, in Canada.

Stepping, leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven.

Never use your wall oven for warming or heating the room. Prolonged use of the wall oven without adequate ventilation can be dangerous.

The electrical power to the oven must be shut off while line connections are being made. Failure to do so could result in serious injury or death.

1. Carpentry

Refer to figure 1 for the dimensions applicable to your appliance, and the space necessary to receive the combination oven. The oven support surface may be solid plywood or similar material, however the surface

must be leveled from side to side and from front to rear.

2. Electrical Requirements

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse. To know the circuit breaker or fuse required

by your model, see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage.

Appliance

Protection

Appliance

Protection

Rating Watts

Circuit

Rating Watts

Circuit

240V

Recommended

208V

Recommended

 

 

 

 

Less than 4800W

20A

Less than 4100W

20A

 

 

 

 

4800W - 7200W

30A

4100W - 6200W

30A

 

 

 

 

7200W - 9600W

40A

6200W - 8300W

40A

 

 

 

 

9600W and +

50A

8300W and +

50A

 

 

 

 

Table A

Observe all governing codes and local ordinances

1.A 3-wireor4-wiresingle phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (red and black wires). Atime-delayfuse or circuit breaker is recommended. DO NOT fuse neutral (white wire). Only certain cooktop models may be installed over certainbuilt-inelectric oven models. Approved cooktops andbuilt-inovens are listed by the MFG ID number (see the insert sheet included in the literature package).

NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI/NFPA No.70-latestedition, or with Canadian CSA Standard C22.1, Canadian Electrical Code, Part 1, and local codes and ordinances.

An extension cord should not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury.If you need a longer power cord you can purchase a 10' (3 m) power cord kit #903056-9010 by calling the Service Center.

2.These appliances should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 or Figure 2 and with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.

3.A suitable strain relief must be provided to attach the flexible armored cable to the junction box.

2

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

Electrical Shock Hazard

Electrical ground is required on this appliance.

Do not connect to the electrical supply until appliance is permanently grounded.

Disconnect power to the junction box before making the electrical connection.

This appliance must be connected to a grounded, metallic, permanent wiring system, or a grounding connector should be connected to the grounding terminal or wire lead on the appliance.

Do not use a gas supply line for grounding the appliance.

Failure to do any of the above could result in a fire, personal injury or electrical shock.

In cold weather shipping and storage conditions, make sure that oven is in final location at least three (3) hours before switching on power.

Switching on power while oven is still cold may damage the oven controls.

3. Electrical connection

It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI/NFPA No. 70-latestedition, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, and local codes and ordinances.

Risk of electrical shock (Failure to heed this warning may result in electrocution or other serious injury.) This appliance is equipped with copper lead wire. If connection is made to aluminum house wiring, use only connectors that are approved for joining copper and aluminum wire in accordance with the National Electrical Code

and local code and ordinances. When installing connectors having screws which bear directly on the steel and/or aluminum flexible conduit, do no tighten screws sufficiently to damage the flexible conduit. Do not over bend or excessively distort flexible conduit to avoid separation of convolutions en exposure of internal wires.

DO NOT ground to a gas supply pipe. DO NOT connect to electrical power supply until appliance is permanently grounded. Connect the ground wire before turning on the power.

(If your appliance is equipped with a white neutral conductor.)

This appliance is manufactured with a white neutral power supply and a frame connected copper wire. The frame is grounded by connection of grounding lead to neutral lead at the termination of the conduit, if used in USA, in a new branch circuit installation (1996 NEC), mobile home, recreational vehicles, where local code do not permit grounding trough the neutral (white) wire or in Canada, disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes, connect neutral lead to branch circuit-neutralconductor in usual manner see Figure 4. If your appliance is to be connected

to a 3 wire grounded junction box (US only), where local code permit connecting the appliancegrounding conductor to the neutral (white) see Figure 3.

NOTE TO ELECTRICIAN: The armored cable leads supplied with the appliance areUL-recognizedfor connection to larger gauge household wiring. The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring. The current carrying capacity of the conductor is governed by the temperature rating of the insulation around the wire, rather than the wire gauge alone.

Where local codes permit connecting the appliancegrounding conductor to the neutral (white) wire (US Only) (see figure 3):

1.Disconnect the power supply.

2.In the junction box:

connect appliance and power supply cable wires as shown in Figure 3.

Cable from Power Supply

White Wire (Neutral)

Red

Wires

Ground Wire

(Bare or Green Wire)

Black

Wires

Junction

Box

White Wire

(Neutral)

U.L.-ListedConduit

Connector (or CSA listed)

Cable from appliance

Figure 3

3-WIREGROUNDED JUNCTION BOX

3

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

If oven is used in a new branch circuit installation (1996 NEC), mobile home, recreational vehicle,

or where local codes do not permit grounding through the neutral (white) wire, the appliance frame MUST NOT be connected to the neutral wire of the 4-wireelectrical system. (see figure 4):

1.Disconnect the power supply.

2.Separate the green (or bare copper) and white appliance cable wires.

3.In the junction box:

connect appliance and power supply cable wires as shown in Figure 4.

Cable from Power Supply

Ground Wire

Red

White Wire

Wires

 

 

Black

 

Wires

Ground Wire

 

(Bare or Green

 

Wire)

White Wire

Junction Box

U.L.-ListedConduit

Cable from appliance

Connector (or CSA

listed)

Figure 4

 

4-WIREGROUNDED JUNCTION BOX

Model and Serial Number Location

The serial plate is located along the interior side trim of the oven and visible when the door is opened.

When ordering parts for or making inquires about your oven, always be sure to include the model and serial numbers and a lot number or letter from the serial plate on your oven.

Conv

Conv

Bake

Speed

Bake

Start

 

 

 

1

2

3

4

5

START

bake

roast

 

clean

time

time

 

 

 

Conv

Pre

Broil

Clean

Maxx

Keep

Oven

Clock

Timer

6

7

8

9

0

Clear

convert

Heat

clean

Warm

light

 

/Off

 

 

 

 

 

 

Even-CookConvection Oven

 

 

 

 

 

Controls

Serial Plate

Location

4. Cabinet Installation

IMPORTANT NOTE

Do not lift the oven by the door handle.

Heavy Weight Hazard

Use 2 or more people to move and install wall oven.

Failure to follow this instruction can result in injury or damage to the unit.

1Unpack the wall oven. Remove the bottom trim taped on the oven side panel.

2Find the 2 anti-tipmounting screws included in the literature package.

3Insert the oven into the cabinet opening. Slide oven inward leaving 1½" (3.8 cm) clearance between the oven and front of cabinet (see Figure 5).

4Pull the armored cable through the hole for it in the cabinet and toward the junction box while moving the appliance inward.

5Push the oven in and against the cabinet.

1½" (3.8 cm) clearance between unit

Figure 5

4

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

6Install the Anti-tipMounting Screws

The wall oven can tip when the door is open. Theanti-tipmounting screws supplied with the wall oven must be installed to prevent tipping of the wall oven and injury to persons.

A.The mounting holes in the side trims may be used as a template to locate the appliance mounting screw holes (see figure 6).

B.Use the two screws supplied to fix the appliance to the cabinet.

Conv

Conv

Bake

Speed

Bake

Start

 

 

 

1

2

3

4

5

START

bake

roast

 

clean

time

time

 

 

 

Conv

Pre

Broil

Clean

Maxx

Keep

Oven

Clock

Timer

6

7

8

9

0

Clear

convert

Heat

clean

Warm

light

On/Off

/Off

 

 

 

 

 

 

Even-CookConvection Oven

 

 

 

 

 

Controls

Figure 6

7Install the Bottom Trim

Place the top of the bottom trim over the side trim tabs on each side of the oven below the oven door and fix it using the 2 screws supplied in the mounting holes located on each side trim below the oven frame (see Figure 7).

Bottom Trim

Screws supplied

Figure 7

5

MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

5. Leveling the Wall Oven

1.Install an oven rack in the center of the upper oven (see Figure 8).

2.Place a level on the rack. Take 2 readings with the level placed diagonally in one direction and then the other. Use wood shims under the wall oven to level if necessary.

3.Repeat in the lower oven if you have a double cavity wall oven. If the level indicates that the rack is not level, use wood shims to reach a compromise for both ovens.

Figure 8

IMPORTANT NOTE

A cooling fan inside the upper rear part above the oven (some models) provides cooling of the oven electrical and electronic components. If the oven has been operating at high temperatures, the fan will continue to run after the oven is turned off.

7. Checking Operation

Your model is equipped with an Electronic Oven Control. Each of the functions has been factory checked before shipping. However, it is suggested that you verify the operation of the electronic oven controls once more. Refer to theUse and Care Guide for operation.

1.Remove all items from the inside of the oven.

2.Turn on the power to the oven (Refer to your Use & Care Guide.)

3.Verify the operation of the electronic oven controls: Bake - Verify that this function makes the oven hot. 20 seconds after turning oven on, open the door and you should feel heat coming from the oven.

Broil - When the oven is set to BROIL, the upper element in the oven should become red.

Before You Call for Service

Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide. It may save you time and expense. The list includes

common occurrences that are not the result of defective workmanship or materials in this appliance.

Refer to your Use and Care Guide for service phone numbers.

6

INSTRUCCIONES DE INSTALACIÓN PARA EL combinación micro ondas / horno de pared

LA INSTALACIÓN Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA.

PARA SU SEGURIDAD: No almacené ni utilice gasolina u otros vapores y líquidos inflamables en la proximidad de este o de cualquier otro artefacto.

El primer paso para su instalación debe de ser el de medir las dimensiones de la apertura y compararlas con las que se indican en el cuadro de dimensiones del hueco de la figura 1. Posiblemente encontrará que algún trabajo de carpintería será necesario.

Canada

Estados Unidos

No quite los separadores de los muros laterales o/y de la parte posterior del horno empotrado. Estos espaciadores centran el horno en el espacio provisto. El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio.

NOTAS:

 

1. La base debe poder sostener 255 libras (102kg).

I

2. Deje por lo menos 21" (53.3 cm) de espacio libre para la

1” (2.5 cm)

profundidad de la puerta cuando esta abierta.

Min.

 

3.La dimensión G (profundidad del corte) está primordial para

instalar

 

 

correctamente el horno

 

 

de pared. Si el adorno del

 

 

armazón del horno no topa

B

 

contra el armario verifique

 

 

 

si la dimensión G está en

 

 

conformidad con la dimensión

 

requerida.

 

 

 

Puerta Abierta

 

 

(vea la nota 2)

D

 

 

* Distancia sugerida desde el

 

A

 

 

suelo es 11½" (29.2 cm).

 

 

La distancia mínima requerida

 

 

es 4½" (11.4 cm).

 

 

 

 

Figura 1

C

F

H

40-15/16”

(104 cm)

11½” (29.2 cm)

Espaciador

Espaciador de Madera de 2" (5 cm) de ancho, si es necesario

Orificio para el Cable (derecha o izquierda, según el modelo)

G

3” (7.6 cm)

Max.

1¼”

(3.2 cm)

Min. Caja eléctrica de empalme (derecha o izquierda)

DIMENSIONES DEL APARATO

MODELO

 

A

B

 

C

 

 

D

27" (68.6cm)

27

(68.6)

42¾ (108.6)

 

245/8 (62.5)

24½ (62.2)

30" (76.2cm)

30

(76.2)

42¾ (108.6)

 

28¼ (71.8)

24½ (62.2)

 

 

 

 

 

 

 

 

 

DIMENSIONES DEL HUECO Y ANCHURA DEL ARMARIO

 

 

 

 

 

F

 

 

H

 

 

 

MODELO

Min.

 

Max.

G. Min.

Min.

Max.

 

I

 

 

 

 

 

 

 

 

 

 

 

27" (68.6cm) Wall Oven

247/8 (63.2)

 

25¼ (64.1)

23½ (59.7)

411/8

(104.5)

 

41¼ (104.8)

271/8

(68.9) Min

30" (76.2cm) Wall Oven

28½ (72.4)

 

29 (73.7)

23½ (59.7)

411/8

(104.5)

 

41¼ (104.8)

301/8

(76.5) Min

Todas las dimensiones se dan en pulgadas (cm).

Impreso en los Estados Unidos

 

P/N 318201533 (0904) Rev. A

 

English – pages 1-6

 

 

 

7

Español – páginas 7-12

 

 

INSTRUCCIONES DE INSTALACIÓN PARA EL combinación micro ondas / horno de pared

Notas importantes para el instalador

1.Lea todas las instrucciones contenidas en este manual antes de instalar el combinación microondas / horno de pared.

2.Saque todo el material usado en el embalaje del compartimiento del horno antes de conectar el suministro eléctrico o de gas a la estufa.

3.Observe todos los códigos y reglamentos pertinentes.

4.Deje estas instrucciones con el consumidor.

5.La puerta del horno se puede retirar para facilitar la instalación.

6.ESTE combinación microondas / horno de pared NO ESTÁ APROBADO PARA LA INSTALACIÓN APILABLE O DE LADO A LADO.

Nota importante al consumidor

Conserve estas instrucciones y el manual del usuario para referencia futura. No tirar las herramientas para retirar el horno incluidas en la bolsa de la literatura.

INSTRUCCIONES IMPORTANTES DE SEGURIDAD

Asegúrese de que su combinación microondas / horno de pared sea instalado y puesto a tierra de forma apropiada por un instalador calificado o por un técnico de servicio.

Este horno de pared debe ser eléctricamente puesto a tierra de acuerdo con los códigos locales o, en su ausencia, con el Código Eléctrico Nacional ANSI/ NFPA No. 70–últimaedición en los Estados Unidos, o el Código Eléctrico Canadiense CSA Standard C22.1, Part 1, en Canadá.

Pisar, apoyarse, o sentarse sobre la puerta de este horno de pared puede

causar serias lesiones y daños al horno de pared.

Nunca use su horno de pared para calentar una habitación. El uso prolongado de la estufa sin la ventilación adecuada puede ser peligroso.

La corriente eléctrica al horno debe estar apagada mientras se hacen las

conexiones de líneas. Si no se apaga, daños serios o la muerte podrían resultar.

1. Carpintería

Consulte la Figura 1 para conocer las dimensiones pertinentes al modelo de su horno y al espacio necesario en el que poner el horno. La superficie donde se va a apoyar el horno debe de ser de madera contrachapada sólida u otro material similar y, sobre todo, la superficie tiene que estar a nivel, de lado a lado, y de atrás hacia adelante.

2. Requerimientos Eléctricos

Se debe proveer el voltaje y la frecuencia apropiados a este electrodoméstico, y conectarse a un circuito individual correctamente puesto a tierra, protegido por un interruptor o un fusible. Para conocer el interruptor o fusible que requiere su modelo, vea la placa serial para encontrar la consumación del vatiaje y refierase al cuadro A para encontrar el amperaje del interruptor o fusible.

Grados de

Se recomienda

Grados de

Se recomienda

Vatios del

una

Vatios del

una

electrodoméstico

protección al

electrodoméstico

protección al

240V

circuito

208V

circuito

 

 

 

 

Menos de 4800W

20A

Menos de 4100W

20A

4800W - 7200W

30A

4100W - 6200W

30A

 

 

 

 

7200W - 9600W

40A

6200W - 8300W

40A

 

 

 

 

9600W and +

50A

8300W and +

50A

Table A

Observe todos los códigos que gobiernan y ordenanzas locales

1.Un cable de 3 o 4 alambres monofásico 120/240 o 120/208 voltios, 60 hertzios es la única fuente eléctrica que requiere en un circuito separado en ambos lados de la línea (alambre negro y alambre rojo) (se recomienda un fusible o un interruptor de retraso de tiempo). No funda a cable neutro (alambre blanco). Se debe de tener precaución al combinar un horno de pared y una cubierta, refiérase a la placa de seria de cada uno de los aparatos.

NOTA: Los tamaños y las conexiones del alambre deben conformarse con el tamaño del fusible y el grado de la aplicación de acuerdo con el código Eléctrico Nacional Americano ANSI/NFPA No. 70ultima edición, o con el estándar CSA canadiense C22.1 , código eléctrico canadiense, parte 1, y códigos y ordenanzas locales.

No se debera usar extensiones para enchufar este electrodoméstico. Esto podría causar un incendio, choque eléctrico u otro tipo de daño personal.Si usted necesita un cable mas largo, puede ordernar un cable de 10" kit 903056-9010 llamando al centro de Servicio.

2.Este electrodoméstico debe conectarse a la caja de fusibles (o de cortocircuito), por medio de un cable blindado flexible o un cable con forro no metálico. El cable blindado flexible que va desde el electrodoméstico debe de estar conectado directamente a la caja de empalme. La caja de empalme debe de estar localizada en el lugar que se indica en la Figura 1 o 2, dejando tanto exceso de cable como sea posible entre la caja y el electrodoméstico, de forma que así el electrodoméstico se pueda mover fácilmente, si fuera necesario para hacer una reparación.

3.Se debe de usar un conector que reduzca la tirantez de una forma adecuada para unir el cable blindado flexible a la caja de empalme.

8

INSTRUCCIONES DE INSTALACIÓN PARA EL combinación micro ondas / horno de pared

Riesgo de choque eléctrico

Una puesta a tierra se requiere en este aparato.

No lo conecte a la corriente eléctrica hasta que el aparato haya sido puesto a tierra.

Desconecte la corriente eléctrica a la caja de empalmes antes de hacer la conexión eléctrica.

Este aparato debe estar conectado con un sistema de alambres puesto en tierra, metálico y permanente o un conector de puesta a tierra

debe conectarse al terminal de puesta a tierra o el alambre conductor en al aparato.

No utilice el suministro de gas para hacer la puesta a tierra.

La falta de cualquiera de las instrucciones mencionadas podría resultar en un incendio, choque eléctrico o lesiones personales.

En cuanto a las condiciones de despacho y almacenamiento en el invierno, asegúrese de que el horno llegue a su destino final como mínimo tres

(3) horas antes de encenderlo. Si se enciende el horno cuando aún está frío, se pueden dañar los controles.

4. Conexión eléctrica

El usuario tiene la responsabilidad personal y obligación de utilizar un instalador calificado, para asegurar que la instalación eléctrica está hacha de forma adecuada y está conforme con el Código Eléctrico Nacional ANSI/NFPA No. 70-últimaedición en los Estados Unidos, o el Código Eléctrico Canadiense CSA Standard C22.1, Part 1, en Canadá.

Riesgo de choque eléctrico

(El no prestar atención a esta advertencia puede resultar en electrocución u otras lesiones graves.) Este electrodoméstico está equipado con alambre de cobre. Si se va a conectar con cableado de aluminio del hogar, utilizar únicamente conectores que están aprobados para unir cobre y aluminio de acuerdo al Código Nacional Eléctrico (NEC por sus siglas en ingles) y leyes y códigos locales. Al instalar conectores con tornillos que empujen directamente contra el acero y/o aluminio del conducto flexible, no apretar los tornillos suficientemente que dañen el conducto flexible. No doblar de más o deformar el conducto flexible para evitar separar el espiral y descubrir los alambres internos.

NO conecte el alambre puesto a tierra a una tubería de suministro de gas. NO conecte el suministro de

energía eléctrica hasta que el electrodoméstico haya sido permanentemente puesto a tierra. Conecte el alambre de puesto a tierra antes de enchufar por primera vez el electrodoméstico.

(Si su electrodoméstico está equipado con un conductor neutro blanco.)

Este electrodoméstico está fabricado con un suministro eléctrico neutro blanco y un alambre de cobre conectado al armazón. El armazón esta puesto a tierra por un enlace de la conexión a tierra con la conexión del neutro al final de la línea eléctrica, si es usado en los estados unidos una nueva instalación de circuito de bifurcación (1996 NEC), casa rodante, vehículos recreacionales, o donde los códigos locales no permitan poner a tierra mediante el neutro (blanco) o en Canadá, desconectar la conexión blanca de la verde y utilizar la conexión a tierra para poner a tierra la unidad de acuerdo a los códigos locales, conectar el neutro al circuito de bifurcaciónconductor neutro de manera usual. Ver Figura 4. Si su electrodoméstico va a ser conectado a una caja de conexión puesta a tierra de 3 cables (en los estados unidos solamente), donde los códigos locales permitan conectar el conductor de poner a tierraelectrodoméstico con el neutro (blanco) ver Figura 3.

NOTA AL ELECTRICISTA: Los conductores de cable blindados provistos con este artefacto son aprobados por UL para la conexión al alambrado de casa de un calibre mayor. El aislamiento de los conductores está calificado para temperaturas más altas que las del alambrado de

la casa. La capacidad de corriente del conductor está gobernada por la calificación de la temperatura del aislamiento alrededor del alambre en vez de solamente el calibre del alambre.

Donde los códigos locales permitan conectar el conductor de puesta a tierra del electrodoméstico al neutral (blanco) (Solamente en los Estados Unidos) (vea figura 3):

1.Desconecte el suministro eléctrico.

2.En el caja de juntas: conectar el aparato y los cables residenciales como se muestra en la figura 3.

Cable desde el suministro de energía

Alambre

Alambre

desnudo

Alambre

negros

 

rojos

 

 

Caja de

 

empalmes

 

Alambre

Alambre verde

desnudo

Conductor de

o desnudo

 

unión listado-UL

Cable de la estufa

(o CSA)

Figura 3 - CAJA DE EMPALMES

DE 3 ALAMBRES PUESTA A TIERRA

9

INSTRUCCIONES DE INSTALACIÓN PARA EL combinación micro ondas / horno de pared

Si el horno se usa en una instalación de circuito de ramal nuevo (1996 NEC), en una casa rodante, en un vehículo para recreación o si los códigos locales NO permiten la conexión a tierra a través del cable

neutral (blanco), el armazón del electrodoméstico NO TIENE QUE estar conectado al alambre neutro

del sistema eléctrico de 4 alambres. (ver figura 4):

1.Desconecte el suministro eléctrico

2.Separe el alambre verde (o cobre desnudo) y el alambre blanco del electrodoméstico.

3.En el caja de juntas: conectar el aparato y los cables residenciales como se muestra en la figura 4.

Cable desde el suministro de energía

Alambre

 

desnudo

Alambre

Alambre

blanco

 

rojos

 

 

Alambre

Alambre

negros

verde o

 

desnudo

Alambre blanco

 

Caja de

Conductor de

empalmes

unión listado-UL

Cable de la estufa

(o CSA)

Figura 4- CAJA DE EMPALMES

DE 4 ALAMBRES PUESTA A TIERRA

Ubicación del número de modelo y de serie

La placa con el número de serie está ubicada en la guarnición interior lateral del horno y se puede ver cuando se abre la puerta.

Cuando haga pedidos de repuestos o solicite información con respecto a su horno, esté siempre seguro de incluir el número de modelo y de serie y el número o letra del lote de la placa de serie de su horno.

La placa de serie está ubicada aquí.

Conv

Conv

Bake

Speed

Bake

Start

 

 

 

1

2

3

4

5

START

bake

roast

 

clean

time

time

 

 

 

Conv

Pre

Broil

Clean

Maxx

Keep

Oven

Clock

Timer

6

7

8

9

0

Clear

convert

Heat

clean

Warm

light

 

/Off

 

 

 

 

 

 

Even-CookConvection Oven

 

 

 

 

 

Controls

5. Instalación del Gabinete

IMPORTANTE

No levante el horno por la manija de la puerta.

Peligro de Peso Pesado

Use2personasomásparamovereinstalarelhorno de pared.

Si no cumple con esta instrucción, puede resultar en lesiones personales o daños al horno de pared

1Desembalar el horno de pared. Extraer la guarnición inferior y los 2 tornillos unidos con cinta al panel lateral del horno.

2Buscar los tornillos que se incluyen en el paquete de literatura.

3Insertar el horno en la abertura del gabinete. Deslizar el horno hacia dentro dejando 1½” (3,8 cm) de espacio libre entre el horno y la parte delantera del gabinete (ver la Figura 5).

4Empujar el cable blindado a través del orificio del gabinete y hacia la caja de paso mientras se desliza el accesorio hacia adentro.

5Empujar el horno hacia adentro y en contra del gabinete

1 1/2" (3.8 cm) distancia entre la unidad y el gabinete

Figura 5

10