Friedrich MR24DY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM, MR36TQY3F User Manual

0 (0)

OPERATING MANUAL

MODE D’EMPLOI

MANUAL DE FUNCIONAMIENTO

INVERTER

HEAT & COOLING MODEL (REVERSE CYCLE)

ROOM AIR CONDITIONER

MULTI SPLIT TYPE

Indoor Unit

MW09Y3FM

MW12Y3FM

MW18Y3FM

Outdoor Unit

MR24DY3F

MR36TQY3F

KEEP THIS MANUAL FOR FUTURE REFERENCE

CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO

Español Français English

P/N9373420040

Friedrich MR24DY3F, MW12Y3FM, MW09Y3FM, MW18Y3FM, MR36TQY3F User Manual

Fig. 1

 

E

1

 

 

 

 

 

 

 

 

 

 

2

 

9

 

 

 

 

=

 

 

 

 

1

Fig. 2

 

 

 

 

 

 

 

 

3

 

 

A

3

OPERATION

TIMER

SUPER QUIET COIL DRY

 

D

5

6

4 7 8

B

 

C

 

Fig. 3

 

 

 

 

9

 

 

Fig. 4

Fig. 5

J

 

 

 

T

 

 

 

 

 

 

Z

U

 

 

 

G

M

W

Y

 

 

 

N

 

]

 

H

 

 

[

X

I

O

\

 

 

 

 

F

P

 

V

K

 

 

 

 

 

S

Q

 

 

L

R

Fig. 6

To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current operation.

CONTENTS

....................................SAFETY PRECAUTIONS

En-1

ADJUSTING THE DIRECTION OF

 

FEATURES AND FUNCTIONS ...........................

En-2

AIR CIRCULATION ..............................................

En-9

NAME OF PARTS ................................................

En-3

SWING OPERATION .........................................

En-10

PREPARATION ....................................................

En-4

COIL DRY OPERATION .....................................

En-10

OPERATION ........................................................

En-5

MANUAL AUTO OPERATION ..........................

En-10

TIMER OPERATION ............................................

En-7

CLEANING AND CARE .....................................

En-11

SLEEP TIMER OPERATION ................................

En-8

TROUBLESHOOTING .......................................

En-13

 

 

OPERATING TIPS ..............................................

En-14

 

 

 

 

SAFETY PRECAUTIONS

DANGER!

CAUTION!

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.

When moving, consult authorized service personnel for disconnection and installation of the unit.

Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.

Do not insert fingers or objects into the outlet port or intake grilles.

Do not start and stop air conditioner operation by disconnecting the power supply cord and so on.

Take care not to damage the power supply cord.

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the power supply plug, and consult authorized service personnel.

If the power supply cord of this appliance is damaged, it should only be replaced by the authorized service personal, since special purpose tools and specified cord are required.

Provide occasional ventilation during use.

Do not direct air flow at fireplaces or heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of air conditioners.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Do not pull power supply cord.

Turn off power source when not using the unit for extended periods.

Check the condition of the installation stand for damage.

Do not place animals or plants in the direct path of the air flow.

Do not drink the water drained from the air conditioner.

Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works.

Connection valves become hot during Heating; handle with care.

Do not apply any heavy pressure to radiator fins.

Operate only with air filters installed.

Do not block or cover the intake grille and outlet port.

Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.

When installing the indoor and outdoor units, take precautions to prevent access by infants.

Do not use inflammable gases near the air conditioner.

En-1

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for economic and comfortable operation.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched automatically to maintain the set temperature, and the temperature is kept constant at all times.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.

WIRELESS REMOTE CONTROL UNIT

The Wireless Remote Control Unit allows convenient control of air conditioner operation.

SWING OPERATION

The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room.

REMOVABLE OPEN PANEL

The indoor unit’s Open Panel can be removed for easy cleaning and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s airflow is reduced to produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning filter uses static electricity to clean the air of fine particles and dust such as tobacco smoke and plant pollen that are too small to see.

The filter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria adsorbed by the filter.

Note that when the air cleaning filter is installed, the amount of air produced decreases, causing a slight decrease in the air conditioner's performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles, which can produce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.

En-2

NAME OF PARTS

Fig. 1 Indoor Unit

1 Operating Control Panel (Fig. 2)

2MANUAL AUTO button

When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.

The forced cooling operation is used at the time of installation.

Only for authorized service personnel's use.

When the forced cooling operation starts by any chance, press the START/STOP button to stop the operation.

3 Indicator (Fig. 3)

4 Remote Control Signal Receiver

5 OPERATION Indicator Lamp (red)

6TIMER Indicator Lamp (green)

If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 15 Auto Restart).

7 SUPER QUIET Indicator Lamp (green)

8 COIL DRY Indicator Lamp (orange)

9 Intake Grille (Fig. 4)

0 Front Panel

A Air Filter

B Air Flow Direction Louver

CRight-Left Louver

(behind Air Flow Direction Louver)

D Drain Hose

EAir Cleaning Filter

Refer to the folded out page on the cover.

Fig. 5 Remote Control Unit

F SLEEP button

G MASTER CONTROL button

H SET TEMP. button (

/ )

I COIL DRY button

 

J Signal Transmitter

 

K TIMER MODE button

L TIMER SET ( /

) button

M FAN CONTROL button

N START/STOP button

O SET button

P SWING button

Q RESET button

RTEST RUN button

This button is used when installing the conditioner, and should not be used under normal conditions, as it will cause the air conditioner’s thermostat function to operate incorrectly.

If this button is pressed during normal operation, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously.

To stop the test operation mode, press the START/STOP button to stop the air conditioner.

S CLOCK ADJUST button

T Remote Control Unit Display (Fig. 6) U Transmit Indicator

V Clock Display

W Operating Mode Display X Timer Mode Display

Y Fan Speed Display

Z Temperature SET Display [ COIL DRY Display

\ SLEEP Display

] SWING Display

En-3

Loading...
+ 13 hidden pages