Friedrich H)A09K25''G User Manual

Size:
595.68 Kb
Download

Parts Manual

A SERIES

Single Package

Vertical Air Conditioning System

G Suffix Models

MODELS

V(E,H)A09K25**G V(E,H)A09K34**G V(E,H)A09K50**G V(E,H)A12K25**G V(E,H)A12K34**G V(E,H)A12K50**G V(E,H)A18K25**G V(E,H)A18K34**G V(E,H)A18K25**G

VPPM03G(11-02)

** Digits vary with model.

Model Number Identification Guide

MODEL NUMBER

V

E

A

09

K

50

RT

G (Suffix)

 

 

 

 

 

 

 

 

 

 

SERIES

 

 

 

 

 

 

 

 

 

V = Vertical Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E = Cooling with or

 

 

 

 

 

 

 

 

ENGINEERING CODE

without electric heat

 

 

 

 

 

 

 

 

H = Heat Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESIGN SERIES

 

 

 

 

 

 

 

 

RT = Remote Thermostat

 

 

 

 

 

 

 

 

SP = Seacoast Protected

 

 

 

 

 

 

 

 

 

NOMINAL CAPACITY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEATER SIZE

09 = 9,000 Btuh 12 = 12,000 Btuh

 

 

 

 

(Nominal KW size)

18 = 18,000 Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 = no elect. heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VOLTAGE

 

 

 

 

 

 

 

 

25 = 2.5KW

 

 

 

 

 

 

 

 

34 = 3.4KW

K=208/230V-1Ph-60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 = 5.0KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial Number Identification Guide

SERIAL NUMBER

 

L

 

B

A

V

00001

 

 

 

 

 

 

 

 

PRODUCTION RUN NUMBER

DECADE MANUFACTURED

 

 

 

 

 

 

 

 

 

 

 

J = 9

K = Not Used

 

 

 

 

 

PRODUCT LINE

L = 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R = RAC

 

 

 

 

 

 

 

 

YEAR MANUFACTURED

 

 

 

 

 

P = PTAC

A = 1

E = 5

J = 9

 

 

 

 

 

E = EAC

B = 2

F = 6

K = 0

 

 

 

 

 

V = VPAK

C = 3

G = 7

 

 

 

 

 

 

H = SPLIT

D = 4

H = 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MONTH MANUFACTURED

 

 

 

 

 

 

A = Jan

D = Apr

G = Jul

K = Oct

 

 

 

 

B = Feb

E = May H = Aug

L = Nov

 

 

 

 

C = Mar

F = Jun

J = Sep

M = Dec

 

 

 

 

This document reflected an accurate listing of parts and information at the time of its publication. Our policy of continuously upgrading and improving our products makes it impossible to keep it up to date. Your Friedrich dealer, his supplier and the Customer Service Department at Friedrich will have the latest information should problems arise. Please contact us.

2

Electrical Component Layout

1- Quick Disconnect

2- Capacitor

3- Defrost Thermostat

4- Transformer

5- Cool Relay

6- Fan Relay

7- Heat 1 Relay - Electric Strip

8- Heat 2 - Reversing Valve

9- Electric Strip Heater

10Thermostat Terminal Block

3

Components

4

Key

Part #

Description

 

09

12

18

Notes

 

 

 

 

G

G

G

 

 

 

 

 

 

 

 

 

1

250-249-08

Compressor

 

1

 

 

 

1

250-249-07

Compressor

 

 

1

 

 

1

250-249-06

Compressor

 

 

 

1

 

2

617-645-35

Overload

 

1

 

 

 

2

617-645-21

Overload

 

 

1

 

 

2

617-645-22

Overload

 

 

 

1

 

3

618-501-07

Indoor Coil Assy.

1

1

 

 

3

618-500-10

Indoor Coil Assy.

 

 

1

 

4

618-503-17

Outdoor Coil Assy.

1

1

 

 

4

618-502-18

Outdoor Coil Assy.

 

 

1

 

4

618-503-18

Outdoor Coil Assy. (*See notes)

1

1

 

Sea Coast

4

618-502-19

Outdoor Coil Assy. (*See notes)

 

 

1

Sea Coast

5

037-605-11

Tube, Capillary, Cooling

1

1

 

Heat Pump

5

013-899-03

Tube, Capillary, Cooling

 

 

2

Heat Pump

5

037-605-18

Tube, Capillary, Heating

1

 

 

Heat Pump

5

037-605-20

Tube, Capillary, Heating

 

1

 

Heat Pump

5

013-902-23

Tube, Capillary, Heating

 

 

1

Heat Pump

5

013-899-03

Tube, Capillary, Cooling

 

 

2

Electric Heat

6

800-237-00

Base pan

 

1

1

1

 

7

601-799-00

Bellows, Condensate Valve

1

1

1

 

8

800-228-00

Bracket, Bellows

1

1

 

 

8

800-228-01

Bracket, Bellows

 

 

1

 

9

210-590-23

Suction Freeze Protection Device

1

1

1

 

10

210-585-68

Check Valve

 

1

 

 

 

10

210-585-67

Check Valve

 

 

1

 

 

10

650-135-00

Check Valve

 

 

 

1

 

11

605-420-03

Fan, Plastic 13”

 

1

1

 

 

11

605-420-04

Fan, Plastic 14.5”

 

 

1

 

 

 

 

 

 

 

 

12

617-769-00

Motor Mount Asy

1

1

1

 

 

 

 

 

 

 

 

13

800-067-02

Riser, Motor Mount

1

1

 

 

13

800-067-01

Riser, Motor Mount

 

 

1

 

 

 

 

 

 

 

 

14

800-068-01

Motor 1/4 1 6p CCW

1

1

1

 

 

 

 

 

 

 

 

 

15

618-049-00

Shroud Medium

 

 

 

1

 

 

 

 

 

 

 

 

 

15

618-036-01

Shroud Small.

 

1

1

 

 

 

 

 

 

 

 

 

 

16

800-170-00

Heater 2.5 KW

230V

1

1

1

 

 

 

 

 

 

 

 

 

16

800-170-01

Heater 3.4 KW

230V

1

1

1

 

 

 

 

 

 

 

 

16

800-170-02

Heater 5.0 KW 230V

1

1

1

 

17

250-111-00

Defrost Thermostat

1

1

1

 

 

 

 

 

 

 

 

 

18

210-584-07

Limit Switch

 

1

1

1

2.5 Kw Heater

 

 

 

 

 

 

 

 

18

210-584-08

Limit Switch

 

1

1

1

3.4 Kw Heater

 

 

 

 

 

 

 

 

18

210-584-09

Limit Switch

 

1

1

1

5.0 Kw Heater

 

 

 

 

 

 

 

 

19

606-106-05

Wheel Blower

 

1

 

 

 

 

 

 

 

 

 

 

 

19

606-106-10

Wheel BIower

 

 

1

1

 

 

 

 

 

 

 

 

20

610-805-38

Capacitor 25/10 MF 370V

1

1

 

 

20

610-805-68

Capacitor 25/10 MF 440V

 

 

1

 

21

600-840-33

Relay 24V SPST * See Notes

3

3

3

Heat Pump (4)

22

210-568-99

Transformer

 

1

1

1

 

 

 

 

 

 

 

 

23

800-076-00

Non-FusedDisconnect

1

1

1

 

 

 

 

 

 

 

 

 

24

250-432-01

Terminal Block

 

1

1

1

 

 

 

 

 

 

 

 

25

800-103-03

Wrapper Assy. Insulated

1

1

 

 

 

 

 

 

 

 

 

25

800-103-02

Wrapper Assy. Insulated

 

 

1

 

N/S

210-586-43

Coil, Solenoid (Rev Valve)

1

1

1

 

N/S

250-182-01

Reversing Valve

1

 

 

 

N/S

250-183-01

Reversing Valve

 

1

 

 

N/S

250-187-01

Reversing Valve

 

 

1

 

N/S = Not Shown

5

FRIEDRICH AIR CONDITIONING CO.

Post Office Box 1540 San Antonio, Texas78295-1540

(210) 357-4400FAX (210)357-4480

VERT- I-PAK® SINGLE PACKAGE VERTICAL AIR CONDITIONERS LIMITED WARRANTY

1.A) ONE YEAR WARRANTY - FRIEDRICHAIR CONDITIONING CO. (FRIEDRICH) warrants to the original end-user of this product that should it prove defective due to improper workmanship and/or material under normal use for a period of one year from the date of installation, FRIEDRICH will repair or replace, at its option, any defective part without charge for the part. Replacement parts are warranted for the remainder of the original warranty period.

B)THIS WARRANTY DOES NOT INCLUDE LABOR or other cost incurred for servicing, repairing, removing, installing, shipping, or handling of either defective or replacement parts, or complete unit. Such cost may be covered by a separate warranty provided by the installing contractor.

C)EXTENDED FOUR YEAR COMPRESSOR WARRANTY- During the second through fifth year from the date of installation, should the compressor prove defective due to improper workmanship and/or material,FRIEDRICH will furnish a replacement compressor, at no charge, which is warranted for the remainder of the original warranty period.LABOR IS

NOTINCLUDEDFORINSTALLINGREPLACEMENTCOMPRESSOR.

D)NOTICE: To obtain service and/or warranty parts replacement, you must notify an authorized FRIEDRICH Air Conditioning Co. distributor, dealer, or contractor of any defect within the applicable warranty period.

2. Any defective part to be replaced must be made available toFRIEDRICH in exchange for the replacement part. You must present proof of the original date of installation of the product in order to establish the effective date of the warranty. Otherwise, the effective date will be deemed to be the date of manufacture plus thirty days. The return of the owner registration card is not a condition of warranty coverage. However, please detach and return it so that we can contact you should a question of safety arise which could affect you.

3.TO OBTAIN WARRANTY SERVICE, please contact your authorizedFRIEDRICH distributor, dealer, or the contractor who installed the equipment. If your dealer or contractor needs assistance, the authorizedFRIEDRICH distributor is available for consultation, andFRIEDRICH supports the efforts of the distributor.

4.This limited warranty applies only to units remaining at the site of the original installation (except for mobile home installations) and only to units installed within the continental United States, Alaska, Hawaii, and Canada. This limited warranty applies only if the unit is installed and operated in accordance with FRIEDRICH instructions and in compliance with applicable local installation and building codes and good trade practices.

5.THIS WARRANTY DOES NOT COVER damages caused by: (a) accident, abuse, negligence, or misuse; (b) operating the product in a corrosive atmosphere containing chlorine, fluorine or any other damaging chemicals; (c) modification, alteration, poor service practices; (d) improper matching or application of the product or components; (e) failure to provide proper maintenance and service to the product according to manufacture's instructions; (f) installation or operating of the product in a manner contrary to the instructions of the manufacturer; (g) lightning, fluctuations in electrical power or other Acts of God. ThisLIMITED WARRANTY also excludes all cost of installation, disconnection or dismantling the product, parts used in connection with normal maintenance such as air filters or belts andowner-requiredmaintenance. Consult the instructions enclosed with the product for information regarding recommended maintenance.

6.No one is authorized to change this LIMITED WARRANTY in any respect, or to create any other obligation or liability in connection with this product.

7.YOURONLYREMEDIESAREPROVIDEDINTHISLIMITEDWARRANTY.ANYEXPRESSWARRANTYNOTPROVIDED HEREIN,ANDANYREMEDYWHICH, BUT FOR THIS PROVISION, MIGHTARISE BYIMPLICATION OR OPERATION OF LAW,ISHEREBYEXCLUDEDANDDISCLAIMED.THEIMPLIEDWARRANTIESOFMERCHANTABILITYANDOFFITNESS FORANYPARTICULAR PURPOSEARE EXPRESSLYLIMITED TOATERM OF ONEYEAR FROM THE DATE OF ORIGINAL INSTALLATION.UNDERNOCIRCUMSTANCESSHALLFRIEDRICHBELIABLETOTHEOWNERORANYOTHERPERSON FORANYINCIDENTAL,SPECIALORCONSEQUENTIALDAMAGESINCONNECTIONWITHTHISPRODUCT,WHETHER ARISINGOUTOFBREACHOFWARRANTY,BREACHOFCONTRACTOROTHERWISE.

8. Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of Incidental, special or consequential damages, so the above limitations or exclusions may not apply to you,

9. This warranty gives you specific legal rights, and you may have other rights which vary from state to state and provinces to provinces.

6

7

Use Factory Certified Parts.

FRIEDRICH AIR CONDITIONING CO.

Post Office Box 1540 · San Antonio, Texas 78295-1540

4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212(210)357-4400· FAX (210)357-4480

www.friedrich.com

8 Printed in the U.S.A.VPPM03G(11-02)DM