Friedrich EQ08L11A User Manual

Size:
225.69 Kb
Download

TwinTemp

Room Air Conditioners

PURCHASER

 

 

P.O. #

 

DATE

 

 

 

 

 

 

 

 

 

PROJECT

 

 

LOCATION

 

 

 

 

 

 

 

 

 

 

 

ENGINEER

 

 

ARCHITECT

 

 

 

 

 

 

 

 

 

 

 

SUBMITTED BY

 

 

FOR APPROVAL

 

FOR REFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

PLAN DESIGNATION

QUANTITY

 

COOLING BTU/H

VOLTAGE

FRIEDRICH MODEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPACT SIZE FOR EASIER REMOVAL and STORAGE and FULL SIZE FOR MORE PERMANENT INSTALLATION

COOLING 7,700 to 36,000 BTU/h

HEATING 4,000 to 22,000 BTU/h EERs up to 12.0

DELUXE FEATURES

 

Heat pumps are ideal for southern climates; heat pump and electric heat models provide supplemental heating in colder climates*

T WINTEMP UNITS INSTALL THRU -WALLOR IN A WINDOW WITH OPTIONAL WINDOW KIT. SEE SPECIFICATIONS.

MoneySaver® setting** saves energy by cycling HEAT/COOL the fan with the compressor

3 cooling/3 heating speeds***, plus fan-onlysetting

Heat anticipating thermostat

8-wayair flow control

Defrost control (heat pumps)

Fresh air intake and stale air exhaust vents*

Rotary controls

Washable, antimicrobial filter for protection against fungal and bacterial growth

Slide-outchassis for more permanent window or wall installation (window installation requires optional window kit)

*Feature not available on model YS09L10. **Feature not available on model EQ08L11A. ***EQ08L11A has 2 cooling and 2 heating speeds, plus fan-only.

MONEY SAVER

ANTIMICROBIAL

SLIDE-OUT

FEATURE

FILTER

CHASSIS

 

 

 

 

 

 

TWINTEMP_SUBMITTAL_08

Specifications ENERGY STAR® Models

 

 

 

Electrical Characteristics (60 Hertz)

Energy

 

 

 

 

 

Cooling

Heating

Efficiency

Moisture

Room Side

 

Net

 

 

 

 

 

 

 

 

Capacity

Capacity

Volts

Cooling

Cooling

Heating

Heating

Ratio

Removal

Air Circulation

 

Weight

Model

BTU/h

Rated

Rated

Amps

Watts

Amps

Watts

EER

Pints/Hr.

CFM

Sleeve

Lbs.

 

 

 

 

 

COMMERCIAL GRADE

 

 

 

 

 

TWINTEMP Heat Pump

 

 

 

 

 

 

 

 

 

 

 

YS09L10**

9200

7400

115

7.4

767

6.9

733

12.0

1.7

300

S

113

YS13L33

12700/12500

11000/10500

230/208

5.1/5.6

1149/1131

5.3/5.8

1185/1167

11.0/11.0

3.5

325

S

117

YM18L34

18000/18000

16800/16400

230/208

8.5/9.5

1895/1895

8.5/9.0

1867/1822

9.5/9.5

4.7

400

M

166

YL24L35

24000/24000

22000/21600

230/208

10.9/12.0

2400/2400

11.0/12.0

2444/2400

10.0/10.0

7.0

600

L

198

TWINTEMP Electric Heat

 

 

 

 

 

 

 

 

 

 

 

EQ08L11A

7700

4000

115

6.5

733

11.2

1290

10.5

1.9

175

Q

76

ES12L33

12100/11900

10700/8900

230/208

4.8/5.0

1052/1017

16.0/14.7

3500/2900

11.5/11.7

2.9

320

S

111

ES16L33

16200/15900

10700/8900

230/208

7.4/8.0

1653/1656

16.0/14.7

3500/2900

9.8/9.6

4.7

360

S

116

EM18L34

17800/17600

13000/10600

230/208

8.1/8.8

1780/1760

19.5/17.0

4200/3500

10.0/10.0

4.4

400

M

160

EM24L34

23500/23000

13000/10600

230/208

11.2/12.1

2479/2421

19.5/17.0

4200/3500

9.5/9.5

7.0

400

M

154

EL36L35A

36000/35700

17300/14300

230/208

18.0/19.6

4235/4200

24.0/22.4

5500/4650

8.5/8.5

11.0

725

L

220

** Operates on 115 volt and is not equipped with supplemental heat. Will not provide heat at temperatures below 40°F. Friedrich room air conditioners are designed to operate in outdoor temperatures from 50° F to 115° F.

TwinTemp Heat Pump heating information (shown in red) indicates heat pump heating performance. TwinTemp Electric Heat heating information(shown in red) indicates electric heat strip performance. For TwinTemp Heat Pump electric heating performance refer to corresponding TwinTemp Electric Heat model.

Due to continuing research in new energy-savingtechnology, specifications are subject to change without notice.

Installation Information / Sleeve Dimensions

 

 

 

 

Depth

Minimum

Minimum

 

 

Thru-the-wall

 

 

 

 

Window Width

Finished Hole

 

 

 

Depth

Hood to

Extension

Extension

 

 

 

 

 

 

 

Sleeve

Height

Width

with Front

Louvers

Into Room

Outside

Minimum

Maximum

Height

Width

Q

14"

19 ¾"

21 38"

8 ½"

5 ½"

10 ¾"

26"

42"

14 ¼"

20"

S

15 1516"

25 1516"

27 38"

8 ¾"

3 116"

16 1516"

27 78"

42"

16 316"

26 316"

M

17 1516"

25 1516"

27 38"

8 ¾"

3 116"

16 1516"

27 78"

42"

18 316"

26 316"

L

20 316"

28"

33 58"

16 ½"

3 316"

18 1516"

29 78"

42"

20 38"

28 ¼"

Circuit Rating/ Breaker

 

Circuit Rating

 

 

 

 

 

 

 

 

 

Breaker or

Plug Face

Wall Outlet

Model

T-DFuse

(NEMA#)

Appearance

EQ08L11A. YS09L10.

125V - 15A

5 - 15P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ES12L33 and ES16L33. YS13L33.

250V - 20A

6 - 20P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EM18L34, EM24L34 and EL36L35A. YM18L34 and

250V - 30A

6 - 30P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YL24L35.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window Mounting Kits

TwinTemp Model

Kit No.

EQ08L11A

WIKQ

 

 

ES12L33, ES16L33, YS09L10 and YS13L33.

WIKS

 

 

EM18L34, YM18L34 and EM24L35.

WIKM

 

 

EL36L35A and YL24L35.

WIKL

 

 

TWINTEMP® models include accessories forthru-the-wallinstallation only. Window mounting requires use of optional accessory kit as listed above.

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selectedENERGY STAR® ( ) models meet theENERGY STAR® guidelines for energy efficiency.

The consumerthrough the AHAM Room Air Conditioner Certification Programcan be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.