Friedrich CP06F10 User Manual

Size:
1.97 Mb
Download

Room Air Conditioner

Service and Parts

Manual

F

Fan

hr

 

Speed

 

 

 

 

 

Auto

 

Money

Fan Cool

Swing

 

Saver

Only

Temp

Timer

Dry

Mode

Power

0n/0ff

115Volts

CP06F10 CP08F10

CP06 - CP08 Svc Parts 2010 (05/10)

Air Conditioner Service Manual

 

TABLE OF CONTENTS

 

Safety Precautions..........................................................................................................................................

3

Dimensions .....................................................................................................................................................

6

Outside Dimensions ...................................................................................................................................

6

Product Specifications ..................................................................................................................................

7

Operation ........................................................................................................................................................

7

Remote Control Operations ......................................................................................................................

8

Disassembly ....................................................................................................................................................

9

Mechanical Parts........................................................................................................................................

9

Air Handling Parts ...................................................................................................................................

10

Electrical Parts .........................................................................................................................................

11

Refrigerating Cycle...................................................................................................................................

12

Schematic Diagram.......................................................................................................................................

15

Wiring Diagram.........................................................................................................................................

15

Electronic Control Device.........................................................................................................................

16

Troubleshooting Guide.................................................................................................................................

17

Piping System ........................................................................................................................................

17

Troubleshooting Guide .............................................................................................................................

18

Exploded View ..............................................................................................................................................

26

Replacement Parts List ................................................................................................................................

27~28

2 Room Air Conditioner

Safety Precautions

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is classified by the following indications.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to property only.

Meanings of symbols used in this manual are as shown below.

 

 

 

Be sure not to do.

 

 

 

 

 

Be sure to follow the instruction.

 

 

WARNING

 

 

 

 

Do not place the power cord near a heater.

 

 

 

Always install the expansion panel(s).

• Improper assembly or installation may cause

• It may cause fire and electric shock.

incorrect operation, including injury, fire, and

 

electric shock hazards.

 

Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc.

• It may cause explosion or fire.

Do not disassemble or modify products.

• It may cause failure and electric shock.

Service Manual 3

Safety Precautions

Plug in the power plug properly.

Do not operate or stop the unit by inserting or pulling out the power plug.

Do not damage or use an unspecified power cord.

Otherwise, it will cause electric shock or fire.

It will cause electric shock or fire.

It will cause electric shock or fire.

Do not modify power cord length.

It will cause electric shock or fire.

Ventilate before operating air conditionerwhen gas goes out.

Use the air conditioner on a single outlet circuit.(see page 7.) Do not share the outlet with other appliances.

It will cause electric shock or fire.

Do not use the socket if it is loose or damaged.

• It may cause explosion, fire,

• It may cause fire and electric

and burn.

shock.

Always plug into a grounded outlet.

No grounding may cause electric shock.

Do not operate with wet hands or in damp environment.

• It will cause electric shock.

4 Room Air Conditioner

Safety Precautions

If water enters the product, turn off the the power switch of the main body of appliance. Contact service center after taking the powerplug out from the socket.

It will cause electric shock or failure of machine.

Do not clean the air conditioner with water.

Water may enter the unit and degrade the insulation. It may cause an electric shock.

CAUTION

Never touch the metal parts of the unit

Do not block the inlet or outlet.

when removing the filter.

 

• They are sharp and may cause injury.

Ensure that the outer caseis not damaged by age orwear.

Leaving it damaged couldresult in the air conditioner falling out of the window, creating a safety hazard.

It may cause failure of appliance or performance deteriorate.

Be cautious not to touch the sharp edges

when installing.

• It may cause injury.

Sharp edges

Service Manual 5

Dimensions

Dimensions

SymbolsUsedinthisManual

This symbol alerts you to the risk of electric shock.

This symbol alerts you to hazards that could cause harm to the air conditioner.

NOTICE This symbol indicates special notes.

OutsideDimensions

525(20 11/16")

 

 

470(18 1/2")

 

 

 

 

 

 

353(13 7/8")

6 Room Air Conditioner

Specfications

Product Specifications

 

MODLES

CP08F10

 

CP06F10

ITEMS

 

 

 

 

 

 

 

 

 

 

POWER SUPPLY

 

1Ø, 115, 60Hz

 

 

 

 

 

COOLING CAPACITY

(Btu/h)

7,800

 

6,000

 

 

 

 

 

INPUT

(W)

720

 

560

 

 

 

 

 

RUNNING CURRENT

(A)

6.8

 

5.1

 

 

 

 

 

E.E.R (BTU/W.h)

 

10.8

 

10.7

 

 

 

 

 

 

 

80(DB)*

 

67(WB)**

OPERATING

INDOOR ( F)

 

 

95(DB)*

 

75(WB)**

 

OUTDOOR ( F)

 

REFRIGERANT (R410A) CHARGE

 

345g(12.2 oz)

 

315g(11.1 oz)

 

 

 

 

 

EVAPORATOR

 

Ø7.0, 3ROW 14STACKS

 

Ø7.0, 2ROW 14STACKS

 

 

 

 

 

CONDENSER

 

Ø5.0, 3ROW 16STACKS

 

Ø5.0, 2ROW 16STACKS

 

 

 

 

FAN, INDOOR

 

TURBO FAN

FAN, OUTDOOR

 

PROPELLER TYPE FAN WITH SLINGER RING

 

 

 

 

 

FAN SPEEDS, FAN/COOLING

 

 

3/3

 

 

 

 

FAN MOTOR

 

6 POLES

 

 

 

 

OPERATION CONTROL

 

REMOTE CONTROLLER

 

 

 

 

ROOM TEMP. CONTROL

 

THERMISTOR

 

 

 

 

AIR DIRECTION CONTROL

 

HORIZONTAL LOUVER (UP & DOWN), VERTICAL LOUVER (RIGHT&LEFT)

 

 

 

 

CONSTRUCTION

 

SLIDE IN-OUTCHASSIS

 

 

 

 

PROTECTOR

COMPRESSOR

OVERLOAD PROTECTOR

 

 

 

 

FAN MOTOR

INTERNAL THERMAL PROTECTOR

 

 

 

 

 

POWER CORD

 

3 WIRE WITH GROUNDING

 

 

 

 

 

ATTACHMENT PLUG (CORD-CONNECTEDTYPE)

 

 

 

 

 

 

DRAIN SYSTEM

 

DRAIN PIPE OR SPLASHED BY FAN SLINGER

 

 

 

 

OUTSIDE DIMENSION

(inch)

18 1/2 x 13 7/8 x 20 11/16

 

 

 

 

(W x H x D)

(mm)

469 x 353 x 526

* DB:Dry Bulb **WB:Wet Bulb

Operation

DESIGNED FOR COOLING ONLY

POWERFUL AND INCREDIBLE COOLING

TOP-DOWNCHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE

BUILT-INADJUSTABLE THERMOSTAT

WASHABLE ONE-TOUCHFILTER

COMPACT SIZE

Service Manual 7

4

7

6

 

0F

Fan

hr

Speed

 

 

 

 

Auto

Money

Fan Cool

 

Swing

Saver®

Only

Temp

5

 

Dry

Timer

Mode

Power

6

0n/0ff

5

3

2

1

A ir

P ower

P urifier

Temp

F an S peed

T imer

Mode

Auto

A

Swing

S wing

 

1

2

4

3

dry operation. (dehumidify operation)

6. AUTO SWING

This button can automatically control the air flow direction.

7

To receive the signal from remote controller.

8 Room Air Conditioner

Disassembly

Disassembly

— Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord.

MechanicalParts

1.FRONT GRILLE

1.Open the lnlet grille upward or downward.

2.Remove the screw which fastens the front grille.

3.Pull the front grille from the right side.

4. Remove the front grille.

5. Re-installthe component by referring to the removal procedure, above.(See Figure 1)

Figure 1

2.CABINET

1.After disassembling the FRONT GRILLE, remove the 2 screws which fasten the cabinet at both

sides.

2. Remove the 2 screws which fasten the cabinet at back.

3. Pull the base pan forward. (See Figure 2) 4. Remove the cabinet.

5. Re-installthe component by referring to the removal procedure, above.

Figure 2

3.CONTROL BOX

1.Disconnect the unit from the power source.

2. Remove the front grille.

3. Remove the cabinet.

4. Remove the screw which fastens the control box cover.

5. Remove the housing which connects motor wire in the control box.

6. Remove the 3 leads from the compressor. 7.Discharge the capacitor by placing a 20,000 ohmresistor across the capacitor terminals.

8. Remove the 2 screws which fasten the control box.(See Figure 3)

9. Pull the control box forward completely.

10. Re-installthe components by referring to the removal procedure, above. (See Figure 3)

Figure 3

Service Manual 9

Disassembly

AirHandlingParts

1.AIR GUIDE AND BLOWER

1.

Remove the front grille.

 

2.

Remove the cabinet.

 

3.

Remove the control box.

 

4.

Remove the 3 screws which fasten the brace.

 

5.

Remove the brace.

 

6.

Remove the 2 screws which fasten the evaporator.

 

7.

Move the evaporator forward and pulling it upward

 

 

slightly. (See Figure 4)

 

8.

Move the evaporator to the left carefully.

Figure 4

 

 

9.Pull out the hook of orifice by pushing the tabs and remove it. (See Figure 5)

10. Remove the clamp with a hand plier which secures the blower.

11. Remove the blower.

12. Remove the 4 screws which fasten the air guide from the barrier.

13. Move the air guide backward, pulling out from the base pan.

14. Re-installthe components by referring to the removal procedure, above.

Figure 5

2.FAN AND SHROUD

1. Remove the cabinet.

2. Remove the brace.

3. Remove the 3 screws which fasten the condenser.

4. Move the condenser to the left carefully.

5. Remove the clamp which secures the fan.

6. Remove the fan and then pull out the shroud. (See Figure 6)

7. Re-installby referring to the removal procedure.

Figure 6

10 Room Air Conditioner