Friedrich CP06-CP08 User Manual

Size:
5.15 Mb
Download

F

Fan

hr

 

Speed

 

 

 

 

 

Auto

 

Money

Fan Cool

Swing

 

Saver

Only

Temp

Timer

Dry

Mode

Power

0n/0ff

CP06

CP08

 

 

F

Fan

 

hr

Speed

 

 

 

 

Auto

 

 

Swing

Timer

Mode

Power

0n/0ff

2007

Congratulations! Thank you for choosing

Friedrich.

Your Friedrich unit is designed for maximum comfort and quietness.

Table of Contents

 

Introduction ..................................................................................

2

Safety Precautions.......................................................................

3

How to operate your Friedrich ...................................................

5

Adjusting the Air Flow Direction.................................................

6

Care and Maintenance .................................................................

7

Hardware Location.......................................................................

8

Installation Instructions..........................................................

9

Troubleshooting Tips.................................................................

17

Warranty......................................................................................

18

Introduction

Before Operating Your Unit

Make sure the wiring is adequate for your unit.

If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1.

DO NOT use an extension cord.

The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not.

Make sure that the receptacle is compatible with the wall plug provided.

This insures proper grounding. If you have a two-prongreceptacle you will need to have the circuit replaced by a certified electrician with a grounded circuit that meets all national and local codes and ordinances. You must use thethree-prongplug furnished with the air conditioner.

 

CIRCUIT RATING OR

PLUG FACE

 

MODEL

TIME DELAY

FUSE

 

 

 

 

AMP

VOLT

NEMA NO.

 

CP06 CP08

15

125

5-15P

Figure 1

 

 

 

 

115V~

230V~

Power cord may include a current

 

 

 

interrupter device. A test and reset button is

 

 

 

provided on the plug case. The device

 

 

 

should be tested on a periodic basis by first

 

 

 

pressing the TEST button and then the

 

 

 

RESET button. If the TEST button does not

 

 

 

trip or if the RESET button will not stay

 

 

 

engaged, discontinue use of the air

 

 

 

conditioner and contact a qualified service

 

 

 

technician.

 

 

E N G

N OT E !

Aluminum house wiring may pose special problems. Consult a qualified electrician.

For the Best Cooling Performance and Energy Efficiency

Keep the filter clean

Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 7.

Provide good air flow

Make sure that the airflow to and from the unit is clear. Your air conditioner puts the air out at the side of the unit, and takes in air at the left. Airflow is critical for good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.

Unit Placement

If your air conditioner can be placed in a window or a wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit's efficiency.

Insulation

Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.

2

Safety Precautions

To prevent injury and property damage, follow these instructions.

■Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications.

WARNING This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to

properties only.

 

■Meanings of symbols used in this manual are as shown below.

Never Do This

Always Do This

WARNING

Plug in the power plug properly.

Otherwise, it will cause electric shock or fire due to heat generation.

Do not modify power cord length.

It will cause electric shock or fire due to heat generation.

Do not operate or stop the unit by inserting or pulling out the power plug.

It will cause electric shock or fire due to heat generation.

Do not operate with wet hands or in damp environment.

• It will cause electric shock.

Do not damage or use an unspecified power cord.

It will cause electric shock or fire.

If the power cord is damaged, it must be replaced by the manufacturer or a Friedrich-certifiedservice agent.

Do not direct air flow directly at room occupants.

• This could lead to health problems.

ENGLISH

3

4

7

6

 

0F

Fan

hr

Speed

 

Money

Saver®

Timer 0n/0ff

Auto

Fan Cool Swing

Only

Dry Temp

Mode Power

5

6

5

3

2

1

 

Power

 

Temp

Fan S peed

Timer

Mode

Auto

A

Swing

S wing

 

1

2

4

3

dry operation. (dehumidify operation)

6. AUTO SWING

This button can automatically control the air flow direction.

7

To receive the signal from remote controller.

Adjusting the Air Flow Direction

Vent Control

For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air.

CLOSE VENTOPEN

NOTE : Before using the ventilation feature, position the lever, as shown. First, pull down

part A to horizontal line with part. B

Part B

Part A

HSILGNE

Adjusting the Air Flow Direction

Airflow can be adjusted by changing the direction of the air conditioner's louvers.

Adjusting Horizontal Air Flow Direction

Adjusting the vertical louvers left and right will change horizontal airflow.

Adjusting Vertical Air Flow Direction

Adjusting the horizontal louver up and down will change vertical airflow. The louver can be adjusted by pressing in at the top or button of the horizontal louver.

Adjusting horizontal air flow

Adjusting vertical air flow

6

Care and Maintenance

Turn the power off and unplug the power plug before cleaning the air conditioner.

Air Filter

The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.

How to remove the air filter

1.Open the inlet grille upward by pulling out the bottom of the inlet grille.(a)

2.Remove the air filter from the front grille assembly by pulling the air filter up slightly.

3.Wash the filter using lukewarm water below 104°F(40°C).(b)

4.Gently shake the excess water from the filter. When completely dry, replace the filter.

b

Drainage

The base pan may overflow due to high humidity. To drain the excess water, remove the drain cap from the back of

the unit and secure the drainpipe. However, excess water may drip out of the back of the basepan, which is normal operation.

When pressing the drainpipe into place, apply force in the direction away from the fins to avoid injuring yourself.

Drain pipe

Drain cap

7

Hardware Location

Product Features

CAUTION

This appliance should be installed in accordance with local and national wiring regulations. This manual acts as a guide to help to explain product features.

Cabinet

Front Grill

Vertical Air Deflector

(Horizontal Louver)

Horizontal Air Deflector

(Vertical Louver)

Air Discharge

 

 

w Po

p me

T

 

naF

 

 

T

 

re

 

peS

 

im

 

 

 

de

 

 

re

 

 

 

 

 

 

 

 

Mo

 

 

 

 

 

 

 

 

de

 

Air Intake(Inlet Grille)

 

 

 

 

 

 

 

Air Filter

Remote Controller

 

HSILGNE

Brace

Condenser

SpFeaend

 

F

 

 

 

 

 

hr

 

 

 

 

Money

OFanlny Cool

 

 

 

Tim

Saver

 

Auto

Base Pan

0n/0ffer

 

 

 

 

 

Dry

Temp

Swing

 

 

Mode

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

Power Cord

 

 

 

 

 

Control Board

 

 

 

 

 

Evaporator

8

Installation Instructions

Read these instructions completely and carefully.

Tools You Will Need

Phillips-headscrewdriver

Scissors or knife

Flat-bladescrewdriver

Pencil

Ruler or tape measure

Level

 

Hammer

Before You Begin

ENGLISH

NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is complete.

NOTE TO CONSUMER: Keep this Installation and Operation Manual for future use.

Important notes:

It is recommended that proper attire be worn during installation.

For personal safety, this air conditioner must be properly grounded.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

CAUTION:

Do not under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems ; consult a qualified electrician.

9