DIRECT-VENTFireplace

OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

C US

NATURAL GAS “TUDOR” MODELS (V)T32N-ASERIES,

CGDV32NR and CTDV32NR-HA

PROPANE/LP GAS “TUDOR” MODELS (V)T32P-ASERIES

and CGDV32PR

WARNING: If the information in this manual is not followedexactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other ­flammable vapors and liquids in the ­vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Donottouchanyelectricalswitch;donotuseany phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installationandservicemustbeperformedbyaqualified installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Table of Contents

Safety...................................................................

2

Cleaning and Maintenance.

............................... 30

Product Identification............................................

4

Troubleshooting.................................................

32

Local Codes.........................................................

4

Replacement Parts.............................................

36

Product Features..................................................

4

Service Hints......................................................

36

Pre-InstallationPreparation..................................

5

Technical Service...............................................

36

Location of Termination Cap................................

7

Specifications.....................................................

36

Venting Installation...............................................

8

Accessories........................................................

37

Fireplace Installation..........................................

17

Parts...................................................................

38

Operation...........................................................

26

Warranty...............................................

Back Cover

Inspecting Burners.............................................

29

 

 

Safety

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate or service this fireplace.

Improper use of this fireplace cancauseseriousinjuryordeath from burns, fire, explosions, electrical shock and carbon monoxide poisoning.

DANGER:Carbonmonoxide poisoning may lead to death!

This fireplace must be installed by a qualified (certified or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, connected and sealed, carbon monoxide leakage (spillage) can occur.

2

www.fmiproducts.com

116646-01J

Safety

Continued

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once!Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING:Donotuseablower insert, heat exchanger insert orotheraccessorynotapproved for use with this fireplace.

Do not use any solid fuels (wood, coal,paper,cardboard,etc.)inthis fireplace.Useonlythegastypeindicated on fireplace name plate.

Carefully supervise young children when they are in the room with fireplace.

This fireplace reaches high temperatures. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Do not operate fireplace with glass door removed, cracked or broken.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

Do not place clothing or other flammable material on or near fireplace. Never place any objects on fireplace.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.

2.For propane/LP fireplace, do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LPfuel tank of less than 100 lbs. capacity.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.Never install the fireplace

in a recreational vehicle

in windy or drafty areas where curtains or other combustible (flammable) objects can make contact with the fireplace front

in high traffic areas

5.Do not modify this fireplace under any circumstances. Any parts removed for servicing must be replaced prior to operating fireplace.

6.Turn fireplace off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair this fireplace. Have fireplace inspected annually by a qualified service person.

7.You must keep control compartments, burners and circulating air passages clean. Morefrequentcleaningmaybeneededdue to excessive lint and dust from carpeting, beddingmaterial,etc.Turnoffthegasvalve and pilot light before cleaning fireplace.

116646-01J

www.fmiproducts.com

3

SAFETY Continued

8.Haveventingsysteminspectedannuallyby a qualified service person. If needed, have venting system cleaned or repaired. See

Cleaning and Maintenance, page 30.

9.Do not use this fireplace to cook food or burn paper or other objects.

10.This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local

codes, with the National Electrical Code, ANSI/NFPA 70.

11.Do not use fireplace if any part has been under water. Immediately call a qualified service person to arrange for replacement of the unit.

12.Do not operate fireplace if log is broken.

13.Provide adequate clearances around air openings.

Product Identification

Upper Louver Panel

 

Flue Collar

 

 

Nailing Flange

 

 

Glass Door Assembly

 

 

Piezo Ignitor

 

Log Set

 

 

Control Valve

 

 

Lower Louver Panel

 

Lava Rock

 

 

 

Glowing

 

 

Embers

Grate Assembly

 

 

ON/OFF/REMOTE Switch Blower Switch (Optional Installation)

(Optional Installation)

Figure 1 - Direct-VentFireplace with Millivolt Ignition

Local Codes

Install and use fireplace with care. Follow all

American National Standards Institute, Inc.

local codes. In the absence to local codes,

1430 Broadway

use the current National Fuel Gas Code ANSI

New York, NY 10018

Z223.1/NFPA 54*.

National Fire Protection Association, Inc.

*Available from:

Batterymarch Park

 

Quincy, MA 02269

Product Features

These are a few facts that can help you understand and enjoy your direct-ventfireplace:

The venting system may be routed to the outsideofyourhomeinseveralways.Itmay vent through the roof (vertical) or it may vent to an outside/exterior wall (horizontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.

This fireplace may be installed in any room of your house provided all local codes and these installation instructions are followed.

This fireplace does not require electricity to operate.

Only the blower requires electricity if installed. If you plan to install the blower at a later date, outlet must be wired at the bottom of the fireplace when framing.

Apiezo ignitor and ceramic electrode create sparks to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.

Each time you turn on your fireplace, you may notice some amount of condensation on the inside of the fireplace glass. This is normal and will disappear after 10-20minutes of operation.

Your direct-ventgas fireplace system (fireplace and venting) is a balanced and

4

www.fmiproducts.com

116646-01J

Product Features Continued

sealed gas operating unit. It requires approximately 10-20minutes of operating time before the flame pattern stabilizes.

Fireplaces with the suffix of -HAhavebeen designed to operate at altitudes of 4000 feet and above.

 

Pre-InstallationPreparation

Location and space requirements

of the termination cap.

 

 

 

 

Determine the safest and most efficient location

• Do not locate termination cap where exces-

for your FMI PRODUCTS, LLC direct-ventfire-

sive snoworice build up mayoccur.Besure

place. Make sure that rafters and wall studs are

toclearventterminationareaaftersnowfalls

not in the way of the venting system. Choose a

to prevent accidental blockage of venting

location where the heat output is not affected by

system. When using snow blowers, do not

drafts, air conditioning ducts, windows or doors.

direct snow towards vent termination area.

Figure 2 shows some common locations. Be

• For horizontal installations above 2,000

aware of all restrictions and precautions before

feet, it is recommended that a 12" extension

deciding the exact location for your fireplace and

pipe be added before starter elbow and a

termination cap.

round horizontal termination be used (see

When deciding the location of your fireplace,

High Altitude Installation, page 16).

 

 

 

 

 

 

 

follow these rules:

 

 

 

 

 

 

 

• Do not connect this fireplace venting to a

 

 

 

 

 

 

 

 

chimney flue serving a separate solid-fuel

 

 

 

 

 

 

 

 

burning fireplace or appliance.

 

Flush with a wall

 

 

 

• Due to high temperatures, do not locate this

 

 

 

 

 

 

 

 

 

 

 

 

fireplace in high traffic areas, windy or drafty

 

 

 

 

 

 

 

 

areas or near furniture or draperies.

Through exterior wall

 

 

 

 

• Proper clearances must be maintained.

 

 

 

 

enclosed in a chase

 

 

 

 

 

• If your fireplace is to be installed directly on

 

 

 

 

 

 

 

 

carpeting,vinyltileoranycombustiblemate-

 

 

 

 

 

 

Corner

 

rialotherthanwood,itmustbeinstalledona

 

 

 

 

 

 

 

 

 

 

 

 

 

installation

 

metal or wood panel extending the full width

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and depth of the fireplace. See Figure 3.

Figure 2 - Common Fireplace Locations

Your fireplace is designed to be used in

 

zero clearance installations. Wall or framing

 

22

1

/

"

 

 

 

 

 

 

material can be placed directly against any

 

 

2

 

 

 

 

 

RW

 

 

 

exterior surface on the back, sides or top of

16 5/8"

 

 

 

 

 

 

 

yourfireplace,exceptwherestandoffspacers

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

are integrally attached. If standoff spacers

 

 

 

 

 

 

 

 

areattachedtoyourfireplace,thesespacers

 

 

 

 

 

 

 

 

canbeplaceddirectlyagainstwallorframing

 

 

 

3

 

8

 

 

 

 

FW

 

"

 

material. See framing details on page 6.

 

34

 

/

 

 

 

 

 

 

 

 

• If you plan on installing a television or enter-

Figure 3 - Fireplace Bottom Dimensions

 

tainment center recessed above your fire-

Clearances

 

 

 

 

 

 

place,itisrecommendedthatyoumaintaina

 

 

 

 

 

 

minimum 18" above top of louver opening.

Minimum clearances to combustibles for the

• When locating termination cap, it is impor-

fireplace are as follows:

 

 

 

 

 

 

tant to observe the minimum clearances

*Back and sides

 

 

 

 

0"

 

shown in Figure 7, page 7.

Perpendicular walls

 

 

 

 

6"

 

Floor

 

 

 

 

 

0"

• If recessing into a wall, you can avoid extra

 

 

 

 

 

 

framingbypositioningyourfireplaceagainst

Ceiling to louver opening

 

 

 

42"

 

an already existing framing member.

Front

 

 

 

 

 

36"

 

Top

 

 

 

 

 

0"

• Do not recess termination cap into a wall

 

 

 

 

 

 

or siding.

Vent

(See venting instructions for

 

 

specific venting clearances.)

You may paint the termination cap with

 

Combustiblematerialwithamaximumthickness

 

450º F heat-resistantpaint to coordinate

 

with the exterior finish.

of 5/8" may be flush with top front of fireplace.

 

*Forbackandsidesoffireplace,donotpackwith

There must not be any obstruction such

 

as bushes, garden sheds, fences, decks

insulationorothermaterials.0"clearancetocom-

 

or utility buildings within 24" from the front

bustible materials are for framing purpose only.

116646-01J

www.fmiproducts.com

5

Pre-InstallationPreparation

Continued

NOTICE: This fireplace is intended for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using fireplace.Thiswillhelpcirculate the heat throughout the house. In the event of a power outage, you can use this fireplace as a heat source.

framing and finishing

Figure4showstypicalframingofthisfireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met.

For available accessories for this fireplace, see Accessories on page 37. If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height.You can install noncombustible mantels at any height above the fireplace.Note: Noncombustible mantels may discolor!

13B /8"

9 /2"

39C

3

/8"

5

D 1

 

 

 

 

 

28A1/2"

E

9

7

/8"

 

34F 3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nailing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34G 5/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tabs

 

 

 

 

 

 

H1

/8"

 

 

 

 

 

 

 

 

54

 

 

 

 

Figure 5 - Framing Clearances for Corner Installation

 

1

 

 

2

 

A

3

 

4

 

 

Wall

B

 

5

 

C

6

 

D E

 

7

 

F

G

 

Top of Louver

Opening

 

 

 

 

Mantel from

 

 

Mantel

 

Top of Louver

 

Ref.

Depth

Ref.

Opening

 

1

14"

A

16"

323/8"

2

12"

B

14"

 

3

10"

C

12"

 

4

8"

D

10"

 

5

6"

E

8"

345/8"

6

4"

F

6"

17" Horiz. Vent

7

2"

G

4"

20" Vert. Vent

Figure 6 - Clearances for Combustible

Figure 4 - Framing Clearances for

Mantels

Installation Against an Exterior Wall

 

6

www.fmiproducts.com

116646-01J