6.Place log #6 (left log) onto two pins on left side of back and front log. See Figure 49.

7.Place lava rock along sides and front of firebox bottom in areas that are visible only. It is not necessary to use all of the lava rock provided.

8.Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto exposed section of front burner and along space between burner and grate prongs (see Figure 50). This will create the glowing ember appearance as the flame touches the ember material. Do not block air slots by using too much ember material

4

in one area. Do not block pilot ports with embers. It is not necessary to use all of the ember material provided.

9.Close glass door, lock door latches, replace screen and close louvers (see steps 5 and 7 of Removing Glass Door, page 24).6

5

Figure 49 - Installing Logs No. 5 and No. 6

 

Ember Material

Figure 48 - Installing Log No. 4

Figure 50 - Placing Ember Material on

Burner

 

Operation

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand,don'ttrytorepairit,callaqualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call aqualifiedservicetechniciantoinspect the appliance and to replace any part of the control system and any gas control which has been under water.

26

www.fmiproducts.com

116646-01J

 

 

Operation

 

 

Continued

 

 

 

 

 

 

 

 

LIGHTING

 

 

 

TO TURN OFF GAS

 

 

 

 

 

 

 

INSTRUCTIONS

 

 

 

TO APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.STOP! Read the safety information on page 26.

2.Open lower louver panel.

3.Turn off all electric power to fireplace.

4.Push in gas control knob slightly and turn clockwise to OFF.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information on page 26. If you don't smell gas, go to the next step.

6.The pilot is located by the main burner and should not require accessing for lighting.

7.Turn gas control knob counterclockwise

to PILOT (see Figure 51).

8.Push in gas control knob all the way and hold. Immediately light the pilot by repeatedly pressing the piezo spark ignitor until a flame appears. Continue to hold for about 1 minute after pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 4 through 8.

Ifgascontrolknobdoesnotpopupwhen released,stopandimmediatelycallyour service technician or gas supplier.

If pilot will not stay lit after several tries, turn gas control knob to OFF and call your service technician or gas supplier.

9.Turn on all electric power to fireplace.

10.Turn gas control knob counterclockwise to ON.

11.This valve is equipped with a HI/LO feature. Set fireplace input as desired.

12.To leave pilot lit and shut off burners only,

turn control knob clockwise to the PILOT position or set selector switch in the OFF position.

13.Close lower louver panel.

Gas Control

Variable Control Knob

Knob

 

 

 

PILOT

IH

F

F

 

 

O

O

 

 

 

N

 

 

LO

Piezo Ignitor

Figure 51 - Control Valve

1.Open lower louver panel.

2.Set selector switch in the OFF position to prevent draining battery.

3.Turn off all electrical power to appliance if service is to be performed.

4.Push in gas control knob slightly and turn clockwise to OFF.

5.Close lower louver panel.

MANUAL LIGHTING

PROCEDURE

1.Remove glass door (see Removing/Replacing Glass Door, page 24).

2.Follow steps 1 through 8 under Lighting Instructions.

3.Press gas control knob and light pilot with match.

4.Keep gas control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 10 through 13 under Lighting Instructions.

5.Replace glass door (see Removing/Replacing Glass Door, page 23).

optional Hand-HeldREMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 37). Follow instructions included with the remote control.

NOTICE:Youmustlightthepilot before using the hand-heldremote control unit. SeeLighting Instructions.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON position.Adjust flame adjustment knob anywhere between HI and LO. Slide selector switch to the REMOTE position (see Figure 52, page 28). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

116646-01J

www.fmiproducts.com

27

Digital Display Shows Temperature and Settings

Operation

Continued

Blower Control Knob

(Optional Accessory) Variable

Control Knob

 

OFF ON

 

 

 

N

 

 

 

O

L

 

 

T

O

I

ON OFF REMOTE

O

O

H

L

 

 

IP FF

 

Gas Control Knob

Selector Switch in in ON Position

Remote Position

Figure 52 - Setting Selector Switch, Gas

Control Knob and Variable Control Knob

for Remote Operation

On/Off Series

(Model HRC100 and HRC101)

Hold control button on hand-heldremote until burner turns on. Hold control button again until burner turns off (see Figure 53).

To Lock press both buttons onhand-heldremote control until light stops flashing. Handheld remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed.

To Unlock press both buttons together onhand-heldremote control until the light stops flashing. Thehand-heldremote is now unlocked.

Indicator

Light

Control

Button

Figure 53 - On/Off Hand-HeldRemote

Control Unit (HRC100/HRC101)

Thermostat Series

(Model HRC200 and HRC201)

The hand-heldremote can be operated using either the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 54).To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-heldremote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-heldremote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by pressing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace.

Note: Do not leave the hand-heldremote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place thehand-heldremote in the center of the room facing towards the fireplace.

Note: Do not hold the hand-heldremote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features

When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Locks

 

 

 

 

System to

 

 

 

Turns

Prevent

 

AUTO

 

Hand-Held

Accidental

ROOM

 

SET

TEMP

 

TEMP

Remote On

Ignition

 

 

 

 

 

 

or Off and

 

 

TEMP

 

 

LOCK

POWER

Allows You

Turns

 

 

 

 

 

to Choose

Burners

 

 

 

 

 

 

the Manual

On or Off

MANU

ºC/ºF

AUTO

 

 

 

Setting

 

 

 

 

Increases or

 

 

 

Selects

Decreases

 

 

 

 

 

 

AUTO

Room

 

 

 

 

 

 

Mode

Temperature

 

 

 

 

 

 

 

in AUTO

 

 

 

 

Mode

°C/°F Mode Button

 

Figure 54 - Thermostat Hand-Held

Remote Control Unit (HRC200/HRC201)

28

www.fmiproducts.com

116646-01J

Operation

Continued

Auto Shutoff Feature

1.If the average room temperature reaches a range of 82° F (28° C) to 92° F (33° C), the hand-heldremote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand-heldremote to control the room temperature. If thehand-heldremote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace. This will occur in 8 or more minutes depending upon location of remote transmitter and strength of batteries.

Key Pad Lock Feature

This feature allows the user to lock/unlock the keypad on the hand-heldremote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating thehand-heldremote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

operating optional GWMT1 Wall Mounted Thermostat

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

Light the fireplace as instructed in Lighting Instructions on page 27. Set wall thermostat to desired temperature.

This thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation.

To turn fireplace off, adjust thermostat to the lowest setting and turn gas control knob back to PILOT. The pilot will remain lit.

IMPORTANT: To turn pilot off, turn gas control knob on heater to the OFF position.

Operating optional blower accessory

Locate blower controls by opening lower louver panel on fireplace. Blower controls are located on the right side of switch bracket to the left just inside louver panel.

The BK manual blower and BKT thermostati- cally-controlledblower have an ON setting and an OFF setting. Blower will only run when the switch is in the ON position. In the OFF position, blower will not operate.

Note for BKT Only: If you are using BKT blower with optional thermostat (wall mounted or remote control) for the fireplace, your fireplace and blower will not turn on and off at the same time. Fireplace may run for several minutes before blower turns on. After heater modulates to the pilot position, blower will continue to run. Blower will shut off after firebox temperature decreases.

The blower helps distribute heated air from the fireplace. Periodically check louvers of firebox and remove any dust, dirt or other obstructions that will hinder the flow of air.

Inspecting Burners

Check pilot flame pattern and burner flame patterns often.

PILOT Assembly

The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.

The height of the thermopile must be 3/8" to 1/2" above pilot flame as shown in Figure 55. The thermocouple must be at a height of about 1/8" above pilot flame. The flame from

pilot burner must extend beyond both the thermocouple and thermopile.

Thermopile

3/8" to 1/2"

Pilot

 

Burner

 

1/8"

Piezo

Thermocouple

Ignitor

 

Figure 55 - Pilot Assembly

116646-01J

www.fmiproducts.com

29