FMI CDCFPRB User Manual

Size:
1.69 Mb
Download

ComfortFlame TM

by FMI PRODUCTS, LLC

UNVENTED (VENT-FREE)Gas Compact Classic Hearth®

DUAL BURNER Fireplace

OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

US

Shown with Optional Cabinet Mantel/Hearth Base Accessory

Remote-ReadyModels CDCFPRB, CDCFNRB,CDCFPRB-1,

CDCFNRB-1

WARNING: If the information in this manual is not followedexactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other ­flammable vapors and liquids in the ­vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Donottouchanyelectricalswitch;donotuseany phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Table of Contents

Safety...................................................................

2

Product Identification............................................

4

Optional Remote Control Accessories.................

4

Local Codes.........................................................

5

Product Features..................................................

5

Unpacking............................................................

5

Hood Assembly...................................................

6

Air for Combustion and Ventilation.......................

6

Installation............................................................

9

Operation...........................................................

18

Inspecting Burners.............................................

20

Cleaning and Maintenance................................

20

Wiring Diagram..................................................

21

Troubleshooting.................................................

22

Parts...................................................................

26

Specifications.....................................................

30

Replacement Parts.............................................

30

Service Hints......................................................

30

Technical Service...............................................

30

Accessories........................................................

31

Warranty................................................

Back Page

Safety

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: This is an unventedgas-firedheater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer toAir for Combustion and Ventilation section on page 6 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion,electricalshockandcarbon monoxide poisoning.

2

www.fmiproducts.com

124979-01C

SAFETY

Continued

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once!Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace.

WARNING: Do not allow fans toblowdirectlyintothefireplace.

Avoidanydraftsthatalterburner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out oftrafficandawayfromfurniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen become very hot when running heater.Keepchildrenandadults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young children when they are in the room with fireplace. When using the hand-heldremote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace withthefireplacescreeninplace. Make sure fireplace screen is closed before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

124979-01C

www.fmiproducts.com

3

SAFETY Continued

5.Do not use this fireplace as a wood-burn-ing fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.Thisfireplaceisdesignedtobesmokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person.

Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 20.

9.Before using furniture polish, wax, carpet cleaner or similar products, turn fireplace off.Ifheated,thevaporsfromtheseproducts may create a white powder residue within burner box or on adjacent walls or furniture.

10.This fireplace needs fresh air ventilation to run properly.This fireplace has an Oxygen

Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation,

page 6. If fireplace keeps shutting off, see

Troubleshooting,page 21.

11.Do not run fireplace

where flammable liquids or vapors are used or stored.

under dusty conditions.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place any objects in the fireplace or on logs.

14.Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water.

15.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

17.Do not operate fireplace if log is broken. Do not operate fireplace if log is chipped (dime-sizedor larger).

18.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.

19.Provide adequate clearances around air openings.

 

Product Identification

 

Fireplace

 

Fireplace Cabinet

 

Cabinet

 

 

 

 

Hood

 

 

Hood

Screen

 

 

 

 

 

 

Logs

 

 

 

Ignitor

Log

 

 

Button

 

 

Remote Control

Ignitor Button

Control

(Optional)

 

 

 

 

Knob

 

Control Knob

 

 

 

 

Figure 1 - Vent-FreeCompact Dual Flame Fireplace

Optional Remote Control Accessories

There is are two optional remote control that

wall switch

can be purchased separately for Remote-

hand-heldON/OFF remote

Ready Models:

 

wall thermostat

 

 

hand-heldthermostat remote

 

 

See Accessories, page 31.

4

www.fmiproducts.com

124979-01C

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-firedsupplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-freegas products are prohibited for bedroom and bathroom installation in the

Commonwealth of Massachusetts.

Product Features

Safety Pilot

This fireplace has a pilot with an Oxygen

Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-freeroom fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Piezo Ignition System

This fireplace has a piezo ignitor. This system requires no matches, batteries or other sources to light fireplace.

Unpacking

1.Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hardware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, call FMI PRODUCTS, LLC at 1-866-328-4537.Please do not return it to the store.

Removing ceramic brick liners (If equipped)

WARNING: Ceramic brick liners are located behind upper louver and must be removed before lighting fireplace.

1.Remove screws from top louver and carefully remove louver (see Figure 2).

2.Remove ceramic brick liners with protective packaging. The brick liners will be installed later.

3.Remove yellow sticker from top of firebox.

4.Replace top louver using screws removed in step 1.

Wrapped

Brick Liners

Top Louver

Screws

Figure 2 - Removing Brick Liners

124979-01C

www.fmiproducts.com

5

Hood Assembly

WARNING: Always have screeninplacebeforeoperating fireplace. This prevents excessive temperatures on fireplace surfaces.

WARNING:Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this fireplace may result in property damage or personal injury.

6.Insert screws as shown in Figure 4. Tighten screws firmly.

Shoulder Screw

Screen

Tools Required:

 

 

Phillips screwdriver

slotted screwdriver

5/16" hex wrench

scissors

1.If equipped, lift fireplace screen up and pull out to remove (see Figure 3). Set screen aside until installation has been completed.

2.Cut two plastic straps to remove log from firebox cavity. Set log aside.

3.An optional blower is available. See Accessories, page 31. Install optional blower now. Follow installation instructions provided with blower.

4.Locate four black Phillips sheet metal screws in hardware packet.

5.Slide hood between louver and firebox top and align screw holes.

Figure 3 - Removing and Installing Screen

Louver

Firebox Top

 

Sheet Metal

 

Screws

 

Hood

Figure 4 - Assembling Hood

Air for Combustion and Ventilation

WARNING: This heater shall notbeinstalledinaroomorspace unless the required volume of indoorcombustionairisprovided by the method described in the

National Fuel Gas Code, ANSI Z223.1/NFPA54, the International Fuel Gas Code,or applicable local codes. Read the following instructionstoinsureproperfresh airforthisandotherfuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather

strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burningappliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers and fuelburningappliancesdrawairfromthehouse to operate. You must provide adequate fresh air for these appliances.This will insure proper venting of vented fuel-burningappliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.

6

www.fmiproducts.com

124979-01C

AIR FOR COMBUSTION AND VENTILATION

Continued

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continuous watervaporretarderwitharatingofone perm (6 x 10-11 kg perpa-sec-m2)or less with openings gasketed or sealedand

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceilingjoints, between wall panels, at penetrations for plumbing, electrical and gas lines

and at other openings.

If your home meets all of these three criteria, you must provide additional fresh air. See

Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Fireplace Location.

DETERMINING FRESH-AIRFLOW

FOR FIREPLACE LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =__________cu. ft. (volume of space)

Example: Space size 16 ft. (length) x 14 ft. (width) x 8 ft. (ceiling height) = 1792 cu. ft.

(volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

_ ________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)

Example: 1792 cu. ft. (volume of space) x

20 = 35,840 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-freefireplace

___________ Btu/Hr

Gas water heater*

___________ Btu/Hr

Gas furnace

___________ Btu/Hr

Vented gas heater

___________ Btu/Hr

Gas fireplace logs

___________ Btu/Hr

Other gas appliances* +_________ Btu/Hr

Confined and Unconfined Space

The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whosevolumeisnotlessthan50cubicfeetper 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space.Roomscommunicatingdirectlywiththe space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

Total

=__________ Btu/Hr

* Do not include direct-ventgas appliances.

Direct-ventdraws combustion air from the outdoors and vents to the outdoors.

Example:

 

 

 

Gas water heater

_

30,000

Btu/Hr

Vent-freefireplace

_+

10,000

Btu/Hr

Total

_= 40,000

Btu/Hr

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________Btu/Hr (maximum space can support)

_ ______ Btu/Hr (actual amount used)

Example: 35,840 Btu/Hr (maximum the space can support)

40,000 Btu/Hr (actual amount of

Btu/Hr used)

124979-01C

www.fmiproducts.com

7

AIR FOR COMBUSTION AND VENTILATION

Continued

The space in the previous example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.

B.Vent room directly to the outdoors. See

Ventilation Air From Outdoors.

C.Install a lower Btu/Hr fireplace, if lower Btu/ Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING:Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoor combustion air, combustion and ventilation air shall be provided by one of the methods described in theNational Fuel GasCode,ANSIZ223.1/NFPA54, theInternational Fuel Gas Code, or applicable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 5). You can also remove door into adjoining room (see option 3, Figure 5). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

 

12"

Ventilation

 

Ventilation Grills

Grills Into

 

 

Into Adjoining Room,

Adjoining

Or

Option 2

Room,

Remove

 

Option 1

Door into

 

 

Adjoining

 

 

Room,

 

 

Option

 

 

3

 

12"

Figure 5 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo-stat-controlledpower vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 6 - Ventilation Air from Outdoors

8

www.fmiproducts.com

124979-01C

Installation

NOTICE: This heater is intended for use as supplemental heat. Use thisheateralongwithyourprimary heating system. Do not install this heaterasyourprimaryheatsource. Ifyouhaveacentralheatingsystem, you may run system’s circulating blowerwhileusingheater.Thiswill help circulate the heat throughout the house. In the event of a power outage,youcanusethisheateras your primary heat source.

WARNING: A qualified service person must install fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

wherecurtains,furniture,clothingorotherflammableobjects arelessthan36"fromthefront, top or sides of the fireplace

as a fireplace insert

in high traffic areas

in windy or drafty areas

WARNING: Never install in a bedroomorbathroom.Anyheating product with a Btu/Hr rating over 10,000 cannot be used in a bedroom.

CAUTION: This fireplace createswarmaircurrents.Thesecurrents move heat to wall surfaces nexttofireplace.Installingfireplace nexttovinylorclothwallcoverings oroperatingfireplacewhereimpurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-freefireplaces add moisture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. SeeAir for Combustion and Ventilation, page 6.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surfaceontherear,sidesortopofyourfireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Note: When installing fireplace directly on carpeting, tile or other combustible material, otherthanwoodflooring,thefireplaceshallbe installed on a metal or wood panel extending the full width and depth of the fireplace.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, page 10).

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install fireplace. Call dealer where you bought fireplace for proper type fireplace.

WARNING: This appliance is equipped for either natural gas or propane/LP gas but not both.

Gas type is indicated on the ratingplate.Fieldconversionisnot permitted.

INSTALLATION ITEMS

Before installing fireplace, make sure you have the items listed below.

external regulator (supplied by installer, for propane/LP units only)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection*

ground joint union

sediment trap

tee joint

pipe wrench

* An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer. See Accessories, page 31.

124979-01C

www.fmiproducts.com

9

INSTALLATION

Continued

Fireplace Clearances

WARNING: Maintain the minimum clearances shown in Figure 7. If you can, provide greater clearances from floor, ceiling and joining wall.

If your fireplace is to be used with an optional mantel, the installation instructions included with your mantel shows an approved method of attaching the fireplace/mantel system to a wall. IMPORTANT: Only use optional cabinet or corner mantels specified in this manual.

Purchase the optional mantel from your dealer (see Accessories, page 31).

If your fireplace is to be recessed into the wall, see Built-In Fireplace Installation on page 10 to secure your fireplace into the wall.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 36".

C.For mantel clearances, see Figure 11 on page 12.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top 36", Left and Right Sides 6",

Bottom and Rear 0", Front 36"

Example

*

CAUTION: If you install the fireplace in a home garage

fireplacepilotandburnermust be at least 18" above floor.

locatefireplacewheremoving vehicle will not hit it.

For convenience and efficiency, install fireplace

where there is easy access for operation, inspection and service

in coldest part of room

An optional blower kit is available from your dealer. See Accessories, page 31. If planning to use blower, follow instructions provided with blower for power source.

Minimum Clearances For Side Combustible Material, Side Wall and

Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 31/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 7).

*Minimum 16" from Side Wall

Figure 7 - Minimum Clearance for Combustible to Wall

Built-InFireplace Installation

Built-ininstallation of this fireplace involves installing fireplace into aframed-inenclosure. This makes the front of fireplace flush with wall. Trim will extend past sides of fireplace approximately 1/2". This will cover the rough edges of the wall opening. If installing a builtin mantel above the fireplace, you must follow the clearances shown in Figure 11, page 12. Follow the instructions below to install the fireplace in this manner.

 

Actual

Framing

 

 

 

Height

26"

26 7/8"

Front Width

26 3/4"

26 7/8"

Depth

14 1/4"

15 1/4"

1.Frame in rough opening. Use dimensions shown in Figure 8, page 11, for the rough opening. If installing in a corner, use dimensions shown in Figure 9, page 11, for the rough opening. The height is 26 7/8" which is the same as the wall opening above.

10

www.fmiproducts.com

124979-01C

INSTALLATION

Continued

2.If installing GA3450TA blower accessory, do so at this time. Follow instructions included with blower accessory.

Note: If not installing blower accessory, you may wish to run electrical wiring to yourfireplaceforfutureblowerinstallation

(see Accessories, page 31). Use only approvedthree-wireelectrical wiring.

WARNING: Ifpre-wiring,do notconnectwiringtoanyelectrical source at this time.

Install fireplace electrical outlet and connect wiring to outlet before connecting to electrical source. The fireplace electrical outlet is included with the

GA3450TA blower accessory.

Only use the fireplace electrical outletsuppliedwiththeGA3450-

TA blower accessory.

Note: A qualified installer should make all electrical connections.

15 1/4"

26 7/8"

26 7/8"

Figure 8 - Rough Opening for Installing in Wall

435/16"

305/8"

267/8"

611/4"

Figure 9 - Rough Opening for Installing in Corner

3.Install gas piping to fireplace location.This installation includes an approved flexible gas line (if allowed by local codes) after the equipment shutoff valve. The flexible gas line must be the last item installed on the gas piping.

4.If you have not installed hood, follow instructions on page 6.

5.Carefully set fireplace in front of rough opening with back of fireplace inside wall opening.

6.Attach flexible gas line to fireplace gas regulator. See Connecting Equipment Shutoff Valve to Heater Control, page 14.

7.Bend four nailing flanges on outer casing with pliers (see Figure 10).

8.Attach fireplace to wall studs using nails or wood screws through holes in nailing flange.

9.Check all gas connections for leaks. See

Checking Gas Connections, page 14.

10.If using optional trim kit, install the trim after final finishing and/or painting of wall. See instructions included with trim accessory for attaching trim.

IMPORTANT: When finishing your firebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood, etc. may be butted up next to the sides and top edge of the firebox. Combustible materials should never overlap the firebox front facing.

Wall Studs

Nailing

Flanges

Nails or Wood

Screws

Figure 10 - Attaching Fireplace to Wall Studs

124979-01C

www.fmiproducts.com

11

INSTALLATION

Continued

WARNING: Do not allow any combustible/noncombustible materials to overlap the firebox front facing.

WARNING: Do not allow combustible or noncombustible materialstocoveranynecessary openings like louvered slots.

WARNING: Never modify or cover the louvered slots on the front of the firebox.

Mantel Clearances for Built-InInstallation

If placing mantel above built-infireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening.

NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:

raise the mantel to an acceptable height

remove the mantel

Removing Upper Louver

To install mantel or blower accessory, you must first remove the upper louver.

1.Lift screen off fireplace and remove log set if installed.

2.Remove 4 screws from upper louver (see Figure 12). Save these screws.

3.Pull upper louver straight out from the cabinet. Be careful not to scratch the paint. Set louver aside.

4.Open lower louver door by swinging door down (see Figure 12).

NOTICE: Surface temperatures ofadjacentwallsandmantelsbecomehotduringoperation.Walls and mantels above the firebox may become hot to the touch.

If installed properly, these temperatures meet the requirement ofthenationalproductstandard.

Follow all minimum clearances shown in this manual.

 

10"

 

 

Mantel Shelf

Note:

 

 

 

 

8"

 

 

 

 

All vertical

 

 

 

 

measurements

6"

 

 

 

 

 

 

 

 

are from top of

 

 

 

 

2 1/2"

 

 

 

 

fireplace

 

 

 

 

opening to

 

 

 

 

 

bottom of

 

 

 

 

 

mantel shelf. All

 

 

 

 

 

measurements

 

 

 

 

 

are in inches.

 

 

 

 

 

 

15"

18"

21"

23"

 

 

 

 

 

 

 

Side of Firebox

Figure 11 - Minimum Mantel Clearances

for Built-InInstallation

Top

Louver

Bottom Louver

Figure 12 - Removing Top Louver and

Opening Bottom Louver

OPTIONAL MANTEL Installation

Refer to instructions provided with the mantel for assembly instructions.

Installing Optional Blower Accessory GA3450TA

Refer to instructions provided with the blower for assembly instructions.

12

www.fmiproducts.com

124979-01C

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 45° male flare fitting

5/8"-18UNF (Unified National FineThread)inletconnectionand the flexible gas line provided.

WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.

WARNING: Never connect natural gas fireplace to private(non-utility)gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: For natural gas, check gas line pressure before connecting fireplace to gas line. Gas line pressure must be no greater than 14" of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION:Neverconnectpropane/LP fireplace directly to the propane/LPsupply.Thisfireplace requires an external regulator

(notsupplied).Installtheexternal regulator between the fireplace and propane/LP supply.

For propane/LP units, the installer must supply anexternalregulator.Theexternalregulatorwill reduceincominggaspressure.Youmustreduce incoming gas pressure to between 11" and 14" ofwater.Ifyoudonotreduceincominggaspressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 13. Pointing the vent down protects it from freezing rain or sleet.

CAUTION:Useonlynew,blackironorsteelpipe.Internally-tinnedcoppertubingmaybeusedincertainareas.Checkyourlocalcodes. Usepipeof1/2"orgreaterdiameter toallowpropergasvolumetofireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPTtap. Locate NPT tap within reach for test gauge hook up.

NPT tap must be upstream from heater (see Figure 14).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

Propane/

LP Supply External Tank Regulator

with Vent

Pointing

Down

Figure 13 - External Regulator With Vent

Pointing Down

Equipment Shutoff Valve

With 1/8" NPT Tap*

Approved

Propane/LP

From External

Flexible

Regulator (11"

Gas Line

W.C.** to 14" W.C.

 

 

Pressure)

 

Natural

 

From Gas Meter

3" Minimum

(5" W.C.** to

10.5" W.C.

 

 

Pressure)

Pipe Nipple Cap Tee Joint

Sediment Trap

Figure 14 - Gas Connection

* Purchase the optional equipment shutoff valve from your dealer. See Accessories, page 31.

124979-01C

www.fmiproducts.com

13

INSTALLATION

Continued

We recommend that you install a sediment trap in supply line as shown in Figure 14, page 13. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze.Asediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not run properly.

CONNECTING equipment shutoff valve to heater control

Installation Items Needed

• Phillips screwdriver

Lower

Louver

Flexible Gas

Line

Figure 15 - Flexible Gas Line Location

(Remote-ReadyUnit Shown)

sealant (resistant to propane/LP gas, not provided)

1. Open lower louver (see Figure 15).

NOTICE: Most building codes do not permit concealed gas connections. A flexible gas line is provided to allow accessibility fromthefireplace(seeFigure14). The flexible gas supply line connection to the equipment shutoff valve should be accessible.

2.Route flexible gas line, included, from fireplace control to equipment shutoff valve through side access holes in outer casing.

3.Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line/equipment shutoff valve

(see Figure 16).

CAUTION: Avoid damage to gas control. Hold gas control with wrench when connecting it to gas piping and/or fittings

4.Check all gas connections for leaks. See

Checking Gas Connections,below. Feed flexible gas line into fireplace. Make sure the entire flexible gas line is in fireplace.

To Control Valve

 

Equipment

 

Shutoff

 

Valve

Flexible Gas Line

 

from Fireplace

 

Gas Regulator

Propane/LP

Provided With

To External Regulator

Fireplace

Natural GAS

 

 

To Gas Supply

Figure 16 - Attaching Flexible Gas Line

to Equipment Shutoff Valve

CHECKING GAS CONNECTIONS

WARNING:Testallgaspiping and connections, internal and external to unit, for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak.

Applyanoncorrosiveleakdetection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

14

www.fmiproducts.com

124979-01C

INSTALLATION

Continued

CAUTION: Make sure external regulator has been installed betweenpropane/LPsupplyand fireplace. See guidelines under

Connecting to Gas Supply, page 13.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 17).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or pro-

Equipment

Open

Shutoff

 

Valve

 

 

Closed

Figure 17 - Equipment Shutoff Valve

pane/LP supply to equipment shutoff valve for propane/LP (see Figures 18 or 19).

Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Fireplace Gas

Connections

1.Open equipment shutoff valve (see Figure 17).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figures 18 or 19).Apply noncorrosiveleakdetectionfluidtoalljoints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operation, page 18).

Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 19.

Equipment

Gas Control Valve Shutoff

Valve

Propane/

LP Supply

Tank

Figure 18 - Checking Gas Joints

(Propane/LP Only)

Gas Control Valve

Equipment

Shutoff Valve

Gas Meter

Figure 19 - Checking Gas Joints

(Natural Gas Only)

124979-01C

www.fmiproducts.com

15

INSTALLATION

Continued

Optional Wall Mounted

Thermostat - GWMT1

WARNING: Read and follow installation instructions.

Installation should be done by aqualifiedinstallerfamiliarwith low-voltagewiring procedures.

WARNING: Do not connect this thermostat to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve

(see Figure 20).

2.Connect one terminal of 25 ft. wire to the “TH” terminal on the control valve. Connect the other terminal to the “THTP” terminal on the control valve. See Figure 22.

3.Route the 25 ft. wire to a convenient location to mount your thermostat (no outside wall). IMPORTANT: The wire may be shortened but must not be lengthened.

The thermostat should be mounted 54" above the floor in a location where there is good air circulation. Avoid heat sources such as lamps, direct sunlight, fireplace or heat and air conditioning ducts.

4.Gently remove cover of thermostat from base. Grasp sides of cover firmly and pull to separate from base.

5.Feed electrical wires through rectangular slots on each side of base (see Figure 23).

WARNING: Do not connect the thermostat to a power source. Electrical shock and/or a fire hazard will occur.

6.Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 24).

7.Install base onto wall with provided screws.

Control Valve

To Wall Thermostat or Switch

To Wall Thermostat or Switch

Figure 22 - Connecting Wire Terminals

Feed wires through rectangular slots

Figure 23 - Back View of Thermostat Base

Terminal “W”

Terminal “R”

Figure 20 - Disconnecting Jumper Wires

From Control Valve

W

R

Figure 24 - Thermostat Base Terminals

“W” and “R”

16

www.fmiproducts.com

124979-01C

INSTALLATION

Continued

8.Move temperature adjustment back and forth to insure the bimetal is free from restrictions.

9.Replace cover onto base. (Upon installation, thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation).

10.Set temperature adjustment to desired setting. This thermostat has been electronically calibrated at the factory. No adjustment or leveling is necessary.

Optional Wall SWITCH - GWMS2

WARNING: Read and follow installation instructions.

Installation should be done by aqualifiedinstallerfamiliarwith low-voltagewiring procedures.

WARNING: Do not connect this switch to any electrical source! Electrical shock and/or fire hazard will occur.

1.Remove jumper wire from control valve (see Figure 20, page 16).

2.Connect one terminal of 25 ft. wire to the

“TH” terminal on the control valve. Connect other terminal to the “THTP” terminal on control valve. See Figure 22.

3.Route the 25 ft. wire to a convenient location to mount your wall switch (no outside walls).

INSTALLING LOG SET AND SCREEN

1.Remove log packaging material and discard packaging. Gently place log over burner (see Figure 25). Do not allow log to contact flame. If flame contacts log, soot will be created.

2.Reattach screen by placing notches in screen frame over shoulder screws and pushing down.

Shoulder

Screw

Log

Screen

Figure 25 - Installing Log and Screen

WARNING: Do not connect the switch to a power source. Electrical shock and/or fire hazard will occur.

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the provided wall switch.

5.Install the wall switch and cover in the wall.

124979-01C

www.fmiproducts.com

17

operation

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must belightedbyhand.Whenlightingthepilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knobwillnotpushinorturnbyhand,don’t trytorepairit,callaqualifiedservicetechnicianorgassupplier.Forceorattempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call aqualifiedservicetechniciantoinspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

WARNING:Youmustoperate this fireplace with the screen in place. Make sure fireplace screen is installed before running fireplace.

NOTICE:Duringinitialoperation of new fireplace, burning logs will give off a paper-burningsmell. Open window to vent smell. Operate fireplace on HI position to burn off odor. This will only last a few hours.

WARNING: Burner will come on automatically within one minute when control valve is in the

ON position after the pilot is lit.

1.STOP! Read the safety information.

2.Make sure equipment shutoff valve is fully open.

3.Press in and turn control knob clockwise

to the OFF position (see Figure 36.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step.

5.Press in and turn control knob counterclockwise to the PILOT position.

Press in control knob for five (5) seconds (see Figure 26, page 19).

Note: You may be running this fireplace for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob.

18

www.fmiproducts.com

124979-01C

Operation Continued

• If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

8.Slightly push in and turn control knob counterclockwiseto the ON position.

9.Set flame adjustment knob to any level between HI and LO.

10.To leave pilot lit and shut off burners only, turn control knob clockwise to PILOTposition. If using optional hand-heldremote, use remote control manual OFF button.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Piezo

Flame

Control

Ignitor

Adjustment

Knob

Button

Knob

 

 

 

Figure 26 - Control Knob and Ignitor

Button Location (Shown as Supplied -

No Control Options)

Pilot

Burner Ignitor

Electrode

Figure 27 - Propane/LP Gas Pilot

Pilot Burner

Ignitor

 

Electrode

Figure 28 - Natural Gas Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise to the OFF position.

2.If Using Optional Hand-HeldRemote:

Set selector switch in the OFF position to prevent draining battery.

3.Close equipment shutoff valve (see Figure

17, page 15).

WARNING: Make sure remote sensor selector switch is in the OFF position when you are away from home for long periods of time.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 17.

2.Press control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob. Now follow steps 8 and 9 under Lighting Instructions.

Optional GWMT1 Wall

mounted Thermostat

Set the temperature adjustment on wall thermostat to the desired setting. The thermostat has been electronically calibrated at the factory and requires no adjustment or leveling.

Upon installation, the thermostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation. See installation instructions on pages 16 and 17.

Optional GWMS2 Wall

Mounted SWITCH

This wall switch works just like the conventional light switch. Flip switch up for on and down for off.

Note: Make sure that this switch is not in a position to be mistaken for a light switch. This may resultinthefireplacebeinginadvertentlyturned on without the proper precautions being taken. See installation instructions on page 17.

124979-01C

www.fmiproducts.com

19

Inspecting Burners

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 30

turn fireplace off (see To Turn Off Gas to Appliance, page 19.

see Troubleshooting, page 22.

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Thermocouple

Figure 29 - Correct Pilot Flame Pattern

(Propane/LP Remote-ReadyShown)

Pilot Burner

Thermocouple

Figure 30 - Incorrect Pilot Flame Pattern

(Propane/LP Remote-ReadyShown)

BURNER FLAME PATTERN

Figure 31 shows a correct burner flame pattern. Figure 32 shows an incorrect burner flame pattern. The incorrect burner flame pattern shows sporadic, irregular flame tipping. The flame should not be dark or have an orange/reddish tinge.

Note: When using the fireplace the first time, theflamewillbeorangeforapproximatelyone hour until the log cures.

If burner flame pattern is incorrect, as shown in Figure 32

turn fireplace off (see To Turn Off Gas to Appliance, page 19.

see Troubleshooting, page 22.

Figure 31 - Correct Burner Flame Pattern

Figure 32 - Incorrect Burner Flame

Pattern

Cleaning and

Maintenance

WARNING:Turnofffireplace

and let cool before cleaning.

CAUTION: You must keep control areas, burner and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have fireplace inspected yearly by a qualified service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding material, etc.

WARNING: Failure to keep the primary air opening(s) of theburner(s)cleanmayresultin sooting and property damage.

Burner Orifice Holder and

Pilot Air Inlet Hole

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair.

Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have fireplace inspected yearly by a qualified service person.

20

www.fmiproducts.com

124979-01C

CLEANING AND MAINTENANCE

Continued

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI.

Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

1.Shut off unit including pilot. Allow unit to cool for at least 30 minutes.

2.Inspect burner, pilot and primary air inlet holes on orifice holder for dust and dirt

(see Figure 33).

3.Blow air through the ports/slots and holes in the burner.

4.Check the orifice holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the orifice holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air

Orifice Holder

Burner

Tube

Primary Air

Inlet Holes

Figure 33 - Orifice Holder On Outlet

Burner Tube

inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figures 34 or 35 depending on model). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet Hole

Pilot Assembly

Figure 34 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Air Inlet Hole

Pilot Assembly

Figure 35 - Pilot Inlet Air Hole

(Natural Gas)

LOG Set

If you remove one-piecelog set for cleaning, refer to page 16, for placement instructions.

Replace log set if broken or chipped (dimesized or larger).

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

Wiring Diagram

(Remote-Ready

 

 

 

Blue

 

 

 

 

 

 

 

 

Models Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TPTH

 

TH

 

 

 

 

Gas Control

 

 

 

Red

TPTH

TP

 

 

Thermopile

 

 

 

 

 

 

 

White

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

124979-01C

www.fmiproducts.com

21

Troubleshooting

WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Whenignitorbuttonispressed, there is no spark at ODS/ pilot

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

 

nected to ignitor cable

 

 

2.

Ignitor cable pinched or

2.

Free ignitor cable if pinched

 

wet

 

by any metal or tubing.

 

 

 

Keep ignitor cable dry

3.

Broken ignitor cable

3.

Replace ignitor cable

4.

Bad piezo ignitor

4.

Replace piezo ignitor

5.

Ignitor electrode positioned

5.

Replace pilot assembly

 

wrong

 

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

Whenignitorbuttonispressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see

Cleaning and Maintenance,page 20) or replace ODS/ pilot assembly

7.Replace gas regulator

22

www.fmiproducts.com

124979-01C

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully

1.

Press in control knob fully

goes out when control knob

 

pressed in

 

 

is released

2. Control knob not pressed in

2.

After ODS/pilot lights, keep

 

 

long enough

 

control knob pressed in 30

 

 

 

 

seconds

 

3.

Safety interlock system has

3.

Wait one minute for safety

 

 

been triggered

 

interlock system to reset.

 

 

 

 

Repeat ignition operation

 

4.

Equipment shutoff valve not

4.

Fully open equipment shut-

 

 

fully open

 

off valve

 

5.

Pilot flame not touching

5.

A) Contact local natural or

 

 

thermocouple, which al-

 

propane/LP gas company

 

 

lows thermocouple to cool,

 

 

 

 

causing pilot flame to go

 

B) Clean ODS/pilot (see

 

 

out. This problem could be

 

Cleaning and Maintenance,

 

 

caused by one or both of

 

page 20) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

6.

Thermocouple connection

6.

Hand tighten until snug,

 

 

loose at control valve

 

then tighten 1/4 turn more

 

7.

Thermocouple damaged

7.

Replace pilot assembly

 

8.

Control valve damaged

8.

Replace control valve

Burner does not light after ODS/pilot is lit

1.Inlet gas pressure is too low

2.Burner orifice is clogged

3.Thermopile leads disconnected or improperly connected (Remote-ReadyModels Only)

4.Burners will not come on in remote position (RemoteReady Models Only)

1.Contact local natural or propane/LP gas company

2.Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice

3.Reconnect leads (see Wiring Diagram, page 21)

4.Replace battery in transmitter and receiver

Delayed ignition of burner

1. Manifold pressure is too

1.

Contact local natural or

 

 

 

low

 

propane/LP gas company

 

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

 

and Maintenance,page 20)

 

 

 

 

 

or replace burner orifice

 

 

 

 

 

Burner backfiring during com-

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

bustion

 

damaged

 

and Maintenance,page 20)

 

 

 

 

 

or replace burner orifice

 

 

2.

Damaged burner

2.

Replace damaged burner

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

4.

Inlet gas pressure is too

4.

Contact local natural or

 

 

 

low

 

propane/LP gas company

124979-01C

www.fmiproducts.com

23

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

Slight smoke or odor during

1.

Residues from manufac-

1.

Problem will stop after a few

initial operation

 

turing processes and log

 

hours of operation

 

 

curing

 

 

 

2.

Not enough air

2.

Check burner for dirt and

 

 

 

 

debris. If found, clean

 

 

 

 

burner (see Cleaning and

 

 

 

 

Maintenance,page 20)

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Fireplaceproducesawhistling 1. Turning control knob to HI

noise when burner is lit

position when burner is

 

cold

2.

Air in gas line

3.

Air passageways on fire-

 

place blocked

4.

Dirty or partially clogged

 

burner orifice

1.Turn control knob to LO position and let warm up for a minute

2.Operate burner until air is removed from line. Have gas line checked by local natural gas company

3.Observe minimum installation clearances (see page 10)

4.Clean burner (see Cleaning and Maintenance, page 20) or replace burner orifice

Whitepowderresidueforming

1.

When heated, vapors from

1.

Turn fireplace off when

within burner box or on adja-

 

furniture polish, wax, carpet

 

using furniture polish, wax,

cent walls or furniture

 

cleaners, etc. may turn into

 

carpet cleaners or similar

 

 

white powder residue

 

products

 

 

 

 

 

Moisture/condensation no-

1.

Not enough combustion/

1.

Refer to Air for Combustion

ticed on windows

 

ventilation air

 

and Ventilation require-

 

 

 

 

ments (page 6)

 

 

 

 

 

Remote does not function

1.

Battery is not installed. Bat-

1.

Replace 9-voltbatteries in

 

 

tery power is low

 

receiver and remote control

 

 

 

 

 

Fireplace produces a clicking/

1.

Metal expanding while

1.

This is normal with most

ticking noise just after burners

 

heating or contracting while

 

fireplaces. If noise is ex-

are lit or shut off

 

cooling

 

cessive, contact qualified

 

 

 

 

service person

24

www.fmiproducts.com

124979-01C

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

Fireplace produces unwant-

1. Fireplace burning vapors

1.

Open window to venti-

 

ed odors

 

from paint, hair spray,

 

late room. Stop using odor

 

 

 

glues, cleaners, chemi-

 

causing products while

 

 

 

cals, new carpet, etc. (See

 

fireplace is running

 

 

 

IMPORTANT statement

 

 

 

 

 

 

above)

 

 

 

 

 

2.

Low fuel supply (propane/

2.

Refill supply tank (propane/

 

 

 

LP only)

 

LP only)

 

 

3.

Gas leak. See Warning

3.

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Con-

 

 

 

 

 

nections, page 14)

 

 

 

 

 

 

 

Fireplace shuts off in use

1. Not enough fresh air is

1.

Open window and/or door

 

(ODS operates)

 

available

 

for ventilation

 

 

2.

Low line pressure

2.

Contact local natural or

 

 

 

 

 

propane/LP gas company

 

 

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

 

clogged

 

Cleaning and Maintenance,

 

 

 

 

 

page 20)

 

 

 

 

 

 

Gas odor even when control

1. Gas leak. See Warning

1.

Locate and correct all leaks

 

knob is in OFF position

 

statement at top of page

 

(see Checking Gas Con-

 

 

 

 

 

nections, page 14)

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

 

Gas odor during combustion

1. Foreign matter between

1.

Take apart gas tubing and

 

 

 

control valve and burner

 

remove foreign matter

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Con-

 

 

 

 

 

nections, page 14)

124979-01C

www.fmiproducts.com

25

Parts

Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1,CDCFNRB-1

9

10

8

10

16

6

14 10

14 16

17 16

15

11

14

16

16

1

14

 

2

 

 

16

16

4

16

14

16

5

14

3

16

14

16

8

18

16

13

12 11 7

19

26

www.fmiproducts.com

124979-01C

Parts

Firebox Models CDCFPRB, CDCFNRB, CDCFPRB-1,CDCFNRB-1

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

KEY

 

 

 

CDCF

 

 

 

 

NO.

PART NO.

DESCRIPTION

 

 

1

**

Outer Casing Top

 

2

**

Baffle

 

3

**

Outer Casing

 

4

104281-02

Firebox Hood

 

5

**

Firebox Top

 

6

**

Firebox Wrapper

 

7

**

Outer Base

 

8

102635-02

Front Left and Right Sides

 

9

103209-05

Extruded Louver

 

10

098304-01

Screw, PPH AB 10-16x 0.38

 

11

M10908-2

Screw, SLTD HWH TPG 6-32x 0.38

 

12

104313-01

Right Pin Hinge

 

13

104313-02

Left Pin Hinge

 

14

099230-02

Screw, HWH SHLDR AB 10 x 0.63

 

15

111038-02

Remote/Blower Bracket

 

16

M11084-26

Screw, HWH AB 10-16x 0.38

 

17

111633-01

Box Cover

 

18

111200-01

Support Bracket

 

19

103295-05

Screen Frame

 

 

** Not a field replacement part

QTY.

1

1

1

1

1

1

1

2

2

12

4

1

1

14

1

35

1

1

1

124979-01C

www.fmiproducts.com

27

Parts

REMOTE-READYMODELS CDCFNRB, CDCFPRB,CDCFNRB-1,CDCFPRB-1

20

4

 

9

 

1

2

 

 

 

 

6

3

 

 

 

7

 

 

8

5

9

 

 

 

10

 

 

 

 

9

11

12 14

12

 

 

 

 

 

21

Natural

 

 

9

Gas Only

 

 

 

 

 

 

 

22

15

16

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

15

 

 

 

18

 

19

 

 

 

17

13

 

 

 

 

28

www.fmiproducts.com

124979-01C

Parts

REMOTE-READYMODELS

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual.

KEY

 

 

NO.

PART NO.

DESCRIPTION

1

111069-01

Dual Burner

2

099056-29

Orifice

 

099056-34

Orifice

3

103342-04

Outlet Tube

 

111195-07

Outlet Tube

4

111124-01

Burner Retainer Spring

5

097809-02

Male Fitting

6

103778-01

ODS Pilot

 

103779-01

ODS Pilot

7

099387-09

Pilot Tube

 

099387-12

Pilot Tube

8098249-01ODS Nut

9M11084-26Screw, HWH AB10-16x 0.38

10

**

Chamber Floor

11110793-01Piezo Bracket

12102445-01Piezo Ignitor with Palnut Fastener

13101628-01Flexible Connector

14098271-10Ignitor Cable

15M12461-26Screw, MX SLT WSR10-32x 3/8

16

111173-01

Remote Valve Bracket

17

103781-02

Gas Valve

 

103781-01

Gas Valve

18101480-12ASM High Temp Wire

19097809-02Male Fitting

20113342-01Log Set

21099918-02Pilot Regulator

22099387-14Pilot Tube

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

901056-01

Brass Flare Adapter Fitting

103470-01

Hardware Pack

100563-01

Warning Plate

103877-01

Lighting Instruction Plate

113140-02

Perimeter Trim Kit

GWMT1

Wall Switch Kit

MLCR-M

Remote Control Kit

** Not a field replacement part

 

 

 

 

 

1

 

1

CDCFPR

 

CDCFNRB

 

CDCFPR

-

CDCFNR

-

B

 

B

B

 

 

 

 

 

 

 

 

 

 

 

 

QTY.

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

2

 

 

 

10

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

4

 

 

 

2

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

1

 

 

 

 

 

1

 

 

 

 

 

1

124979-01C

www.fmiproducts.com

29

Specifications

CDCFPRB, CDCFPRB-1

CDCFNRB, CDCFNRB-1

• Rating (Variable): 17,000/26,000 Btu/Hr

• Rating (Variable): 17,000/26,000 Btu/Hr

Type Gas: Propane/LP

Type Gas: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Max - 14" W.C., Min* - 11" W.C.

 

Max - 10.5" W.C., Min* - 5" W.C.

* For purpose of input adjustment

Replacement Parts

If this product is missing a part or has a broken component, please do not return it to the store.

CallFMIPRODUCTS,LLCat1-866-328-4537to answer questions and replace parts under warranty.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

When calling, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

purchase date

Service Hints

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.

Technical Service

You may have further questions about installation,operation,ortroubleshooting.Ifso,contact FMI PRODUCTS, LLC at 1-866-328-4537.

When calling please have your model and serial numbers of your heater ready.

You can also visit our web site at www.fmiproducts.com.

30

www.fmiproducts.com

124979-01C

Accessories

NOTICE: All accessories may not be available for all fireplace models.

Purchase these accessories from your local dealer. If they can not supply these accessories call FMI PRODUCTS, LLC at 1-866-328-4537for information. You can also write to the address listed on the back page of this manual.

Perimeter Trim Kit

GAP6094 - Platinum

For all models. Optionalthree-sidedperimeter trim kit for custom and recessed installations (when unit is on the floor). Provides a finished appearance by covering rough edges of wall opening. Black trim included with the fireplace.

WALL-MOUNTON/OFF SWITCH GWMS2

For all models. Allows the fireplace to be turned on and off with a wall switch.

WALL-MOUNTTHERMOSTAT

SWITCH - GWMT1

For all models. The desired comfort setting can be selected on the wall thermostat and the fireplace will automatically cycle from pilot to the heat setting selected.

Brick Liners - Series 3

HFL200 - Aged Almond, Straight Brick Pattern

HFL201 - Aged Red, Straight Brick Pattern

For all models. Allows firebox interior to be aesthetically enhanced.

F

ON

OFF

MODE

SET

THERMOSTAT-CONTROLLED

BLOWER KIT - GA3450TA

For all models. Provides better heat distribution. Makes fireplace more efficient.Automatically turns off and on as needed.

CORNER MANTEL WITH Full

HEARTH BASE

C26GO - Oak Finished, Georgian Design

C26TO - Medium Oak Finished,

Traditional Design

C26TU - Unfinished, Traditional Design

RECEIVER AND HAND-HELDTHERMOSTAT REMOTE CONTROL

KIT - CTRC

For all Remote-ReadyModels.Allows the fireplace to be operated in a manually or thermostatically controlled mode.You can turn the fireplace on and off without ever leaving

the comfort of your easy chair.

ON

OFF

For all models. Space saving mantel and hearth base corner design features clean, classic lines. Complete assembly instructions included.

CABINET MANTEL and full hearth base

W26GO - Medium Oak Finished, Georgian Design

W26TO - Medium Oak Finished, Traditional Design

W26TU - Unfinished, Traditional Design

For all models. Complete assembly instructions included.

RECEIVER AND HAND-HELD

REMOTE CONTROL KIT - CMRC

For all Remote-ReadyModels.Allows the fireplace to be turned on and off by using a hand-held remote control.

Gas Appliance Installation Kit - CIKA

For all models.

124979-01C

www.fmiproducts.com

31

Warranty

KEEP THIS WARRANTY

Model (located on product or identification tag)______________________________

Serial No. (located on product or identification tag)___________________________

Date Purchased ___________________________

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products

Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) years from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products

Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.

Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).

This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) years on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.

FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact:

 

 

 

2701 S. Harbor Blvd.

 

Santa Ana, CA 92704

124979-01

www.fmiproducts.com

Rev. C

1-866-328-4537