FMI CDCFNRB User Manual
Size:
1.69 Mb
Download

ComfortFlame TM

by FMI PRODUCTS, LLC

UNVENTED (VENT-FREE)Gas Compact Classic Hearth®

DUAL BURNER Fireplace

OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

US

Shown with Optional Cabinet Mantel/Hearth Base Accessory

Remote-ReadyModels CDCFPRB, CDCFNRB,CDCFPRB-1,

CDCFNRB-1

WARNING: If the information in this manual is not followedexactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other ­flammable vapors and liquids in the ­vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Donottouchanyelectricalswitch;donotuseany phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

Table of Contents

Safety...................................................................

2

Product Identification............................................

4

Optional Remote Control Accessories.................

4

Local Codes.........................................................

5

Product Features..................................................

5

Unpacking............................................................

5

Hood Assembly...................................................

6

Air for Combustion and Ventilation.......................

6

Installation............................................................

9

Operation...........................................................

18

Inspecting Burners.............................................

20

Cleaning and Maintenance................................

20

Wiring Diagram..................................................

21

Troubleshooting.................................................

22

Parts...................................................................

26

Specifications.....................................................

30

Replacement Parts.............................................

30

Service Hints......................................................

30

Technical Service...............................................

30

Accessories........................................................

31

Warranty................................................

Back Page

Safety

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: This is an unventedgas-firedheater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer toAir for Combustion and Ventilation section on page 6 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

WARNING: This product contains and/or generates chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion,electricalshockandcarbon monoxide poisoning.

2

www.fmiproducts.com

124979-01C

SAFETY

Continued

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once!Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this fireplace or its controls can be dangerous.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this fireplace.

WARNING: Do not allow fans toblowdirectlyintothefireplace.

Avoidanydraftsthatalterburner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

Due to high temperatures, the appliance should be located out oftrafficandawayfromfurniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen become very hot when running heater.Keepchildrenandadults away from hot surfaces to avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young children when they are in the room with fireplace. When using the hand-heldremote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace withthefireplacescreeninplace. Make sure fireplace screen is closed before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

124979-01C

www.fmiproducts.com

3

SAFETY Continued

5.Do not use this fireplace as a wood-burn-ing fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.Thisfireplaceisdesignedtobesmokeless. If logs ever appear to smoke, turn off fireplace and call a qualified service person.

Note: During initial operation, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 20.

9.Before using furniture polish, wax, carpet cleaner or similar products, turn fireplace off.Ifheated,thevaporsfromtheseproducts may create a white powder residue within burner box or on adjacent walls or furniture.

10.This fireplace needs fresh air ventilation to run properly.This fireplace has an Oxygen

Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combustion and Ventilation,

page 6. If fireplace keeps shutting off, see

Troubleshooting,page 21.

11.Do not run fireplace

where flammable liquids or vapors are used or stored.

under dusty conditions.

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Never place any objects in the fireplace or on logs.

14.Do not use fireplace if any part has been under water. Immediately call a qualified service technician to inspect the room fireplace and to replace any part of the control system and any gas control which has been under water.

15.Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

16.Operating fireplace above elevations of 4,500 feet could cause pilot outage.

17.Do not operate fireplace if log is broken. Do not operate fireplace if log is chipped (dime-sizedor larger).

18.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity.

19.Provide adequate clearances around air openings.

 

Product Identification

 

Fireplace

 

Fireplace Cabinet

 

Cabinet

 

 

 

 

Hood

 

 

Hood

Screen

 

 

 

 

 

 

Logs

 

 

 

Ignitor

Log

 

 

Button

 

 

Remote Control

Ignitor Button

Control

(Optional)

 

 

 

 

Knob

 

Control Knob

 

 

 

 

Figure 1 - Vent-FreeCompact Dual Flame Fireplace

Optional Remote Control Accessories

There is are two optional remote control that

wall switch

can be purchased separately for Remote-

hand-heldON/OFF remote

Ready Models:

 

wall thermostat

 

 

hand-heldthermostat remote

 

 

See Accessories, page 31.

4

www.fmiproducts.com

124979-01C

Local Codes

Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-firedsupplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-freegas products are prohibited for bedroom and bathroom installation in the

Commonwealth of Massachusetts.

Product Features

Safety Pilot

This fireplace has a pilot with an Oxygen

Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-freeroom fireplaces. The ODS/pilot shuts off the fireplace if there is not enough fresh air.

Piezo Ignition System

This fireplace has a piezo ignitor. This system requires no matches, batteries or other sources to light fireplace.

Unpacking

1.Remove fireplace and hood from carton. Log is wrapped and inside fireplace. Do not remove at this time.

2.Remove all protective packaging applied to fireplace for shipment.

3.Make sure your fireplace includes one hardware packet.

4.Check fireplace for any shipping damage. If fireplace is damaged, call FMI PRODUCTS, LLC at 1-866-328-4537.Please do not return it to the store.

Removing ceramic brick liners (If equipped)

WARNING: Ceramic brick liners are located behind upper louver and must be removed before lighting fireplace.

1.Remove screws from top louver and carefully remove louver (see Figure 2).

2.Remove ceramic brick liners with protective packaging. The brick liners will be installed later.

3.Remove yellow sticker from top of firebox.

4.Replace top louver using screws removed in step 1.

Wrapped

Brick Liners

Top Louver

Screws

Figure 2 - Removing Brick Liners

124979-01C

www.fmiproducts.com

5