ComfortFlame TM

by FMI PRODUCTS, LLC

UNVENTED (VENT-FREE)GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUAL

PFS ®

US

Patent Pending

REMOTE

OFF

HI

LO

N

O T O

O

F F LIP

DUAL BURNER BILTMORE SPLIT OAK

18", 24" AND 30"

THERMOSTATICALLY-CONTROLLED

MODELS

CCL3018PTA/NTA

CCL3924PTA/NTA

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other ­flammable vapors and liquids in the ­vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

For more information, visit www.fmiproducts.com

TABLE OF CONTENTS

Safety...................................................................

2

Product Identification............................................

5

Local Codes.........................................................

5

Unpacking............................................................

5

Product Features..................................................

5

Air for Combustion and Ventilation.......................

6

Installation............................................................

8

Operation...........................................................

18

Inspecting Burners.............................................

20

Cleaning and Maintenance................................

20

Service Hints......................................................

21

Technical Service...............................................

21

Troubleshooting.................................................

22

Optional Positioning of Thermostat Sensing Bulb ..26

Specifications.....................................................

27

Parts...................................................................

28

Accessories........................................................

30

Replacement Parts.............................................

30

Notes..................................................................

31

Warranty...............................................

Back Cover

SAFETY

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: This appliance is for installation only in asolid-fuelburning masonry or UL127 factorybuilt fireplace or in a listed ventless firebox enclosure. It isdesign-certifiedfor these installations in accordance with ANSI

Z21.11.2. Exception: Do not install this appliance in a factory-builtfireplace that includes instructions statingithasnotbeentested or should not be used with unvented gas logs.

WARNING: This is an unventedgas-firedheater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer toAir for Combustion and Ventilation section on page 6 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

2

www.fmiproducts.com

124971-01C

SAFETY

Continued

WARNING: This product contains and/or generates chemicals known to the state of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER:Carbonmonoxide

poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once!Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odormaking agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans toblowdirectlyintothefireplace. Avoidanydraftsthatalterburner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insertorotheraccessorynotapproved for use with this heater.

Due to high temperatures, the applianceshouldbelocatedout oftrafficandawayfromfurniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heaterbaseassemblybecomes very hot when running heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown.Allowsurfacetocool before touching.

Carefully supervise young children when they are in the room with heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

124971-01C

www.fmiproducts.com

3

SAFETY

Continued

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lb. capacity (propane/LP units only).

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

5.This gas log set may not be installed as a vented appliance in a bedroom or bathroom.

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

Creosote will ignite if highly heated.Adirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

7.Do not burn solid-fuelin a masonry or

UL127 factory-builtfireplace in which avent-freeroom heater is installed.

8.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across openings of fireplace.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person.

Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

10.To prevent the creation of soot, follow the instructions in Cleaning and Maintenance, page 20.

11.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated,thevaporsfromtheseproductsmay create a white powder residue within burner box or on adjacent walls or furniture.

12.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 6. If heater keeps shutting off, see

Troubleshooting, page 22.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

16.Do not operate heater if any log is broken. Do not operate heater if a log is chipped

(dime-sizedor larger).

17.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

18.Operating heater above elevations of

4,500 feet could cause pilot outage.

19.Provide adequate clearances around air openings.

4

www.fmiproducts.com

124971-01C

PRODUCT IDENTIFICATION

Log Set

Burner

Piezo

Ignitor

Control Knob

Base Grate

Figure 1 - Vent-FreeGas Log Heater

 

LOCAL CODES

Install and use heater with care. Follow all

 

State of Massachusetts: The installa-

local codes. In the absence of local codes,

tion must be made by a licensed plumber

use the latest edition of

The National Fuel

or gas fitter in the Commonwealth of

Gas Code, ANSI Z223.1/NFPA 54*.

Massachusetts.

*Available from:

 

 

Sellers of unvented propane or natural

American National Standards Institute, Inc.

gas-firedsupplemental room heaters shall

1430 Broadway

provide to each purchaser a copy of 527

New York, NY 10018

CMR 30 upon sale of the unit.

National Fire Protection Association, Inc.

Vent-freegas products are prohibited for

Batterymarch Park

bedroom and bathroom installation in the

Quincy, MA 02269

Commonwealth of Massachusetts.

Note: Where listed vented decorative logs are re-

 

quired, thermostat operation is not permitted.

 

UNPACKING

CAUTION:Donotremovethe data plates from the grate assembly. The data plates contain important product information.

1.Remove logs and heater base assembly from carton. Note: Do not pick up heater base assembly by burners. This could

damage heater. Always handle base assembly by grate.

2.Remove all protective packaging applied to logs and heater for shipment.

3.Check heater for any shipping damage. If heater is damaged call FMI PRODUCTS,

LLC at 1-866-328-4537for replacement parts.Please do not return to the store.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellow flames. This heater is designed for vent-freeoperation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard for unvented heaters. State and local codes in some areas prohibit the use of ventfree heaters.

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-freeroom heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor.This system requires no matches, batteries or other sources to light heater.

124971-01C

www.fmiproducts.com

5

AIR FOR COMBUSTION AND VENTILATION

WARNING: This heater shall notbeinstalledinaroomorspace unless the required volume of indoorcombustionairisprovided by the method described in the

National Fuel Gas Code, ANSI Z223.1/NFPA54, the International Fuel Gas Code,or applicable local codes. Read the following instructionstoinsureproperfresh airforthisandotherfuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burningappliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances.This will insure proper venting of vented fuel-burningappliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel

Gas Code, ANSI Z223.1/NFPA 54, Air for

Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 6 through 8 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6x10-11 kg perpa-sec-m2)or less with openings gasketed or sealedand

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceilingjoints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air.

See Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, proceed to Determining FreshAir Flow for Heater Location.

Confined and Unconfined Space

National Fuel Gas Code, ANSI Z223.1/NFPA

54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000Btu/ hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu/hr (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.

DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =__________cu. ft. (volume of space)

6

www.fmiproducts.com

124971-01C

AIR FOR COMBUSTION AND VENTILATION

Continued

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2,560 cu. ft.

(volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

_ ________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)

Example: 2,560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-freefireplace

___________ Btu/Hr

Gas water heater*

___________ Btu/Hr

Gas furnace

___________ Btu/Hr

Vented gas heater

___________ Btu/Hr

Gas fireplace logs

___________ Btu/Hr

Other gas appliances* +__________ Btu/Hr Total =__________ Btu/Hr

* Do not include direct-ventgas appliances.

Direct-ventdraws combustion air from the outdoors and vents to the outdoors.

Example:

 

40,000

 

Gas water heater

 

Btu/Hr

Vent-freefireplace

+

39,000

Btu/Hr

Total

=

79,000

Btu/Hr

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_ _______ Btu/Hr (maximum the space can support)

_ _______ Btu/Hr (actual amount used)

Example: 51,200 Btu/Hr (maximum the space can support)

79,000 Btu/Hr (actual amount of

Btu/Hr used)

The space in the example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms.

See Ventilation Air From Inside Building.

B.Vent room directly to the outdoors. See

Ventilation Air From Outdoors, page 8.

C.Install a lower Btu/Hr fireplace, if lower Btu/ Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING:Iftheareainwhich theheatermaybeoperateddoes notmeettherequiredvolumefor indoorcombustionair,combustion and ventilation air shall be provided by one of the methods described in theNational Fuel GasCode,ANSIZ223.1/NFPA54, theInternational Fuel Gas Code, or applicable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options

1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and

Ventilation for required size of ventilation grills or ducts.

 

 

12"

Ventilation

 

Ventilation Grills

Grills Into

 

Adjoining

Or

Into Adjoining Room,

Room,

Option 2

Remove

Option 1

 

Door into

 

 

 

 

Adjoining

 

 

Room,

 

 

Option

 

 

3

 

 

 

12"

Figure 2 - Ventilation Air from Inside Building

124971-01C

www.fmiproducts.com

7

AIR FOR COMBUSTION AND VENTILATION

Continued

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, SAir for

Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermo-

stat-controlledpower vent. Heated air entering the attic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat.

Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a centralheatingsystem,youmay run system’s circulating blower while using log heater. This will helpcirculatetheheatfromyour logheaterthroughoutthehouse. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this applianceinaventedconfiguration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

Creosote will ignite if highly heated.Adirtychimneyfluemay createanddistributesootwithin house.Inspectchimneyflueand firebox for damage. If damaged, repair flue and firebox before operating heater.

WARNING: Seal any fresh air vents or ashclean-outdoors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use aheat-resistantsealant. Do not seal chimney flue damper.

8

www.fmiproducts.com

124971-01C

INSTALLATION

Continued

WARNING: Never install the heater

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing or other flammable objects are less than 42" from front, top or sides of heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids,oilorkerosenelamps,etc.)in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-freeheaters add moisture to the air.Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. SeeAir for Combustion and Ventilation, page 6.

CHECK GAS TYPE

Use the correct gas type (natural or propane/

LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND CLEARANCES

(Vent-FreeOperation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances from floor, ceiling and adjoining wall.

MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS

Side Wall 16", Ceiling 42"

LOG SIZING REQUIREMENTS

Minimum Firebox

Log

 

 

Front

Rear

Size

Height

Depth

Width

Width*

18"

17"

14"

24"

20"

24"

17"

14"

28"

21"

* Measured at 14" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listedmanufactured fireplace or certifiedvent-freefirebox.

Minimum Clearances For Side Combustible Material, Side Wall and Ceiling

A.Clearances from side of fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and

protrudes 3 1/2" from the wall. This combustible material must be 4" from side of fireplace opening (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B.Clearances from top of fireplace opening to ceiling should not be less than 42".

WARNING:Thisapplianceis equipped for either natural gas or propane/LPgas but not both. Gas type is indicated on the ratingplate.Fieldconversionisnot permitted.

Example

*

*Minimum 16" from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

124971-01C

www.fmiproducts.com

9

INSTALLATION

Continued

NOTICE: Manual control heaters maybeusedasaventedproduct.

If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go toInstalling Damper Clamp Accessory for Vented Operation, page 12.

Minimum Noncombustible Material

Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up. If noncombustible material is less than 12", you must install the fireplace hood accessory (24" models only). See Figure 5 for minimum clearances.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2" thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least

8" up. If noncombustible material is less than

12", you must install the fireplace hood accessory (24" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figure 6 and 7 on page 11 for minimum clearances.

Noncombus-

Requirements for Safe

tible Material

Installation

Distance (A)

 

12" or more

Noncombustible material

 

okay.

Between 8"

24" Models: Install fireplace

and 12"

hood accessory (GA6050 or

 

GA6053 see Accessories,

 

page 30).

 

18" Model: Noncombustible

 

material okay.

Less than 8"

Noncombustible material

 

must be extended to at least

 

8". See Between 8" and 12",

 

above. If you cannot extend

 

material, you must operate

 

heater with flue damper open.

Heat Resistant

Material

(A)

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clearances in Figure 6, page 11 you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6, page 11).

Determining Minimum Mantel Clearance When Using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7, page 11 when using hood.

10

www.fmiproducts.com

124971-01C

INSTALLATION

Continued

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

 

10"

 

Mantel Shelf

 

Underside

 

 

 

 

 

 

8"

 

 

 

 

 

 

 

 

 

of Mantel

 

6"

 

 

 

 

Shelf

 

2 1/2"

 

 

 

 

 

 

 

 

 

 

All minimum

 

 

 

 

 

distances

 

 

 

 

 

are in inches

Minimum

(A)

 

 

 

 

Log Set

Noncombustible

 

 

 

 

 

 

 

 

24"/30"

Material

12"

18"

20"

22"

24"

Models

 

 

8"

8"

14"

17"

20"

18" Model

 

 

 

 

 

Top of Fireplace

 

 

 

 

 

Opening

 

Minimum

 

Distances to

 

 

 

Noncombustible

Underside of

 

 

 

Material Height

Mantel

 

 

 

Figure 6 - Minimum Mantel Clearances

Without Using Hood

 

 

12"

 

 

Mantel Shelf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Underside

 

 

10"

 

 

 

 

 

 

 

of Mantel

 

 

8"

 

 

 

 

 

 

 

Shelf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6"

 

 

 

 

 

All minimum

 

 

 

 

 

 

 

 

 

2 1/2"

 

 

 

 

 

 

 

 

 

 

 

 

 

distances are

Minimum

 

 

 

 

 

 

 

in inches

 

 

 

 

 

 

 

 

 

 

 

 

Noncombustible

 

 

 

 

 

 

 

 

 

Log Set

Material

 

8"

 

12"

15"

18"

20"

 

 

18",All 24",

 

 

 

 

 

 

30"Models

 

 

 

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fireplace

 

 

Hood

Distances to

 

 

 

Opening

(GA60506 ,and

Underside of

GA6053)2

Mantel

 

NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:

operate logs only with flue damper open

raise mantel to an acceptable height

remove mantel

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring

(see Figure 9).

Combustible

14" Material

Min.

Noncombustible

Material

Figure 8 - Minimum Fireplace Clearances

if Installed at Floor Level

Hearth

5"

Min.

Combustible

Material

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

Figure 7 - Minimum Mantel Clearances

When Using Hood

124971-01C

www.fmiproducts.com

11

INSTALLATION

Continued

INSTALLING HEATER BASE ASSEMBLY

CAUTION:Donotremovethe dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplacefloorwithnoncombustiblematerial.Makesurematerial is secure.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane (propane/LP) gas, not provided

electric drill with 3/16" drill bit

flathead screwdriver

1.Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 10).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Place logs in their proper position on heater base, see Installing Logs on page 16.

5.Center heater base and logs front-to-backandside-to-sidein fireplace.

6.Carefully remove logs without moving heater base.

7.Mark screw locations through holes in mounting brackets (see Figure 11 on page 13). If installing in a brick-bottomfireplace, mark screw locations in mortar joint of bricks.

8.Remove heater base from fireplace.

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. SeeOptional Positioning Of Thermostat Sensing Bulb, page 22.

9.Drill holes at marked locations using 3/16" drill bit.

10.Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 11 on page 13).

Flexible Gas Hose

(if allowed by local codes)

Heater Gas

Regulator

Fitting

Figure 10 - Attaching Flexible Gas Hose

to Heater Gas Regulator

12

www.fmiproducts.com

124971-01C

INSTALLATION

Continued

Masonry

Screw

Mounting

Bracket

Figure 11 - Attaching Base Assembly to Fireplace Floor - Dual Burner Model

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 1/2" NPT (National PipeThread)inletconnectionto the pressure regulator.

WARNING: A qualified servicepersonmustconnectheater to gas supply. Follow all local codes.

CAUTION: Never connect heaterdirectlytothepropane/LP supply. This heater requires an externalregulator(notsupplied). Installtheexternalregulatorbetween the heater and propane/ LP supply.

WARNING: Never connect natural gas fireplace to private(non-utility)gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

* An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer. See Accessories, page 30.

For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

External

Supply Tank

Regulator

 

with Vent

 

Pointing

 

Down

Figure 12 - External Regulator With Vent

Pointing Down

124971-01C

www.fmiproducts.com

13

INSTALLATION

Continued

CAUTION:Useonlynew,blackironorsteelpipe.Internally-tinnedcopper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter orgreatertoallowpropergasvolumetoheater.Ifpipeistoosmall, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPTtap. Locate NPT tap within reach for test gauge hook up.

NPT tap must be upstream from heater (see

Figure 13).

IMPORTANT: Install equipment valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealantthatisresistanttoliquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 14.

Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze.

A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

CAUTION: Avoid damage to regulator. Hold gas regulator with wrench when connecting it to gas piping and/or fittings.

PROPANE/LP

 

From External Regulator

 

(11" W.C.** to 14" W.C.

 

Pressure)

Equipment Shutoff

NATURAL

From Gas Meter

Valve With 1/8" NPT

(5" W.C.** to

Tap*

10.5" W.C.

 

Pressure)

Gas

 

 

Regulator

 

3" Minimum

Tee

Pipe Cap

Approved Flexible

Gas Hose (if allowed

Joint

Nipple

by local codes)

Sediment Trap

Figure 13 - Gas Connection

*Purchase the optional equipment shutoff valve from your dealer.

**Minimum inlet pressure for purpose of input adjustment.

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping and connections, internal and external to unit, for leaks afterinstallingorservicing.Correct all leaks at once.

WARNING:Neveruseanopen flame to check for a leak. Apply a noncorrosive leak detection fluid toalljoints.Bubblesformingshow a leak. Correct all leaks at once.

CAUTION: Make sure external regulator has been installed between propane/LP supply and heater.SeeguidelinesunderConnecting to Gas Supply, page 13.

14

www.fmiproducts.com

124971-01C

INSTALLATION

Continued

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

(3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping by either opening propane/LP supply tank valve for propane/ LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

4.Check all joints of gas supply piping system.

Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 14).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figures 15 and 16).

Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

PRESSURE TESTING HEATER GAS CONNECTIONS

1. Open equipment shutoff valve (see Figure 15).

2. Open main gas valve located on or near

Equipment Open Shutoff

Valve

gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the

OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Figures

15 and 16). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operation, page 19).

Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 20).

Propane/LP

Equipment

Supply Tank

Shutoff Valve

Thermostat Gas Valve

Figure 15 - Checking Gas Joints

(Propane/LP Gas Models)

Equipment

Shutoff Valve

Gas Meter

Thermostat Gas Valve

Figure 16 - Checking Gas Joints (Natural

Gas Models)

Closed

Figure 14 - Equipment Shutoff Valve

124971-01C

www.fmiproducts.com

15

INSTALLATION

Continued

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log.

With the heater set to HI, check toseeifflamescontactanylog.If so,repositionlogsaccordingto the log installation instructions in this manual. Flames contacting logs will create soot.

WARNING:Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with thisheatermayresultinproperty damage or personal injury.

INSTALLING LOGS

Dual Burner Biltmore Split Oak Models CCL3018PTA/NTA, CCL3924PTA/NTA

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs.

Only use logs supplied with heater.

1.Place front log (#1) on grate fingers. Make sure front log rests firmly between grate fingers and grate base (see Figure 17).

2.Place base of middle log (#2) in U-shapedslots of grate base. Cutout on right of

middle log should fit over burner (see Figure 18). Make sure front of middle log is resting on tabs of grate base.

3.Locate pins on bottom of back log (#3).

Slide these pins into holes in grate base behind burner (see Figure 19).

Middle

Log (#2)

Burner

Tab

U-ShapedSlot

 

Figure 18 - Installing Middle Log #2

(CCL3924PTA/NTA Shown)

Pins

Rear

Log (#3)

Hole in

Grate Base

Burner

Front

Log (#1)

Figure 19 - Installing Rear Log #3

(CCL3924PTA/NTA Shown)

Grate

Fingers

Grate

Base

Figure 17 - Installing Front Log #1

(CCL3924PTA/NTA Shown)

4.Locate holes on bottom of crossover log (#4). Slide front hole onto left pin (CCL3924PTA/

NTA) or middle pin (CCL3018PTA/NTA) on middle log (#2) and pin on back log (#3).

See Figure 20 on page 17, for placement.

5.For CCL3924PTA/NTA Only: Locate pin and hole on bottom of crossover log (#5).

Slide pin into hole located in crossover log

(#4). Slide hole onto pin on front log (#1). See Figure 21 on page 17.

16

www.fmiproducts.com

124971-01C

INSTALLATION

Continued

 

 

Crossover

Crossover

Crossover

Crossover

 

 

Log (#4)

Log (#6)

 

Pins

Log (#4)

Log (#5)

Middle

 

 

 

 

 

Log (#2)

 

Back Log

Middle

 

 

 

 

(#3)

Log (#2)

 

 

 

Front

Figure 20 - Installing Crossover Log #4

Log (#1)

 

(CCL3924PTA/NTA Shown)

Figure 22 - Installing Crossover Log #5

Crossover

and Log #6 (CCL3018PTA/NTA Only)

Log (#5)

 

Crossover

Crossover

Log (#6)

Log (#4)

 

 

6

 

Pins

Front Log (#1)

Middle

Front

Log (#2)

Figure 21 - Installing Crossover Log #5 Log (#1)

 

(CCL3924PTA/NTA Shown)

 

For CCL3018PTA/NTA Only: Locate holes on bottom of crossover log (#5).

Slide holes over left pins on middle log

(#2) and front log (#1). See Figure 22.

6.Locate holes on bottom of crossover log

(#6). Slide these holes onto right pins located in middle log (#2) and front log (#1).

See Figure 23, for CCL3924PTA/NTA. See

Figure 22 for CCL3018PTA/NTA.

7.Add lava rock around base of heater if desired. Do not place any lava rock on logs or burner.

Figure 23 - Installing Crossover Log #6

(CCL3924PTA/NTA Shown)

124971-01C

www.fmiproducts.com

17

OPERATION

THERMOSTAT-CONTROLLEDMODELS

 

 

 

 

 

 

 

FOR YOUR SAFETY

 

LIGHTING

 

 

 

 

 

 

READ BEFORE LIGHTING

 

 

 

INSTRUCTIONS

 

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WARNING

If fireplace has glass doors, never operate this heater with glass doors closed. If you operateheaterwithdoorsclosed, heat buildup inside fireplace willcauseglasstoburst.Make suretherearenoobstructions across openings of fireplace.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE:Duringinitialoperation of new heater, burning logs will give off a paper-burningsmell. Orange flame will also be present. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room.

However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.

18

www.fmiproducts.com

124971-01C

OPERATION

Continued

THERMOSTAT-CONTROLLEDMODELS

5.Turn control knob counterclockwise

to the PILOT position. Press in control knob for five (5) seconds (see

Figure 31).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more.

This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot.

The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise

to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

9.Turn control knob clockwiseto the

PILOT position to shut off burner leaving pilot lit.

 

HI

LO

OFF

Pilot

Ignitor

Pilot Burner

Electrode

 

Thermocouple

Figure 25 - Pilot

TO TURN OFF GAS

TO APPLIANCE

1.Turn control knob clockwiseto the OFF position.

2.Close equipment shutoff valve (see Figure

16, page 15).

THERMOSTAT

CONTROL OPERATION

The thermostat control knob can be set to any comfort level between HI and LO. The thermostat will gradually modulate the heat output and flame height from higher to lower settings or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the HI setting with the control knob will cause the burners to remain fully on, without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 21.

2.Press control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot.After 30 seconds, release control knob. Now follow step 8, under Lighting Instructions, column 1.

Ignitor Button

Control Knob

 

Figure 24 - Control Knob and Ignitor

Button Location

124971-01C

www.fmiproducts.com

19

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 26 shows a correct pilot flame pattern. Figure 27 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown

in Figure 27.

Pilot Burner

Thermocouple

Figure 26 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 27 - Incorrect Pilot Flame Pattern

turn heater off (see To Turn Off Gas to Appliance, page 19.

see Troubleshooting, page 22.

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust, lint or pet hair. Periodically inspect these holes for any blockage and clean as necessary.

Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage.

Blocked burner flame holes will create soot.

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner and circulatingairpassagewaysofheater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualifiedserviceperson.Heater may need more frequent cleaning due to excessive lint from carpeting,beddingmaterial,pet hair, etc.

WARNING: Failure to keep the primary air opening(s) of theburner(s)cleanmayresultin sooting and property damage.

BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint and pet hair.

Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI.

Your local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could damage the pilot assembly.

20

www.fmiproducts.com

124971-01C

CLEANING AND MAINTENANCE

Continued

1.Shut off unit, including pilot. Allow unit to cool for at least thirty minutes.

2.Inspect burner, pilot and primary air inlet holes on injector holder for dust and dirt

(see Figure 28).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot flame comes out of the pilot assembly (see Figure 29). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Burner Tube

Injector Holder

Primary Air

Inlet Holes

Ports/Slots

Burner Tube

Pilot Assembly

Pilot Air

Inlet Hole

Figure 29 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to

Installing Logs, page 16, to properly replace logs.

Replace log(s) if broken or chipped (dimesized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage.

Blocked burner flame holes will create soot.

Figure 28 - Injector Holder On Outlet

Burner Tube

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

for propane/LP units, propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local propane/LP or natural gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting.

If so, contact FMI PRODUCTS, LLC at

1-866-328-4537.When calling please have your model and serial numbers of your heater ready.

You can also visit FMI PRODUCTS, LLC’s web site at www.fmiproducts.com.

124971-01C

www.fmiproducts.com

21

TROUBLESHOOTING

WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

When ignitor button is pressed, there is no spark at ODS/pilot

1.Ignitor electrode not connected to ignitor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing.

Keep ignitor cable dry

3.Tighten nut holding piezo ignitor to base panel of log set. Nut is located behind base panel

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is

1. Gas supply turned off or

1.

Turn on gas supply or open

pressed, there is spark at

 

equipment shutoff valve

 

equipment shutoff valve

ODS/pilot but no ignition

 

closed

 

 

 

2.

Control knob not in PILOT

2.

Turn control knob to PILOT

 

 

position

 

position

 

3.

Control knob not pressed in

3.

Press in control knob while

 

 

while in PILOT position

 

in PILOT position

 

4.

Air in gas lines when in-

4.

Continue holding down

 

 

stalled

 

control knob. Repeat ignit-

 

 

 

 

ing operation until air is

 

 

 

 

removed

 

5.

Depleted gas supply (pro-

5.

Contact local propane/LP

 

 

pane/LP only)

 

gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see

 

 

 

 

Cleaning and Maintenance,

 

 

 

 

page 20) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

correct

 

 

22

www.fmiproducts.com

124971-01C

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

ODS/pilot lights but flame

1. Control knob not fully

1.

Press in control knob fully

goes out when control knob

 

pressed in

 

 

 

is released

2. Control knob not pressed in

2.

After ODS/pilot lights, keep

 

 

long enough

 

control knob pressed in 30

 

 

 

 

seconds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shut-

 

 

fully open

 

off valve

 

4.

Pilot flame not touching

4.

A) Contact local propane/

 

 

thermocouple, which al-

 

LP or natural gas com-

 

 

lows thermocouple to cool,

 

pany

 

 

causing pilot flame to go

 

 

 

 

 

out. This problem could be

 

B) Clean ODS/pilot (see

 

 

caused by one or both of

 

Cleaning and Maintenance,

 

 

the following:

 

page 20) or replace ODS/

 

 

A) Low gas pressure

 

pilot assembly

 

 

B) Dirty or partially clogged

 

 

 

 

 

ODS/pilot

 

 

 

 

5.

Thermocouple connection

5.

Hand tighten until snug,

 

 

loose at control valve

 

then tighten 1/4 turn more

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

 

 

 

 

Burner doesn't light after

1. Burner orifice clogged

1.

Clean burner (see Cleaning

ODS/pilot is lit

 

 

 

and Maintenance, page 20)

 

 

 

 

or replace burner orifice

 

2.

Inlet gas pressure is too

2.

Contact local propane/LP

 

 

low

 

or natural gas company

 

 

 

 

 

Delayed ignition of burner

1. Manifold pressure is too

1.

Contact local propane/LP

 

 

low

 

or natural gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning

 

 

 

 

and Maintenance, page 20)

 

 

 

 

or replace burner orifice

 

 

 

 

 

Burner backfiring during

1. Burner orifice is clogged or

1.

Clean burner (see Cleaning

combustion

 

damaged

 

and Maintenance, page 20)

 

 

 

 

or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

 

Slight smoke or odor during

1. Not enough air

1.

Check burner for dirt and

initial operation

 

 

 

debris. If found, clean

 

 

 

 

burner (see Cleaning and

 

 

 

 

Maintenance, page 20)

 

2.

Gas regulator defective

2.

Replace gas regulator

 

3.

Residues from manufac-

3.

Problem will stop after a few

 

 

turing processes and logs

 

hours of operation

 

 

curing

 

 

 

124971-01C

www.fmiproducts.com

23

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Moisture/condensation no-

1.

Not enough combustion/

1.

Refer to Air for Combustion

ticed on windows

 

ventilation air

 

and Ventilation require-

 

 

 

 

ments (page 6)

 

 

 

 

 

Heater produces a whistling

1.

Turning control knob to HI

1.

Turn control knob to LO or

noise when burner is lit

 

or position 5 when burner is

 

position 1 and let warm up

 

 

cold

 

for a minute

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

removed from line. Have

 

 

 

 

gas line checked by local

 

 

 

 

propane/LP or natural gas

 

 

 

 

company

 

3.

Air passageways on heater

3.

Observe minimum installation

 

 

blocked

 

clearances (see page 9)

 

4.

Dirty or partially clogged

4.

Clean burner (see Cleaning

 

 

burner orifice

 

and Maintenance, page 03)

 

 

 

 

or replace burner orifice

 

 

 

 

 

White powder residue form-

1.

When heated, vapors from

1.

Turn heater off when us-

ing within burner box or on

 

furniture polish, wax, carpet

 

ing furniture polish, wax,

adjacent walls or furniture

 

cleaners, etc. may turn into

 

carpet cleaners or similar

 

 

white powder residue

 

products

 

 

 

 

 

Heater produces a clicking/

1.

Metal expanding while

1.

This is normal with most

ticking noise just after burner

 

heating or contracting while

 

heaters. If noise is exces-

is lit or shut off

 

cooling

 

sive, contact qualified ser-

 

 

 

 

vice person

24

www.fmiproducts.com

124971-01C

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted

1.

Heater burning vapors from

1.

Open window and venti-

odors

 

paint, hair spray, glues,

 

late room. Stop using odor

 

 

cleaners, chemicals, new

 

causing products while

 

 

carpet, etc. (See IMPOR-

 

heater is running

 

 

TANT statement above)

 

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Con-

 

 

 

 

nections, page 15)

 

 

 

 

 

Heater shuts off in use

1.

Not enough fresh air is avail-

1.

Open window and/or door

(ODS operates) temperature

 

able

 

for ventilation

drops to a lower than ideal

2.

Low line pressure

2.

Contact local propane/LP

level before log set comes

 

 

 

or natural gas company

back on

3.

ODS/pilot is partially

3.

Clean ODS/pilot (see

 

 

clogged

 

Cleaning and Maintenance,

 

 

 

 

page 20)

 

 

 

 

 

Gas odor even when control

1.

Gas leak. See Warning

1.

Locate and correct all leaks

knob is in OFF position

 

statement above

 

(see Checking Gas Con-

 

 

 

 

nections, page 15)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between

1.

Take apart gas tubing and

 

 

control valve and burner

 

remove foreign matter

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

statement above

 

(see Checking Gas Con-

 

 

 

 

nections, page 15)

 

 

 

 

 

Logs set cycles to pilot, but

1.

Thermostat sensing bulb

1.

Reposition thermostat

room temperature drops to a

 

needs to be repositioned

 

sensing bulb (see Optional

lower than ideal level before

 

 

 

Positioning of Thermostat

log set comes back on

 

 

 

Sensing Bulb,beginning on

 

 

 

 

page 26.)

124971-01C

www.fmiproducts.com

25

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB

FOR MASONRY AND FACTORYBUILT METAL FIREPLACE

If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located on the gas valve assembly. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. If positioning the thermostat sensing bulb elsewhere, follow these directions.

Tools needed: 5/16" hex driver or socket

1.Locate the gas valve assembly and thermostat sensing bulb (see Figure 30).

Gas Valve

Assembly

Mounting

Thermostat

Bracket

Sensing

 

Bulb

Figure 30 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

2.With 5/16” hex driver or socket, loosen the thermostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 31).

Note: Do not remove screw. Make sure you tighten screw after removing thermostat sensing bulb.

IMPORTANT: Do not force or bend thermostat sensing bulb or capillary.

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Place bulb in an area that will be close to room temperature when log set is operating

Capillary

Thermostat Screw

Retaining

 

Clamp

 

 

Thermostat

 

Sensing

 

Bulb

Figure 31 - Removing Thermostat

Sensing Bulb

26

www.fmiproducts.com

124971-01C

SPECIFICATIONS

DUAL BURNER BILTMORE SPLIT OAK MODELS

CCL3018PTA

CCL3018NTA

16,000/30,000 Btu/hr (Variable)

16,000/30,000 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.Cs.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.

CCL3924PTA

CCL3924NTA

20,000/39,000 Btu/hr (Variable)

20,000/39,000 Btu/hr (Variable)

Gas Type: Propane/LP

Gas Type: Natural

Ignition: Piezo

Ignition: Piezo

• Manifold Pressure: 8" W.C.

• Manifold Pressure: 3.5" W.C.

• Inlet Gas Pressure (in. of water):

• Inlet Gas Pressure (in. of water):

 

Maximum 14" W.C. Minimum* 11" W.C.

 

Maximum 10.5" W.C. Minimum* 5" W.C.

* For the purpose of input adjustment

124971-01C

www.fmiproducts.com

27

PARTS

THERMOSTATICALLY-CONTROLLEDBILTMORE SPLIT OAK MODELS

CCL3018PTA, CCL3018NTA, CCL3924PTA AND CCL3924NTA

Peg positions vary according to model.

2

1

20

13

 

 

7

 

15

12

 

6

 

 

 

 

725

 

11

 

 

 

16

8

 

10

 

 

 

23

17

 

 

 

 

23

23

18

 

9

21 19

23

28

www.fmiproducts.com

124971-01C

PARTS

THERMOSTATICALLY-CONTROLLEDBILTMORE SPLIT OAK MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the

instructions listed under Replacement Parts on page 30 of this manual

NO. PART NO.

DESCRIPTION

CCL3018PTA

CCL3018NTA

 

CCL3924PTA

 

CCL3924NTA

KEY

 

 

 

 

 

 

 

 

 

1

111340-02

Front Log (#1)

 

 

 

 

 

111340-03

Front Log (#1)

 

 

 

 

2

111341-02

Middle Log (#2)

 

 

 

 

 

111341-03

Middle Log (#2)

 

 

 

 

3

111342-02

Back Log (#3)

 

 

 

 

 

111342-03

Back Log (#3)

 

 

 

 

4

111343-02

Left Back Crossover Log (#4)

 

 

 

 

 

111343-03

Left Back Crossover Log (#4)

 

 

 

 

5

111344-01

Left Top Crossover Log (#5)

 

 

 

 

 

111344-02

Left Top Crossover Log (#5)

 

 

 

 

6

111345-02

Right Bottom Crossover Log (#6)

 

 

 

 

 

111345-03

Right Bottom Crossover Log (#6)

 

 

 

 

7

099211-01

Hex Screw, 10-16x 2.50

 

 

8

102844-01

Lower Bracket

 

 

 

 

 

102844-02

Lower Bracket

 

 

 

 

9

**

Painted Base Assembly

 

 

10

098867-10

Gas Regulator

 

 

 

 

 

098867-14

Gas Regulator

 

 

 

 

11

102810-03

Inlet Tube

 

 

12

102983-05

Outlet Burner Tube

 

 

 

 

 

102983-06

Outlet Burner Tube

 

 

 

 

13

099056-16

Burner Orifice Injector

 

 

 

 

 

 

099056-17

Burner Orifice Injector

 

 

 

 

 

 

099056-19

Burner Orifice Injector

 

 

 

 

 

 

099056-26

Burner Orifice Injector

 

 

 

 

 

14

111124-01

Burner Retainer Spring

 

 

 

 

15

102772-01

Burner

 

 

 

 

 

102980-01

Burner

 

 

 

 

16

101329-19

Thermostat Gas Valve Assembly

 

 

 

 

 

 

101329-20

Thermostat Gas Valve Assembly

 

 

 

 

 

 

101329-21

Thermostat Gas Valve Assembly

 

 

 

 

 

 

101329-22

Thermostat Gas Valve Assembly

 

 

 

 

 

17

102979-01

Thermostat Bracket

 

 

 

 

 

102979-02

Thermostat Bracket

 

 

 

 

18

098544-01

Thermostat Clip

 

 

19

097159-04

Piezo Ignitor

 

 

20

099387-09

Pilot Tube

 

 

21

098271-10

Ignitor Cable

 

 

22

104285-01

ODS Pilot NG

 

 

 

 

 

104286-01

ODS Pilot LP

 

 

 

 

23

M11084-38

Hex Screw, #8-18x 0.38

 

 

24

098249-01

Nut, M5

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100563-01

Warning Plate

 

 

 

101054-01

Lighting Instructions Plate

 

 

 

100639-01

Caution Decal

 

 

 

101137-02

Hardware Kit

 

 

 

GA6060

Lava Rock

 

 

** Not a field replaceable part.

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

12

2

1

1

1

1

1

124971-01C

www.fmiproducts.com

29

ACCESSORIES

Purchase these accessories from your local dealer. If they can not supply these accessories, call FMI PRODUCTS, LLC at 1-866-328-4537for information. You can also write to the address listed on the back page of this manual.

LAVA ROCK - GA6060

For all models. Order when additional rock is desired.

DECORATIVE ASH BED/CONTROL COVER KIT - CDABKA

For all models. Order when additional loose logs are desired.

GAS APPLIANCE INSTALLATION KIT - CIKA

For all models.

FIREPLACE HOOD

GA6050 (Black) GA6053 (Antique Brass)

For all models. Helps deflect heat away from mantel or wall above fireplace.

REPLACEMENT PARTS

If this product is missing a part or has a broken component, please do not return it to the store.

Call FMI PRODUCTS, LLC at 1-866-328-4537to answer questions and replace parts under warranty.

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

When calling, have ready:

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

purchase date

30

www.fmiproducts.com

124971-01C

NOTES

_____________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

_____________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

_____________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

______________________________________________________

124971-01C

www.fmiproducts.com

31

WARRANTY

KEEP THIS WARRANTY

Model (located on product or identification tag)______________________________

Serial No. (located on product or identification tag)___________________________

Date Purchased ___________________________

Keep receipt for warranty verification.

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products

Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of two (2) year from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of first purchase.

Factory Reconditioned Products

Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:

Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.

This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allowance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.

Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.

Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).

This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and fitness for a particular purpose to two (2) year on new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.

FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For information about this warranty contact:

 

 

124971-01