Residential & Light Commercial HVAC
Split System Air Conditioner
11⁄2 thru 5 Tons
208/230 Volt, 1-Phase, 60 Hz
Rated in Accordance with ARI Standard 210. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at www.aridirectory.org
Performance:
Efficiency rating of 13 SEER and 14 SEER Cooling capacities from 11⁄2 to 5 tons
Refrigerant Circuit:
Factory installed liquid line filter drier Long life copper tubes, aluminum fins State-of-the-art compressors
Large, wrap-around coil surface
Quality Built:
Galvanized steel exterior cabinet with 1,000-hour salt spray, powder-coated finish
Powder-coated fan guard
Full louvered panel to protect coil Formed base with 21⁄2" ground clearance Limited 5-year warranty on parts
Easy To Install:
Factory-charged with R-22 refrigerant
Only three screws to access electrical controls Easy access to service valves
|
|
|
|
|
|
|
|
|
|
||
|
Model |
Size |
Nominal |
Min. Circuit |
Max. Fuse or |
Operating Dimensions |
Min. Mounting |
Ship / Operating |
|
||
|
Number |
(tons) |
BTUH |
Ampacity |
Breaker |
H x W x D (inches) |
Pad Size (inches) |
Weight (lbs) |
|
||
|
C18ABD1VF |
1 1⁄2 |
18,000 |
9.1 |
15 |
26 1⁄2 X 21 1⁄2 X 21 1⁄2 |
24 x 24 |
144 / 138 |
|
||
|
|
|
|
|
|
|
|
|
|
||
|
C24ABD1VF |
2 |
24,000 |
11.5 |
15 |
26 1⁄2 X 21 1⁄2 X 21 1⁄2 |
24 x 24 |
142 / 136 |
|
||
|
C30ABD1VF |
2 1⁄2 |
30,000 |
14.3 |
20 |
32 1⁄2 |
X 21 1⁄2 |
X 21 1⁄2 |
24 x 24 |
169 / 163 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C36ACD1VF |
3 |
36,000 |
18.7 |
30 |
32 1⁄2 |
X 29 1⁄2 |
X 29 1⁄2 |
32 x 32 |
189 / 180 |
|
|
C42ACD1VF |
3 1⁄2 |
42,000 |
20.3 |
35 |
32 1⁄2 |
X 29 1⁄2 |
X 29 1⁄2 |
32 x 32 |
213 / 204 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C48ACD1VF |
4 |
48,000 |
23.1 |
40 |
32 1⁄2 |
X 29 1⁄2 |
X 29 1⁄2 |
32 x 32 |
217 / 208 |
|
|
C60ACD1VF |
5 |
60,000 |
30.1 |
50 |
39 X 29 1⁄2 X 29 1⁄2 |
32 x 32 |
230 / 220 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
Product Specifications
PHYSICAL DATA
|
MODEL SIZE |
18 |
24 |
30 |
36 |
42 |
48 |
60 |
|
|
|
|
|
|
|
|
|
|
|
|
PERFORMANCE DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOMINAL CAPACITY (BTUH) |
18,000 |
24,000 |
30,000 |
36,000 |
42,000 |
48,000 |
60,000 |
|
|
|
|
|
|
|
|
|
|
|
|
FAN DATA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
FAN MOTOR TYPE |
PSC |
PSC |
PSC |
PSC |
PSC |
PSC |
PSC |
|
|
|
|
|
|
|
|
|
|
|
|
HP |
1/6 |
1/6 |
1/5 |
1/3 |
1/3 |
1/3 |
1/3 |
|
|
|
|
|
|
|
|
|
|
|
|
DIAMETER |
18" |
18" |
18" |
22" |
22" |
22" |
24" |
|
|
|
|
|
|
|
|
|
|
|
|
BLADE |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
RPM |
1,050 |
1,050 |
1,050 |
1,050 |
1,050 |
1,050 |
950 |
|
|
|
|
|
|
|
|
|
|
|
|
CFM |
1,800 |
1,800 |
1,800 |
3,400 |
3,400 |
3,400 |
4,000 |
|
|
|
|
|
|
|
|
|
|
|
|
OUTDOOR COIL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TYPE |
|
Enhanced Aluminum Plate Fin / Rifled Copper Tube |
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
COIL FACE AREA (ft2) |
9.5 |
9.5 |
12.2 |
18.2 |
18.2 |
18.2 |
22.2 |
|
|
|
|
|
|
|
|
|
|
|
|
O.D. |
7mm |
7mm |
7mm |
7mm |
7mm |
7mm |
7mm |
|
|
|
|
|
|
|
|
|
|
|
|
FPI / ROWS |
18 -2 |
18-2 |
18-2 |
18-1 |
18-2 |
18-2 |
18-3 |
|
|
|
|
|
|
|
|
|
|
|
|
ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MINIMUM CIRCUIT AMPACITY - MCA (amps) 1 |
9.1 |
11.5 |
14.3 |
18.7 |
20.3 |
23.1 |
30.1 |
|
|
|
|
|
|
|
|
|
|
|
|
MAXIMUM OVERCURRENT PROTECTIVE DEVICE-MOCP(amps)2 |
15 |
15 |
20 |
30 |
35 |
40 |
50 |
|
|
COMPRESSOR RLA (Rated Load Amps) |
6.5 |
8.4 |
10.3 |
13.5 |
14.8 |
17 |
22.1 |
|
|
|
|
|
|
|
|
|
|
|
|
COMPRESSOR LRA (Locked Rotor Amps) |
48 |
39 |
61 |
78 |
78 |
86 |
137 |
|
|
|
|
|
|
|
|
|
|
|
|
FAN MOTOR FLA (Full Load Amps) |
1.0 |
1.0 |
1.4 |
1.8 |
1.8 |
1.8 |
1.9 |
|
|
|
|
|
|
|
|
|
|
|
|
REFRIGERANT CONNECTIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LIQUID LINE CONNECTION SIZE (In. OD) |
3/8 |
3/8 |
3/8 |
3/8 |
3/8 |
3/8 |
1/2 |
|
|
|
|
|
|
|
|
|
|
|
|
SUCTION LINE CONNECTION SIZE (In. OD) |
3/4 |
3/4 |
7/8 |
7/8 |
7/8 |
7/8 |
1 1/8 |
|
|
|
|
|
|
|
|
|
|
|
|
RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) |
3/8 |
3/8 |
3/8 |
3/8 |
3/8 |
3/8 |
1/2 |
|
|
|
|
|
|
|
|
|
|
|
|
RECOMMENDED LINE SET SUCTION DIAMETER (In. OD) |
3/4 |
3/4 |
7/8 |
7/8 |
7/8 |
7/8 |
1 1/8 |
|
|
|
|
|
|
|
|
|
|
|
|
FACTORY CHARGE R-22 - OZ. |
72 |
106 |
91 |
87 |
128 |
150 |
204 |
|
|
|
|
|
|
|
|
|
|
|
NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection.
1.Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
2.Time delay fuses may be used in place of HACR circuit breaker.
2
Specifications subject to change without notice.