Enerco HS80CV, HS200CV User Manual

0 (0)
Enerco HS80CV, HS200CV User Manual

OPERATING INSTRUCTIONS AND OWNER’S MANUAL

MR. HEATER

MODEL

MH80CV, MH200CV

 

 

 

READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.

HEATSTAR

MODEL

HS80CV, HS200CV

 

 

 

CONVECTION

CONSTRUCTION HEATER

If the information in this manual is not followed exactly, a fire or explosion WARNING: may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light appliance.

Extinguish any open flame.

Shut off gas to appliance.

Service must be performed by a qualified service agency.

This is an unvented gas-fired portable heater. It uses air (oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to page 3.

ENERCO GROUP, INC., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 216-881-5500

04/04 Revision L2 #70486

WARNING:

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE THIS HEATER.

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

WARNING:

NOT FOR HOME OR RECREATIONAL VEHICLE USE

WARNING:

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.

THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING:

WARNING:

COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM).

TABLE OF CONTENTS

 

HEATER SPECIFICATIONS ..........................................................

2

WARNINGS ...............................................................................

2

OPERATING PRECAUTIONS .......................................................

3

SAFETY PRECAUTIONS ..............................................................

3

ODOR FADE WARNING .............................................................

4

CAUTION: SHELL EXTENSION INSTRUCTIONS. .........................

5

OPERATING INSTRUCTIONS ......................................................

6

SERVICING ................................................................................

6

SIZE AND CAPACITY OF PROPANE CYLINDERS REQUIRED ........

7

80CV - PARTS ............................................................................

8

200CV - PARTS ..........................................................................

9

WARRANTY .............................................................................

12

INSTRUCTIONS FOR ORDERING PARTS ....................................

12

SPECIFICATIONS

Type of Gas: ......

For use with Propane Only

Gas Supply

 

 

Pressure

 

 

to regulator ......

Max.: Bottle Pressure ......

Min.: 80CV

 

 

= 5 psig (34.5 kPa)

 

 

Min.: 200CV

 

 

= 15 psig (103 kPa)

regulator out ....

80CV ..............................

200CV

 

= 11" W.C. (2.74 kPa)

= 10 psig (68.9 kPa)

Ignition: ............

Piezo Ignitor

 

Minimum

 

 

Ambient

 

 

Temp. Rating .....

0°F (-17.8°C)

 

Model: .............

80CV ..............................

200CV

Rating: ..............

30,000-80,000 Btu/hr ....

75,000-200,000 Btu/hr

 

(8.79 - 23.4 kW)

(22.0 - 58.6 kW)

Fuel

 

 

Consumption: ...

1.4 to 3.7 #/hr ................

3.5 - 9.3 #/hr

 

(.74 – 1.80 kg/hr)

(1.44 - 4.32 kg/hr)

Fuel Orifice

 

 

Port No.: ...........

6 .....................................

6

Fuel Orifice

 

 

Port Size: ..........

0.0472" ...........................

0.0320"

 

(1.20mm)

(.813mm)

Enerco Group, Inc. |Convection Construction Heater

2

Operating Instructions and Owner’s Manual

OPERATING PRECAUTIONS

This is a propane, direct-fired, convection heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.

Propane is heavier than air. If propane leaks from a connection or fitting, it sinks to the floor, collecting there with the surrounding air, forming a potentially explosive mixture. Obviously, propane leaks should be avoided, so set up the propane supply with utmost care. Read enclosed Odor Fade and Propane Sheet for additional information about detecting propane leaks. Leak check new connections or reconnections with a soap and water solution and follow all connection instructions herein. Also, ask your propane dealer for advice on the propane application and supply installation and ask him to check it if there are any questions.

This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/CGA 2.14-2000. Check with your local fire safety authority if you have any questions about your applications. Other standards govern the use of fuel gases and heat producting products in specific applications. Your local authority can advise you about these.

Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:

headache

dizziness

burning eyes and nose

nausea

dry mouth or sore throat

So, be sure to follow advice about ventilation in these operating instructions.

When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.

Figure 1

VENTILATION: Minimum openings required

 

 

Opening

Opening

Heater

near floor

near ceiling

Convection 80CV, 200CV ................

2 ft2 ..............................

2 ft2

SAFETY PRECAUTIONS

1.Check the heater thoroughly for damage. DO NOT operate a damagedheater.

2.DO NOT modify the heater or operate a heater which has been modified from its original condition.

3.DO NOT light or operate heater unless the shells are fully extendedandlockedintoposition. Seeenclosedassembly sheet for instructions.

4.Useonlypropanegas.

5.UseonlyVAPORWITHDRAWALpropanesupply.Ifthereis any question about vapor withdrawal, ask your propane dealer.

6.Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them from damage.

7.Locate propane containers at least (USA) 7 ft. (2.13m) for 80CV and 9 ft. (2.7m) for 200CV (Canada)10 ft. (3m) from the heater and do not direct exhaust toward containers.

8.IMPORTANT Useonlythehoseandregulatorassembly provided with the heater. Match the color stripe on the hangtag attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed on parts list before using heater.

9.For indoor use only. Area must be well ventilated. Figure 1. (alsosee"OperatingPrecautions").

10.If atanytime gasodoris detected, IMMEDIATELY DISCONTINUEoperationuntilthesourceofgashasbeen locatedandcorrected.ReadenclosedOdorfadeand Propane Sheet for additional information about detecting propaneleaks.

11.Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.

12.Maintainminimumclearancefromnormalcombustible material (like paper). Figure2.

13.Due to the high surface and exhaust temperatures, adults andchildrenmustobserveclearancestoavoidburnsor clothing ignition.

14.Operate only on a stable, level surface.

15.Do not use with duct work. Do not restrict inlet or exit.

16.Do not move, handle or service while hot or burning.

17.Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling ofLiquefiedPetroleumGasesANSI/NFPA58andCSA B149.1,NaturalGasandPropaneInstallationCode.

Figure 2

MINIMUM CLEARANCE: From normal combustible material

 

80CV, 200CV

Clearance

Convection

From sides ..................................................

4 ft

From top ....................................................

6 ft

Locate 10' from canvas or plastic tarpaulins or similar coverings and secure them to prevent flapping or movement due to wind action.

Enerco Group, Inc. | Convection Construction Heater

3

Operating Instructions and Owner’s Manual

Loading...
+ 7 hidden pages