INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

The Vail Vent-FreeGas Fireplaces

Installer: Leave this manual with the appliance.

Consumer:Retain this manual for future reference.

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IFYOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

UNVENTED

GAS FIREPLACE

MODELS

VFP32FP(20,21)L(N,P)-1

VFP32FP(30,31)L(N,P)-1

VFP36FP(20,21)L(N,P)-1

VFP36FP(30,31)L(N,P)-1

This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

This is an unvented gas-firedheater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to page 7.

WARNING:Ifnotinstalled,operatedandmaintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

WATERVAPOR:ABY-PRODUCTOFUNVENTEDROOM HEATERS

Water vapor is a by-productof gas combustion. An unventedroomheaterproducesapproximatelyone(1) ounce(30ml)ofwaterforevery1,000BTU's(.3KW's) of gas input per hour. Refer to page 7.

Page 1

TABLE OF CONTENTS

 

SECTION

PAGE

Important Safety Information.................................................................................................

3

Safety Information for Users of LP Gas.................................................................................

4

Introduction............................................................................................................................

5

Specifications .........................................................................................................................

6

Water Vapor: A By-Productof Unvented Room Heaters.......................................................

7

Provisions for Adequate Combustion and Ventilation Air ................................................

7-8

Gas Supply .......................................................................................................................

9-10

Clearances ...........................................................................................................................

10

Combustible Materials .........................................................................................................

11

Fireplace Dimensions...........................................................................................................

12

Installing Hood and Trim Kit ...............................................................................................

13

Planning Installation.............................................................................................................

13

Fireplace Framing and Installation.......................................................................................

14

Placement of Glowing Embers and Lava Rock....................................................................

15

Operation Instructions/Flame Appearance...........................................................................

16

VFP(32,36)FP(30,31)L Lighting Instructions .....................................................................

17

VFP(32,36)FP(20,21)L Lighting Instructions .....................................................................

18

Pilot Flame Characteristics.............................................................................................

19-20

Wiring ..................................................................................................................................

20

Maintenance .........................................................................................................................

20

Troubleshooting..................................................................................................................

21

Parts List...............................................................................................................................

22

Parts View ............................................................................................................................

23

How To Order Repair Parts..................................................................................................

23

Optional Variable Speed Blower Installation Instructions .............................................

24-25

Junction Box Wiring Installation Instructions......................................................................

26

Optional Brick Liner Installation Instructions .....................................................................

26

Service Notes........................................................................................................................

27

Page 2

20101-3-0907

IMPORTANT SAFETY INFORMATION

An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom

An unvented room heater having an input rating of more than10,000Btuperhourshallnotbeinstalledinabedroom or bathroom.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Childrenandadultsshouldbealertedtothehazardofhigh surface temperature and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room with the appliance.

Do not place clothing or other flammable material on or near the appliance.

Installation and repairshould be done by a QUALIFIED SERVICE PERSON. This appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.

DO NOT use this room heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

You must operate heater with fireplace screen closed in place. Do not close glass doors while operating heater.

Do not place trash, logs or other articles on the log set during operation.

Duringmanufacturing,fabricatingandshipping,various components of this appliance are treated with certain oils, films or bonding agents. These bonding agents are not harmful but may produce annoying smoke and smells as they are burned off during initial operation of the appliance. This is a normal temporary occurrence. A window should be opened during the initial bake out period.

Correct installation of the ceramic fiber logs, proper locationoftheheaterandannualcleaningarenecessaryto avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace. See instructions forproper installation.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

WARNING!Thisfireplaceneedsfreshairforventilationto runproperly.ThisfireplacehasanODS(oxygendepletion sensor) which will shut down the heaterif adequate fresh air is not available. See troubleshooting section in the instructions.

Keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

WARNING

When used without adequate combustion and ventilation air,

 

CARBON MONOXIDE POISONING MAY LEAD TO

 

heater may give off CARBON MONOXIDE, an odorless, poi-

 

DEATH.

 

sonous gas.

Early signs of carbon monoxide poisoning resemble the flu,

 

Do not install heater until all necessary provisions are

 

with headache, dizziness and/or nausea. If you have these signs,

 

madeforcombustionandventilationair.Consultthewrit-

 

heater may not be working properly. Get fresh air at once!

 

ten instructions provided with the heaterforinformation

 

Have heater serviced.

 

concerningcombustionandventilationair.Intheabsence

 

Some people — pregnant women, persons with heart or lung

 

ofinstructions,refertotheNationalFuelGasCode,ANSI

 

disease, anemia, those under the influence of alcohol , those at

 

Z223.1, Section 5.3 or applicable local codes.

 

high altitudes — are more affected by carbon monoxide than

 

This heater is equipped with a PILOT LIGHT SAFETY SYS-

others.

TEM designed to turn off the heater if not enough fresh air

The pilot light safety system senses the depletion of oxygen at its

is available.

location. If this heater is installed in a structure having a high

 

 

 

vertical dimension, the possibility exists that the oxygen supply

 

DO NOT TAMPER WITH PILOT LIGHT SAFETY

 

 

 

atthehigherlevelswillbelessthanthatattheheater.Inthistype

 

SYSTEM!

 

 

 

of application, a fan to circulate the structure air will minimize

 

If heater shuts off, do not relight until you provide fresh air.

 

thiseffect.Theuseofthisfanwillalsoimprovethecomfortlevel

If heater keeps shutting off, have it serviced. Keep burner and

in the structure. When a fan is used to circulate air, it should be

control compartment clean.

located so that the air flow is not directed at the burner.

20101-3-0907

Page 3

SAFETY INFORMATION FOR USERS OF LP-GAS

Propane (LP-Gas)is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident. Read them carefully now, then review them point

bypointwiththemembersofyourhousehold.Somedaywhen theremaynotbeaminutetolose,everyone'ssafetywilldepend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

LP-GASWARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.That's your signal to go into immediate action!

Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.

Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.

Close all gas tank or cylinder supply valves.

LP-Gasis heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.

Use your neighbor's phone and call a trained LP-Gasservice person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do notre-enterthe building, vehicle, trailer, or area.

Finally,lettheservicemanandfirefighterscheckforescaped gas. Have them air out the area before you return. Properly trained LP-Gasservice people should repair the leak, then check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas.You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area mask the gas odor. People may not smell the gas odor or their minds are on something else. Thinking about smelling a gas odor can make it easier to smell.

TheodorantinLP-gasiscolorless,anditcanfadeundersomecircumstances.For example, if there is an underground leak, the movement of the gas through soil can filter the odorant. Odorants

in LP-Gasalso are subject to oxidation. This fading can occur if there is rust inside the storage tank or in iron gas pipes.

Theodorantinescapedgascanadsorborabsorbontoorintowalls, masonry and other materials and fabrics in a room. That will take some of the odorant out of the gas, reducing its odor intensity.

LP-Gasmay stratify in a closed area, and the odor intensity could vary at different levels. Since it is heavier than air, there may be more odor at lower levels.Always be sensitive to the slightest gas odor. If you detectany odor, treat it as a serious leak. Immediately go into action as instructed earlier.

SOME POINTS TO REMEMBER

Learn to recognize the odor of LP-gas.Your local LP-Gas Dealer can give you a "Scratch and Sniff" pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.

If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gassystem. If you are qualified, consciously think about the odor ofLP-Gasprior to and while lighting pilot lights or performing service or making adjustments.

Sometimes a basement or a closed-uphouse has a musty smell that can cover up theLP-Gasodor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak ofLP-Gas.

Odor fade, due to oxidation by rust or adsorption on walls of newcylindersandtanks,ispossible.Therefore,peopleshould be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed to set too

long before refilling. Cylinders and tanks which have been out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP-gas dealer. A periodic sniff test of the LP-gas is a good safety measure under any condition.

If, at any time, you do not smell the LP-Gasodorant and you thinkyoushould,assumeyouhavealeak.Thentakethesame immediateactionrecommendedabovefortheoccasionwhen you do detect the odorizedLP-Gas.

If you experience a complete "gas out," (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.

Page 4

20101-3-0907

INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installermusthaveownerfilloutandmailwarrantycardsupplied with unvented room heater.

3.Installer should show owner how to start and operate unvented room heater.

Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.

Improperinstallation oruse of the heatercan cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.

This series is design certified in accordance with American NationalStandardZ21.11.2 bytheCanadianStandardsAssociation Laboratories as an Unvented Room Heater and should be installed according to these instructions.

Any alteration of the original design, installed other than as shownintheseinstructionsorusewithatypeofgasnotshownon theratingplateistheresponsibilityofthepersonandcompany making the change.

VFP(32,36)FP(30,31)L Only 750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operateanadditionalone (1) totwo (2) minutesbeforeyou turnthe gas control knob from the PILOTposition to the ON position.This time period allows the millivolts (electrical energy) to build-upto a sufficient level allowing the gas control to operate properly.

Important

AllcorrespondenceshouldrefertocompleteModelNumber,Serial Number and type of gas.

Attention: During initial use of ceramic log you will detect an odorastheceramiclogiscured. Also,duringthecuringprocess the ceramic log will burn with a yellow flame.

Notice: Duringinitialfiringofthisunit,itspaintwillbakeout,and

smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.

Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fire-proofbase as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

Solid-fuelsshall not be burned in a masonry orUL 127 factorybuilt fireplace in which an unvented room heater is installed.

Qualified Installing Agency

Installationandreplacementofgaspiping,gasutilizationequipment or accessories and repair and servicing of equipment shall be performedonlybya qualifiedagency. Theterm"qualifiedagency" meansanyindividual,firm,corporationorcompanywhicheitherin person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-firedsupplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

In the Sate of Massachusetts, unvented propane and natural gas-firedspace heaters shall be prohibited in bedrooms and bathrooms.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 1430 Broadway, New York, N.Y. 10018.

High Altitudes

Foraltitudes/elevationsabove2,000feet(610m),ratingsshouldbe reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size.

WARNING: This appliance is equipped for (natural gas or propane) gas. Field conversion is not permitted.

20101-3-0907

Page 5

SPECIFICATIONS

Model

VFP32FP

VFP36FP

Input Maximum

32,000

36,000

Minimum

22,000

25,000

Minimum Firebox Opening

 

 

Height without standoff

32 3/4"

34 3/4"

Width

34”

39”

Depth

17 3/8"

17 3/8”

Gas Inlet

3/8”

3/8”

 

 

 

Accessories

 

 

EK-1

Embers Kit

 

PE-20

Platinum Embers

 

FBB4*

Variable Speed Automatic Blower

 

VPP32A

VFP32FP — Ceramic Aged Brick Liner

 

VPP36A

VFP36FP — Ceramic Aged Brick Liner

 

Accessories For VFP(32,36)FP(30,31) Only

 

 

FRBC

Battery Operated Remote Control

 

FRBTC

Battery Operated Remote Control w/Thermostat

FREC

Electric Remote Control

 

FWS

Wall Switch

 

TMV

Wall Thermostat, Millivolt - Reed Switch

 

TRW

Remote Wall Thermostat

 

*FBB4 is standard (installed) on VFP(32,36)FP(21,31)

Page 6

20101-3-0907

Water vapor is a by-productof gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour.

Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat applications, the water vapor does not create a problem. In most applications, the water vapor enhances the low humidity atmosphere experienced during cold weather.

This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air.

TheNationalFuelGasCode,ANSIZ223.1definesaconfinedspace asaspacewhosevolumeislessthan50cubicfeetper1,000Btuper hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm or less with openings gasketed or sealed, and

b.Weather-strippinghasbeenaddedonopenablewindowsanddoors, and

c.Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceilingjoints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

Ifyourhomemeetsallofthethreecriteriaabove,youmustprovide additional fresh air. See “Ventilation Air From Outdoors,” page 8.

Determining if You Have a Confined or Unconfined Space

Usethisworksheettodetermineifyouhaveaconfinedorunconfined space.

Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

The following steps will help insure that water vapor does not become a problem.

1.Besuretheheaterissizedproperlyfortheapplication,including ample combustion air and circulation air.

2.If high humidity is experienced, a dehumidifier may be used to help lower the water vapor content of the air.

3.Do not use an unvented room heater as the primary heat source.

1.Determine the volume of the space (length x width x height).

Length x Width x Height = cu. ft. (volume of space)

Example:Spacesize16ft.(length)x10ft.(width)x8ft.(ceiling height) = 1,280 cu. ft. (volume of space)

Ifadditionalventilationtoadjoiningroomissuppliedwithgrills or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to determine the maximum BTU/Hr the space can support.

(volume of space) ÷ 50 cu. ft. = (maximum BTU/Hr the space can support)

Example: 1,280 cu. ft. (volume of space) ÷ 50 cu. ft. = 25.6 or 25,600 (maximum BTU/Hr the space can support)

3. Add the BTU/Hr of all fuel burning appliances in the space.

Vent-freeheater

 

 

BTU/Hr

Gas water heater

 

 

BTU/Hr

Gas furnace

 

 

BTU/Hr

Vented gas heater

 

 

BTU/Hr

Gas fireplace logs

 

 

BTU/Hr

Other gas appliances*

+

 

BTU/Hr

Total

=

 

BTU/Hr

Example: Vented gas heater

 

20,000

BTU/Hr

Vent-freeheater

 

+ 18,000

BTU/Hr

Total

=

38,000

BTU/Hr

*Do not include direct-ventgas appliances. Direct vent draws combustion air from the outdoors and vents to the outdoors.

4.Compare the maximum BTU/Hr the space can support with the actual amount of BTU/Hr used.

BTU/Hr (maximum the space can support) BTU/Hr (actual amount of BTU/Hr used)

Example:

25,600 BTU/Hr (maximum the space can support)

38,000 BTU/Hr (actual amount of BTU/Hr used)

Warning:Iftheareainwhichtheheatermaybeoperatedissmaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilationairbyoneofthemethodsdescribedintheNationalFuel Gas Co P

20101-3-0907

Page 7

Nl estionp 5

orGapplic b e r o al Co

s.

/H

p

I

PROVISIONS FOR ADEQUATE COMBUSTION & VENTILATION AIR (continued)

The space in the above example is a confined space because the actualBTU/HrusedismorethanthemaximumBTU/HRthespace can support. You must provide additional fresh air. Your options are as follows:

A.Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventilation grills between rooms. See

Ventilation Air From Inside Building.

B.Vent room directly to the outdoors. See VentilationAir From

Outdoors.

C.Install a lower BTU/Hr heater, if lower BTU/Hr size makes room unconfined.

If the actual BTU/Hr used is less than the maximum BTU/Hr the space can support, the space is an unconfined space.You will need no additional fresh air ventilation.

WARNING: You must provide additional ventilation air in a confined space.

Ventilation Air Ventilation Air From Inside Building (Figure 1)

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 1). You can also remove door into adjoining room (see option 3, Figure 1). Each ventilation grill or opening shall have a minimum free area of one square inch per 1,000 BTUH of the total input rating of the gas equipment in the confined space.

Ventilation Air From Outdoors (Figure 2)

Provideextrafreshairbyusingventilationgrillsorducts.Youmust provide two permanent openings: one within 12" of the ceiling and one with 12" of the floor. Connect these items directly to the outdoorsorspacesopentotheoutdoors.Thesespacesincludeattics and crawl spaces. In most cases for direct communication with the outdoors or direct communication through a vertical duct a free area opening of one square inch per 4,000 BTU/Hr of heater input rating for each grill. If a horizontal duct is used, a grill free area or duct opening shall have a free area opening of one square inch per 2,000BTU/Hrforeachgrill.FollowtheNational Fuel Code NFPA 54/ANSI Z223.1, Section 5.3 Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has athermostat-controlledpower vent. Heated air entering the attic will activate the power vent.

Figure 2

Figure 1

WARNING: Rework worksheet, adding the space of the adjoiningunconfinedspace.Thecombinedspacesmusthave enough fresh air to supply all appliances in both spaces.

Page 8

20101-3-0907

GAS SUPPLY

Check all local codes for requirements, especially for the size and type of gas supply line required.

Recommended Gas Pipe Diameter

 

Pipe Length

Schedule 40 Pipe

Tubing, Type L

 

Inside Diameter

Outside Diameter

 

Nat.

L.P.

Nat.

L.P.

0-10feet

1/2”

3/8”

1/2”

3/8”

0-3meters

12.7mm

9.5mm

12.7mm

9.5mm

10-40feet

1/2”

1/2”

5/8”

1/2”

4-12meters

12.7mm

12.7mm

15.9mm

12.7mm

40-100feet

1/2”

1/2”

3/4”

1/2”

13-30meters

12.7mm

12.7mm

19mm

12.7mm

100-150feet

3/4”

1/2”

7/8”

3/4”

31-46meters

19mm

12.7mm

22.2mm

19mm

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks.Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

The use of the following gas connectors is recommended:

ANSZ21.24ApplianceConnectorsofCorrugatedMetalTubing and Fittings

ANS Z21.45 Assembled Flexible Appliance Connectors of Other Than All-MetalConstruction

The above connectors may be used if acceptable by the authority havingjurisdictionThestateofMassachusettsrequiresthataflexible appliance connector cannot exceed three feet in length.

Figure 3

20101-3-0907

Page 9

GAS SUPPLY (continued)

Checking Manifold Pressure

VFP(32,36)FP(30,31)LN (Natural gas) will have a manifold pressureofapproximately3.5"w.c.(.871kPa)formaximuminputor 1.7"w.c.(.423kPa)forminimuminputatthepressureregulatoroutlet with the inlet pressure to the pressure regulator from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.614kPa).VFP(32,36)FP(20,21)LN (Natural gas) will have a manifold pressure of approximately 6.0" w.c.(1.49kPa)atthepressureregulatoroutletwiththeinletpressure to the pressure regulator from a minimum of 7.0" w.c. (1.74kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa).VFP(32,36)FP(30,31)LP (Propane gas) will have a manifoldpressureapproximately10.0"w.c.(2.49kPa)formaximum input or 4.9"w.c. (1.220kPa) for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa).

VFP(32,36)FP(20,21)LP (Propane gas) will have a manifold pressure approximately 10.0"w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa).

Atest gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch (3mm) N.P.T. plugged tapping.

VFP(32,36)FP(30,31) Millivolt Control

The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “A” closest to control knob).After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal.Do not over torque. Check for gas leaks.

CLEARANCES

MinimumWallandCeilingClearances(Figure 4)

Sidewall Clearances:The clearance from the inside of the fireplace to any combustible wall should not be less than 2".

Fireplace Side and Back Clearances: The fireplace outer casing sides and back have zero clearance to combustibles.

Ceiling Clearances: The ceiling height should not be less than 36" from the top of the hood.

Mantel Clearances: Vent free fireplace models must use the hood supplied with the fireplace. If a combustible mantel is installed, it must meet the clearance requirements detailed above.

36”

2”

Mantel Clearances (Figure 5)

12”10”

MANTEL

COMBUSTIBLES

ALLOWED 8”

6”

18” 4”

15 1/4”

12 ½”

2”

 

9 3/4”

7”

4 1/4”

HOOD

Figure 5

Figure 4

Page 10

20101-3-0907