INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL

The White Mountain Log Collection:

ROCK CREEK

LOG SET FOR

VENTED AND UNVENTED MULTI-SIDEDGAS LOG HEATER

MODELS

LSU18RR-1

LSU24RR-1

LSU30RR-1

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IFYOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installer: Leave this manual with the appliance.

Consumer:Retain this manual for future reference.

Log sets comply with ANSI Z21.11.2 Unvented Heaters and also comply with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allowoperationoflogsetsinaventedconfiguration. Check your state or local codes.

WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

Page 1

TABLE OF CONTENTS

 

Section

Page

Important Installation Guidelines.........................................................................

3

General Information.............................................................................................

3

Log Placement...................................................................................................

4-6

LSU18RR-1Photos..............................................................................................

7

LSU24RR-1Photos..............................................................................................

8

LSU30RR-1Photos..............................................................................................

9

Parts List & Parts View......................................................................................

10

How to Order Repair Parts.................................................................................

11

Notes ..................................................................................................................

11

Page 2

23370-1-1107

IMPORTANT INSTALLATION GUIDELINES

Proper Log Placement

Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set. Owners need to be shown proper log placement and instructed not to move the logs.

Logs must fit firmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.

Proper Placement of Rock Wool and Decorative Lava Rock

Rock wool can be added to burners for a glowing ember effect. It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool.

Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox.

Proper Primary Airflow into Burner

For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructionsbuild-uparoundorinsidetheventuri.Anyobstructionin the venturi tube area must be removed. The flow of air into the venturiisalsoreducedifthegasorificeisn’tcenteredintheventuri inletand/orisnotalignedwiththeventuri.Anymisalignmentofthe burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.

Ceiling Fans, Portable Fans or Logs Installed Near Cold Air Returns

Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-freelogs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around avent-freelog set can cause the flame to impinge on the log and create a sooting situation.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

Candles

Avoidtheuseofscentedordecorativecandleswhilethelogsetisin operation.Candlesproducearesidueintheairthatcreatesasootlike substance.Burningcandleswhilethelogsetisoperatingmagnifies the problem. It should be noted that candles, in general, produce soot.Theamountoftimeburnedandthequantityofcandlesburned will determine the amount of soot produced and deposited.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service. Do not continue to operate the log set.

Sunken Fireplace

If installing this unit into a sunken fireplace, you must raise the floor to insure adequate airflow and guard against sooting. Raise fireplace floor using a non-combustiblematerial, which is secure.

Glass Doors

Make sure that glass doors are open during all operations of the logset.Theopeningoftheglassdoorframeshouldbethedimension used for the minimum front opening of the firebox.

Woodburning Fireplaces

The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the logset causing odors and possibly sooting.

WARNING:Beforeinstallinginasolid-fuelburningfireplace,thechimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

GENERAL INFORMATION

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency.The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for(a)theinstallation,testing,orreplacementofgaspipingor(b)the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA54.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10018.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-firedsupplemental room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-firedspace heaters shall be prohibited in bedrooms and bathrooms.

23370-1-1107

Page 3

LOG PLACEMENT

Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water.

All Logs

The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance.

Refer to Figure 1 for the following warning.

Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

PROPER INSTALLATION SEQUENCE:

ATTENTION: For the instructions below, "Front" indicates the side of the burner with the valve.

1.With the valve "front" side facing you, place Back Right Log (log A) onto right back pins of burner.

2.Place Right Middle Log (log B) onto right middle pins of burner.

3.Place Left Back Log (log C) onto left back pins of burner.

4.Place Left Middle Log (log D) onto left middle pins of burner.

5.Place Right Front Log (log E) onto right front pin of burner.

6.Place Center Middle Log (log F) onto burner top against logs B and D. Note: Omit this step for 18" log sets.

7.Place Left Front Log (log G) onto left front pins of burner.

Figure 1

Page 4

23370-1-1107

LOG PLACEMENT

8.Insert boss of Middle Bottom Branch (log H) onto recess on logs E, B, and C.

9.Insert boss of Middle Top Branch (log I) onto recess on log H (Center Branch) and logs A and B. Note: Omit this step for 18" log sets.

10.Insert boss of Top Left Branch (log K) into recess of logs C, D, and G).

11.Insert recess of Top Right Branch (log L) to the recess of log A.

Figure 2

12.Compare the completed log installation with the appropriate photo from pages 4 to 6. Review previous steps to make any necessary adjustments.

13.Log placement is complete.

23370-1-1107

Page 5

LOG PLACEMENT

Apply loose material (glowing embers) per appropriate Installation Instructions and Owner's Manual. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater. WARNING: All previously applied loose material must be removed prior to reapplication.

Replacement Loose Material (glowing embers) Part Number

LSU18RR-1

15970

LSU24RR-1

15970

LSU30RR-1

15970

Platinum Bright Embers

PE-20-1

Note: A single layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with production embers) to the burner.

I

K

L

H

A

C

B

F

D

E

G

Log Placement

LS(18,24,30)RR-1Logs

Figure 3

Attention: Do not use Figures 1 to 3 to order replacement logs. Refer to Page 10, Parts List and Parts View to order logs for your appropriate model number.

The following WARNING applies when log set is installed onto an unvented gas burner assembly.

WARNING: This appliance is equipped for (natural or propane) gas. Field conversion is not permitted.

Page 6

23370-1-1107

EMBER PLACEMENT LSU18RR-1PHOTOS

Rear View

Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers)

 

 

 

 

 

Top View

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front View (Valve Side)

23370-1-1107

Page 7

EMBER PLACEMENT LSU24RR-1PHOTOS

Rear View

Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers)

 

 

 

 

Top View

 

 

 

 

 

 

 

 

 

 

 

 

 

Front View (Valve Side)

Page 8

23370-1-1107

EMBER PLACEMENT LSU30RR-1PHOTOS

Rear View

Some logs have been removed for clarity Do not cover any large ports with loose material (glowing embers)

 

 

 

 

Top View

 

 

 

 

 

 

 

 

 

 

 

 

 

Front View (Valve Side)

23370-1-1107

Page 9

PARTS LIST & PARTS VIEW

Attention: When ordering parts, it is very important thatpart number anddescription of part coincide.

I

K

L

H

A

C

B

F

D

E

G

Index No.

Part Number

Part Number

Part Number

 

 

LSU18RR-1

LSU24RR-1

LSU30RR-1

Description

A

R9312

R9323

R9329

BACK RIGHT LOG

B

R9313

R9324

R9330

RIGHT MIDDLE LOG

C

R9314

R9325

R9331

LEFT BACK LOG

D

R9315

R9326

R9332

LEFT MIDDLE LOG

E

R9316

R9327

R9333

RIGHT FRONT LOG

F

N/A

R9328

R9334

CENTER MIDDLE LOG

G

R9317

R9366

R9367

LEFT FRONT LOG

H

R9320

R9462

R9318

MIDDLE BOTTOM BRANCH

I

N/A

R9319

R9319

MIDDLE TOP BRANCH

K

R9321

R9321

R9321

TOP LEFT BRANCH

L

R9322

R9322

R9322

TOP RIGHT BRANCH

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OFANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

Page 10

23370-1-1107