Empire Comfort Systems DVP42FP3, DVP48FP9, DVP48FP3, DVP42FP7, DVP48FP7 User Manual

...
0 (0)

INSTALLATION INSTRUCTIONS

AND

OWNER’S MANUAL

The Tahoe Direct Vent Zero Clearance

Gas Fireplace Heater

DIRECT VENT

GAS FIREPLACE HEATER

WARNING:Iftheinformationinthismanual isnotfollowedexactly,afireorexplosionmay result causing property damage, personal injury or loss of life.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbors phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

MODEL SERIES

DVP42FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT) DVP48FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT)

DVP42FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT) DVP48FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT)

DVP42FP9(0,1,2,3)(N,P)-1 (REMOTE RF MODELS) DVP48FP9(0,1,2,3)(N,P)-1 (REMOTE RF MODELS))

GAS-FIRED

EFFECTIVE DATE

JULY 2005

UL FILE NO. MH30033

Thisappliancemaybeinstalledinanaftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by state or local codes.

This appliance is only foruse with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING: If not installed, operated and maintained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel orfrom fuel combustion which can cause death or serious illness.

17375-6-0705

Page 1

TABLE OF CONTENTS

 

Section

Page

Important Safety Information.........................................................................................................

3

Safety Information for Users of LP Gas........................................................................................

4

Introduction ....................................................................................................................................

5

Specifications .................................................................................................................................

6

Fireplace Dimensions.....................................................................................................................

6

Clearances.......................................................................................................................................

7

Locating Fireplace..........................................................................................................................

7

Gas Supply......................................................................................................................................

8

Rear Vent Conversion/Vent Systems............................................................................................

9

Installation ...............................................................................................................................

10-13

Venting Fireplace-Top Vent.....................................................................................................

14-17

Venting Fireplace-Rear Vent ...................................................................................................

18-19

Termination Clearances ...............................................................................................................

20

Vent Clearances............................................................................................................................

21

Vent System Identification...........................................................................................................

22

Framing and Finishing ............................................................................................................

23-24

Horizontal Termination.................................................................................................................

24

DVVK-5F Flex Vent........................................................................................................................

25

Vertical Termination ................................................................................................................

26-27

Log Placement .............................................................................................................................

28

Operating Instructions ............................................................................................................

29-30

Wiring Diagram-Standing Pilot....................................................................................................

31

Lighting Instructions-Standing Pilot...........................................................................................

32

Troubleshooting-Standing Pilot ..................................................................................................

33

Intermittent Pilot Operating Instructions....................................................................................

34

Intermittent Pilot Wiring Instructions .........................................................................................

34

Intermittent Pilot Lighting Instruction ........................................................................................

35

Intermittent Pilot Troubleshooting.........................................................................................

36-39

RF Standing Pilot Operating Instructions ..................................................................................

40

RF Transmitter Functions ............................................................................................................

41

RF Wiring Diagram .......................................................................................................................

42

RF Standing Pilot Lighting Instructions.....................................................................................

43

Maintenance and Service.............................................................................................................

44

Parts View......................................................................................................................................

45

Parts List .......................................................................................................................................

46

FBB4 Optional Variable Speed Blower Installation ..............................................................

47-48

Junction Box Wiring Installation Instruction .............................................................................

49

Optional Brick Liner Installation Instruction..............................................................................

49

Accessories...................................................................................................................................

50

How To Order Repair Parts..........................................................................................................

51

Service Notes................................................................................................................................

51

Page 2

17375-6-0705

IMPORTANT SAFETY INFORMATION

Beforeenclosingtheventpipeassembly,operatetheappliancetoensureitisventingproperly.

DO NOT OPERATE THISAPPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED

If this appliance is installed directly on carpeting,

placed on or near the appliance.

 

tile or other combustible material other than wood

• Adequate accessibility clearances for servicing and

 

flooring the appliance shall be installed on a metal or

proper operation.

 

wood panel extending the full width and depth of the

 

• This appliance must not share or be connected to a

 

appliance.

 

Thebasereferredtoabovedoesnotmeanthefireproof

flue serving a separate solid-fuel burning appliance.

 

• Keep the area around your appliance clear of

 

baseasusedonwoodstoves.Theprotectionisforrugs

 

that are extremely thick and light colored tile.

combustiblematerials,gasolineandotherflammable

Children and adults should be alerted to the hazards

vapor and liquids.

• Undernocircumstancesshouldanysolidfuels(wood,

 

of high surface temperatures and should stay away

 

to avoid burns or clothing ignition.

coal, paper or cardboard etc.) be used in this appli-

Young children should be carefully supervised when

ance.

• The flow of combustion and ventilation air must not

 

they are in the same room as the appliance.

Clothing or other flammable material should not be

be obstructed in any way.

 

 

 

 

Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.

The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance. Work should be done by a qualified service person.

Keep burner and control compartment clean.

Vent cap is hot while fireplace is in operation.

Installation and repair should be done by a QUALIFIED SERVICE PERSON. The appliance shouldbeinspectedbeforeuseandatleastannually by a qualified service person. More frequent cleaningmayberequiredduetoexcessivelintfrom carpeting, bedding materials, etc. It is imperative thatcontrolcompartments,burnersandcirculating air passageways of the appliance be kept clean.

DO NOT put anything around the fireplace that will obstruct the flow of ventilation air.

Clearance in accordance with local installation codes and the requirements of the gas supplier.

DO keep the appliance area clear and free from combustiblematerial,gasolineandotherflammable vapors and liquids.

DOexamineventingsystemperiodicallyandreplace damaged parts.

DOmakeaperiodicvisualcheckofpilotandburners. Clean and replace damaged parts.

CAUTION: The glass used in your fireplace is temperedglass.Iftheglassiscrackedordamagedin anyway,itshouldbereplacedonlywithacomplete glass frame assembly from Empire. See parts list on Page 40 for ordering.

DO NOT use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any partofthecontrolsystemandanygascontrolwhich has been under water.

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.

17375-6-0705

Page 3

SAFETY INFORMATION FOR USERS OF LP GAS

Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless.Youmaynotknowallthefollowingsafetyprecautions which can protect both you and your family from an accident. Read them carefully now, then review them point

by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do. If, after reading the following information, you feel you still need more information, please contact your gas supplier.

LP-GAS WARNING ODOR

If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas. That’s your signal to go into immediate action!

Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.

Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.

Close all gas tank or cylinder supply valves.

LP-Gas is heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.

Useyourneighbor’sphoneandcallatrainedLP-Gasservice person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area.

Finally,lettheservicemanandfirefighterscheckforescaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.

NO ODOR DETECTED - ODOR FADE

Somepeoplecannotsmellwell.Somepeoplecannotsmellthe odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area mask the gas odor. People may not smell the gas odor or their minds are on something else. Thinking about smelling a gas odor can make it easier to smell.

TheodorantinLP-gasiscolorless,anditcanfadeundersome circumstances.Forexample,ifthereisanundergroundleak,the movementofthegasthroughsoilcanfiltertheodorant.Odorants inLP-Gasalsoaresubjecttooxidation.Thisfadingcanoccurif

there is rust inside the storage tank or in iron gas pipes.

The odorant in escaped gas can adsorb or absorb onto or into walls, masonry and other materials and fabrics in a room. That will take some of the odorant out of the gas, reducing its odor intensity.

LP-Gas may stratify in a closed area, and the odor intensity could vary at different levels. Since it is heavier than air, there may be more odor at lower levels. Always be sensitive to the slightest gas odor. If you detect any odor, treat it as a serious leak. Immediately go into action as instructed earlier.

SOME POINTS TO REMEMBER

LearntorecognizetheodorofLP-gas.Your local LP-Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.

If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.

Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.

Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed

to set too long before refilling. Cylinders and tanks which havebeenoutofserviceforatimemaydevelopinternalrust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any question about the gas odor, call your LP-gas dealer.Aperiodic sniff test of the LP-gas is a good safety measure under any condition.

If,atanytime,youdonotsmelltheLP-Gasodorantandyou thinkyoushould,assumeyouhavealeak.Thentakethesame immediateactionrecommendedabovefortheoccasionwhen you do detect the odorized LP-Gas.

If you experience a complete “gas out,” (the container is undernovaporpressure),turnthetankvalveoffimmediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs,somenewinternalrustingcouldoccur.Ifthevalveis left open, then treat the container as a new tank.Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.

Page 4

17375-6-0705

INTRODUCTION

Instructions to Installer

1.Installer must leave instruction manual with owner after installation.

2.Installer must have owner fill out and mail warranty card supplied with the fireplace.

3.Installer should show owner how to start and operate the fireplace.

Thisdirectventgasfireplaceheaterisdesignedtooperatewithall combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building. The information contained in this manual pertains to all models and gas control systems unless otherwise noted.

Warning: This unit is not for use with solid fuels.

Appliance Certification

This fireplace is design certified in accordance with American NationalStandard/CSAStandardANSIZ.21-88/CSA2.33andby Underwriters Laboratories as a Direct Vent Gas Fireplace Heater and shall be installed according to these instructions.

Consult your local building code agency, prior to installation, to ensure compliance with local codes-including permits and inspections.

The fireplace, when installed, must be electrically grounded in accordance with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA 70 or Canadian Electric code, CSAC22.1, if an external electrical source is utilized.

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

Qualified InstallingAgency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shallbeperformedonlybyaqualifiedagency.Theterm“qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Theinstallationmustconformwithlocalcodesor,intheabsenceof localcodes,withtheNational Fuel Gas CodeANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, or CSA B149.1

in Canada. *Available from the American National Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.

Warning:ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS.

Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.

Important

All correspondence should refer to complete Model Number, Serial Number and type of gas.

HighAltitude

When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification.

Canadian HighAltitude

Altitude: 0-4500 feet (0-1370 m)

When installing this unit at an elevation above 4500 feet (in Canada), check with local authorities.

Consult your local gas utility for assistance in determining the proper orifice for location.

Preparation

Thisdirectventgasfireplaceanditscomponentsaretestedandsafe wheninstalledinaccordancewiththisInstallationManual.Report to your dealer any parts damaged in shipment, specifically check glass condition. Do not install unit with damaged, incomplete, or substitute parts. Read all instructions before starting installation andfollowtheseinstructionscarefullyduringinstallationtoinsure maximumbenefitandsafety.Failuretofollowthemwillvoidyour warranty and may present a fire hazard.

The warranty will be voided by, and the warranter disclaims any responsibility for the following actions:

Installation of any damaged fireplace or vent system component.

Modification of the fireplace or direct vent system.

InstallationotherthanasinstructedbyEmpireComfortSystems, Inc.

Improper positioning of the logs, glass door or decorative rock.

Installationand/oruseofanycomponentpartnotmanufactured or approved by manufacturer.

17375-6-0705

Page 5

Empire Comfort Systems DVP42FP3, DVP48FP9, DVP48FP3, DVP42FP7, DVP48FP7 User Manual

SPECIFICATIONS

 

 

DVP42

DVP48

 

 

 

 

Input Btu/hr Maximum

28,000

30,000

 

 

 

 

Btu/hr Minimum (millivolt only)

19,000

20,500

 

 

 

 

KWH (Maximum)

8.2

8.8

 

 

 

 

(Minimum)

5.5

6.0

 

NOTE:Air shutter settings

 

NAT.

 

 

 

 

 

 

 

are factory minimum settings.

 

Orifice

#38 (.1015)

#37 (.1040)

 

 

 

Some venting configurations

 

P-203

P-213

 

 

Air Shutter Opening

1/8"(3.2mm)

1/8"(3.2mm)

 

may require minor air shutter

 

LP

 

 

 

adjustments for optimum

 

Orifice

#52 (.0635")

1.65MM

 

performance.

 

P-213

P-250

 

 

 

 

 

 

 

 

 

Air Shutter Opening

FULL OPEN

FULL OPEN

 

 

 

 

Height without standoff

343/4"(3.2mm)

34 3/4"(3.2mm)

 

 

 

Width

43"(1092mm)

49"(1245mm)

 

 

 

 

Depth

19

19 7/8"(505mm)

 

 

 

7/8"(505mm)

 

 

 

 

 

 

 

 

 

Gas Inlet Shutoff Valve (Pipe)

1/2 NPT

1/2 NPT

 

 

 

Venting Options

Description

Remote Control Options &

 

 

Description

DVVK-5TS

TOP VENT KIT (HORZ.) - 4½" TO 6" WALL

 

 

 

THICKNESS (114.3mm to 152mm)

Accessories

 

 

 

DVVK-5T

TOP VENT KIT (HORZ.) - 8" TO 12" WALL

FRBC

MILLIVOLT BATT. REMOTE ON/OFF

 

THICKNESS (203mm to 305mm)

FRBTC

MILLIVOLT BATT. REMOTE T-STAT

DVVK-5R

REAR VENT KIT (HORZ.) - 5" TO 7" WALL

TMW

MILLIVOLT WIRELESS WALL THERMOSTAT

 

THICKNESS (203mm to 305mm)

TRW

MILLIVOLT REED SWITCH WALL THERMOSTAT

DVVK-5V

VERTICAL VENT KIT

FWS-1

DIRECT IGNITION/MILLIVOLT WALL SWITCH

DVVK-5F

HORIZONTAL FLEX VENT KIT (4' FLEX)

 

 

 

 

 

 

(1.22M)

 

 

 

 

 

 

FIREPLACE DIMENSIONS

 

 

 

 

RIGHT SIDE VIEW

 

 

DVP42

DVP48

 

 

 

 

 

 

 

 

 

A

43"

49"

 

 

 

 

 

1092mm

1245mm

 

 

 

 

B

40"

46"

 

 

 

 

 

1016mm

1168mm

 

 

 

 

C

25 1/16"

25 1/16"

 

 

 

 

 

636 mm

636 mm

 

 

 

 

D

37 5/8"

37 5/8"

 

 

 

 

 

956 mm

956 mm

 

 

 

 

E

34 3/4"

34 3/4"

 

 

 

 

 

883 mm

883 mm

 

 

 

 

F

19 7/8"

19 7/8"

 

 

 

 

 

505 mm

505 mm

 

 

 

 

G

26"

26"

 

J

 

 

 

660 mm

660 mm

 

 

 

H

7 1/8"

7 1/8"

 

H

 

 

 

 

 

 

181 mm

181 mm

 

 

K

 

I

26 1/2"

32 1/2"

 

 

 

 

826 mm

826 mm

 

 

 

 

 

 

 

 

 

J

13 1/4"

16 1/4"

 

 

 

 

 

337 mm

413 mm

 

 

 

 

K

12 3/4"

12 3/4"

 

 

 

 

 

324 mm

324 mm

Page 6

Figure 1

17375-6-0705

CLEARANCES

Clearance to Combustibles

Back

0" (0 mm)

Side

0" (0 mm)

Floor

0" (0 mm)

Top Stand-off

0" (0 mm)

Top Framing Edge

3" (76 mm)

SEE MANTLE CHART FOR

MAXIMUM MANTLE DEPTH

SEE MANTLE CHART FOR MINIMUM HEIGHT OF MANTLE ABOVE UNIT

FINISHED WALL (COMBUSTIBLE)

NON-COMBUSTIBLE

FIRST 3(SEE MAGNIFIED VIEW)

TOP FRAMING

LEDGE

GLASS FRONT

2" x 4" HEADER

STAND OFF 3" (76 mm) HEIGHT ABOVE TOP OF FIREPLACE

3"

NAILING

FLANGES

Figure 3

Clearances (Figure 4)

Clearance from top front edge of fireplace to ceiling is 36" Clearance from side of fireplace to adjacent sidewall is 6".

(914mm)

Figure 2

Combustible Material

Nogreetingcards,stockingsorornamentationofanytypeshould be placed on or attached to the fireplace. The flow of heat can ignite combustibles.

Figure 4

LOCATING FIREPLACE

Note: Island(C)andRoomDivider

(D) installation is possible as long as the horizontal portion of the vent system (H) does not exceed 20 feet with a minimum vertical runof8feet.SeedetailsinVenting Section.

When you install your DirectVent Fireplace in (D) Room divider or

(E) Flat on wall corner positions, a minimum of 6 inches clearance must be maintained from the perpendicular wall and the front edge of the appliance.

CORNER

CABINET

INSTALLATION

INSTALLATION

ISLAND

FLUSH WALL

INSTALLATION

INSTALLATION

ANGLED CORNER

 

INSTALLATION

ROOM DIVIDER

 

INSTALLATION

Figure 5

17375-6-0705

Page 7

GAS SUPPLY

The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.

Recommended Gas Pipe Diameter

Pipe Length

Schedule 40 Pipe

Tubing, Type L

(Feet)

Inside Diameter

Outside Diameter

 

 

 

 

 

 

Nat.

L.P.

Nat.

L.P.

 

 

 

 

 

0-10

1/2"

3/8"

1/2"

3/8"

 

12.7mm

9.5mm

12.7mm

9.5mm

 

 

 

 

 

11-40

1/2"

1/2"

5/8"

1/2"

 

12.7mm

12.7mm

15.9mm

12.7mm

 

 

 

 

 

41-100

1/2"

1/2"

3/4"

1/2"

 

12.7mm

12.7mm

19mm

12.7mm

 

 

 

 

 

101-150

3/4"

1/2"

7/8"

3/4"

 

19mm

12.7mm

22.2mm

1.9 mm

 

 

 

 

 

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

The use of the following gas connectors is recommended:

ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing and Fittings.

ANS Z21.45 Assembled Flexible Appliance Connectors of Other ThanAll-Metal Construction

The above connectors may be used if acceptable by the authority having jurisdiction. The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

 

 

Figure 6

 

 

 

 

 

 

Gas Supply Pressure (inches w.c.)

 

 

 

 

 

 

Minimum

Normal

 

Maximum

 

 

 

 

 

Natural Gas

4.5"

7.0"

 

*14.0"

 

 

 

 

 

LP (Propane)

10.8"

11.0"

 

*14.0"

 

 

 

 

 

Manifold Pressure (inches w.c.)

 

 

 

 

 

 

Normal (HI)

 

 

 

 

 

 

Natural Gas

 

3.5"

 

 

 

 

 

 

 

LP (Propane)

 

10.0"

 

 

*NOTE: Remote "RF" Models - 10.5" w.c. maximum

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

In the state of Massachusetts the gas cock must be a T handle type.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.

Compoundsusedonthreadedjointsofgaspipingshallberesistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Neveruse an exposed flame to check forleaks.Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

NOTE: The millivolt gas controls are equipped with a captured screwtypepressuretestpoint,thereforeitisnotnecessarytoprovide a 1/8" test point up stream of the control.

Ondirectignitionvalves,hexplugsmaybereplacedwithhosefittings for pressure checks, then reinstalled before operating fireplace.

When using copper or flex connector use only approved fittings.

Theapplianceandit’sindividualshutoffvalvemustbedisconnected fromsupplypipingsystemduringanypressuretestingofthatsystem at test pressures in excess of 1/2 psig (3.5kPa).

The appliance must be isolated from the gas supply piping system byclosingitsindividualmanualshutoffvalveduringanypressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).

Attention! If one of the procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a hazardous condition.

Checking Manifold Pressures

Both Propane and Natural gas valves have a built-in pressure regulatorinthegasvalve.Naturalgasmodelswillhaveamanifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa). Propane gas models will have a manifold

pressureapproximately10.0"w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 11.0" w.c.

(2.739kPa)forthepurposeofinput adjustmenttoamaximumof13.0" w.c. (3.237kPa).

Figure 7

Page 8

17375-6-0705

REAR VENT CONVERSION

VERTICAL VENTING

Note: It is recommended that the flue cover plate tab be pulled outward prior to removal.

This will ensure that the plate is not accidentally dropped inside the rear air chamber.

FLUE COVER PLATE

(See note above)

INLET VENT COVER PLATE

Note: Discard insulation

& retainer when venting off top of fireplace.

Note: Discard insulation & retainer when using vertical venting off

INLET VENT COLLAR

FLUE OUTLET

COLLAR

HORIZONTAL VENTING

INLET VENT

COVER PLATE

FLUE COVER PLATE

FLUE INSULATION

INSULATION

RETAINER

INLET VENT COLLAR

Converting flue take-off to rear venting

When switching out the flue and inlet vent collars to run horizontally off the rear vent, the following steps must be taken.

1.Remove the inlet vent collar (8 screws) and flue collar (4 screws) from the top of the fireplace, and set to the side.

2.Remove the inlet cover plate and flue cover plate located on the back of the fireplace. These will be used to close the top flue and inlet openings.

3.Insert the insulation retainer bracket and insulation into the top flue pipe before reinstalling the flue cover plate over the

top flue with 4 screws.

4.Reinstall the inlet cover plate over the top inlet opening with 4 screws. See illustration above..

5.Install the flue collar assembly to the rear flue with 4 screws.

6.Install the inlet vent collar to the rear of the fireplace with 8 screws.

7.This completes the conversion for a rear vent application.

Note: for top vented installations, the insulation and retainer are to be removed from the flue pipe and discarded.

VENT SYSTEMS

The following vent systems are acceptable for use with the DVP series fireplaces:

Simpson Duravent® GS 5" - 8"

American Metal Products 5" - 8"

Selkirk Direct-Temp® 5" - 8"

Empire Flexvent Kit(s) (Magnaflex) 5" - 8"

17375-6-0705

Page 9

INSTALLATION

Framing and Finishing

1.Choose unit location.

2.Frameinfireplacewithaheaderacrossthetop.Itisimportant to allow for finished face when setting the depth of the frame.

3.Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable to 1/2", 5/8" or 3/4" depths).

4. Use(8)1/2"hex-headscrewssuppliedinhardwarepackage, to screw through slotted holes in drywall strip and then screwintopre-drilledholesonfireplaceside.Measurefrom face of fireplace to face of drywall strip to determine final depth.

Vent Pipe Clearance

Note: Maintain one inch (1") of clearance around vertical vent pipe. See Fig. 9A. For horizontal vent, maintain a minimum 1" clearance to the bottom and sides of the vent, and 3" clearance to combustibles above the vent pipe. See Fig. 9B

Top of Vent

 

Combustibles NOT

 

allowed in shaded

3"(76 mm)

area

 

 

5” Diameter flue

 

8” Diameter

 

intake vent

1"(25 mm)

1"

(25 mm)

Figure 9B

Figure 8

VENT PIPE

1" MINIMUM CLEARANCE AROUND VENT PIPE

Figure 9A

Page 10

17375-6-0705

INSTALLATION (continued)

Note: For finishing to top of fireplace, refer to Figure 12.

Flush Mount Mantel Installation (Figure 10)

Thefireplacemustextend3/4"beyondfinishedwallsurfacewhen using a flush mount mantel. Refer to Figure 10 to locate nailing flanges on fireplace sides. Mark and drill two (2) 1/8" holes into fireplace side to mount each nailing flange. Use eight (8) 1/2" hex-head screws supplied in hardware package to attach nailing flanges to fireplace sides.

NAIL OR OTHER SUITABLE FASTENER

Figure 10

Framing (Figure 11)

Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall covering and fireplace facing material. The fireplace framing should be constructed of 2 x 4 lumber or heavier. The framing headersmayrestonthefireplacestandoffs.RefertoFigure11for minimum framing dimensions.

CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFYFRAMING METHODS,AND WALLCOVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS.

Framingdimension"A"includesathreeinchclearance for standoffs on firebox. After installing firebox into framing,thefinishedwallsurfacemustcoverthethree inch opening above the firebox.

 

DVP42

DVP48

"A"

37 3/4"

37 3/4"

"B"

43 3/8"

49 3/8"

"C"

19 7/8"

19 7/8"

Figure 11

Attention: If a base or mantel is not used and the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, it shall be installed on a metal or wood panel extending the full width and depth of the appliance. The vertical dimension in Figure 11 must be adjusted when a metal or wood panel is placed beneath the appliance.

Finishing (Figures 12 and 13)

Finish the walls with the material of your choice. Figure 3 on page7 showstheminimumverticalandcorrespondingmaximum horizontaldimensionsofmantelsorothercombustibleprojections above the top front edge of the fireplace.

Only non-combustible materials may be used to cover the black fireplace front.

Warning: When finishing the fireplace never obstruct or modify the air inlet/outlet louvers in any manner. Provide adequate clearances around air openings into the combustion chamber.

Caution: If the joints between the finished wall and the fireplace surround (top and sides) are sealed, a 300°F minimum sealant material must be used. These joints are not required to be sealed. Only non-combustible material (using 300°F minimum adhesive if needed), can be applied as facing to the fireplace surround.

17375-6-0705

Page 11

Flush Wall Installation

FINISHED WALL

3! OF NON-COMBUSTIBLE MATERIAL

FRONT TRIM OR NONCOMBUSTIBLE MATERIAL (INSTALLATION IS OPTIONAL)

JOINT BETWEEN FINISHED

WALL AND UNIT SEALED

WITH 300° F, 149° C SEALANT

MATERIAL (SEALANT IS OPTIONAL)

Figure 12

Combustible Surround Installation

Attention:Coldclimateinstallationrecommendation:

When installing this unit against a non-insulated exterior wall, it is mandatory that the outer walls be insulatedtoconformtoapplicableinsulationcodes.

Vent Runs (Figures 14, 15, 16, 17 and 18)

In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed. These include the direct vent system, gas piping for the appliance and the electrical wiring. (If the fan option is used.)

The appliance can be mounted on any of the following surfaces:

1.Aflat, hard combustible (burnable) surface.

2.Araised wooden platform.

3.Four(4)cornersupports.(Example:Four(4)concretemasonry blocks.) These supports must be positioned so they contact all four (4) perimeter edges on the bottom of the unit.

VERTICAL, 90° ELBOW WITH HORIZONTAL

TERMINATION

2 X 4 HEADER

STAND OFF

MANTELSHELF

COMBUSTIBLE SURROUND

FINISHED WALL

3! OF NON-COMBUSTIBLE MATERIAL

FRONT TRIM OR NON-COMBUSTIBLE MATERIAL (INSTALLATION IS OPTIONAL)

JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F 149° C

SEALANT MATERIAL (SEALANT IS OPTIONAL)

DVP42, 48 49 ½”(126 mm) TO BOTTOM

OF UNIT

VENT CAP/

THIMBLE

/ THIMBLE

Figure 14

Figure 13

Page 12

17375-6-0705

INSTALLATION (continued)

HORIZONTALONLY, STRAIGHT OUT THE BACK

CORNER INSTALLATION VERTICAL, 90° ELBOW TO

"A"

HORIZONTALOUT THE WALL

 

PIPE LENGTH

 

 

WALL FIRESTOP/

 

THIMBLE

VENT

CAP

VENT CAP

WALL FIRESTOP/

THIMBLE

"A"

"B"

MODEL

 

 

 

 

6"(152mm)

5 1/8"(130mm) to 6 /2"(165mm)

DVP 42,48

 

Dim.

DVP42

DVP48

9"(229mm)

8 1/8"(206mm) to 91/2"(241mm)

DVP 42

 

A

45 3/8"

49 5/8"

 

 

 

 

1152mm

1260mm

12"(305mm)

11 1/8"(283mm) to 12 1/2"(317mm)

DVP 42

 

 

 

B

32 1/8"

35 1/8"

 

 

 

 

 

 

 

 

816mm

892mm

 

Figure 15

 

 

 

 

 

 

 

 

 

 

 

 

C

13 3/8"

15 1/2"

 

 

 

 

34 mm

39 mm

 

 

 

 

 

 

 

 

 

D

64 1/8"

70 1/8"

 

VERTICAL, 90° ELBOW TO

 

 

1628mm

1781mm

 

 

 

 

 

 

 

 

Figure 17

 

HORIZONTALOUT THE WALL

 

 

CORNER INSTALLATION HORIZONTAL, 45° ELBOW

TO HORIZONTALOUT THE WALL

WALL FIRESTOP/

THIMBLE

WALL FIRESTOP/

THIMBLE

"A"

 

"B"

 

 

"C"

6"(152mm)

11 1/4"(286mm) to

4

3/4"(121mm) to

 

12

3/4"(324mm)

6

1/4"(159mm)

9"(229mm)

14

1/4"(362mm) to

7

3/4"(197mm) to

 

15

3/4"(400mm)

9

1/4"(235MM)

12"(305mm)

17

1/4"(438mm) to

10

3/4"(273mm) to

 

18

3/4"(476mm)

12

1/4"(311mm)

Figure 16

 

DVP42

DVP48

"A"

"B"

"B"

6"(152mm)

4"(102mm) to

4"(102mm) to

 

5 1/2"(140mm)

5"(127mm)

9"(229mm)

6"(152mm) to

6"(152mm) to

 

7 /2"(191mm)

7 1/2"(191mm)

12"(305mm)

9"(229mm) to

9"(229mm) to

 

101/2"(267mm)

10 1/2"(267mm)

Figure 18

17375-6-0705

Page 13

VENTING FIREPLACE - TOP

To Use the Vent Graph (Figure 19)

1.Determinethe heightof thecenterof thehorizontalvent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.Select the indicated dimension, and position the unit in accordance with same.

EXAMPLEA:

If the vertical dimension from the floor of the unit is 35 feet, the horizontal run to the outer wall flange must not exceed 6.5 feet.

EXAMPLE B:

If the vertical dimension from the floor of the unit is 6.5 feet, the horizontal run to the outer wall flange must not exceed 14.5 feet.

SPECIAL NOTE: For each 45 degree elbow installed in thehorizontalrun,thelengthofthehorizontalrunMUSTbe reducedby18"(45cm).Thisdoesnotapplyifthe45degree elbows are installed on the vertical part of the vent system. Reduce 3' for every 90° elbow.

Example:According to the chart the maximum horizontal vent length is 20' and if two 45 degree elbows are required in the horizontal vent it must be reduced to 17'.

The maximum number of 45 degree elbows permitted per sidewallinstallationistwo(2).Theseelbowscanbeinstalled in either the vertical or horizontal run.

Note: On vertical venting the first elbow does not get counted.

Venting Graph (Dimensions in Feet)

VERTICALDIMENSIONFROMTHEBOTTOMOFTHEUNIT TOTHECENTEROFTHEFLUEOUTLET WITHVERTICALORHORIZONTALTERMINATIONCAPS

Figure 19

Acceptable vertical and horizontal vent run.

(40' maximum vertical and 20' maximum horizontal) Unacceptable vertical and horizontal vent run.

Page 14

17375-6-0705

VENTING FIREPLACE - TOP (continued)

Below Grade Installation

Whenitisnotpossibletomeettherequiredventterminalclearances of12"(305mm)abovegradelevel,asnorkelkitisrecommended. Itallowsinstallationdepthdownto7"(178mm)belowgradelevel. The 7" (178mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Ensurethesidewallventingclearancesareobserved.Ifventing system is installed below ground, we recommend a window wellwithadequateandproperdrainagetobeinstalledaround the termination area.

TYPICAL BASEMENT INSTALLATION

Figure 20

Examples of possible venting systems using one (1) 90° elbow. Eight (8) feet is listed as minimum vertical vent run with 20 feet ofmaximumhorizontalventrun.Verticaldimensionsarebasedon centerline to centerline of pipe. Horizontal dimensions are based on centerline of pipe to end of termination.

Firestop at

Ceiling Level

Figure 21

Examplesofpossibleventingsystemsusingtwo(2)90°elbows.V is listed as minimum vertical dimensions and H1 + H2 is listed as total of maximum horizontal dimensions. The maximum vertical and horizontal distances for two (2) 90° elbows as shown in Figure 22 is 20 feet.

Attention: Refer to Figure 19 for additional venting requirements.

Firestop at

Ceiling Level

Figure 22

17375-6-0705

Page 15

2

30

minimum

 

A

 

CENTER

OF ELBOW

 

OUT

STRAIGHT

 

(MINIMUM)

Figure 24

Figure 23

MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALLHORIZONTALINSTALLATIONS WITH 90 DEGREE ELBOW OFFTOPOF FIREPLACE

FIREPLACE

HARD ELBOW DIMENSIONS

SERIES

"A"

"B"

"C"

DVP42FP

43-1/2"

5"

7"

 

(1105mm)

(127mm)

(178mm)

DVP48FP

43-1/2"

5"

7"

 

(1105mm)

(127mm)

(178mm)

 

 

 

 

FIREPLACE

FLEX PIPE 90 DEGREE BEND

SERIES

"A"

"B"

"C"

DVP42FP

46"

5"

7"

 

(1143mm)

(127mm)

(178mm)

DVP48FP

46"

5"

7"

 

(1143mm)

(127mm)

(178mm)

Positioning the Fireplace

Determinetheexactpositionoftheappliancesothedirectventtermination will be centered (if possible) between two (2) studs. This will avoid any extra framing. All vent kit pipes should be assembled on the unit after the unit is moved into the final position.

Cutting the Hole (Figures 23)

Afterthefireplacehasbeenpositionedinitspermanentlocation,thehole through the exterior wall of the house can be cut. This hole must be 12" (305mm)highx10"(254mm)widewithitscenterlinedeterminedbythe amountofverticalriseandhorizontalrunofthetermination.(SeeFigure 23) When locating the hole it must be noted that the bottom of the cap must be 12" (305mm) above the ground level, and top of the cap must be no less than 18" (457mm) below a combustible projection, and no closer than 9" (229mm) to any wall running parallel to vent termination.

(See Figure 24)

MAXIMUM HORIZONTAL

RUN WITH NO VERTICAL

RISE AND 90° ELBOW

MAXIMUM HORIZONTAL RUN WITH MINIMUM VERTICAL RISE AND 90° ELBOW

Figure 25

Page 16

17375-6-0705