Emerson TRANSMITTER 3350, TRANSMITTER 3700 User Manual

0 (0)

Quick Reference Guide

P/N 20001008, Rev. B

August 2005

Model 3700 Transmitter (MVD) or

Model 3350 Peripheral

Installation Instructions for Field-Mount

For technical support, phone the support center nearest you:

In the U.S.A., phone 1-800-522-MASS (1-800-522-6277)

In Canada and Latin America, phone (303) 527-5200

In Asia, phone (65) 6770-8155

In the U.K., phone 0800 - 966 180 (toll-free)

Outside the U.K., phone +31 (0) 318 495 670

BEFORE YOU BEGIN

This quick reference guide explains basic installation guidelines for installing the Micro Motion® Model 3350/3700 MVD applications platform.

For information on I.S. applications, refer to Micro Motion approval documentation.

For complete instructions about configuration, maintenance, and service, refer to the instruction manual shipped with the transmitter.

WARNING

Improper installation in a hazardous area can cause an explosion.

For information about hazardous applications, refer to Micro Motion approval documentation, shipped with the transmitter or available from the Micro Motion web site.

WARNING

Hazardous voltage can cause severe injury or death.

Install transmitter and complete all wiring before supplying power.

CAUTION

Improper installation could cause measurement error or meter failure.

Follow all instructions to ensure transmitter will operate correctly.

©2005, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.

1

European installations

This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.

The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the web at www.micromotion.com/atex or through your local Micro Motion support center.

Installation kit

The Model 3350/3700 installation kit includes the parts shown in Figure 1.

Figure 1. Field-mount installation kit

Mounting bracket

4 x Lock washer

Transmitter can be oriented on bracket. See Step 3.

4 x Flat washer

4 x M8x16 Bolt assemblies

2

STEP 1. Choosing a location

Choose a location for the transmitter based on the requirements described below.

WARNING

Improper installation in a hazardous area could cause an explosion.

Install the transmitter in an area that is compatible with the rating on the approvals tag. See Figure 3.

Environmental requirements

Install the Model 3350/3700 according to specified limits:

Ambient temperature: –4 to +140 °F (–20 to +60 °C)

Dimensions

See Figures 2, 3, and 4 for Model 3350/3700 dimensions.

Visibility of tags

To ensure personal and system safety, all tags attached to the housing must remain visible. Clean them as often as necessary. Replace tags that are damaged, missing, or worn. See Figure 3 for location of approvals tag.

3

Emerson TRANSMITTER 3350, TRANSMITTER 3700 User Manual

Figure 2.

Dimensions – face view

 

12

inches

 

 

(305)

 

 

(mm)

11

 

 

(279)

 

4 x 5/16-inch (9 mm) diameter

9 3/16

(234)

213/16

(71)

4

(102)

Mounting bracket can be rotated as needed

Display cover can be

3 5/8

rotated as needed

(92)

6

(152)

Figure 3. Dimensions – top view

inches (mm)

5 1/16-inch (129 mm) clearance for removal of circuit boards

Approvals tag

11 5/16

(288)

6 1/8

(158)

8 11/16

(221)

15 1/2

(394)

4

Figure 4. Dimensions – conduit openings view

inches

 

2 x 2 13/17

1 7/8

(71)

(mm)

 

(48)

 

 

2 x 15/16

 

 

(24)

 

Case ground

 

 

5 x 3/4–14 NPT

 

 

or

 

 

5 x M20 x 1.5 – 6H

 

 

10 3/8

(265)

7 1/2

(191)

5 3/4

(147)

Mounting surface

Cable lengths

Maximum cable length from the sensor to the Model 3700 transmitter depends on the installation type and cable type:

4-wire remote transmitter: see Figure 5, then refer to Table 1 for maximum length of the 4-wire cable.

Remote core processor with remote transmitter: see Figure 6, then refer to Table 1 for maximum length of the 4-wire cable and the 9-wire cable.

If you are installing the Model 3350 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3350’s frequency input is 500 feet (150 meters).

5

Figure 5. 4-wire remote transmitter

Sensor

Model 3700

4-wire cable

Core processor (standard or enhanced)

Figure 6. Remote core processor with remote transmitter

Model 3700

Sensor

4-wire cable

 

9-wire cable

Core processor

Junction box

(standard only)

Table 1.

Maximum cable lengths

 

Cable type

 

Wire gauge

Maximum length

 

 

 

 

Micro Motion 9-wire

Not applicable

60 feet (20 meters)

 

 

 

 

Micro Motion 4-wire

Not applicable

1000 feet (300 meters)

 

 

 

 

 

User-supplied 4-wire

 

 

 

 

Power wires (VDC)

22

AWG (0,35 mm2)

300 feet (90 meters)

 

 

 

 

 

 

 

 

 

 

20

AWG (0,5 mm2)

500 feet (150 meters)

 

 

 

 

 

 

 

 

 

 

18

AWG (0,8 mm2)

1000 feet (300 meters)

 

 

 

 

 

 

Signal wires (RS-485)

22

AWG (0,35 mm2) or larger

1000 feet (300 meters)

 

 

 

 

Cable from transmitter’s FO

 

Not applicable

500 feet (150 meters)

to Model 3350’s FI(1)

 

 

 

 

 

 

 

 

 

 

 

(1)Applies only to the Model 3300 applications peripheral when receiving frequency input from a remote Micro Motion transmitter such as an IFT9701 or RFT9739.

6

STEP 2. Preparing conduit openings for ATEX Zone 1

If the Model 3350/3700 carries an ATEX Zone 1 approval:

1.Remove thread protectors from conduit openings (see Figure 7).

2.Install factory-supplied cable glands or user-supplied EExe cable entry devices in conduit openings that are in use.

3.Install EExe plugs in conduit openings that are not in use.

STEP 3. Orienting the Model 3350/3700 (optional)

The Model 3350/3700 can be oriented on the mounting bracket as needed, and the display cover can be rotated on the applications platform. Figure 7 provides orientation examples.

To orient the Model 3350/3700:

1.Use the four supplied mounting bolt assemblies.

2.Using a 13 mm hex wrench, install the bolt assemblies to 12 ft-lb (16 Nm) of torque.

To rotate the display cover, if needed, see the transmitter installation manual.

Figure 7. Orientation examples

Conduit openings left

Conduit openings for

 

intrinsically safe

Display cover

sensor wiring

 

Conduit openings for

 

non-intrinsically safe

 

input/output wiring

 

Conduit openings

Conduit openings

right

down

7