!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

NOTE: This product is suitable for use in wet locations when installed in a GFCI protected branch circuit.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

U.L. Model No.: CF654

2

THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS

PORCHES, PATIOS, AND DECKS.

This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One wire stripper

Three wire connectors (supplied).

MATERIALS

Wiring, electrical box and box connectors must be of type required by the local code. The minimum wiring would be a 3-conductor (2-wire with ground) of following sizes:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50 - 100 ft.

12

!WARNING

Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 7). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each assembly step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

Check to see that you have received the following parts:

A.Fan motor assembly

B.One ceiling cover

C.Five blade flanges

D.Five fan blades

E.One hanger ball/downrod assembly

F.One hanger bracket.

G.One loose parts bag containing:

1.Sixteen M5 x 6 washer head blade screws

2.One M6 x 14 flange screw with lockwasher

3.One wood ball

4.Three wire connectors

5.One clevis pin

6.One hairpin clip

7.Two threaded studs

8.Two lockwashers

9.Two knurled knobs

10.One chain coupling

NOTE: Place the parts from the loose parts bag in a small container to keep them from being lost.

A B

C

D

G

E F

U.L. Model No.: CF654

3

Emerson CF654WW00, CF654AW00, CF654ORB00, CF654WB00 User Manual 2

How to Put Your Ceiling Fan Together

1.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.

PIN

 

HANGER

 

BALL

 

DOWNROD

SETSCREW

 

Figure 1

2.Unscrew the two upper setscrews (Figure 2) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews are securely tightened. Failure to verify that the pin and setscrews are properly installed (as shown in Figures 2 & 3) could result in the fan falling.

 

MOTOR

DOWNROD

COUPLING

UPPER

 

SETSCREW (2)

HAIRPIN

CLEVIS PIN

CLIP

 

DOWNROD

 

CLEVIS

 

PIN

CLEVIS PIN

 

UNTIGHTEN

HAIRPIN

UPPER

CLIP

SETSCREW

 

 

UNTIGHTEN

 

UPPER

Figure 2

SETSCREW

3.Tighten the two upper setscrews (Figure 2) securely while pulling up on the downrod.

NOTE: The setscrews must be properly installed as described above, or fan wobble could result.

4.Place the ceiling cover over the downrod, making sure that the large opening faces upward (Figure 3).

DOWNROD

CEILING

COVER

RETIGHTEN

UPPER

SETSCREW

 

RETIGHTEN

Figure 3

UPPER

SETSCREW

5.Reinstall the hanger ball on the downrod as follows (Figure 4) . Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.

 

PIN

HANGER BALL

 

DOWNROD

CEILING

 

COVER

 

SETSCREW

Figure 4

6.The fan comes with blue, black and white leads that are 80-inches long. Before installing the fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.