READ AND SAVE THESE INSTRUCTIONS

CARRERA VERANDA

52” Ceiling Fan

Wet Location Owner's Manual

Model Numbers

CF552AW00 - Summer White

CF552GBZ00 - Gilded Bronze

CF552GES00 - Golden Espresso

CF552ORB00 - Oil Rubbed Bronze

CF552WB00 - Weathered Bronze

Net Weight: 21.60 Lbs.

Part No. F40BP73930001

Form No. BP7393-1

 

U.L. Model No.: CF552

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This product is suitable for use in wet locations when installed in a GFCI protection branch circuit.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label.

You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: CF552

THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS. USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS.

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One wire stripper

 

Three wire connectors (supplied)

 

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

 

 

!WARNING

Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!

WARNING

7.

Three wire connectors

8.

Two threaded studs

Do not install or use fan if any part is damaged or

9.

Two knurled knobs

missing. Call Toll-Free:

10.

Two lockwashers

1-800-654-3545

11.

One clevis pin

12.

One hairpin clip

 

 

13.

One balance kit

!

WARNING

 

 

NOTE: Place the parts from the loose parts bags

 

 

 

 

in a small container to keep them from being lost.

This product is designed to use only those parts

 

 

 

 

If any parts are missing, contact your local

supplied with this product and/or any accessories

 

 

 

 

retailer or catalog outlet for replacement before

designated specifically for use with this product by

 

 

 

 

proceeding.

Emerson Electric Co. Substitution of parts or

 

 

 

 

2. Remove the fan assembly from the protective

accessories not designated for use with this product

 

 

 

 

by Emerson Electric Co. could result in personal

 

 

plastic bag. Place the fan assembly into the upper

 

 

injury or property damage.

 

 

foam pad with the bottom of the motor facing up.

 

 

 

 

The upper foam pad serves as a holder for the fan

1. Check to see that you have received the following

 

 

during the first stages of assembly.

parts:

NOTE: If you are uncertain of part description,

 

 

FAN BLADES

 

 

 

refer to exploded view illustration.

 

 

BRACKET SWITCH

a. Fan motor assembly

 

 

HOUSING ASSEMBLY

 

 

 

b. One switch housing assembly

 

 

 

c. One ceiling cover

 

 

 

d. Five blade flanges

 

 

 

e. One hanger ball/4.5” downrod assembly

 

LOOSE PARTS

 

f. One hanger bracket

 

BAG

FAN MOTOR

 

 

g. One coupling cover

 

BLADE

ASSEMBLY

 

 

h. Five fan blades

 

FLANGES

 

 

 

 

i. One bracket switch housing assembly

 

 

 

j. One loose parts bag containing:

 

 

SWITCH HOUSING

1. Sixteen M5 x 6mm washer head

 

 

ASSEMBLY

blade screws

 

 

HANGER BALL/

2. One M4 x 12mm flat head screw

 

 

 

 

DOWNROD ASSEMBLY

3. One M6 x 14mm pan head screw with

 

 

 

lockwasher

 

CEILING

HANGER

4. One M4 x 10mm serrated pan head

 

BRACKET

 

COVER

 

screw

 

 

COUPLING

5. One die-cast pendant

 

 

 

 

COVER

6. One pendant coupler

3

 

U.L. Model No.: CF552

 

 

Emerson CF552AW00, CF552GBZ00, CF552WB00, CF552GES00, CF552ORB00 User Manual

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before attempting installation. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

How to Put Your Ceiling Fan Together

1.One by one unscrew each screw and discard screw and shipping retainer (Figure 1).

ADAPTER

PLATE

REMOVE AND DISCARD

THE FIVE SHIPPING

RETAINERS AND SCREWS

FROM THE ADAPTOR

PLATE

Figure 1

2.Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws (Figure 2).

NOTE: Take care not to scratch fan housing when installing blades.

M5 x 6mm WASHER HEAD BLADE SCREW (3 per blade/flange)

FAN BLADE

BLADE FLANGE

Figure 2

3.Loosely attach one blade/flange assembly to the motor hub by securing the two M6 x 14mm captive pan head screws. Make sure the screws are NOT tightened (Figure 3). Repeat this procedure for other four blade assemblies.

!WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.