Emerson CF4801WW00, CF4801GES00, CF4801CK00, CF4801BS00, CF4801GBZ00 User Manual

...
0 (0)

READ AND SAVE THESE INSTRUCTIONS

Fan Blades

 

Not Included

 

Ceiling Fan Owner's Manual

PREMIUM

CROWN

SELECT

SELECT

Model Numbers

Model Numbers

CF4801AB00

CF4501AP00

CF4801AP00

CF4501GBZ00

CF4801BS00

CF4501GES00

CF4801CK00

CF4501VNB00

CF4801GBZ00

 

CF4801GES00

 

CF4801ORB00

 

CF4801VNB00

 

CF4801WW00

 

Net Weight: 23.8 Lbs.

Part No. F40BP74470000

Form No. BP7447

 

U.L. Model No.: CF4801 and CF4501

!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-2011” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: All setscrews must be checked and re-tightened where necessary before installation. NOTE: This fan is suitable for use with solid-state speed controls.

WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: CF4801 and CF4501

This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One wire stripper

 

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

 

 

!WARNING

Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 8). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

1.Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a.Fan motor and housing assembly

b.One motor cover

c.One ceiling cover

d.Five blade flanges

e.One hanger ball/downrod assembly

f.One hanger bracket

g.One uplight lead assembly

h.Three 25-watt candelabra bulbs

i.One loose parts bag containing:

1.One setscrew

2.One 5/32" hex wrench

3.Eleven 10-32 x 5/8" oval head screws

4.Two 1” threaded studs

5.Two 1-1/4” threaded studs

6.Four knurled knobs

7.Three wire connectors

8.Two screws, 8-32 x 3/8"

9.Two pull chain pendant and coupling

10.One hairpin clip

11.One clevis pin

12.Two lockwashers

13.Twenty-one #10-24 x 12mm pan head screws

14.Twenty-one flat washers

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

2.Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly.

3.Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface.

CEILING

BLADE

UPLIGHT LEAD

COVER

ASSEMBLY

FLANGES

 

 

3 25-WATT

 

CANDELABRA

LOOSE

BULBS

PARTS BAG

 

FOAM

 

 

PACKING

HANGER

HANGER BALL/

 

BRACKET

 

DOWNROD

 

 

ASSEMBLY

 

MOTOR AND

 

HOUSING ASSEMBLY

MOTOR

PROTECTIVE COVER

PLASTIC BAG

FOAM

PACKING

CARTON

3

U.L. Model No.: CF4801 and CF4501

Emerson CF4801WW00, CF4801GES00, CF4801CK00, CF4801BS00, CF4801GBZ00 User Manual

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

How to Put Your Ceiling Fan Together

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

1.Position the fan motor and housing assembly in the lower foam packing so that the top of the motor is facing you.

2.Separate, untwist and unkink the four motor leads.

3.Obtain the hanger ball/downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod , then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 6.

4.Route the white, blue, and black motor leads through the downrod. Fold the yellow wire into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling (Figure 2).

5.Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the hanger ball to make sure the clevis pin is properly installed.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.

PIN

HANGER

BALL

DOWNROD

SETSCREW

Figure 1

 

DOWNROD

 

HAIRPIN

SETSCREW

CLIP

 

 

MOTOR

 

COUPLING

CLEVIS PIN

 

DOWNROD

 

 

YELLOW LEADS

HAIRPIN

BROWN LEAD

CLIP

RED LEAD

CLEVIS

CLEVIS PIN

PIN

MOTOR

 

COUPLING

 

YELLOW LEAD

 

FROM UPLIGHT

Figure 2

 

4

U.L. Model No.: CF4801 and CF4501

How to Put Your Ceiling Fan Together (continued)

6.Install the setscrew (supplied in loose parts bag) in the motor coupling and tighten using the 5/32" setscrew wrench (supplied) (Figure 3).

7.Screw two 1” threaded studs (provided) into the motor (Figure 4). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover.

NOTE: Make sure the red and brown leads are capped with wire connectors. Make sure the red, brown, and yellow wires and wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor.

8.Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 5).

9.Reinstall the hanger ball on the downrod as follows. Route the motor leads through the hanger ball and slide the hanger ball over the downrod (Figure 5). Install the pin through the holes at the top of the downrod and slide the hanger ball up the downrod, aligning the ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.

!WARNING

It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.

10.The blue, black and white leads exiting the downrod are 80-inches long. Before installing fan, measure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.

DOWNROD

SETSCREW

Figure 3

WIRE

CONNECTORS

RED LEAD BROWN LEAD

MOTOR

KNURLED KNOB

MOTOR

COUPLING

COVER

WIRE CONNECTOR

YELLOW LEADS

1" THREADED STUD

7/8"

Figure 4

PIN

HANGER BALL

DOWNROD

SETSCREW

CEILING COVER

Figure 5

5

U.L. Model No.: CF4801 and CF4501

Loading...