Electrolux WGGWDBQQOO, 584109, 584113, WGGWAFQQOO, 9CHG584109 User Manual

...
0 (0)

thermaline S90

GAS COOKERS - FOURNEAUX POUR GAZ

Doc. 62.9540.01_UL

Edition 1 01.2006

US

INSTALLATIONAND OPERATING INSTRUCTIONS

page 3

FR

INSTRUCTIONS D’INSTALLATION ET D’EMPLOI

page 15

 

 

FOR YOUR SAFETY

POUR VOTRE SÉCURITÉ

Do not store or use gasoline or

Ne déposez pas ou n'employez

other flammable vapors or liquids

pas l'essence ou d'autres vapeurs

in the vicinity of this or any other

ou liquides inflammables à pro-

appliance.

 

ximité de ceci ou d'aucun autre

 

 

appareil.

 

 

 

 

 

 

 

WARNING

AVERTISSEMENT

 

Improper installation, adjust-

L'installation inexacte, l'ajuste-

ment, alteration, service or

ment, le changement, le service

maintenance can cause property

ou l'entretien peuvent causer des

damage, injury or death. Read the

blessures matériels, des domma-

installation, operating and

ges ou la mort. Lisez les instruc-

maintenance instructions thorou-

tions d'installation, d'opération et

ghly before installing or servicing

d'entretien complètement avant

this equipment.

d'installer ou entretenir cet

 

 

 

équipement.

 

 

 

 

 

INSTRUCTION

Post in a prominent location instructions to be followed if the user smells gas. Consult the local gas supplier to obtain the information.

Présentez dans des instructions en avant d'un endroit d'être suivi si l'utilisateur sent le gaz. Consultez le fournisseur local de gaz pour obtenir l'information.

Against wall - contre une paroi

Connections - Raccordement

Gas - Gaz

Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION

Doc. 62.9540.01_UL

Free standing - isolé

Connections - Raccordement

Gas - Gaz

Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION

Electrolux WGGWDBQQOO, 584109, 584113, WGGWAFQQOO, 9CHG584109 User Manual

Free standing - isolé

operated from both sides - ulilisable des deux côtés

Connections - Raccordement

Gas - Gaz

Fig.1 INSTALLATION DRAWINGS - PLANS D'INSTALLATION

Doc. 62.9540.01_UL

CONTENTS

 

I.

tGENERAL INFORMATION................................................................................................

3

II.

INSTALLATION INSTRUCTIONS.......................................................................................

5

III.

OPERATING INSTRUCTIONS............................................................................................

9

SOMMAIRE

 

IV.

INSTRUCTIONS GÉNÉRALES.........................................................................................

15

V.

INSTRUCTIONS RELATIVES À L'INSTALLATION.........................................................

17

VI.

INSTRUCTIONS DE FONCTIONNEMENT .......................................................................

21

APPENDIX

VII. Table of nozzle - Tableau de gigleur

62.9540.01_UL

Page 1

Page 2

62.9540.01_UL

GENERAL INFORMATION

I . GENERAL INFORMATION

1.SAFETY INSTRUCTIONS AND INSTRUCTIONS FOR USE

1.1INSTALLATION AND COMMISSIONING

S The installation, adjustment and initial operation of the appliance must be carried out according to the manufacturer's instructions and may only be done by an authorised specialist.

SInstallations for the supply of electricity and gas must be carried out by approved specialists in compliance with specific national and local regulations. They bear the responsibility.

SThe installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B1 49.1.

SThe appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 psi (3.5 kPA)

SThe appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piiping system at test pressures equal to or less than 1/2 psi (3.5 kPA)

SThe appliance must not be placed in operation until the user has become familiar with its operation. The operating instructions and the related safety precautions must be followed precisely. Follow strictly the attention and warning label indications on the appliances

1.2OPERATOR'S OBLIGATIONS

SThe manager is responsible for ensuring that

all components relevant to safety are in perfect working order at all times. The operating condition of these components must be examined by an authorised specialist at least once a year and any defects remedied if required.

SThe operator of this appliance is responsible for total observation of the national regulations concerning operating safety.

SRemain the manual for future reference.

1.3USE AS PRESCRIBED

SClosed containers must not be heated because of the danger of bursting and injuries.

1.4SAFETY-CONSCIOUS WORKING

STouching the hot cooking plates can cause burns.

S Keep a minimum distance of 16 inch (40 cm) to the appliance, in order to a safety opening of the oven door

SDo not touch the curves of the oven door handle, it can be hot. Use always the straight part..

SThe roasting and baking oven must under no circumstances (not even at the low setting) be operated with a slightly opened door, since the high temperatures can damage the control knobs and gas valve.

SWhen putting oil, fat, water or ingredients in the preheated hot frying pan, they may spit - danger of burning!

SOverheated oil can ignite spontaneously. Never use water to extinguish burning oil, but smother the flames with the lid or a damp cloth.

SThe escape of burnable gases represents a fire and explosion hazard. Action in the case of a gas leak and a smell of gas:

-No smoking, no fire

-Do not operate electric switches or bells.

-Close gas cylinder valves and the main gas valve on the appliance.

-Ventilate the room thoroughly

-Place the leaking gas cylinders upright in the open with valves closed.

SThe waste-gas outlets of the roasting and baking oven become hot. Avoid touching them.

SThe exhaust outlets of the roasting and baking oven are not to be covered by any objects.

SSpraying the appliance or parts of it with a high-pressure cleaning device may cause malfunctions and is not to be done.

STo avoid damage to the appliance, do not let water flow from the mixer tap onto the cooking plates.

SKeep the appliance area free and clear from combustibles

SDo not obstruct the flow of combustion and ventilation air.

SDevices on wheels set up in block configuration must be checked before each start-up whether the potential equalization is connected with the neighbour equipment. The connection may be done only by authorized technical personnel.

SAppliances on wheels must be fastened to the building.

62.9540.01_UL

Page 3

GENERAL INFORMATION

1.5CUSTOMER SERVICE AND REPAIR

SIn the event of a permanent fault which interferes with operation, the appliance must be switched off and disconnected from the power supply.

STo perform maintenance and repairs contact the factory, the factory representative or a local service company.

SRepair, maintenance work and other adjustments are only to be carried out by an authorised specialist. The valid local and national regulations must be observed. This applies especially to burners, ignition, safety and control elements. Parts requiring replacement are only to be replaced by original spare parts. Periodic tests for gas leaks must be carried out. A service contract is therefore recommended.

SCleaning and maintenance must be done only when the heating surfaces are cold. Do not use inflammable liquids to clean the appliance.

SAn obligatory service check is required annually.

2.TECHNICAL DATA

 

 

Width

Cooking

 

Gas

PNC

 

Depth

zones

Burner

Appliance type

oven

Appliances

Height

 

 

 

 

 

 

 

 

inch

mm

 

Power

in kW

 

 

 

 

 

 

 

9CHG584105

WGGRAFQOOO

19.7

500

 

 

 

 

 

2

20

 

9CHG584106

WGGRAAQOOO

35.4

900

 

 

 

35.4

900

 

 

 

9CHG584107

WGGRABQOOO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9CHG584108

WGGWDFQQOO

 

 

 

 

 

 

 

 

 

 

 

7.6

9CHG584110

WGGWDAQQOO

39.4

1000

 

 

 

 

 

 

 

9CHG584112

WGGWDBQQOO

 

 

 

35.4

900

4

40

 

 

 

 

9CHG584109

WGGWAFQQOO

 

35.4

900

 

 

 

 

 

 

 

 

9CHG584111

WGGWAAQQOO

 

 

 

 

 

 

 

 

 

 

 

 

9CHG584113

WGGWABQQOO

 

 

 

 

 

 

 

 

 

 

 

 

3.GAS CONSUMPTION

 

Power

BTU

 

7.6

25900

 

20

68200

 

40

136500

 

47.6

163000

 

 

 

4.

PACKAGING

All the packaging materials used are environmentally friendly. They may burnt at an incineration plant or recycled.

5.TESTS / CERTIFICATES

All gas appliances are tested according to the standards ANSI/NSF 4 - 2002 of Commercial Cooking, Rethermalization, and Powered Hot Food Holding and Transport Equipment and ANSI Z83.11-2002 and CSA 1.8-2002 of Gas Food Service Equipment.

6.SPECIFICATION PLATE

The specification plate (E) is located in each case inside and outside on the right of the operator panel (C) (page 6 Fig. 5).

outside on the right of the operator panel (C) (page 6 Fig. 5).

The serial number is marked on the type plate. The 8 digits give following information:

Y

last digit of the year of production

WW

week of production

XXXXX

running number

Page 4

62.9540.01_UL

INSTALLATION INSTRUCTIONS

II . INSTALLATION INSTRUCTIONS

1.

INSTALLATION

1.3

ASSEMBLING TWO APPLIANCES

The appliance is designed for connection to fixed lines. The appliances are suitable for setting up as single appliances or as a group of appliances. They can be set up freely in the room, side by side, at the side and/or at the back against a wall.

Gaps between two appliances or appliance and sidewall should be filled with a FDA approved silicone such as Samco RTV103.

1.1DISTANCES

If an appliance is set up next to or against temperature-sensi- tive furniture or similar, a safety gap of approximately 6“ (150 mm) should be maintained or some form of heat insulation fitted.

The walls must be made up of non-combustible material like tiles or steel.

1.2HEIGHT ADJUSTMENT

Appliance on feet: Alignment is carried out by screwing the lower foot parts in or out.

Appliance on

Irregularities or differences in height can

steel plinth:

be equalized by inserting one or several

 

strips of chrome nickel steel.

Appliance on feet.

D Turn the lower part of the feed to adjust the appliance high.

The feet are adjustable from 4“ to 8“ (100 to 200 mm). A high of 8“ (200 mm) can be recommended and results in an appliance high of 35,4“ (900 mm).

Note:

Adjustment of the legs shall provide an unobstructed clearance of minimal 6“ (150 mm) and maximal 8“ (200 mm) beneath the unit due to sanitary and stability aspects.

The lower part of the foot must not be unscrewed too far. The exposure of threads is prohibited.

(1)

(1)

(2)

a

b

c

Fig.1 Lateral connection

The assembly kit contains two of each of the following:

caged nuts (1 / Fig.1) pre-assembled on the right-hand side of the appliance, hexagonal screws M8x25 (1 / Fig.1) and mounting links (2 / Fig.1).

DRemove the control panels from both appliances as in 2.2

DRemove the front panels from both appliances as in 2.1

DKeeping the screw (1 / Fig.1) loose, turn it until it is approximately 5 mm deep in the caged nut.

Positioning the appliances:

DPlace the appliances next to one other.

DAlign for position and height.

Connect the appliances:

DFit the mounting link (2 / Fig.1) into the inside of the second appliance's left connecting plate.

DTighten the screws.

Note

If required, the caged nuts can also be fitted on the other side of the appliance.

62.9540.01_UL

Page 5

Loading...
+ 21 hidden pages