Electrolux E36GF76GPS, 318201761, E36GF75GPS, E30GF74GPS User Manual

0 (0)

 

 

 

 

 

 

E30GF74GPS E36GF75GPS E36GF76GPS

318201761

 

 

 

 

2 FindingInformation

READ AND SAVE THESE INSTRUCTIONS

NOTE

Installer: Leave instructions with owner. Owner: Read your range Use & Care guide. It contains important safety information for operating this appliance. It also has many suggestions for getting the best results from your appliance.

Read all instructions before installing the range.

For your safety, please read and observe all safety instructions. This guide will help you anticipate all installations connections.

QUESTIONS

For toll-free telephone support in the U.S. and Canada:

1-877- 4ELECTROLUX (1-877-435-3287)

For online support and Internet product information:

www.electroluxusa.com

©2007 Electrolux Home Products, Inc.

Post Office Box 212378, Augusta, Georgia 30917, US All rights reserved. Printed in the USA

Finding Information 3

TABLE OF CONTENTS

Please Read And Save This Guide ....................

2

Questions ..........................................................

2

Table Of Contents .............................................

3

Safety .....................................................................

4

Important Safety Instructions ...............................

4

Definitions ...........................................................

4

Safety Precautions ...........................................

5

Preparing for Installation ...................................

7

Verifying Package Contents ................................

7

Gas/Electric Requirement Table...............................

7

Electrical Power Supply Requirements ..................

8

Gas/Electric Connection Rough-In .....................

9

Cabinet/Countertop Preparation ..........................

10

General Dimensions ........................................

11

Wood/Composite Overlay Installation......................

13

Installing Anti-Tip Bracket ......................................

14

Installing the 36” Range Optional Backguard.........

15

Removing Oven Door..........................................

16

Re-Installing Oven Door..................................

16

Grounding.....................................................

17

Connect Range To Gas Supply.........................

17

Installing Range...............................................

18

Verifying the Operation ......................................

19

To Insure Proper and Safe Operation.....................

20

Converting from Natural Gas To LP Gas.................

21

4 Safety

IMPORTANT SAFETY INSTRUCTIONS

Electrolux E36GF76GPS, 318201761, E36GF75GPS, E30GF74GPS User Manual

Safety 5

SAFETY PRECAUTIONS

6 Safety

WARNING

Never use this appliance as a space heater to heat or warm a room. Doing so may result in carbon monoxide poisoning and overheating of the oven.

Preparing for Installation 7

VERIFY PACKAGE CONTENTS

• Literature Pack

• Griddle (some models)

• Anti-Tip Bracket

• Simmer Plate

• Burner Grate Pack

• Broiler Pan/Insert

• Burner Rings

• Stainless Steel Cleaner

• LP Conversion Kit

• Wok Ring

• Burner Caps

• Oven Racks

GAS AND ELECTRIC REQUIREMENT TABLE

NOTE

This range is shipped from the factory pre-set for use with natural gas. For LP conversion see the accompanying LP Conversion Kit. The electrical information in the table is also located on the serial number label on the range.

Model No.

Electrical

Total

Gas Type

Manifold Pressure

Minimum Gas

 

Circuit

Connected

 

 

Supply

 

 

 

 

Water Column Inches

Water Column Inches

 

 

 

 

 

 

E30GF74GPS

120 V,

5A

Natural

5"

6"

60Hz,

 

 

 

 

Liquid Propane

10"

11"

 

 

 

 

 

 

 

 

 

E36GF75GPS

120 V,

8A

Natural

5"

6"

60Hz,

 

 

 

Liquid Propane

10"

11"

 

 

 

 

 

 

 

 

 

E36GF76GPS

120 V,

5A

Natural

5"

6"

60Hz,

 

 

 

Liquid Propane

10"

11"

 

 

 

 

 

 

 

 

 

8 Preparing for Installation

ELECTRICAL POWER SUPPLY REQUIREMENTS

It is the owner’s responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical installation, including minimum supply wire size and grounding, must be in accordance with the National Electric Code ANSI/NFPA 70-1993* (or latest revision) and local codes and ordinances. In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes.

*A copy of the standard must be obtained from: National Fire Protection Association

1 Batterymarch Park

Quincy, Massachusetts 02269-9101

The correct voltage, frequency, and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a properly sized circuit breaker or time delay fuse.

WARNING

If the gas or electric service provided does not meet the product specifications, do not proceed with the installation. Call the selling dealer, the gas supplier, or a licensed electrician.

NOTES

The power supply must be properly grounded. Improper grounding will result in continuous sparking of the electrodes, even after flame ignition.

If there is any doubt as to whether the power supply is properly polarized or grounded, have it checked by a qualified electrician.

Use 120V, 60Hz, and properly grounded branch circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse.

Preparing for Installation 9

GAS AND ELECTRICAL ROUGH-IN

Locations

A manual shut valve must be installed in the gas piping, external to the appliance, for the purpose of turning on or shutting off gas to the appliance. Place the location of the range and the gas supply to allow access to the valve when the unit is installed. Access to the remote circuit breaker panel/fuse box, with the range in place, must also be allowed for in the installation. Any openings in the wall behind the appliance and in the floor under the appliance must be sealed. Both the gas supply piping and shut-off valve, and the electrical junction box/ receptacle must be located so they do not interfere with the range when it is installed. In addition, the junction box must be located so the range can be removed for service when the conduit supplied with the unit is attached to the junction box. Do not lengthen the conduit or wiring provided with the range.

NOTES

The areas shown in the illustrations, denote the location of the gas stub and the electrical junction box/receptacle. These are suggested locations. For replacement purposes, the location of the existing utilities may be utilized provided that they do not interfere with the sides or rear of the range. If installing the gas valve behind the range, verify that local building codes will permit this.