Electro-Voice CPS 3, CPS 4 User Manual

0 (0)
Electro-Voice CPS 3, CPS 4 User Manual

OWNER’S MANUAL

CPS 3 / CPS 4

CONTRACTOR PRECISION SERIES

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a damp cloth.

7.Do not block any of the ventilation openings.

Install in accordance with the manufactures instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.

9.Only use attachments/accessories specified by the manufacturer.

10.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been

damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has

been dropped.

For US and CANADA only:

Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrican for replacement of the absolete outlet.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times.

The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS - circuits have to be observed.

Note:

SAFETY COMPONENT (HAS TO BE REPLACED WITH ORIGINAL PART ONLY)

8

DESCRIPTION

CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

DESCRIPTION

First of all, we would like to express our thanks and at the same time congratulate you on the decision to buy one of our CONTRACTOR PRECISION SERIES power amplifiers.

Electro-Voice CONTRACTOR PRECISION SERIES amplifiers are made to meet the highest requirements of any on-the-road application. Thus they provide on-board protection against thermal and capacitive overload, short-circuit and the occurrence of HF or DC at the output. Additionally, special circuitry prevents the output-stage transistors from being damaged by Back-EMF. During soft start, delayed switching of the power outputs is accomplished via relays and a limiter controls the initial current inrush, preventing the mains fuse from being blown during the power-on operation.

The mechanical construction as well is carried out following the highest precision standards of the industry. The robust steel chassis provides extreme rigidity and it is meant to live through any hard wearing condition of a touring application. Thermal stability is guaranteed by two 4-Mode silently running fans that offer the possibility to also use the amplifiers in a studio environment.

The extensive comparator circuitry constantly monitors the input and output signals and activates the internal limiters whenever a non-linear operational state is encountered. This provides reliable protection of the connected loudspeaker systems against overload and clipping. The sound quality of the CONTRACTOR PRECISON SERIES power amplifiers is superb. Using comprehensive dimensioned power supply units with low-interference toroidal transformers gains a headroom that exceeds the nominal power handling capacity by far. No V/I-Foldback-Limiter circuits are employed within the power amplifiers, making it possible to operate the amps on complex loads up to ±90° phase angles without a problem.

The input facilities are carried out as balanced XLRF-type sockets while the Direct-Outs – on which the carried-through signals are present – come as XLRM-type connectors. Using the Input Routing-switches lets you determine if the CONTRACTOR PRECISION SERIES amplifiers are operated in DUAL (stereo) or PARALLEL (monaural) mode; “mono-bridged” operation is also possible.

The dB-scaled level controls are to be found on the rear panel. These potentiometers guarantee precise and reliable operation. The easy readable LED display offers quick optical information on the power amplifiers’ momentary operational mode. For each channel individually the display shows whether they are operational, a signal is present at the outputs, when the limiters are activated, and whether one of the protection circuits has been engaged or not. The power outputs CANNEL A, CHANNEL B and BRIDGED OUT are carried out as Speakon connectors. A ground-lift switch that separates the enclosure from the appliance’s ground potential and therefore helps to eliminate ground noise loops and the mono bridged mode switch are also located on the rear panel. In normal operation all CONTRACTOR PRECISION SERIES power amplifiers can be used to drive loads down to 2 ohms; in bridged mode the minimal load is 4 ohms. All amps are equipped with extremely silent running fans providing front-to-rear air circulation, guaranteeing trouble-free operation even in smaller power amplifier rack systems.

Studying this owner’s manual carefully will provide you with further and more detailed information about the CONTRACTOR PRECISION SERIES power amplifiers. Thus we recommend to keep on reading, assuring you that the Electro-Voice CONTRACTOR PRECISION SERIES power amplifiers will provide you with a lot of fun and satisfaction in your work.