Dimensions

(millimetres)

 

 

 

600 mm - 400W

 

 

 

 

 

 

 

800 mm - 800W

 

 

 

 

 

 

 

 

 

 

Models

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DXLWP400

400W

Neon Heat Switch

 

 

 

 

 

 

DXLWP400TI

400W

Neon Heat Switch / 24 Hour Timer

 

 

 

 

 

 

DXLWP800

800W

Neon Heat Switch

 

 

 

 

 

 

DXLWP800TI N

800W

Neon Heat Switch / 24 Hour Timer

 

 

 

 

500 mm

 

 

 

 

 

 

ARLWP800TI

800W

2 Neon Heat Switches / 24 Hour Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THESEINSTRUCTIONSSHOULDBEREADCAREFULLYANDRETAINEDFORFUTUREREFERENCE

Important Safety Advice

WARNING –THIS APPLIANCE MUST NOT BE USED IN A BATHROOM.

WARNING - DO NOT USE THIS HEATER IN THE IMMEDIATE

SURROUNDINGS OFABATH,ASHOWER ORASWIMMING POOL.

WARNING – THIS HEATER MUST NOT BE LOCATED IMMEDIATELY BELOWAFIXED SOCKET OUTLET.

The plug must be accessible after heater installation.

DO NOT USE THE HEATER UNTIL THE FEET OR WALL BRACKETSAREFITTEDCORRECTLY.

FOLLOW these instructions carefully.

The heater carries a warning ‘DO NOT COVER’ to alert the user to the risk of fire that exists if the heater is accidentally covered.

Models DXLWP400TI, DXLWP800TIN and ARLWP800TI can be set to switch on automatically. Remember to observe all safety warnings at all times.

This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance.

If young children, the aged or infirm are likely to be left in the vicinity of the heater, we advise that adequate precautions should be taken. We recommend a guard be fitted to ensure contact with the heater is avoided and objects cannot be inserted into the product.

If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

For further information, please contact our guard supplier direct on Tel. No. 01603 667957, or in case of difficulty or for further advice contact the Customer Helpline.

Electrical Connection

WARNING THISAPPLIANCE MUST BE EARTHED

If the socket outlets in your home are not of the 13 amp BS1363 type they will not accept the plug connected to this heater, therefore cut off the plug. When cut off this plug can constitute a shock hazard if inserted into a socket outlet. It must therefore be disposed of safely.

Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code.

GREEN/YELLOW:

EARTH

BLUE:

NEUTRAL

BROWN:

LIVE

Connect the Green/Yellow wire to the terminal marked E or the

earth symbol or coloured Green or Green/Yellow.

Connect the Brown wire to the terminal marked L or coloured

Red.

Connect the Blue wire to the terminal marked N or coloured

Black.

DO NOT connect the Brown (Live) or the Blue (Neutral) wires to the Earth terminal of your 13 amp plug. If the terminals of the plug are unmarked or you are in any doubt, consult a qualified electrician.

CAUTION: If you use this heater in conjunction with a thermal control, programme controller, timer or any other device which switches the heater on automatically observe all safety warnings at all times.

Dimplex DXLWP400, DXLWP800TI N, DXLWP800, DXLWP400TI, ARLWP800TI User Manual

Positioning the Heater

Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below (wall mounted) and 25mm each side. Curtains must not be closer than 150mm from the top of the heater.

Free Standing Operation (see Fig. 1)

NEVER USE THE HEATER FREE STANDING WITHOUT THE FEET FITTED (FEETARE PACKED SEPARATELY IN CARTON).

1.Lay the heater on its front.

2.Remove the two socket head screws from the base of the heater using the hexagon key supplied.

3.Place feet over base of heater, align holes and engage hook on foot into the recess on the back of the heater - see Fig. 1.

4.Replace the screws but do not overtighten.

Fig. 1

Rear View

Installation

The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3 Rawlplugs, 1 Mounting Bracket and 1 Hexagon Key.

Wall Mounted Operation (see Fig. 2)

Suggested Fixings

SOLID BRICK/BLOCK: No. 8 Rawlplug inserts, 6mm drill bit.

PLASTERBOARD: If possible locate studding and use No. 8 woodscrews directly into the wood, otherwise M5 rawlplug intersets are suitable.

NOTE: FOR OTHER WALL TYPES (e.g. Timber frame and hollow concrete) SEEK SPECIALIST ADVICE.

1.Select the position for the heater ensuring there is clearance from any furniture and fittings of at least 150mm above the heater, 50mm below and 25mm each side.

Curtains must not be closer than 150mm from the top of theheater.

2.Position the drilling template provided on the wall ensuring it is level. Mark the position of the relevant holes on the wall at the edge of template. Before drilling check that the distance between the hole centres is correct, 340mm for 400W Models and 540mm for 800W models (see Fig. 2).

130mm

340mm - 400W

130mm

150mm

 

 

540mm - 800W

 

 

 

 

 

95mm

25mm

Drilling Holes

420mm

25mm

 

Bracket

 

 

50mm

 

 

 

Fig. 2

3.Drill the wall at the three marked positions and fit the wall plugs.

Ensure template has been removed.

4.Fix two No. 8 screws to the top two holes leaving 3mm of the screw exposed. Hang the heater on the screws.

5.Fit the bottom bracket, found in the fixing kit, in the slot at the base of the heater and screw the bracket to the wall.

Test that the heater is now securely fixed to the wall.

Operation

IMPORTANT - OBJECTS OR CLOTHING MUST NOT BE PLACED ON THIS HEATER.

Before using the heater ensure that all warnings and instructions have been read carefully.

OPERATION - SINGLE RATED MODELS

Models DXLWP400, DXLWP400TI, DXLWP800, and DXLWP800TI N

Turn the heater on using the switch on the right side of the heater - the switch will be illuminated.

OPERATION - DUAL RATED MODEL - ModelARLWP800TI

The two switches on the side of the heater control the heat output. Both switches illuminated indicates maximum output.

Top switch only illuminated indicates 500W output on 800W model.

Bottom switch only illuminated indicates 300W output on 800W model.

Note: on models fitted with a timer, at least one switch must be illuminated for the heater to operate.

MODELS WITH TIMER - (see Fig. 3)

DXLWP400TI and DXLWP800TI N - 1 Switch,

The switch on the side of the heater turns the heater on.

Note: This switch must be in the “on” position before the heater will operate.

ARLWP800TI - 2 Switches

The two switches on the side of the heater control the amount of heat available as described above, (Operation - Dual Rated Model).

NOTE: At least one switch must be in the ‘On’ position before the heater will operate.