VENTED DECORATIVE NATURAL GAS LOGS

OWNER’S OPERATION AND

INSTALLATION MANUAL

For more information, visit www.desatech.com

TESTED AND

LISTED BY

RGA 2-72 Approved

Models: PHK-18/24/30; BCS18/24/30

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consultaqualifiedinstaller,service agency, or the gas supplier.

WARNING: This appliance is for installationonlyinasolid-fuelburn- ing masonry or UL127 factory-built fireplace, constructed of noncombustible material, and connected to a working flue. (See page 7 for minimum flue opening.)

WARNING: This is a gas-fired appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to the National Fuel Gas Codes, ANSI Z233.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference

TABLE OF CONTENTS

SAFETY INFORMATION

2

TABLE OF CONTENTS

 

SAFETY INFORMATION..............................................................

2

PRODUCT IDENTIFICATION ......................................................

3

LOCAL CODES ............................................................................

3

UNPACKING ................................................................................

3

INSTALLATION ...........................................................................

4

OPERATING APPLIANCE............................................................

8

CLEANING AND MAINTENANCE................................................

8

SERVICE HINTS..........................................................................

8

TECHNICAL SERVICE ................................................................

8

REPLACEMENT PARTS..............................................................

8

TROUBLESHOOTING .................................................................

9

ACCESSORIES .........................................................................

11

ILLUSTRATED PARTS BREAKDOWN .....................................

12

PARTS LIST ..............................................................................

13

OWNER’S REGISTRATION FORM ...........................................

14

WARRANTY INFORMATION ......................................

Back Cover

SAFETY INFORMATION

WARNINGS

WARNING:Thisproductcontainsand/orgenerates chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.

WARNING: Keep flue open when operating unit.

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the log set may not be working properly. Get fresh air at once! Have log set serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural Gas: Natural gas is odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Makecertainyoureadandunderstandallwarnings.Keepthismanualfor reference. It is your guide to safe and proper operation of this log set.

WARNING: Any change to this log set can be dangerous.

1.This appliance, as supplied, is for use with NATURAL GAS ONLY, as indicated on the rating plate. This appliance is NOT convertible for use with propane/LP gas.

2.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

3.Never install the log set

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the log set

in high traffic areas

in windy or drafty areas

4.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. Inspect chimney flue for damage. If damaged, repair flue before operating heater.

5.You must operate this log set with a fireplace screen in place. Make sure fireplace screen is closed before running log set.

6.This log set is designed to be smokeless. If logs ever appear to smoke, turn off appliance and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and the burning of manufacturing residues. You may wish to add more ventilation by opening a window.

7.To reduce the creation of soot, follow the instructions in Cleaning and Maintenance, page 11.

8.Do not allow fans to blow directly into the fireplace.Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can increase sooting.

9.Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this log set.

For more information, visit www.desatech.com

115425-01

SAFETY INFORMATION

Continued

10.The installation and provisions for combustion and ventilation air must conform with the National Fuel Gas Code, ANSI Z233.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation.

11. Do not run log set

where flammable liquids or vapors are used or stored

under dusty conditions

12.Do not burn solid fuel in the fireplace after installing the log set. Do not use this log set to cook food or burn paper or other objects.

13.Log set becomes very hot when in use. Keep children and adults away from hot surface to avoid burns or clothing ignition. Log set will remain hot for a time after shutdown. Allow surface to cool before touching.

14.Carefully supervise young children when they are in the room with log set.

15.To help prevent breakage, new logs must be broken-in (see Curing Logs page 10).

16.Turn log set off and let cool before servicing, installing, or repairing. Only a qualified service person should install, service, or repair log set.

17.Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Grate

SAFETY INFORMATION

PRODUCT IDENTIFICATION

LOCAL CODES

UNPACKING 3

LOCAL CODES

Install and use log set with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

CAUTION: Do not remove the data plates from the burner pan. The data plates contain important product information.

1.Remove logs, hearth kit, pan materials, and hardware from carton.

2.Remove all protective packaging applied to logs and base for shipment.

3.Check all items for any shipping damage. If damaged, promptly inform dealer where you bought the product.

Burner

Burner Inlet

Pan

(Under Pan)

Figure 1 - Product Identification (Ramp Pan Burner)

Hearth Kit Model _________________________

Serial Number ___________________________

Log Set Model ___________________________

For more information, visit www.desatech.com

115425-01

INSTALLATION

Flue Opening Specifications Check Gas Type

4 Venting Specifications for Installation

INSTALLATION

CAUTION: Do not remove the data plates attached to the burner pan. The data plates contain important warranty information.

WARNING: Before installing in a solid fuel burning fireplace,thechimneyflueandfireboxmustbecleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue before operating heater.

NOTICE: Installation, service, and repair of this appliancemustbeperformedbyaqualifiedinstaller,service agency, company or gas supplier experienced with this type of gas appliance. Only factory authorized components listed in these instructions may be used in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Any modifications to this kit, or use of unauthorized components or accessory items will void the manufacturer’s warranty, and may result in a hazardous condition.

FLUE OPENING SPECIFICATIONS

Note: This vented appliance must be installed only in a solid-fuel burning fi replace with a working fl ue and constructed of noncombustible material.

The charts in Figure 2 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifi cations shown are applicable before installation is attempted.

The fi replace must include a working fl ue and venting system with

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, you MUST NOT install this gas log set

If the fireplace does not have a gas supply shutoff valve, one must be installed.

Model

Burner

 

 

BTU Input

 

 

Minimum Vent

Description

 

(Natural Gas)

 

Opening

 

 

 

PHK/ BCS 18

18" Ramp

 

57,000

 

 

 

8"

PHK/ BCS 24

24" Ramp

 

80,000

 

 

 

8"

PHK/ BCS 30

30" Ramp

 

90,000

 

 

 

8"

 

 

 

 

 

 

 

 

Minimum Fireplace Dimensions

 

 

Model

 

Front

 

Back

 

Depth

Height

 

Width

 

Width*

 

 

 

 

 

 

 

 

 

PHK/ BCS 18

 

28"

 

 

18"

 

16"

 

18"

PHK/ BCS 24

 

36"

 

 

23"

 

16"

 

18"

PHK/ BCS 30

 

42"

 

 

29"

 

18"

 

18"

* At depth Indicated

Fuel Inlet Pressure Specifi cations (W.C.)

Min. Max.

N.G. 5.5" 10.5"

Burner Orifi ce Sizing

Log Size

Natural Gas

In.

Num.

 

18"

.120

31

24"

.140

28

30"

.1495

25

Figure 2 - Technical Information Charts

VENTING SPECIFICATIONS FOR

INSTALLATION

The fireplace chimney flue and vent must be drafting properly. To check the vent for proper drafting: Light a tightly rolled newspaper on one end and place it at the inside front edge of the fireplace. Observe the smoke and be sure the vent is properly drawing it up the chimney. If the smoke spills out into the room, extinguish the flame and remove any obstruction until proper venting is achieved.

The chimney flue must remain open a minimum of 3" at all times during the operation of this log set.

For more information, visit www.desatech.com

115425-01

INSTALLATION Installing Damper Clamp

Connecting to Gas Supply

5

INSTALLATION

Continued

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to the leading edge of the damper as shown in Figure 3. If for any reason this clamp doesn't work on your fireplace, another suitable clamp or permanent stop must be installed, or the damper blade must be cut or removed.

Damper Clamp

Damper

Clamp

Damper

Damper

 

Damper

Masonry Fireplace

Manufactured

 

Fireplace

Figure 3 - Attaching Damper Clamp

Installation must include a equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from log set (see Figure 4).

IMPORTANT: Install equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in a clogged burner injector.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap in supply line as shown in Figure 4. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into log set controls. If sediment trap is not installed or is installed wrong, log set may not run properly.

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must connect log set to gas supply. Follow all local codes.

Installation Items Needed

Before installing log set, make sure you have the items listed below.

piping (check local codes)

sealant (resistant to Propane/LP gas)

equipment shutoff valve

test gauge connection

adjustable (crescent) wrench or pliers

sediment trap

tee joint

pipe wrench

Approved Flexible Gas Hose (if allowed by local codes)

CSA Design-Certifi ed Equipment Shutoff Valve With 1/8" NPT Tap*

3" Minimum

From Gas Meter

(5" W.C.** to 10.5"

 

 

 

 

W.C. Pressure)

Cap Pipe Nipple Tee Joint

 

 

 

 

 

 

 

 

 

 

 

 

Sediment Trap

Figure 4 - Gas Connection

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas.Checkyourlocalcodes.Usepipeof1/2"diameter or greater to allow proper gas volume to log set. If pipe is too small, undue loss of volume will occur.

* Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 15.

** Minimum inlet pressure for purpose of input adjustment.

For more information, visit www.desatech.com

115425-01

Loading...
+ 11 hidden pages