Desa CCL3018PTA-NTA, CCL3930NTB User Manual 2

0 (0)
Desa CCL3018PTA-NTA, CCL3930NTB User Manual 2

UNVENTED (VENT-FREE) GAS LOG HEATER OWNER’S OPERATION AND INSTALLATION MANUAL

HI

LO

 

O

N

F

O

F

TOLI

Patent Pending

 

18", 24" AND 30" VARIABLE

18", 24" AND 30"

MANUALLY-CONTROLLED

THERMOSTATICALLY-CONTROLLED

MODELS

MODELS

CRL2718PA/NA

CCL3018PTA/NTA

CRL3124PA/NA

CCL3924PTA/NTA

CCL3018PA/NA

CCL3930PTB/NTB

CCL3924PA/NA

 

Biltmore Split Oak, Seasonal Oak and Smoky Mountain Oak Logs

Variable Manually-Controlled Models Also

Design-Certified As Vented Decorative Appliances

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Donottouchanyelectricalswitch;donotuseany phone in your building.

Immediatelycallyourgassupplierfromaneighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installationandservicemustbeperformedbyaqualified installer, service agency or the gas supplier.

Save this manual for future reference. For more information, visit www.desatech.com

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or propertydamage.Refertothismanualforcorrectinstallation and operational procedures. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fireplace or in a listed ventless firebox enclosure. It is de- sign-certified for these installations in accordance with ANSI Z21.11.2. Exception: Do not install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must beprovided.RefertoAir for Combustion and Ventilation section on page 5 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

TABLE OF CONTENTS

Safety Information ...............................................

3

Local Codes ........................................................

4

Product Identification...........................................

5

Unpacking ...........................................................

5

Product Features.................................................

5

Air for Combustion and Ventilation......................

5

Installation ...........................................................

8

Operating Heater...............................................

19

Inspecting Burners ...........................................

23

Cleaning and Maintenance................................

23

Service Hints .....................................................

 

24

Technical Service ..............................................

 

24

Troubleshooting.................................................

 

25

Optional Positioning of Thermostat Sensing Bulb ..

28

Specifications ....................................................

 

29

Illustrated Parts Breakdown and Parts List .......

30

Replacement Parts............................................

 

38

Accessories.......................................................

 

38

Parts Central .....................................................

 

39

Warranty Information...........................

Back Cover

2

www.desatech.com

113097-01D

SAFETY INFORMATION

WARNING:Thisproductcontainsand/orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm.

IMPORTANT: Read this owner’s manualcarefullyandcompletely before trying to assemble, operate or service this heater.

Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.

DANGER:Carbonmonoxide poisoning may lead to death!

CarbonMonoxidePoisoning:Earlysignsofcarbon monoxide poisoning resemble the flu, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart orlungdiseaseoranemia,thoseundertheinfluence of alcohol and those at high altitudes.

Natural and Propane/LP Gas: Natural and pro- pane/LPgasesareodorless.Anodor-makingagent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING:Donotallowfans toblowdirectlyintothefireplace.

Avoidanydraftsthatalterburner

flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING:Donotuseablower insert, heat exchanger insert orotheraccessorynotapproved for use with this heater.

Due to high temperatures, the applianceshouldbelocatedout oftrafficandawayfromfurniture and draperies.

Do not place clothing or other

flammable material on or near the appliance. Never place any objects on the heater.

Heaterbaseassemblybecomes very hot when running heater.

Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown.Allowsurfacetocool before touching.

Carefully supervise young children when they are in the room with heater.

You must operate this heater with a fireplace screen in place.

Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Donotplacepropane/LPsupplytank(s)inside any structure. Locate propane/LP supply tank(s) outdoors (propane/LP units only).

3.To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity (propane/LP units only).

113097-01D

www.desatech.com

3

SAFETY INFORMATION

Continued

4.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions

if you cannot reach your gas supplier, call the fire department

5.This heater shall not be installed in a bedroom orbathroom unless installed as a vented appliance (Variable Manually-Controlled Models Only) (see Installing Damper Clamp Accessory for Vented Operation, page 11).

6.Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paintbyaqualifiedchimneycleaner.Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating heater.

7.Do not burn solid-fuel in a masonry or UL127 factory-built fireplace in which a vent-free room heater is installed.

8.If fireplace has glass doors, never operate this heater with glass doors closed. If you operate heaterwithdoorsclosed,heatbuildupinsidefireplacewillcauseglasstoburst.Makesurethereare no obstructions across openings of fireplace.

9.This log heater is designed to be smokeless. If logs ever appear to smoke, turn off heater and call a qualified service person. Note: During initial operation, slight smoking could occur due to log curing and heater burning manufacturing residues.

10.Topreventthecreationofsoot,followtheinstructions in Cleaning and Maintenance, page 23.

11.Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.

12.This heater needs fresh, outside air ventilation torunproperly.ThisheaterhasanOxygenDepletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion andVentilation,page5.Ifheaterkeepsshutting off, see Troubleshooting, page 25.

13.Do not run heater

where flammable liquids or vapors are used or stored

under dusty conditions

14.Do not use this heater to cook food or burn paper or other objects.

15.Do not use heater if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room heater andtoreplaceanypartofthecontrolsystemand any gas control which has been under water.

16.Do not operate heater if any log is broken. Do not operate heater if a log is chipped (dimesized or larger).

17.Turn heater off and let cool before servicing. Only a qualified service person should service and repair heater.

18.Operating heater above elevations of 4,500 feet could cause pilot outage.

19.Provide adequate clearances around air openings.

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note: Where listed vented decorative logs are required, thermostat operation is not permitted.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.

Vent-free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts.

4

www.desatech.com

113097-01D

PRODUCT

IDENTIFICATION

Log Set

Burner

Piezo

Ignitor

Control Knob

Base Grate

Figure 1 - Vent-Free Gas Log Heater (Logs May Vary by Model, Seasonal Oak Single Burner Model Shown)

 

UNPACKING

 

CAUTION: Do not remove

thedataplatesfromthegrateas-

sembly. The data plates contain

important product information.

1.

Remove logs and heater base assembly from

 

carton. Note: Do not pick up heater base as-

 

sembly by burners.This could damage heater.

 

Always handle base assembly by grate.

2.

Remove all protective packaging applied to

 

logs and heater for shipment.

3.

Check all items for any shipping damage. If

 

damaged, promptly inform dealer where you

 

bought heater.

PRODUCT FEATURES

OPERATION

This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic dancing, yellowflames.Thisheaterisdesignedforvent-free operation with flue damper closed. It has been tested and approved to ANSI Z21.11.2 standard forunventedheaters.Stateandlocalcodesinsome areas prohibit the use of vent-free heaters. This heater may also be operated as a vented decorative (ANSIZ21.60)productbyopeningthefluedamper (non-thermostat operation only).

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters.The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries or other sources to light heater.

AIR FOR COMBUSTION AND VENTILATION

WARNING:Thisheatershall not be installed in a confined space or unusually tight constructionunlessprovisionsare providedforadequatecombustionandventilationair.Readthe followinginstructionstoinsure proper fresh air for this and other fuel-burning appliances in your home.

Todayʼs homes are built more energy efficient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home.All fuel-burning appliances need fresh air for proper combustion and ventilation.

113097-01D

www.desatech.com

5

AIR FOR COMBUSTION

AND VENTILATION

Continued

Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE VENTILATION

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of one perm (6x10-11 kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow for Heater Location.

Confined and Unconfined Space

National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconfined space.

* Adjoining rooms are communicating only if therearedoorlesspassagewaysorventilationgrills between them.

DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION

Determining if You Have a Confined or Unconfined Space

Use this work sheet to determine if you have a confined or unconfined space.

Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.

1.Determine the volume of the space (length x width x height).

Length x Width x Height =__________cu. ft. (volume of space)

Example: Space size 20 ft. (length) x 16 ft. (width) x 8 ft. (ceiling height) = 2,560 cu. ft. (volume of space)

If additional ventilation to adjoining room is supplied with grills or openings, add the volume of these rooms to the total volume of the space.

2.Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.

__________ (volume of space) x 20 = (Maximum Btu/Hr the space can support)

Example: 2,560 cu. ft. (volume of space) x 20 = 51,200 (maximum Btu/Hr the space can support)

3.Add the Btu/Hr of all fuel burning appliances in the space.

Vent-free fireplace

__________ Btu/Hr

Gas water heater*

__________ Btu/Hr

Gas furnace

__________ Btu/Hr

Vented gas heater

__________ Btu/Hr

Gas fireplace logs

__________ Btu/Hr

Other gas appliances*

+ ________ Btu/Hr

Total

= ________ Btu/Hr

* Do not include direct-vent gas appliances. Di- rect-ventdrawscombustionairfromtheoutdoors and vents to the outdoors.

6

www.desatech.com

113097-01D

AIR FOR COMBUSTION AND VENTILATION

Continued

Example:

 

 

 

Gas water heater

 

40,000

Btu/Hr

Vent-free fireplace

+

39,000

Btu/Hr

Total

=

79,000

Btu/Hr

4.Compare the maximum Btu/Hr the space can support with the actual amount of Btu/Hr used.

_________Btu/Hr (maximum the space can support)

_________Btu/Hr (actual amount of Btu/Hr used)

Example: 51,200 Btu/Hr (maximum the space can support)

79,000 Btu/Hr (actual amount of Btu/Hr used)

The space in the example is a confined space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:

A.Reworkworksheet,addingthespaceofanadjoiningroom.Iftheextraspaceprovidesanunconfined space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.

B.Vent room directly to the outdoors. See Ventilation Air From Outdoors.

C.Install a lower Btu/Hr fireplace, if lower Btu/Hr size makes room unconfined.

If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an unconfined space. You will need no additional fresh air ventilation.

WARNING: If the area in which the heater may be operatedissmallerthanthatdefined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air byoneofthemethodsdescribed in the National Fuel Gas Code,

ANSIZ223.1/NFPA54Section5.3 or applicable local codes.

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting

the two spaces (see options 1 and 2, Figure 2).You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

 

12"

Ventilation

 

Ventilation Grills

Grills

 

Into Adjoining

Or

Into Adjoining Room,

Room,

Option 2

Remove

Option 1

 

Door into

 

 

 

 

Adjoining

 

 

Room,

 

 

Option

 

 

3

 

 

 

12"

Figure 2 - Ventilation Air from Inside Building

Ventilation Air From Outdoors

Provideextrafreshairbyusingventilationgrillsor ducts.You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the

National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostatcontrolledpowervent.Heatedairenteringtheattic will activate the power vent.

 

Outlet

Ventilated

 

Attic

 

Air

 

 

Outlet

 

 

Air

 

To Attic

 

 

 

 

To

 

 

Crawl

Inlet

 

Space

 

 

Air

 

 

 

Inlet Air

Ventilated

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

113097-01D

www.desatech.com

7

INSTALLATION

NOTICE:Thisheaterisintended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a centralheatingsystem,youmay run system’s circulating blower while using log heater. This will helpcirculatetheheatfromyour logheaterthroughoutthehouse.

In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must install heater. Follow all local codes.

NOTICE:Stateorlocalcodesmay onlyallowoperationofthisappliance in a vented configuration.

Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated.Adirtychimneyfluemay createanddistributesootwithin house.Inspectchimneyflueand firebox for damage. If damaged, repair flue and firebox before operating heater.

WARNING: Seal any fresh air vents or ash clean-out doors located on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat-resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom unless installed as a vented appliance (Variable Manually-

Controlled Models Only) (see page 11)

in a recreational vehicle

where curtains, furniture, clothing or other flammable objectsarelessthan42inches from the front, top or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids,oilorkerosenelamps,etc.)in the air exist, may discolor walls or cause odors.

IMPORTANT: Vent-free heaters add moisture to theair.Althoughthisisbeneficial,installingheater inroomswithoutenoughventilationairmaycause mildew to form from too much moisture. See Air for Combustion and Ventilation, page 5.

CHECK GAS TYPE

Use the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.

WARNING: This appliance is equipped for (natural or propane/LP) gas. Field conversion is not permitted.

8

www.desatech.com

113097-01D

INSTALLATION

Continued

INSTALLATION AND CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the minimum clearances. If you can, provide greater clearances fromfloor,ceilingandadjoining wall.

MINIMUM FIREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

 

Ceiling

18", 24", 30"

 

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

Minimum Firebox

Log

 

 

 

 

Front

Rear *

Size

 

Height

 

Depth

Width

Width

 

 

 

 

 

 

 

 

18"

 

17"

 

14"

24"

 

20"

24"

 

17"

 

14"

28"

 

21"

30"

 

17"

 

14"

34"

 

24"

 

 

 

 

 

 

 

 

* Measured at 14" depth.

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127listed manufactured fireplace or certified vent-free firebox.

Minimum Clearances For Side Combustible Material, Side Wall and Ceiling

A.Clearances from the side of the fireplace cabinet to any combustible material and wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 4).

Note: When installing your gas logs into a manufactured firebox, follow firebox manufacturerʼs instructions for minimum clearances to combustible materials.

B.Clearancesfromthetopofthefireplaceopening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 4 - Minimum Clearance for Combustible to Wall

NOTICE:Manualcontrolheaters maybeusedasaventedproduct. Ifso,youmustalwaysrunheater with chimney flue damper open. If running heater with damper open, noncombustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Minimum Noncombustible Material Clearances If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel, page 10. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5, page 10 for minimum clearances.

IMPORTANT:Ifyoucannotmeettheseminimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

113097-01D

www.desatech.com

9

INSTALLATION

Continued

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and 6 and Figure 7 on page 11 for minimum clearances.

Noncombustible

Requirements for

Material

Safe Installation

Distance (A)

 

 

 

 

 

 

 

 

 

12" or more

Noncombustible material

 

okay.

Between 8"

24", 30" or 36" Models:

and 12"

Install fireplace hood

 

accessory (GA6050,

 

GA6052 or GA6053 see

 

Accessories, page 38).

 

18" Model: Noncombus-

 

tible material okay.

Less than 8"

Noncombustible material

 

must be extended to at

 

least 8". See Between 8"

 

and 12", above. If you

 

cannot extend material,

 

you must operate heater

 

with flue damper open.

 

 

 

 

 

Heat Resistant

 

 

 

 

 

 

 

Material

 

 

 

 

 

 

 

 

(A)

 

 

 

 

 

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances,youmustalsomeetrequiredclearances between fireplace opening and mantel shelf. If you do not meet the clearances in Figure 6 you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearance When Using a Hood

IfminimumclearancesinFigure6arenotmet,you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7, page 11 when using hood.

NOTICE: Surface temperatures ofadjacentwallsandmantelsbecomehotduringoperation.Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement ofthenationalproductstandard. Follow all minimum clearances shown in this manual.

 

10"

 

Mantel Shelf

 

Underside

 

 

 

 

 

 

8"

 

 

 

 

 

 

 

 

 

of Mantel

 

6"

 

 

 

 

Shelf

 

2 1/2"

 

 

 

 

 

 

 

 

 

 

All minimum

 

 

 

 

 

distances

 

 

 

 

 

are in inches

Minimum

(A)

 

 

 

 

Log Set

Noncombustible

 

 

 

 

 

 

 

 

24"/30"

Material

12"

18"

20"

22"

24"

Models

 

 

8"

8"

14"

17"

20"

18" Model

 

 

 

 

 

Top of Fireplace

 

 

 

 

 

Opening

 

Minimum

 

Distances to

 

 

 

Noncombustible

Underside of

 

 

 

Material Height

Mantel

 

 

 

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

IMPORTANT:Ifyoucannotmeettheseminimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 11.

Figure 6 - Minimum Mantel Clearances

Without Using Hood

10

www.desatech.com

113097-01D

INSTALLATION

Continued

NOTICE:Ifyourinstallationdoes not meet the minimum clearances shown, you must do one of the following:

operate the logs only with the

flue damper open

raise the mantel to an acceptable height

remove the mantel

 

12"

Mantel Shelf

 

 

 

 

 

 

 

 

Underside

 

10"

 

 

 

 

of Mantel

 

8"

 

 

 

 

Shelf

 

 

 

 

 

 

 

6"

 

 

 

All minimum

 

2 1/2"

 

 

 

 

 

 

 

 

distances are

Minimum

 

 

 

 

in inches

 

 

 

 

 

 

Noncombustible

 

 

 

 

 

Log Set

Material

8"

12"

15"

18"

20"

All

 

Models

 

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of

 

 

 

 

 

 

Fireplace

 

Hood

Distances to

 

 

Opening

 

(GA6050,

 

 

 

 

MantelUnderside of

 

 

 

 

GA6052 and

 

 

 

 

GA6053)

 

 

 

 

 

Figure 7 - Minimum Mantel Clearances

When Using Hood

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Hearth

5"

Min.

Combustible

Material

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper.You must install the damper clamp accessory (to order, see Accessories, page 38). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

Damper

Clamp

Damper

Damper

Clamp

 

 

Damper

Damper

 

Combustible

 

 

14"

Material

 

 

 

 

 

Min.

 

 

 

 

Noncombustible

Masonry

Manufactured

 

Fireplace

Fireplace

 

Material

 

 

 

Figure 8 - Minimum Fireplace Clearances

Figure 10 - Attaching Damper Clamp

if Installed at Floor Level

 

 

113097-01D

www.desatech.com

11

INSTALLATION

Continued

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. in.)

 

 

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

 

 

Area of Various Standard

Round Flues

Diameter (in.)

Area (sq. in.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

 

 

INSTALLING HEATER BASE ASSEMBLY

CAUTION:Donotremovethe dataplatesattachedtotheheater base assembly. The data plates contain important warranty and safety information.

WARNING:You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak.

WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to heater control panel. This will insure adequate air flow and guard against sooting and controls being damaged. Raise fireplacefloorwithnoncombustiblematerial.Makesurematerial is secure.

CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates.

IMPORTANT: Make sure the heater burners are level. If heater is not level, heater will not work properly. For thermostat models, avoid damage to thermostat bulb. Avoid nicks or sharp bends in thermostat bulb wire. Keep thermostat bulb in mounting bracket until ready to mount base to floor. See Optional Positioning Of Thermostat Sensing Bulb, page 28.

Installation Items Needed

hardware package (provided with heater)

approved flexible gas hose (not provided) (if allowed by local codes)

sealant resistant to propane (propane/LP) gas, not provided

electric drill with 3/16" drill bit

flathead screwdriver

1.Applypipejointsealantlightlytomalethreads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 11).

IMPORTANT: Hold gas regulator with wrench when connecting flexible gas hose.

2.Locate masonry screws in hardware package.

3.Position heater base assembly in fireplace.

4.Placelogsintheirproperpositiononheaterbase, see Installing Logs on page 16.

5.Center heater base and logs front-to-back and side-to-side in fireplace.

6.Carefully remove logs without moving heater base.

Flexible Gas Hose

(if allowed by local codes)

Heater Gas

Regulator

Fitting

Figure 11 - Attaching Flexible Gas Hose

to Heater Gas Regulator

12

www.desatech.com

113097-01D