DeLonghi WE130, WE125, WE 110 User Manual

0 (0)

PORTABLE AIR CONDITIONER

INSTRUCTION for use SAVE THESE INSTRUCTIONS

CLIMATISEUR PORTATIF

mode d’emploi CONSERVEZ CE MODE D’EMPLOI

CLIMATIZADOR PORTÁTIL

INSTRUCCIONES DE USO CONSERVE ESTAS INSTRUCCIONES LEA CUIDADOSAMENTE ESTE

INSTRUCTIVO ANTES DE USAR SU APARATO

PAC WE 110 -we125 - WE130

Register this product online and receive a free trial issue of Cook’s Illustrated.  Visit www.delonghiregistration.com.

Visit www.delonghi.com for a  list of service centers near you.

Enregistrez ce produit en ligne et recevez un numéro gratuit de Cook’s Illustrated.

Visitez www.delonghiregistration.com.

Visitez www.delonghi.com pour y voir une liste des centres de réparation proches de chez vous.

Registre este producto en línea y reciba un ejemplar gratis de Cook’s Illustrated.  Visite www.delonghiregistration.com.

Visite www.delonghi.com para ver la lista de centros de servicios cercanos a usted.

Electronic characteristics/Caractéristiques électroniques/Caracteristicas electricas

115V~60Hz 1500W

I M P O R T A N T S A F E G U A R D S

Use this appliance only as described in this instruction manual.

As with all electrical equipment, the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance.

This appliance is designed for home air conditioning and must not be used for other purposes.

It is dangerous to modify or alter the characteristics of the appliance in any way.

The appliance must be installed in accordance with national legislation regulating electrical equipment and installations.

If the appliance requires repair, contact a

Service Center authorized by the manufacturer only.

Repairs carried out by unauthorized personnel may be dangerous.

The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

The appliance must be connected to an efficiently grounded electrical system.

Have your electrical circuit checked by a qualified electrician.

Do not use extension cables.

Before cleaning or maintenance, always unplug the appliance from the outlet.

Never unplug the appliance by pulling on the power cable.

Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.

Keep the appliance at least 19.6 inches (50 cm) away from flammable substances (alcohol etc) or pressurised containers (eg aerosol cans).

Do not rest heavy or hot objects on top of the appliance.

Clean the air filter at least once a week.

Avoid using heating appliances near the air conditioner.

The unit should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.

Before transporting the unit, drain the unit.

After transportation, wait at least 6 hours before switching the unit on.

Only run the appliance on a perfectly horizontal surface.

When putting the appliance away, do not cover with plastic bags.

The materials used for packaging can be recycled.

You are therefore recommended to dispose of them in special differentiated waste collection containers.

At the end of its working life, dispose of the appliance at a specialized collection center.

If the power cable is damaged, it must be replaced by the manufacturer or an authorized technical service centre in order to avoid all risk.

ENVIRONMENTAL INFORMATION:

This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol.

Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).

ELECTRICAL CONNECTIONS

Before plugging the appliance into the outlet, check that:

the power supply corresponds to the value indicated on the rating plate on the back of the appliance;

the outlet and electrical circuit are adequate for the appliance.

the outlet matches the plug. If this is not the case, have the plug replaced;

the outlet is a properly grounded 3 hole outlet.

Failure to follow these important safety instructions absolves the manufacturer of all liability.

2

WHAT IS THE WATER-AIR PINGUINO

During the summer, you feel comfortable at a

temperature of between 75 - 80°F (24 - 27°C) with a relative humidity of about 50%.

An air conditioner removes excess moisture and heat from the room where it is located. Compared with wall mounted models, portable air conditioners have the advantage that they can be moved from one room to another in the home or be transported from one building to another. Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re-emitted into the room.

In single unit models, a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside.

In exclusive De’longhi water-air models, the heat is removed from the room through the cooling effect of the water which is obviously much greater than air.

This gives this air conditioner unbeatable cooling efficiency.

SAVE THESE INSTRUCTIONS

THIS PRODUCT IS INTENDED FOR HOUSHOLD USE ONLY.

3

Description

AAir outlet grille

BControl panel with advanced LCD display

CHandle

DGrille

ECastors

FAir intake grille with dust filter

GCondensate drain connector

HPower cable

ITank door

JPull out tank

K Air exhaust hose

C

LRemote control

MAir exhaust hose housing

N

Window outlet

D

O

Silver ion filter (certain models only)

 

P

Electrostatic filter (certain models only)

 

Q

Sucker

 

R

Indicator paper

 

S

Flange with cap

 

T

Window bracket

E

U

Water drain hose + cap

 

 

K

 

 

L

S

 

F

 

 

T

 

N

 

 

M

 

 

O

 

Q

 

 

P

 

 

U

R

 

H

 

 

A

B

J

I

A

C

G

4

DeLonghi WE130, WE125, WE 110 User Manual

PREPARING FOR USE

The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible.

Before use, make sure the air intake and outlet grilles are unobstructed.

Air-conditioning without installation

Just a few simple steps and your comfort is ensured with your appliance:

Fit the air exhaust hose in the housing at the back of the appliance (fig. 1).

1 2

1

Fit the window outlet (N) to the end of the hose (K).

Place the air conditioner near a window or French window.

Adjust the length of the hose to reach the window.

Make sure the air exhaust hose is unobstructed.

Open the window or French window slightly and position the outlet (fig. 2).

2

If you have a double window, use the sucker

(Q) provided to hold the two parts of the window together (fig. 3).

3 2

1

If you have a sash window, place the window bracket (T) on the window sill, extend the window bracket fully within the window frame, fix the window bracket by using the locking pin then lower the window onto the window bracket. Insert the window outlet

(N) of the exhaust hose (K) into the slot, then connect the hose to the air conditioner (fig. 4).

4

Thanks to the locking pins, it’s possible to use the window bracket also for sliding windows. Position the hole of the window bracket so to allow a correct installation of the exhaust hose (see figure 5).

5

5

Keep the air hose as short and free of curves as possible to avoid bottlenecks.

Air-conditioning with installation

If required, your appliance can be installed semipermanently (Fig. 6).

Proceed as follows:

Drill a 5.27 inch (134 mm) dia. hole in an outside wall or through a window pane, respecting the heights shown in fig. 7.

6

12 inch

30 cm

12 inch

30 cm

Fit the flange accessory (S) provided in the hole following the indications in figs. 8, 9 and

10.

7

MAX 39 inch

MIN 14 inch

8

5 inch 134

in the window pane

9

in the wooden kickboard of a French window

10

in the wall: you are recommended to insulate the section of wall using suitable insulation.

Fit the air exhaust hose (K) in the housing at the back of the appliance (fig. 1).

Fit the end of the hose to the flange (S). When the hose is not fitted, the hole can be closed with the flange cap.

Remove the cap at the back of the appliance

(G)and replace with the drain hose plus cap

(U)as shown in figure 11. This enables the condensate to be drained more easily at the end of the season. See the section: “END OF SEASON OPERATIONS”.

Keep the air hose as short and free of curves as possible to avoid bottlenecks.

When installing the air conditioner semipermanently, you should leave a door slightly open, as little as 0.5 inch (1 cm), to guarantee correct ventilation.

11

6

PREPARING FOR OPERATION IN WATER MODE

Once the appliance has been installed, it is ready for use.

However, its efficiency can be enhanced by operating it in De’Longhi’s patented water mode. The water in the tank increases the cooling power of your Pinguino and at the same time reduces noise levels and electrical consumption. Compared to air, water reduces the temperature of the cooling circuit much more efficiently, before being given off from the air exhaust hose in the form of vapour.

Remember that:

You must always use salt-free clean water, tap water is recommended.

The length of time the water in the tank lasts depends greatly on environmental conditions such as temperature, humidity, insulation, the sun exposure of the room, the number of people present, etc. As an estimate, the water lasts about six hours.

The BOOST function (see page 13) shortens the operating time to about 4 hours, but the cooling power and efficiency are increased.

When the water in the tank runs out, the light comes on and operation of the appliance switches automatically to air-air.

The appliance is fitted with a resin limescale filter enabling normal tap water to be used.

The resins reduce water hardness and therefore prolong the working life of the appliance.

CF” is displayed when the limescale filter needs replacing. The efficacy of the filter depends on water hardness. It should, however, be replaced every five years.

Setting water hardness

Measure water hardness using the indicator paper provided.

Remove the indicator paper from its pack

(R).

Immerse the paper completely in a glass of water for one second.

Remove the paper from the water and sha-

ke lightly. After about a minute, 1, 2, 3, 4 or 5 red squares appear, depending on the hardness of the water. The appliance can be set to three different water hardness levels soft (H1), medium (H2) and hard (H3). Determine the hardness of the water you will be using by comparing the red squares on the indicator paper with the table below.

Water hardness indicator

Level

19

Soft

H1

 

 

20

Medium

 

 

 

H2

 

Hard

H3

 

 

To set water hardness, proceed as follows:

1.Set the appliance to stand-by.

2.Hold the FAN button on the control panel down for 10 seconds. The appliance emits a beep and H1,H2or H3is displayed.

3.Use the + or - buttons to set the hardness level according to the table below. Wait a few seconds for the setting to be memorized. The appliance emits another beep and goes back to stand-by.

The machine is set by default for medium hardness (H2).

Filling the tank

The water tank is located at the bottom of the appliance. Push in on the Tank Door (J) above the word PULL, and pull the tank out as far as it will go (fig. 12). Remove the cap and use a container

(bottle, jug, watering can) to pour in the water

(fig. 13/14). You can see when the tank is full through the filling hole. It holds a maximum of

21 pints (10 liters).

7

Loading...
+ 14 hidden pages